• Title/Summary/Keyword: a.c. magnetic susceptibility

검색결과 71건 처리시간 0.028초

A Simple a.c. Magnetic Susceptometer Using self-inductance Measurement of a Single Coil Mounted on a Cryostat Cold Head

  • Dho, Joong-Hoe
    • Journal of Magnetics
    • /
    • 제13권4호
    • /
    • pp.177-181
    • /
    • 2008
  • A very simple a.c. magnetic susceptometer for use in a helium closed cycle cryostat is reported in this paper. This simple setup has only a single bobbin-less copper coil, instead of the primary coil and two secondary coils typically used in mutual-inductance types. The single bobbin-less copper coil is directly mounted on the cryostat cold head. A sample is attached on the inside wall of the copper coil using a thermal contact material and its a.c. magnetic susceptibility is obtained from the measurement of the self-inductance of the sample coil using an LCR meter or an impedance analyzer. Experimental details are described and illustrative measurements on magnetic and superconducting materials as a function of temperature are included. The performances and limitations of this simple a.c. magnetic suceptometer are also discussed.

Measurements of the Diamagnetic Susceptibility of NaCl Aqueous Solution

  • Lee, Seung-Hwan
    • 한국항해항만학회지
    • /
    • 제27권6호
    • /
    • pp.669-675
    • /
    • 2003
  • Using a SQUID magnetometer, the diamagnetic susceptibility of NaCl aqueous solution was measured with high accuracy in a magnetic field of up to 6 Tat 25$\pm0.05^{\circ}C$. The NaCl concentrations adopted in this experiment were 0 (water), 7.5, 15, 23, 26.2, 26.6 and 100% (crystal) with the concentration error of $\pm$0.04%. Experimental data was compared with the calculated value of susceptibility derived from dependence of the vapor pressure on NaCl concentration As a result, our measured value was almost in accordance with the calculated value. It was found that the diamagnetic susceptibility shows a decrease of approximately 10% within the saturated concentration (26.2%) and that the susceptibility is one of the effective cause for the concentration dependence in the gas-liquid interface deformation of the NaCl solution.

광물성 한약으로 이용되는 양기석, 연옥,음기석의 분광학적 및 자기적 특성 (Spectmscopic and Magnetic Properties of Yanggiseok, Yeonok and Eumgiseok used as Mineral Medicine)

  • 김선옥;박맹언;정율필
    • 자원환경지질
    • /
    • 제35권4호
    • /
    • pp.317-323
    • /
    • 2002
  • 양기와 음기를 보하는 약재로 알려진 양기석과 음기석 및 연옥에 대한 의료적 활용을 파악하고, 광물학적 특성, 분광학적 및 자기적 특성을 규명하기 위하여 X선 형광분석, X-선 회절분석, 주사전자현미경, 적외선 분광분석, 핵자기 공명분석 및 감응자기력을 실시하였다. 광물성 한약으로 사용되는 양기석은 양기석으로 확인되었으뗘, 연옥은 투각섬석으로 구성되었다. 또한, 음기석은 주로 질석으로 구성되며, 소량의 카올리나이트와 할로이사이트를 함유하였다. 사슬형 규산염 중 각섬석군에 속하는 이들 연옥과 양기석은 유사한 범위의 분광학적 특성을 가지며, 연옥은 4$0^{\circ}C$에서 방사에너지가 큰 반면, 양기석은 15$0^{\circ}C$에서 방사에너지가 크다 음기석은 각섬석군의 광물보다 4$0^{\circ}C$와 15$0^{\circ}C$에서 모두 낮은 방사에너지를 나타내었다. 광물성 한약을 증류수에 20일간 침적한 후에 측정한 NMR분석에서의 선폭은 음기석, 양기석, 연옥의 순으로 감소되나, 80일이 경과한 후의 결과는 음기석, 연옥, 양기석 순으로 감소하였다. 양기석과 음기석은 가열 온도가 높아짐에 따라 감응 자기력 값이 대체적으로 증가하고, 연옥은 감소하는 경향을 나타내었다. 광물별로는 상온과 가열시 모두 음기석, 양기석, 연옥의 순으로 감소하였다.

HK-40강의 열화도에 따른 자화율의 변화 (Magnetic Susceptibility depending on the Thermal Degradation of HK-40 Steel)

  • 김정민;손대락;박종서;남승훈;김동균;한상인;최송천;류대현
    • 비파괴검사학회지
    • /
    • 제24권1호
    • /
    • pp.22-28
    • /
    • 2004
  • 현장에서 사용된 열화도가 같기 다른 여러 종류의 가열로 튜브 사용재를 확보하는 것이 실상 어려운 일이다. 따라서 가열로 튜브 사용재의 미세조직을 모사하기 위하여 HK-40강을 등온 열처리하였다. $1050^{\circ}C$에서 등온 열처리하여 열처리시간이 다른 5개의 시험편을 준비하였다. 열화시간에 따른 HK-40강의 열화도를 비파괴적으로 평가하는 방법을 제안하기 위하여 자기적 성질 중 자화율의 변화를 연구하였다. 자화율은 상온에서 열화도가 커짐에 따라 증가하였다. 자기적 방법으로 측정한 자화율의 변화를 인장특성, 경도의 변화와 비교하여 보았다. HK-40강의 미세조직 관찰 및 EDS 분석을 통하여 미세조직의 변화가 인장 특성과 경도, 자화율에 영향을 주는지 살펴보았다. 실험결과를 토대로 자화율을 이용하여 HK-40강의 열화도를 비파괴적인 평가할 수 있는 방법을 제안하였다.

핵자기 뇌기능 영상에서 SSFPI 기법을 이용한 자화율효과의 관찰 (Observation of Susceptibility Change in fMRI Using SSFP Interferometry (SSFPI) Technique)

  • 정준영;정순철;노용만;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 추계학술대회
    • /
    • pp.173-176
    • /
    • 1995
  • We have developed a fast steady state free precession interferometry (SSFPI) technique which is useful for the fMRI (functional Magnetic Resonance Imaging). As is known, SSFP sequence with a suitable adjustment of gradient (readout) allows us to measure precession angle $\theta$ which is in turn related to the field inhomogeneity [1-3]. When the method is applied to the susceptibility effect based functional magnetic resonance imaging (fMRI), it was found that the direct susceptibility effect measurement was possible without perturbations such as the backgrounds and inflow effect. In this paper, simulation results and experimental results obtained with 2.0 Tesla MRI system are also presented.

  • PDF

높은 자장하에서 자기공명 영상 왜곡이 완화된 생체용 Ti 복합재료 (Bio-applicable Ti-based Composites with Reduced Image Distortion Under High Magnetic Field)

  • 김성철;김유찬;석현광;양석조;손인진;이강식;이재철
    • 대한금속재료학회지
    • /
    • 제50권5호
    • /
    • pp.401-406
    • /
    • 2012
  • When viewed using a magnetic resonance imaging (MRI) system, invasive materials inside the human body, in many cases, severely distort the MR image of human tissues. The degree of the MR image distortion increases in proportion not only to the difference in the susceptibility between the invasive material and the human tissue, but also to the intensity of the magnetic field induced by the MRI system. In this study, by blending paramagnetic Ti particles with diamagnetic graphite, we synthesized $Ti_{100-x}C_x$ composites that can reduce the artifact in the MR image under the high-strength magnetic field. Of the developed composites, $Ti_{70}C_{30}$ showed the magnetic susceptibility of ${\chi}=67.6{\times}10^{-6}$, which corresponds to 30% of those of commercially available Ti alloys, the lowest reported in the literature. The level of the MR image distortion in the vicinity of the $Ti_{70}C_{30}$ composite insert was nearly negligible even under the high magnetic field of 4.7 T. In this paper, we reported on a methodology of designing new structural materials for bio-applications, their synthesis, experimental confirmation and measurement of MR images.

고온초전도체 $Y_{1-X}Sm_{X}Ba_{2}Cu_{3}O_{7-y}$의 자기적 성질 연구 (A Study on the Magnetic Properties of High $T_c$ Superconductor <$Y_{1-X}Sm_{X}Ba_{2}Cu_{3}O_{7-y}$)

  • 김채옥;김재욱;김의훈;나훈균
    • 한국재료학회지
    • /
    • 제2권3호
    • /
    • pp.197-201
    • /
    • 1992
  • 고은 초전도체 $Y_{1-X}Sm_{x}Ba_{2}Cu_{3}O_{7-y}$(x=0, 0.2, 0.4, 0.6, 0.8, 1.0)의 시료들을 제조하여 온도에 따른 자기 모우먼트를 측정하였다. 또한 자화율과 자기 임계전류밀도 같은 30K의 온도에서 자기이력 곡선으로부터 구하였다. 자화율 측정 결과로부터 고온 초전도상의 양이 14.7~49.175 범위에 있었으며, 입계전류밀도의 값은 $10^{3}~10^{4}A/cm^2$범위에 있었다. 그리고 침투깊이는 간섭성 길이보다 대략90배 정도 큼을 알 수 있었다

  • PDF

Susceptometry Application of Portable HTS SQUID-Based System

  • Timofeev, V.P.;Kim, C.G.;Shnyrkov, V.I.
    • Journal of Magnetics
    • /
    • 제3권3호
    • /
    • pp.86-88
    • /
    • 1998
  • A portable RF HTS SQUID-based susceptometer was used for small size magnetized sample testing in weak DC (up to 200A/m) and AC (up to 4 A/m) magnetic fields. The system resolution for the magnetic moment is of the order of $1.6{\times}10^{-10} A.m^2$. The measured DC susceptibility of a tested sample agrees well with the value obtained by using a commercial liquid helium susceptometer.

  • PDF

고상에피택시 YIG 박막의 온도에 따른 자기특성 (Temperature Dependence of Magnetic Properties of YIG films Grown by Solid Phase Epitaxy)

  • 장평우;김종렬
    • 한국자기학회지
    • /
    • 제15권1호
    • /
    • pp.25-29
    • /
    • 2005
  • 고상에피택시방법으로 성장한 YIG 박막의 온도에 따른 자기특성의 변화를 결정이방성과 수직이방성을 중심으로 측정하였다. 고상에피택시법의 열처리 온도가 낮을 경우 전위가 발생하여 응력을 해소함으로써 수직이방성이 유도되지 않았으나 높은 온도에서 열처리된 박막에는 우수한 에피택시성장으로 잔류응력이 축적되어 수직이방성이 유도되었다. 수직이방성자장은 기판과 박막의 열팽창계수의 차이로 결정자기이방성이 없어지는 온도까지 선형으로 감소하였고, 보자력도 온도가 증가하면 감소하였다. YIG(111) 에피택시박막에 수직이방성이 유도되었을 경우 결정이방성상수 $K_1$$H_k=4K_1/3M_s$로부터 결정할 수 있었다. 온도에 따른 초자화율의 거동은 Hopkinson 효과로 잘 설명되어졌으며 측정결과를 이용하명 상자성 자화율이 큰 기판위에 성장한 박막의 큐리온도를 쉽게 측정할 수 있었다.

STUDY OF MAGNETISM IN THE LAYERED TRANSITION METAL COMPOUND ${(C_{n}H_{2n+1}NH_{3})}_{2}CuCl_{4}\;(n=10,\;14)$

  • Lee, C.H.;Lee, K.W.;Lee, Cheol-Eui;Kang, J.K.
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.358-361
    • /
    • 1995
  • We have investigated the quasi-two-dimensional magnetism for the layered transition metal compound (C/sub n/H/sub 2n+1/NH/sub 3/)/sub 2/CuCl/sub 4/ (n=10, 14) in the high temperature regions by means of EPR (Electron Paramagnetic Resonance) and SQUID measurements. As a result, the magnetic transitions were reflected in the EPR linewidths and the magnetic suceptibilities in a sensitive manner. Fluctuations of the magnetic susceptibility and a similar variation of the .DELTA. g =(g/sub .parallel. -/g/sub .perp. /)g/sub .parallel. / value were also observed around the structural phase transition temperatures.

  • PDF