폴리에틸렌옥사이드 수용액의 정상유동 특성 (Steady Shear Flow Properties of Aqueous Poly(Ethylene Oxide) Solutions)

  • 송기원;김태훈;장갑식;안승국;이장우;이치호
    • Journal of Pharmaceutical Investigation
    • /
    • 제29권3호
    • /
    • pp.193-203
    • /
    • 1999
  • In order to investigate systematically the steady shear flow properties of aqueous po1y(ethylene oxide) (PEO) solutions having various molecular weights and concentrations, the steady flow viscosity has been measured with a Rheometrics Fluids Spectrometer (RFS II) over a wide range of shear rates. The effects of shear rate, concentration, and molecular weight on the steady shear flow properties were reported in detail from the experimentally measured data, and then the results were interpreted using the concept of a material characteristic time. In addition, some flow models describing the non-Newtonian behavior (shear-thinning characteristics) of polymeric liquids were employed to make a quantitative evaluation of the steady flow behavior, and the applicability of these models was examined by calculating the various material parameters. Main results obtained from this study can be summarized as follows: (1) At low shear rates, aqueous PEO solutions show a Newtonian viscous behavior which is independent of shear rate. At shear rate region higher than a critical shear rate, however, they exhibit a shear-thinning behavior, demonstrating a decrease in steady flow viscosity with increasing shear rate. (2) As an increase in concentration and/or molecular weight, the zero-shear viscosity is increased while the Newtonian viscous region becomes narrower. Moreover, the critical shear rate at which the transition from the Newtonian to shear-thinning behavior occurs is decreased, and the shear-thinning nature becomes more remarkable. (3) Aqueous PEO solutions show a Newtonian viscous behavior at shear rate range lower than the inverse value of a characteristic time $1/{\lambda}_E$, while they exhibit a shear-thinning behavior at shear rate range higher than $1/{\lambda}_E$. For aqueous PEO solutions having a broad molecular weight distribution, the inverse value of a characteristic time is not quantitatively equivalent to the critical shear rate, but the power-law relationship holds between the two quantities. (4) The Cross, Carreau, and Carreau-Yasuda models are all applicable to describe the steady flow behavior of aqueous PEO solutions. Among these models, the Carreau-Yasuda model has the best validity.

  • PDF

Blood Viscosity Measurements Using a Pressure-Scanning Capillary Viscometer

  • Sehyun Shin;Keum, Do-Young;Ku, Yun-Hee
    • Journal of Mechanical Science and Technology
    • /
    • 제16권12호
    • /
    • pp.1719-1724
    • /
    • 2002
  • A previously designed capillary viscometer with measuring differential pressure was modified to measure the viscosity of non-Newtonian fluids including unadulterated blood continuously over numerous shear rates in a single measurement. Because of unavoidable experimental noise and a limited number of data, the previous capillary viscometer experienced an inaccuracy and could not directly determine a viscosity without an iterative calculation. However, in the present measurement there are numerous data available near the point of interest so that the numeric value of the derivative, d(In Q)/d(In Q$\sub$w/), is no longer sensitive to the method of differentiation. In addition, relatively low and wide shear rate viscosity measurements were possible because of the present precision pressure-scanning method with respect to time. For aqueous polymer solutions, excellent agreement was found between the results from the pressure-scanning capillary viscometer and those from a commercially available rotating viscometer. In addition, the pressure-scanning capillary viscometer measured the viscosity of unadulterated whole blood without adding any anticoagulants.

과도유동현상을 이용한 모세관점도계 개발 및 적용 (Development and Application Capillary Tube Viscometer Transient Flow Concept)

  • 서상호;조민태;김동주;노형운
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.489-492
    • /
    • 2002
  • The objective of the present study were to measure the viscosities of non-Newtonian fluids by the transient flow concept in a capillary tube and to apply to hemodynamic studies and pump performance evaluations. The developed capillary tube viscometer could be used to measure the viscosities of the non-Newtonian fluids for a wide range of the shear rate by a run of experiment in a very short time interval. The measured viscosities of water and blood fur different shear rates were good agreement with those of the well established data. The measured viscosities for muddy water varied with the shear rates.

  • PDF

Slim hole 환형관내 고-액 2상 헬리컬 유동에 관한 연구 (A Study on the solid-liquid helical flow in a slim hole Annulus)

  • 우남섭;황영규;윤치호;김영주
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.465-470
    • /
    • 2006
  • An experimental investigation is carried out to study 2-phase vertically upward hydraulic transport of solid particles by water and non-Newtonian fluids in a slim hole concentric annulus with rotation of the inner cylinder. Rheology of particulate suspensions in viscoelastic fluids is of importance in many applications such as particle removal from surfaces, transport of proppants in fractured reservoir and cleaning of drilling holes, etc. In this study a clear acrylic pipe was used in order to observe the movement of solid particles. Annular fluid velocities varied from 0.2 m/s to 3.0 m/s. Pressure drops and average flow rate and particle rising velocity are measured. For both water and 0.2% CMC solutions, the higher the concentration of the solid particles is, the larger the pressure gradients become.

  • PDF

베어링 윤활 필름층의 비뉴튼성 거동에 대한 수치적 해석 (Numerical Analysis of Non-Newtonian Behavior in the Fluid Film Layer of Bearing Lubrication)

  • 김준현;김주현
    • Tribology and Lubricants
    • /
    • 제16권5호
    • /
    • pp.341-350
    • /
    • 2000
  • The study reported in this paper deals with the development for parametric investigation of the influence of the rheological properties of the lubricant in the thermohydrodynamic (THD) film conditions which occur in slider and journal bearings. A parametric investigation based on a Bingham model with a shear yield stress which best fit the experimental pressure is performed for predicting the thickness of the shear Bone in lubricating films with fixed geometry between the stationary and moving surfaces. The results suggest that the shear yield stress for the lubricating film is proportional to the pressure developed in the film within the range of the investigated cases and the shear zone thickness which is of the same order of magnitude as that obtained by the empirical formula is significantly smaller than the fluid film thickness in the lubrication zone.

축방향 하중을 받는 고속 세라믹 볼베어링에 대한 EHD 윤활영역에서의 성능 해석 (Performance Analysis of High-Speed Ceramic Ball Bearings Under Thrust Loads in EHD Lubrication)

  • 반종억;김경웅
    • Tribology and Lubricants
    • /
    • 제14권2호
    • /
    • pp.26-34
    • /
    • 1998
  • This paper presents a high-speed performance analysis of ball bearings with ceramic balls under thrust loads. The sliding velocity profiles between a ball and raceways were obtained by the 3-D quasi-dynamic equations of motion including both centrifugal force and gyroscopic moment derived by vector matrix algebra. The friction at the contact areas was obtained by the Bair-Winer's non-Newtonian rheological model and the Hamrock-Dowson's central film thickness in EHL analysis. The nonlinear equations were solved by the Newton-Raphson method and the underrelaxation iterative method. The friction torques and ball behaviors with various loads, ball materials, and contact angles were predicted by this model. It was shown that the friction torque was sensitive to thrust load and contact angle, and that the friction torque and the pitch angle of the bearing with ceramic balls are smaller than those of the bearing with steel balls.

물-미립자 현탁액의 난류 열전달 향상에 관한 수치해석적 연구 (Numerical Study about Heat Transfer Enhancement of Water-Microparticles Suspension)

  • 정세훈;손창현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권3호
    • /
    • pp.29-35
    • /
    • 2000
  • The present numerical study investigates heat transfer enhancement mechanism for suspensions of polystyrene particles in water. Numerical simulations were done for turbulent hydrodynamic fully developed flows in a circular duct with constant wall heat flux. The experimental result of microparticle suspensions show 25∼45% heat transfer enhancement over those of water. The present numerical results show the main parameter for the heat transfer enhancement of microparticle suspension in a circular duct is the change of velocity profile by the non-Newtonian fluid behavior.

  • PDF

Computational Analysis of Impulse Forces Affecting Coil Compaction in Cerebral Aneurysms

  • Cha Kyung-Se;Balaras Elias
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권3호
    • /
    • pp.94-100
    • /
    • 2006
  • The effectiveness of the treatment of intracranial aneurysms with endovascular coiling depends on coil packing density, the location of aneurysm, its neck dimensions with respect to the aneurysm dome, and its size with respect to the surrounding tissue. Clinical data also suggests that the aneurysm neck size is the main predictor of aneurysm recanalization. In this study, the force impinging on the aneurysm neck in an idealized aneurysm was calculated by using a three dimensional finite volume method for the non-Newtonian incompressible laminar flow. To quantify the effect of neck size on the impingement force, calculations were performed for aneurysm neck diameters (Da) varying from 10% to 100% of the parent artery diameter (Dp). Also, maximum impingement forces were represented by a function of the ratio of the aneurysm neck to the diameter of the parent vessel. The results show that the hemodynamic forces exerted on the coil mass at the aneurysm neck due to the pulsatile blood flow are larger for wide necked aneurysms.

Non-Newtonian Intrinsic Viscosities of Biopolymeric and Non-biopolymeric Solutions (II)

  • Jang, Chun-Hag;Kim, Chang-Hong;Ree, Taik-Yue
    • Bulletin of the Korean Chemical Society
    • /
    • 제8권4호
    • /
    • pp.332-335
    • /
    • 1987
  • This paper is a continuation of our previous $paper,^1$ and deals with Eq.(1) (see the text), which was theoretically derived in the $paper,^1$$ [{\eta}]^f\; and\; [{\eta}]^0$ is the intrinsic viscosity at stress f and f = O, respectively. Equation (1) predicts how $[{{\eta}}]^f / [{\eta}]^0$ changes with stress f, relaxation time ${\beta}_2$ of flow unit 2 and a constant $c_2$ related with the elasticity of molecular spring of flow unit 2. In this paper, Eq.(1) is applied to a biopolymer, e.g., poly (${\gamma}$-benzyl L-glutamate), and nonbiopolymers, e.g., polyisobutylene, polystyrene, polydimethylsiloxane and cellulose triacetate. It was found that the $c_2$ factor is zero for non-biopolymers while $c_2{\neq}0$ for biopolymers as found $previously.^1$ Because of the non-Newtonian nature of the solutions, the ratio $[{{\eta}}]^f / [{\eta}]^0$ drops from its unity with increasing f. We found that the smaller the ${\beta}_2,$ the larger the $f_c$ at which the viscosity ratio drops from the unity, vice versa.

전처리 농축 정도에 따른 Aloe Vera gel의 동결건조분말의 물성 (Physical Properties of Freeze-Dried Powder of Aloe Vera Gel with Respect to the Concentrating Degree as Pre-Treatment)

  • 이남재;이승주
    • 한국식품과학회지
    • /
    • 제41권1호
    • /
    • pp.32-36
    • /
    • 2009
  • 농축시킨 Aloe vera gel을 동결건조하였을 때 그 농축도 차이에 의한 최종 건조분말의 물성 변화를 비교분석하였다. 분말의 최종 수분함량은 거의 차이가 없었으며. 점성 측정에서는 높은 농축 조건의 경우 전형적인 shear thinning 현상과 non-Newtonian 유체의 속성을 나타냈다. 이에 비하여 낮은 농축 조건의 경우 Newtonian 액체의 성질과 고형분이 입자가 아닌 풀린 형태로 존재할 때 나타나는 현상을 보였다. 분말이 물에 용해되는 동안 전기전도도의 변화를 실시간으로 측정한 결과 평형상태에 도달하였을 때, 가장 높은 농축 조건에서 전기전도도가 가장 낮게 나타나, 비전해질성 물질의 용해도가 가장 큰 것으로 해석되었다. 분말의 등온흡습성에서는 농축이 증가할수록 수분 흡착과 결합수의 양이 작아지는 것으로 분석되었다. 결과적으로 Aloe vera gel을 농축하여 동결건조할 때는 그 농축도에 따라 점성, 현탁시 전기전도도에 따른 용해성, 등온흡습성이 변하는 것으로 나타나, 특정 품질의 동결건조제품을 얻기 위해서는 그에 대한 농축의 최적화가 필요한 것으로 생각된다.