• Title/Summary/Keyword: ablation depth

Search Result 64, Processing Time 0.024 seconds

Processing of gelatin using nanosecond and femtosecond pulsed lasers (나노초 및 펨토초 레이저를 이용한 젤라틴의 미세가공)

  • Seo, C.;Ahn, D.;Kim, D.
    • Laser Solutions
    • /
    • v.15 no.2
    • /
    • pp.1-5
    • /
    • 2012
  • Gelatin is used as a model for soft biological tissues in studying laser interaction with the soft tissues. In this work, we analyze the interaction between gelatin and excimer and Ti:Sapphire femtosecond laser under various conditions, especially by varying the laser, laser fluence and pulse number. The results show that swelling of the surface and ablation depth can be controlled by adjusting the process parameters.

  • PDF

Microstructuring of Optical Fibers Using a Femtosecond Laser

  • Sohn, Ik-Bu;Kim, Young-Seop;Noh, Young-Chul;Ryu, Jin-Chang;Kim, Jin-Tae
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.33-36
    • /
    • 2009
  • Laser ablation with femtosecond lasers is highly promising for microfabrication of materials. Also, the high peak power of femtosecond lasers could induce a multiphoton absorption to ablate transparent materials. Similar results have also been were obtained in the case of optical fibers. In this paper, we present our experimental results of femtosecond laser microstructuring of optical fiber and its applications to microelectronic components and fiber optic devices. Finally, we directly produced micro holes with femtosecond laser pulses in a single step by moving an optical fiber in a preprogrammed structure. When water was introduced into a hole drilled from the bottom surface of the optical fiber, the effects of blocking and redeposition of ablated material were greatly reduced and the aspect ratio of the depth of the hole was increased. We have presented circular and rectangular-shaped holes in optical fiber.

Endpoint Depth When Removing Xanthelasma Using CO2 Laser Ablation: A Case Report

  • Park, Jeong Do;Kim, Se Young;Jeong, Hyun Gyo;Wee, Syeo Young
    • Medical Lasers
    • /
    • v.10 no.4
    • /
    • pp.246-249
    • /
    • 2021
  • The carbon dioxide (CO2) laser is one of the treatment options used for xanthelasma palpebrarum. However, even if the full dermal layer is removed, the lesion can recur due to the residual lipid deposits. A 44-year-old male patient with xanthelasma on both upper eyelids was treated with a pulsed dye CO2 laser. On the right upper eyelid, we carried out a CO2 laser treatment until the yellowish plaque was almost invisible and the full thickness of the dermal layer was removed. On the left upper eyelid, the dermal layer was partially removed and an additional squeezing out of yellowish particles was done. The lesion treated by the squeezing out of lipid droplets showed better long-term results than the lesion treated up to the deeper dermal layer.

Temperature Distributions of the Lumbar Intervertebral Disc during Laser Annuloplasty : A Cadaveric Study

  • Lee, Min Hyung;Kim, Il Sup;Hong, Jae Taek;Sung, Jae Hoon;Lee, Sang Won;Kim, Daniel H.
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.6
    • /
    • pp.559-563
    • /
    • 2016
  • Objective : Low back pain, caused intervertebral disc degeneration has been treated by thermal annuloplasty procedure, which is a non-surgical treatement. The theoretical backgrounds of the annuloplasty are thermal destruct of nociceptor and denaturization of collagen fiber to induce contraction, to shrink annulus and thus enhancing stability. This study is about temperature and its distribution during thermal annuloplasty using 1414 nm Nd : YAG laser. Methods : Thermal annuloplasty was performed on fresh human cadaveric lumbar spine with 20 intact intervertebral discs in a $37^{\circ}C$ circulating water bath using newly developed 1414 nm Nd : YAG laser. Five thermocouples were attached to different locations on the disc, and at the same time, temperature during annuloplasty was measured and analyzed. Results : Thermal probe's temperature was higher in locations closer to laser fiber tip and on lateral locations, rather than the in depth locations. In accordance with the laser fiber tip and the depth, temperatures above $45.0^{\circ}C$ was measured in 3.0 mm depth which trigger nociceptive ablation in 16 levels (80%), in accordance with the laser fiber end tip and laterality, every measurement had above $45.0^{\circ}C$, and also was measured temperature over $60.0^{\circ}C$, which can trigger collagen denaturation at 16 levels (80%). Conclusion : When thermal annuloplasty is needed in a selective lesion, annuloplasty using a 1414 nm Nd : YAG laser can be one of the treatment options.

Electrical Properties of PTFE for Circuit Breaker (차단기용 PTFE의 전기적 특성)

  • Park, Hoy-Yul;Kang, Dong-Pil;Ahn, Myeong-Sang;Lee, Tae-Hui;Myung, In-Hae;Lee, Tae-Joo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.204-207
    • /
    • 2003
  • This paper presents the electrical properties of PTFE (polytetrafluoroethylene) nozzle for circuit breaker. PTFE has been used widely as a nozzle material for circuit breaker. In the arcing environment in a circuit breaker, radiation is considered to be the major energy transport mechanism from the arc to the wall. The fraction of the radiation power is emitted out of the arc and reaches the nozzle wall, causing ablation at the surface and in the depth of the wall. The energy concentration in the material lead to the depolymerization and eventually lead to the generation of decomposed gas as well as some isolated carbon particles. The generation of the decomposed gas in the depth of the material causes inner explosion. The surface of nozzle becomes uneven. The flow of gas is not uniform due to the unevenness of the surface. Adding some fillers into PTFE is expected to be efficient for improving the endurability against radiation. In this experiment, three kinds of fillers that have endurance in the high temperature environment were added into PTFE. Dielectric constant, dissipation factor, electrical resistivity and dielectric strength of PTFE composites were investigated.

  • PDF

Basic Experimental Investigations to UV Laser Micro-Machining of Nano-Porous Alumina Ceramic Material (나노 다공 구조를 가진 알루미나 재료의 UV 레이저 미세가공에 관한 실험적 기초 연구)

  • Shin, Bo-Sung;Lee, Jung-Han
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.1
    • /
    • pp.62-67
    • /
    • 2012
  • Recently UV laser is widely used to process micro parts using various materials such as polymers, metals and ceramics because it has a very high intensity at the focused spot area. It is generally known that there are still some difficulties for alumina($Al_2O_3$) ceramics to directly make micro patterns like holes and lines on the surface of working material using 355nm UV laser because the alumina has a very low absorption coefficient at that wavelength. But nowadays new alumna with nano-porous holes is developed and applied to advanced micro functional parts of IT, BT and BT industries. In this paper, we are going to show the mechanism of photo-thermal ablation for nano-porous ceramics. Inside hole there is a lot of multiple reflections along the depth of hole. Experimentally we can find the micro hole drilling and micro grooving on the surface of nano-porous alumina.

Endoscopic Mucosal Resection (내시경 점막 절제술)

  • Kim, Gwang Ha
    • Korean Journal of Bronchoesophagology
    • /
    • v.17 no.1
    • /
    • pp.23-28
    • /
    • 2011
  • Diagnosis of early esophageal cancer has become more frequent as a result of improved endoscopic technology, surveillance programmes, and increasing experience and awareness on the part of endoscopists. In early esophageal cancer, squamous cell carcinoma and early adenocarcinoma must be managed differently because they have different origins, pathogenesis. and clinical characteristics. The current treatment options vary widely, from extended resection with lymphadenectomy to endoscopic mucosal resection (EMR) or ablation. None of these treatment options can be recommended universally. Instead, an individualized strategy should be based on the depth of tumor infiltration into the mucosa or submucosa, the presence or absence of lymph node metastases, the multicentricity of tumor growth, the length of the segment of intestinal metaplasia, and comorbidities of the patient. EMR has become increasingly important, both as a diagnostic tool for the staging of esophageal carcinomas and as a method of carrying out definitive treatment when the cancer meets certain criteria in which the risk of lymph-node metastasis is negligible. EMR may be sufficient in a subset of patients who have m1 or m2 squamous cell carcinoma and in patients who have isolated foci of high-grade intraepithelial neoplasia or mucosal cancer.

  • PDF

Electrical Properties of Nozzle for Electrical Apparatus (전력기기용 Nozzle의 전기적 특성)

  • Park, Hoy-Yul;Kang, Dong-Pil;Ahn, Myeong-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.7-10
    • /
    • 2004
  • This paper presents the electrical properties of PTFE nozzle for a electrical apparatus. In the arcing environment in a electrical apparatus, radiation is considered to be the major energy transport mechanism from the arc to the wall. The fraction of the radiation power is emitted out of the arc and reaches the nozzle wall, causing ablation at the surface and in the depth of the wall. The energy concentration in the material leads to the depolymerization and eventually leads to the generation of decomposed gas as well as some isolated carbon particles. Adding some fillers into PTFE is expected to be efficient for improving the endurability against radiation. In this experiment, three kinds of fillers that have endurance in the high temperature environment were added into PTFE. Light reflectance of fillers was investigated. Dielectric constan and dissipation factor of PTFE composites were investigated. Dielectric constant and dissipation factor of the PTFE composites increased with increasing contents of the fillers.

  • PDF

A Development of Test Equipment for Thermal Protection Performance on Insulator used in Solid Rocket Motor (고체로켓 추진기관용 연소관단열재의 내열성능평가를 위한 시험장치 개발)

  • Kang, Yoongoo;Yun, Deokjin;Kim, Suyoung;Lee, Jongsung;Kwon, Taeha
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.543-546
    • /
    • 2017
  • Test equipment was designed and manufactured to evaluate thermal reaction characteristic of internal insulators of solid rocket motor. Test is allowed up to chamber pressure 2,500 psi, burn-time 40 s. It is possible to observe and to compare thermal reaction characteristic for a few materials simultaneously, under the condition that the ablation occurs. In efficient average chamber pressure 878 psi, efficient burn-time 10.7 s and gas velocity 100 m/s, test was executed for confirming safety of equipment, being 4 test materials inserted simultaneously. Basic data for understanding thermal characteristic of internal insulator, that is, pressure-time curve, temperature-time curve in the test sample, and thermal destruction depth of test samples was gained successfully.

  • PDF

Arc Resistance and Light Reflectance of PTFE for Circuit Breaker (차단기용 PTFE의 내아크성과 광반사율)

  • Park, Hoy-Yul;Kang, Dong-Pil;Ahn, Myeong-Sang;Lee, Tae-Joo;Lee, Tae-Hui;Myung, In-Hae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.200-203
    • /
    • 2003
  • A study on the arc resistance and light reflectance of PTFE (polytetrafluoroethylene) nozzle for circuit breaker is presented. PTFE has been used widely as a material for circuit breaker nozzle. PTFE has excellent electrical resistivity, high melt viscosity, chemical inertness, heat resistance and low loss factor. PTFE melts at $327\;^{\circ}C$ but the viscosity is very high above the melting point. In the arcing environment in a circuit breaker, the fraction of the power is emitted out of the arc and reaches the nozzle wall by radiation, causing ablation at the surface and in the depth of the wall. Some fraction of the radiation power emitted out of the arc directly break up the chemical bonds at the surface while some fraction of the radiation power penetrates into the wall, heats up the material to evaporation temperature and causes damages deeper inside the volume of the nozzle. In this paper, some fillers that have endurance in the high temperature arc environment were added into PTFE. Adding some fillers into PTFE was expected to be efficient in improving the endurability against radiation. The light reflectance and arc resistance of PTFE composites were investigated.

  • PDF