• Title/Summary/Keyword: aCM curve

Search Result 523, Processing Time 0.029 seconds

Drying Characteristics of Large Western Redcedar Timber During Radio Frequency/Vacuum Drying (웨스턴 레드시더 큰 정각재(正角材)의 고주파 진공 건조 특성)

  • Jung, Hee-Suk;Avramidis, Stavros;Cai, Liping
    • Journal of the Korean Wood Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.1-8
    • /
    • 1998
  • Western redcedar timber, 26 by 26cm in cross section and by 200cm long, was dried in a laboratory radio-frequency/vacuum kiln under 65torr of ambient pressure and a fixed frequency of 6.78MHz for the potential rapidly dry large timber. All process data were collected and saved in a computer through a data acquisition system. The temperature in the middle of timber was higher than temperature at the quarter point of timber length and thickness. Temperature gradients developed in the longitudinal and transverse direction of timber. The pressure in the middle of timber was higher than pressure at the quarter point of timber length. The pressure in the middle of timber was lower in the early stage of drying, and higher in the latter stage of drying than pressure at the quarter point of timber thickness. Power density was very highest during heating period and then gradually decreased. The drying curve was approximately linear and the total drying time was 27 hours from an initial moisture content(MC) of 48.6 percent to a final Me of 19.2 percent with only a few mild internal checks in the middle location of timber.

  • PDF

Reverse Anterolateral Thigh Flap to Reconstruct a Below-Knee Amputation Stump: Two Case Reports

  • Chung, Duke-Whan;Han, Chung-Soo;Lee, Jae-Hoon;Hong, Se-Hyuk
    • Archives of Reconstructive Microsurgery
    • /
    • v.20 no.1
    • /
    • pp.51-56
    • /
    • 2011
  • During below knee amputation, the amputation stump must be covered with well-vascularized and sensate soft tissue. Many flaps can be used for this purpose, but available reconstructive options are limited. We performed reverse flow ALT flap elevation on two patients with below knee amputations to reconstruct defects in the stumps. The sizes of the defects in the stumps were $4{\times}16$ cm and $5{\times}5$ cm, respectively. The most distal portion of the defects were located 20 cm and 16 cm lateral to the knee joint in a curve, respectively. The size of the elevated flap was $5{\times}18$ cm for case 1 and $18{\times}10$ cm for case 2. The respective pivot points of the pedicles were 7 cm and 6 cm above the patella and the respective lengths of the pedicles were 17 cm and 16 cm. In both cases, venous congestion occurred on the second postoperative day and the flap distal to 10 cm or more from below the knee joint was necrotized at the second postoperative week. Surgeons should be cautious when using a reverse ALT flap to reconstruct a soft tissue defect located 10 cm or more distal from below the knee joint. Since a pedicle longer than 15 cm may develop partial necrosis of the flap, simultaneous application of antegrade venous drainage is recommended.

  • PDF

A research on the pattern fabrication of skirt due to the lower body type of the old aged woman (노년기 여성의 하반신 체형분석에 따른 스커트 원형 제작에 관한 연구)

  • Kim, Kyung-Hee;Lee, Kun-Hee
    • Journal of Fashion Business
    • /
    • v.15 no.5
    • /
    • pp.178-194
    • /
    • 2011
  • Due to the population growth of the old aged, Korea is also entering into an aging society. But a research on the pattern design to the old aged is much to be desired. The purpose of this research is to design skirt pattern fitted for each body type by categorizing the lower body type of the old aged woman. For the way of research, categorized the body type by using the female measuring size from the 65 years old to 99 years old which has been measured by the Korean body size research as an assay data, and base on this data, a suitable skirt pattern for each body type of the old aged woman was designed by practicing the exterior evaluation. The data analysis was done with the statistical treatment in SPSS 12.0, and the results are as follows. The lower body type of the old aged woman were divided into the type 1. The circumference article is the biggest compared to the height article regarding to the lower body type of the old aged woman. The type 2. The height article and the circumference and thickness articles are the poorest. The type 3. The height article is the biggest and the hip width and calf circumference are thicker than the waist width. The type 4. The height article is the lowest and the waist width is thicker instead the hip and leg are thinner. In type 1, The pattern was modified by increasing 1cm a length of the dart and raising up 1.2cm at the cross point between side line and waist line. In type 2, the basic pattern was used, and in type 3, using the outline of the basic pattern however, increased 1cm a length of the dart and modified the amounts of dart by handling the art in curve, and modified the waist line to be more three-dimensional curves by raising up 1 cm at the cross point between waist line and side line and falling down 0.5cm at the cross point between the back center line and the waist line. In type 4, modified the amounts of front and back dart to 1.25cm, and raised up 0.8cm at the cross point between side line and waist line, and modified the waist line and the side seam line in a gentle curve by reducing circumference of the skirt tail to 1cm from the side seam line.

Transabdominal Ultrasound Assessment of the Polycystic Ovary Syndrome (다낭난소증후군 진단시 복식 초음파의 유용성에 관한 연구)

  • Jeong, Kyung-Ah;Lee, Woon-Jeong;Chung, Hye-Won
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.36 no.4
    • /
    • pp.255-263
    • /
    • 2009
  • Objective: The objective of the study was to determine the diagnostic performance of transabdominal ultrasound by receiver operating characteristic (ROC) curve analysis, in order to evaluate the usefulness in establishing the diagnosis of polycystic ovary syndrome (PCOS). Methods: Questionnaires were given to 8,793 reproductive women reviewed at Ewha Womans University Mokdong hospital. Ultrasound examinations were performed in 701 women with a transabdominal transducer. Transabdominal ultrasounds were performed in 185 normal control women (normal menstruation without hyperandrogenism or PCO morphology) and 248 PCOS patients according to National Institutes of Health (NIH) PCOS diagnosis criteria. ROC curves were calculated for ovarian volume and follicle number. Results: In normal control group, the mean age were $23.64{\pm}4.26$ years old and the mean ovarian volume and follicle number were $6.03{\pm}1.89\;cm^3$ and $6.49{\pm}1.93$, respectively. The ovarian volume showed an area under the ROC curve (AURC) of 0.761. A ovarian volume decision threshold >$9\;cm^3$ had a sensitivity of 51.0% and a specificity of 91.4% for the diagnosis of PCOS. The follicle number showed an AURC of 0.733. A follicle number decision threshold ${\geq}9$ had a sensitivity of 54.9% and a specificity of 87.0% for the diagnosis of PCOS. A follicle number decision threshold ${\geq}10$ had a sensitivity of 53.2% and a specificity of 90.4%. A follicle number and a ovarian volume did not have a high diagnostic power for screening for PCOS. Conclusion: Our results suggest that transabdominal ultrasound assessment is not effective for the detection of PCOS in young women of reproductive age.

19 years of change in community structure of Quercus acutissima dominant stand on Mt. Danseok-san in Gyeongju national park, South Korea (경주 단석산 상수리나무 우점식분 군집구조의 19년간의 변화)

  • Ko, Jae Ki
    • Journal of Wetlands Research
    • /
    • v.20 no.3
    • /
    • pp.243-248
    • /
    • 2018
  • This study was carried out to clarify changes in community structure of Quercus acutissima dominant stand on the south slope of Mt. Danseok-san with fixed twenty quadrates. Five field surveys were conducted from Aug. 1999 to May 2018. During the period, the density lessened to 0.20 in 2012 comparing with 0.33 in 1999. However recent field study in 2018 showed moderate rising to 0.24. In 1999, the DBH class distribution of all trees formed reverse J curve. However, the reverse J curve was torn down, forming bell curve. In 2018, the curve showed similar shape of reverse J shape on the group of young trees, forming bell shape on the group of mature trees. It reveals that DBH 13cm is on the threshold of trees competition trend where the downtrend in the trees are on uptrend. The most dominant Q. acutissima formed bell curve. The peak of the curve shows the shift to the right of the graph as it gets lower by year.In case of Q. mongolica, shows a change in the shape of a low bell as the distribution curve increases. The oak stand in this study is in the process of changing from the initial stage of the secondary forest succession to the intermediate stage. The most dominant tree is Q. acutissima, and the sub-dominant tree is Q. mongolica in present. Considering the age distribution of the two competing tree species, the succession of this stand is expected to transfer to the Q. mongolica-dominant community.

Residence Time Distributions of Liquid pbase Flow and Mass Transfers in the Trickle Bed Reactor (점적상 반응기에서 액상흐름의 체류시간 분포 및 물질전달)

  • Kim, Ki-Chang
    • Journal of Industrial Technology
    • /
    • v.6
    • /
    • pp.19-31
    • /
    • 1986
  • The residence time distribution of liquid flow in a 4.0cm diameter column packed with porous $Al_2O_3$ spheres of 0.37cm diameter were measured with pulse injections of a tracer under cocurrent trickling flow conditions. The mean residence time of liquid flow and liquid hold-up calculated by the transient curve of tracer were unaffected by gas flow rates under experimental ranges of liquid flow rates from 2.4 to $4.5(kg/m^2\;sec)$ and gas flow rates from 0 to $0.13(kg/m^2\;sec)$. The axial dispersion coefficient of liquid stream and apparent diffusivity of tracer in a micropore of solid particle were estimated from the response curve of tracer. The calculated Peclet No. were increased in ranges of 68-to 82 with a increasing of liquid mass velocity, and the external effective contacting efficiency between liquid and solid which can be expressed. by $(D_i)_{app}/D_i$ varied in ranges of 0.54 to 0.68 depending on the liquid flow rates. The gas to liquid(water) volumetric mass transfer coefficient were determined from desorption experiments with oxygen at $25^{\circ}C$ and 1 atm. The measured mass transfer coefficients were increased with liquid flow rates and the effect of gas flow rates on the mass transfer coefficient was insignificant.

  • PDF

Comparison of Drying Characteristics of Square Timber by Heated Platen and Radio-frequency/Vacuum Drying (큰 정각재의 가열판과 고주파 진공건조간 건조특성의 비교)

  • Jung, Hee-Suk;Kang, Wook;Lee, ChuI-Hyun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.108-114
    • /
    • 2002
  • Red pine(Pinus densiflora) square timbers with 14.0 cm and 16.5 cm of face size and 24 m long were dried in a vacuum-press kiln and in a radio-frequency/vacuum(RF/V) kiln to compare drying rate, moisture content(MC) distribution and specific energy. RF/V drying rate was higher than vacuum-press drying rate. The effect of size of cross section on the RF/V drying rates were more pronounced than those of vacuum-press drying. The longitudinal- and the transverse MC distribution of dried square timber showed convex profile for the vacuum-press drying and concave profile for the RF/V drying. Moisture gradient of width direction was similar to the thickness direction in vacuum-press dried square timber and was more slight than that of the thickness direction in the RF/V dried large square timber. The specific energy consumption curve increased as MC decreased. Specific energy(kWh/kg of water evaporated) of the vacuum-press process required more than that of the RF/V process.

Growth and electro-optical characteristics of CdSe/GaAs epilayers prepared by electron beam epitaxy (전자빔 증착법에 의한 CdSe/GaAs epilayer의 성장과 그 전기-광학적 특성)

  • Yang, D.I.;Shin, Y.J.;Lee, C.H.;Choi, Y.D.;Yu, P.R.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.7 no.1
    • /
    • pp.70-75
    • /
    • 1997
  • An improved technique based upon an electron beam evaporation system has been developed to prepare cubic thin films In crystalline semiconductors. Zinc blonde CdSe epilayers were grown on GaAs(100) substrate by an e-beam evaporation method. The lattice parameter obtained from (400) reflection is $6.077\AA$, which is in excellent agreement with the value reported in the literature for zinc blonde CdSe. The orientation of the as-grown CdSe epilayer is determined by electron channeling patterns. The crystallinity of epitaxial CdSe layers were investigated on the double crystal X-ray rocking curve. The carrier concentration and mobility of epilayers deduced by Hall effect measurement are about $10^{18}{\textrm}{cm}^{-3}$, $10^2\textrm{cm}^2/V{\cdot}sec$ at room temperature, respectively. The photocurrent spectrum peak of the epilayer at 30 K exhibits a sharp change at 1.746 eV due to the free exciton of cubic CdSe.

  • PDF

Characteristics of Ultra-thin Polymer Ferroelectric Films (초박막 폴리머 강유전체 박막의 특성)

  • Kim, Kwang-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.4
    • /
    • pp.84-87
    • /
    • 2020
  • The properties of ultra-thin two-dimensional (2D) organic ferroelectric Langmuir-Blodgett (LB) films of the poly(vinylidene fluoride-trifluoroethylene) [P(VDF-TrFE)] were investigated to find possible applicability in flexible and wearable electronics applications. In the C-V characteristics of the MFM capacitor of 2-monolayer of 5 nm films, a butterfly hysteresis curve due to the ferroelectricity of P(VDF-TrFE) was confirmed. Typical residual polarization value was measured at 2μC/㎠. When the MFM capacitor with ultra-thin ferroelectric film was measured by applying a 10 Hz bipolar pulse, it was shown that 65% of the initial polarization value in 105 cycles deteriorated the polarization. The leakage current density of the 2-monolayer film was maintained at about 5 × 10-8 A/㎠ for the case at a 5MV/cm electric field. The resistivity of the 2-monolayer film in the case at an electric field at 5 MV/cm was more than 2.35 × 1013 Ω·cm.

Usefulness of Estimated Height Loss for Detection of Osteoporosis in Women

  • Yeoum, Soon-Gyo;Lee, Jong-Hwa
    • Journal of Korean Academy of Nursing
    • /
    • v.41 no.6
    • /
    • pp.758-767
    • /
    • 2011
  • Purpose: This study was done to examine the threshold value of estimated height loss at which the risk of osteoporosis increases and to verify its discriminative ability in the detection of osteoporosis. Methods: It was conducted based on epidemiological descriptive methods on 732 Korean women at a public healthcare center in Seoul between July and November 2010. ANOVA, Pearson correlation, logistic regression analysis and receiver operating characteristics (ROC) curve were used for data analysis. Results: There was an age-related correlation between bone mineral density (lumbar spine: F=37.88, p<.001; femur: F=54.27, p<.001) and estimated height loss (F=27.68, p<.001). Estimated height loss increased significantly with decreasing bone mineral density (lumbar spine: r=-.23, p<.001; femur: r=-.34, p<.001). The odds ratio for the point at which the estimated height loss affects the occurrence of osteoporosis was found to increase at a cut-off value of 2 cm and the area under ROC curve was .71 and .82 in lumbar spine and femur, respectively. Conclusion: The optimal cut-off value of the estimated height loss for detection of osteoporosis was 2 cm. Height loss is therefore a useful indicator for the self-assessment and prognosis of osteoporosis.