• 제목/요약/키워드: a injection

검색결과 12,626건 처리시간 0.044초

실험실 규모 Cometabolic Air Sparging 공정 적용 특성 평가 : 토양 내 활성미생물 별 MTBE 분해특성 (Evaluation of the Laboratory-Scale Cometabolic Air Sparging Process : Characterization of Indigeneous Microorganism on MTBE Degradation)

  • 안상우;이시진;장순웅
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제15권1호
    • /
    • pp.1-8
    • /
    • 2010
  • Cometabolic air sparging (CAS) is a new and innovative technology that uses air sparging principles but attempts to optimize in situ contaminant degradation by adding a growth substrate to saturated zone. CAS relies on the degradation of the primary growth substrate and cometabolic substrate transformation in the saturated zone and in the vadose zone for volatilized contaminants. In this study, we have investigated to determine MTBE degradation pattern and microbial activity variation if using propane as a primary substrate at the condition of considering air injection rate and air injection pattern. Laboratory-scale two-dimentional aquifer physical model studies were used and the experimental results were represented that the optimal conditions were as air injection rate of 1,000 mL/min and pulsed air injection pattern (15 min on/off). Over 1,000 mL/min air injection rate and continuous air injection pattern was no affected to increase DO concentration. On the other hand, Injection of propane and propane-utilizing bacteria degraded MTBE partially. And also, injection of propane- and MTBE-utilizing bacteria effectively degraded MTBE and TBA production was observed.

적접분사식 LPG엔진에서 연료분사압력이 연소/배기특성에 미치는 영향 연구 (Effects of Injection Pressures on Combustion and Emissions in a Direct Injection LPG Spark Ignition Engine)

  • 이석환;조준호;오승묵
    • 한국분무공학회지
    • /
    • 제16권1호
    • /
    • pp.7-14
    • /
    • 2011
  • High pressure LPG fuel spray with a conventional swirl injector was visualized and the impact of the injection pressure was also investigated using a DISI (direct injection spark ignition) LPG single cylinder engine. Engine performance and emission characteristics were evaluated over three different injection pressure and engine loads at an engine speed of 1500 rpm. The fuel spray pattern appeared to notably have longer penetration length and narrower spray angle than those of gasoline due to its lower angular momentum and rapid vaporization. Fuel injection pressure did not affect combustion behaviors but for high injection pressure and low load condition ($P_{inj}$=120 bar and 2 bar IMEP), which was expected weak flow field configuration and low pressure inside the cylinder. In terms of nano particle formation the positions of peak values in particle size distributions were not also changed regardless of the injection pressure, and its number densities were dramatically reduced compared to those of gasoline.

Comparisons between fresh and cryopreserved fat injections in facial lipofilling

  • Yang, Hyee Jae;Kang, Sang Yoon
    • 대한두개안면성형외과학회지
    • /
    • 제21권1호
    • /
    • pp.15-21
    • /
    • 2020
  • Background: Autologous fat is considered an ideal filler material, and the use of cryopreserved fat grafts is promising in terms of flexibility and efficiency. Therefore, cryopreserved fat grafts have become more common in recent years; however, their complications require further consideration. Methods: We evaluated 53 patients who underwent facial lipofilling at our institution to confirm the clinical usefulness and safety of cryopreserved fat. Fresh fat injections with or without cryopreserved fat were administered. At one or more sites, 22 patients had a single fresh fat injection, four patients had two or more fresh fat injections, 16 patients had one fresh fat injection followed by one cryopreserved fat injection, six patients had one fresh fat injection followed by two cryopreserved fat injections, and five patients had two fresh fat injections and one or more cryopreserved fat injections. Results: In total, 281 sets of injection procedures were performed at various sites, of which 170 involved one fresh fat injection, 89 involved one fresh fat injection and one cryopreserved fat injection, and 11 involved one fresh fat injection and two cryopreserved fat injections. One patient experienced self-resolving inflammation as a complication after the second injection in the right cheek. No statistically significant differences were found between the fresh and cryopreserved fat injections. Conclusion: We suggest that cryopreserved fat is a useful and safe resource for multiple fat injections, with advantages including aseptic fat handling and the delicacy of the technique.

분사조건변환기에 따른 인젝터 성능 분석 시스템 개발 (A Development of Injector Performance Analysis System by Injection Condition Converter)

  • 손일문;이중순
    • 한국분무공학회지
    • /
    • 제11권4호
    • /
    • pp.228-233
    • /
    • 2006
  • There are two types of electric controlled fuel injection system in the gasoline engines of common vehicles. One is fuel return system and the other is fuel returnless system according to the methods of controlling injection pressures. It is important to understand the characteristics of these system in loaming and studying of engine, but it is very difficult without a special equipment in reality. The purpose of this paper is to develop the emulation system that can be compensated with the amount of injection fuel according to various driving conditions, battery voltage, cooling water temperature, and engine speed, may be appeared in real driving, and especially can analyze the difference between the electric signal controlling the amount of injection fuel and its result, and nullity injection duration. With the developed system, we can conveniently set various and completed driving condition and so can acquire the useful information such as non-uniformity rate and mass of injection fuel using waveform analysis and measurement modules. It must be a very useful and sophisticated system to instruct and learn the features and operating states of injection system, and to study f3r improving the performance of it.

  • PDF

A Comparison of Two Techniques for Ultrasound-guided Caudal Injection: The Influence of the Depth of the Inserted Needle on Caudal Block

  • Doo, A Ram;Kim, Jin Wan;Lee, Ji Hye;Han, Young Jin;Son, Ji Seon
    • The Korean Journal of Pain
    • /
    • 제28권2호
    • /
    • pp.122-128
    • /
    • 2015
  • Background: Caudal epidural injections have been commonly performed in patients with low back pain and radiculopathy. Although caudal injection has generally been accepted as a safe procedure, serious complications such as inadvertent intravascular injection and dural puncture can occur. The present prospective study was designed to investigate the influence of the depth of the inserted needle on the success rate of caudal epidural blocks. Methods: A total of 49 adults scheduled to receive caudal epidural injections were randomly divided into 2 groups: Group 1 to receive the caudal injection through a conventional method, i.e., caudal injection after advancement of the needle 1 cm into the sacral canal (n = 25), and Group 2 to receive the injection through a new method, i.e., injection right after penetrating the sacrococcygeal ligament (n = 24). Ultrasound was used to identify the sacral hiatus and to achieve accurate needle placement according to the allocated groups. Contrast dyed fluoroscopy was obtained to evaluate the epidural spread of injected materials and to monitor the possible complications. Results: The success rates of the caudal injections were 68.0% in Group 1 and 95.8% in Group 2 (P = 0.023). The incidences of intravascular injections were 24.0% in Group 1 and 0% in Group 2 (P = 0.022). No intrathecal injection was found in either of the two groups. Conclusions: The new caudal epidural injection technique tested in this study is a reliable alternative, with a higher success rate and lower risk of accidental intravascular injection than the conventional technique.

Minimize Web Applications Vulnerabilities through the Early Detection of CRLF Injection

  • Md. Mijanur Rahman;Md. Asibul Hasan
    • International Journal of Computer Science & Network Security
    • /
    • 제23권2호
    • /
    • pp.199-202
    • /
    • 2023
  • Carriage return (CR) and line feed (LF), also known as CRLF injection is a type of vulnerability that allows a hacker to enter special characters into a web application, altering its operation or confusing the administrator. Log poisoning and HTTP response splitting are two prominent harmful uses of this technique. Additionally, CRLF injection can be used by an attacker to exploit other vulnerabilities, such as cross-site scripting (XSS). Email injection, also known as email header injection, is another way that can be used to modify the behavior of emails. The Open Web Application Security Project (OWASP) is an organization that studies vulnerabilities and ranks them based on their level of risk. According to OWASP, CRLF vulnerabilities are among the top 10 vulnerabilities and are a type of injection attack. Automated testing can help to quickly identify CRLF vulnerabilities, and is particularly useful for companies to test their applications before releasing them. However, CRLF vulnerabilities can also lead to the discovery of other high-risk vulnerabilities, and it fosters a better approach to mitigate CRLF vulnerabilities in the early stage and help secure applications against known vulnerabilities. Although there has been a significant amount of research on other types of injection attacks, such as Structure Query Language Injection (SQL Injection). There has been less research on CRLF vulnerabilities and how to detect them with automated testing. There is room for further research to be done on this subject matter in order to develop creative solutions to problems. It will also help to reduce false positive alerts by checking the header response of each request. Security automation is an important issue for companies trying to protect themselves against security threats. Automated alerts from security systems can provide a quicker and more accurate understanding of potential vulnerabilities and can help to reduce false positive alerts. Despite the extensive research on various types of vulnerabilities in web applications, CRLF vulnerabilities have only recently been included in the research. Utilizing automated testing as a recurring task can assist companies in receiving consistent updates about their systems and enhance their security.

ELK Stack을 활용한 SQL Injection 로그 탐지 (Detecting SQL Injection Logs Leveraging ELK Stack)

  • 민송하;유현재;임문주;김종민
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 추계학술대회
    • /
    • pp.337-340
    • /
    • 2022
  • SQL Injection 공격은 오래된 공격기법 중 하나로 웹 서비스에 대한 해킹 시도 유형 중에서도 높은 비중을 차지하고 있다. SQL Injection 공격은 데이터 노출 및 권한획득 등의 방법으로 현재까지도 해킹 시도가 많이 발생하고 있으며, 본 논문에서는 오픈소스인 ELK Stack을 활용하여 실시간으로 SQL Injection 공격 대응할 수 있는 로그 분석시스템을 구현하였다. 구현한 시스템을 통해 SQL Injection 공격에 대한 로그 데이터를 시각화하여 제공함으로써, 사용자는 공격의 위험도를 쉽게 파악할 수 있으며 신속하게 공격에 대비할 수 있을 것으로 기대한다.

  • PDF

녹용약침과 웅담.우황(BU)약침이 정상인의 심박변이도(HRV)에 미치는 영향 (The Effects of Cervi Pantotrichum Cornu Pharmacopuncture and Bovis calculus.Fel Ursi Pharmacopuncture on the Heart Rate Variability)

  • 이휘용;이진복;조이현;송범용;육태한
    • Journal of Acupuncture Research
    • /
    • 제27권1호
    • /
    • pp.65-74
    • /
    • 2010
  • Objectives : This study was to investigate the effects of Cervi Pantotrichum Cornu Pharmacopuncture and Bovis calculus Fel Ursi Pharmacopuncture on autonomic nervous system with Heart Rate Variability(HRV). Purpose of the trial was to observe what influence Cervi Pantotrichum Cornu Pharmacopuncture and Bovis calculus Fel Ursi pharmacopuncture have on the autonomic nervous system. Methods : 40 healthy male volunteers were divided into two experimental groups, such as Cervi Pantotrichum Cornu Pharmacopuncture group and Bovis calculus Fel Ursi Pharmacopuncture group. Study design was a randomized, double-blind clinical trial. 20 subjects in one experimental group were injected Cervi Pantotrichum Cornu Pharmacopuncture, 20 subjects in other experimental group were injected hydrolyzed Bovis calculus Fel Ursi Pharmacopuncture at GB21(Kyonjong). We measured HRV 7 times : baseline measurement and every 5 minutes for 30 minutes after injection. The SPSS 15.0 for Windows was used to analyze the data by the paired t-test(in group) and independent sample t-test(between the groups). Results A. Time Domain Analysis 1. Analysis of Mean HRV, SDNN and Complexity After injection of Cervi Pantotrichum Cornu Pharmacopuncture, Mean HRV was significantly decreased all the times after injection. SDNN was significantly increased at immediate and 25 minute after injection. Complexity was significantly decreased only at 15 minute after injection. After injection of Bovis calculus Fel Ursi Pharmacopuncture, Mean HRV was significantly decreased all the times after injection. Complexity was significantly decreased at 15 minutes after injection. 2. Analysis of HRV index, pNN50 After injection of Cervi Pantotrichum Cornu Pharmacopuncture, HRV index was significantly increased immediately after injection. pNN50 was significantly decreased at immediately, 20 and 25 minutes after injection. After injection of Bovis calculus Fel Ursi Pharmacopuncture, HRV index was significantly increased immediately after injection. pNN50 was significantly decreased at immediate and 25 minutes after injection. B. Frequency Domain Analysis 1. Analysis of Ln(TP), Ln(HF), Ln(LF), Ln(VLF) After injection of Cervi Pantotrichum Cornu Pharmacopuncture, Ln(TP) was significantly increased at immediate and 25 after injection. Ln(HF) was significantly increased all the times after injection. Ln(LF) was significantly increased at 15, 20 and 25 minutes after injection. Ln(VLF) was significantly increased at immediate and 25 minutes after injection. After injection of Bovis calculus Fel Ursi Pharmacopuncture, Ln(TP) was significantly increased at immediately and 25 after injection. Ln(LF) was significantly increased at 20 and 25 minutes after injection. Ln(VLF) was significantly increased at immediate and 25 minutes after injection. Conclusions : We results suggest that Cervi Pantotrichum Cornu Pharmacopuncture and Bovis calculus Fel Ursi Pharmacopuncture in healthy adult men tend to activate the autonomic nervous system and sympathetic nervous system within normal range.

PC 기반 PLC를 이용한 사출성형기 배럴의 퍼지 온도 제어에 관한 연구 (A Study on Fuzzy Temperature Control for the Barrels of Injection Molding Machine using PC based PLC)

  • 김훈모
    • 제어로봇시스템학회논문지
    • /
    • 제9권10호
    • /
    • pp.768-773
    • /
    • 2003
  • Injection molding has been widely used for the mass production of a plastic product. With the development of the relative technique, various injection molding techniques have been developed and we could get more precise plastic product. The temperature of a melting resin is an important factor in the injection molding and this temperature has direct influence on the quality of a plastic product. In the present injection molding machine, the deriation of a temperature controlled by PID control method is within 2$^{\circ}C$ in the injection molding machine but PID control method takes too much time to stabilize after preheating and its overshoot is so big. We applied fuzzy control to alleriate the problem. In this research, we experimented the fuzzy temperature control with the usage of PC based PLC.

Design of Gate System in Injection Molding of a Dashboard by CAMPmold

  • Choi D. S.;Han K. H.;Kim H. S.;Im Y. T.
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 The Korea-Japan Plastics Processing Joint Seminar
    • /
    • pp.33-39
    • /
    • 2003
  • Injection molding is widely used in producing various plastic parts due to its high productivity and the demand for high precision injection molded products is ever increasing. To achieve successful product quality and precision, the design of gating and runner systems in the injection mold is very important since it directly influences melt flow into the cavity. Some defects such as weld lines and overpacking can be effectively controlled with proper selection of gate locations. In the present study, the design of gate locations in injection molding of a dashboard for automobiles was carried out with CAMPmold, a PC-based simulation system for injection molding. A dummy runner was developed to simulate a runner system in order to increase the efficiency of the analysis. The numbers and locations of gates were varied in the present investigation as that an acceptable design was obtained in terms of reduced maximum pressure and clamping force.

  • PDF