• Title/Summary/Keyword: abbe number

Search Result 15, Processing Time 0.019 seconds

Synthesis of Ultra High Refractive Index Monomer for Plastic Optical Lens and Its Ophthalmic Lens Preparation (플라스틱 안경렌즈용 초고굴절 모노머 합성 및 이를 이용한 안경렌즈 제조)

  • Jang, Dong Gyu;Kim, Jong Hyo;Lee, Soo Min;Roh, Soo Gyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.1-6
    • /
    • 2008
  • Purpose: Plastic optical monomer materials having ultra high refractive index have an income of the whole quantity from advanced nations to domestic companies which are related to plastic optical lens. It is necessary to develop novel plastic optical lens materials in order to overcome a FTA provision and revitalize a stagnating optical lens industry in the interior optical lens industries. The new plastic optical lens materials against the substitution effect of income should be gradually demanded. This work will be synthesized novel super high refractive monomer resin materials of urethane lens series and studied the properties of optical lens using it. Methods: ETS-4 (2-(2-mercaptoethylthio)-3-{2-[3-mercapto-2-(2-mercaptoethylthio)propyl thio]ethylthio}propane -1-thiol), which is optical lens monomer resin having super high refractive index, was synthesized and identified its structure and property by elemental analysis, EI-MS, TGA, FT-IR spectroscopy, $^1H$ and $^{13}C$ NMR spectroscopies. After mixing evenly from mixed monomer resin and diisocyanate series, it was casting in glass mold. After thermal curing, the obtained optical lenses were measured and compared with the refractive index and Abbe number for studies of their optical properties. Results: We have synthesized the novel ultra high refractive index monomer resin, ETS-4, and have identified its structure and property by elemental analysis, EI-MS, TGA, FT-IR spectroscopy, $^1H$ and $^{13}C$ NMR spectroscopies. The existence of three isomers for EST-4 was identified by $^{13}C$ NMR spectroscopy. The refractive index ($N_d$ at $25^{\circ}C$) of monomer resin in liquid state obtained from the Abbe refractometer was 1.647. The refractive indexes of raw plastic optical lenses prepared from the mixed ETS-4 monomer and diisocyanate series were in the range of 1.656~1.680. Conclusions: Novel super high refractive index plastic optical lens monomer was synthesized and analysed, the optical lenses prepared using it were colorless transparency and excellent properties. It is of utility for the industrialization.

  • PDF

Collimation testing of a white light beam and measurement of chromatic aberration of a lens by using vernier Moire fringe patterns (버니어 무아레 무늬를 이용한 백색광의 시준 검사 및 렌즈의 색수차 측정)

  • 송종섭
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.4
    • /
    • pp.232-238
    • /
    • 2000
  • The new collimation testing technique of a white light beam using vernier Moire fringes of two line or circular gratings with different pitches is presented. We can visually measure the defocusing ($\Deltaf$), the divergence angle ($\theta$), and the longitudinal chromatic aberration $(L_{ch})$ of a collimating lens by using the technique. For example, we obtained $\Deltaf$= 21.9 mm and $\theta=0.0038^{\circ}$ for a testing lens with the focallengthf = 120.0 mm and F-number of F/2.4. The longitudinal chromatic aberration $L_{ch}$ of another testing lens withf = 65.0 mm, F/1.6, and the Abbe number V = 64.1 for the incident wavelengths of $\lambda_1=480 nm and \lambda_2=640 nm$ is easily measured by same technique. It is found that the measured value $L_{ch}=1.59mm(\pm0.01mm)$ is well agreed with $L_{ch}=1.58mm(\pm0.01mm)$ obtained by the autofocus method.

  • PDF

Synthesis of Novel Polythiol for Plastic Optical Lens and its Ophthalmic Lens

  • Jang, Dong-Gyu;Roh, Soo-Gyun;Kim, Jong-Hyo;Jin, Wen-Yi;Seo, Jin-Moo;Kwon, Myeong-Ja;Lee, Soo-Min
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.10
    • /
    • pp.2227-2232
    • /
    • 2009
  • Novel polythiol materials of urethane lens series for plastic optical lens were synthesized from polyol materials via thioisouronium of thiourea with c-HCl in refluxing aqueous solution, in which polythiol material was carried out from hydrolysis of thioisouronium by ammonia water. Their structure properties were identified by EA, EI-MS, FT-IR, $^1H\;and\;^{13}C$ NMR spectroscopies and TGA. Their ophthalmic lenses as polythiourethane material were prepared by thermal curing to an injected glass mold using the evenly solutions of diisocyanates series (TDI, XDI, HDI or IPDI) with polythiols. Polythiourethane shows that the strong stretching mode for SH group of polythiol disappeared in FT-IR spectra after thermosetting polymerization. Thermal deformation starting temperature of ophthalmic lenses was determined by TMA. Ophthalmic lenses made from characteristic polythiol and diisocyanate series have transparency, colorless and good impact strength, in which thermal resistance and impact strength of ophthalmic lenses were influenced by diisocyanate series. Physical properties of ophthalmic lens have contrast thermal resistance with impact strength. The property of thermal resistance and impact strength for respective ophthalmic lenses was examined by TMA and drop ball test.

The effect of resin thickness on polymerization characteristics of silorane-based composite resin

  • Son, Sung-Ae;Roh, Hyoung-Mee;Hur, Bock;Kwon, Yong-Hoon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.4
    • /
    • pp.310-318
    • /
    • 2014
  • Objectives: This study examined the influence of the resin thickness on the polymerization of silorane- and methacrylate-based composites. Materials and Methods: One silorane-based (Filtek P90, 3M ESPE) and two methacrylate-based (Filtek Z250 and Z350, 3M ESPE) composite resins were used. The number of photons were detected using a photodiode detector at the different thicknesses (thickness, 1, 2 and 3 mm) specimens. The microhardness of the top and bottom surfaces was measured (n = 15) using a Vickers hardness with 200 gf load and 15 sec dwell time conditions. The degree of conversion (DC) of the specimens was determined using Fourier transform infrared spectroscopy (FTIR). Scratched powder of each top and bottom surface of the specimen dissolved in ethanol for transmission FTIR spectroscopy. The refractive index was measured using a Abbe-type refractometer. To measure the polymerization shrinkage, a linometer was used. The results were analyzed using two-way ANOVA and Tukey's test at p < 0.05 level. Results: The silorane-based resin composite showed the lowest filler content and light attenuation among the specimens. P90 showed the highest values in the DC and the lowest microhardness at all depth. In the polymerization shrinkage, P90 showed a significantly lower shrinkage than the rest two resin products (p < 0.05). P90 showed a significantly lower refractive index than the remaining two resin products (p < 0.05). Conclusions: DC, microhardness, polymerization rate and refractive index linearly decreased as specimen thickness linearly increased. P90 showed much less polymerization shrinkage compared to other specimens. P90, even though achieved the highest DC, showed the lowest microhardness and refractive index.

Anesthetic efficacy of primary and supplemental buccal/lingual infiltration in patients with irreversible pulpitis in human mandibular molars: a systematic review and meta-analysis

  • Gupta, Alpa;Sahai, Aarushi;Aggarwal, Vivek;Mehta, Namrata;Abraham, Dax;Jala, Sucheta;Singh, Arundeep
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.21 no.4
    • /
    • pp.283-309
    • /
    • 2021
  • Achieving profound anesthesia in mandibular molars with irreversible pulpitis is a tedious task. This review aimed at evaluating the success of buccal/lingual infiltrations administered with a primary inferior alveolar nerve block (IANB) injection or as a supplemental injection after the failure of the primary injection in symptomatic and asymptomatic patients with irreversible pulpitis in human mandibular molars. The review question was "What will be the success of primary and supplemental infiltration injection in the endodontic treatment of patients with irreversible pulpitis in human mandibular molars?" We searched electronic databases, including Pubmed, Scopus, and Ebsco host and we did a comprehensive manual search. The review protocol was framed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) checklist. We included clinical studies that evaluated and compared the anesthetic outcomes of primary IANB with primary and/or supplementary infiltration injections. Standard evaluation of the included studies was performed and suitable data and inferences were assessed. Twenty-six studies were included, of which 13 were selected for the meta-analysis. In the forest plot representation of the studies evaluating infiltrations, the combined risk ratio (RR) was 1.88 (95% CI: 1.49, 2.37), in favor of the secondary infiltrations with a statistical heterogeneity of 77%. The forest plot analysis for studies comparing primary IANB + infiltration versus primary IANB alone showed a low heterogeneity (0%). The included studies had similar RRs and the combined RR was 1.84 (95% CI: 1.44, 2.34). These findings suggest that supplemental infiltrations given along with a primary IANB provide a better success rate. L'Abbe plots were generated to measure the statistical heterogeneity among the studies. Trial sequential analysis suggested that the number of patients included in the analysis was adequate. Based on the qualitative and quantitative analyses, we concluded that the infiltration technique, either as a primary injection or as a supplementary injection, given after the failure of primary IANB, increases the overall anesthetic efficacy.