• Title/Summary/Keyword: a horizontal plane

Search Result 654, Processing Time 0.027 seconds

An Analytical Traffic Model of Control Plane and Application Plane in Software-Defined Networking based on Queuing Theory (대기행렬 이론 기반 SDN 제어 평면 및 응용 평면의 트래픽 성능 분석 모델)

  • Lee, Seungwoon;Roh, Byeong-hee
    • The Journal of Korean Institute of Next Generation Computing
    • /
    • v.15 no.4
    • /
    • pp.80-88
    • /
    • 2019
  • Software Defined Networking (SDN) is the future network paradigm of decoupling control and data functions. In SDN structure, it is hard to address scalability in case of large-scale networks because single controller managed thousands of switches in a centralized fashion. Most of previous studies have focused on horizontal scalability, where distributed controllers are assigned to network devices. However, they have abstracted the control plane and the application plane into a single controller. The layer of the common SDN architecture is divided into data plane, control plane, and application plane, but the control plane and application plane have been modeled as a single controller although they are logically separated. In this paper, we propose a analytical traffic model considering the both application plane and control plane based on queuing theory. This model can be used to address scalability issues such as controller placement problem without complicated simulations.

Visible Wavelength Photonic Insulator for Enhancing LED Light Emission

  • Ryoo, Kwangki;Lee, Jeong Bong
    • Journal of information and communication convergence engineering
    • /
    • v.13 no.1
    • /
    • pp.50-55
    • /
    • 2015
  • We report design and simulation of a two-dimensional (2D) silicon-based nanophotonic crystal as an optical insulator to enhance the light emission efficiency of light-emitting diodes (LEDs). The device was designed in a manner that a triangular array silicon photonic crystal light insulator has a square trench in the middle where LED can be placed. By varying the normalized radius in the range of 0.3-0.5 using plane wave expansion method (PWEM), we found that the normalized radius of 0.45 creates a large band gap for transverse electric (TE) polarization. Subsequently a series of light propagation simulation were carried out using 2D and three-dimensional (3D) finite-difference time-domain (FDTD). The designed silicon-based light insulator device shows optical characteristics of a region in which light propagation was forbidden in the horizontal plane for TE light with most of the visible light spectrum in the wavelength range of 450 nm to 600 nm.

Hydrodynamic Characteristics of Stratified Flow at a Y-Junction (Y자형 혼합지점에서의 성층류유동 특성)

  • ;;Lee, Sang Yong
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.12
    • /
    • pp.3360-3371
    • /
    • 1995
  • Hydrodynamic characteristics of a stratified flow at a Y-junction were examined analytically. Gas is supplied through the main horizontal channel and liquid is introduced into the gas stream from the Y-shaped bottom branch. Analysis was performed with irrational flow and inviscid fluid assumptions. The Stokes' inverse transformation technique was adopted to convert the real x-y plane into the x-.psi. plane. The potential flow equation was solved numerically in the transformed (x-.psi.) plane and the interface profile, pressure distribution and the streamlines were obtained. The effects of the inlet conditions, injection angle and the gravity on the flow characteristics were also examined. To check the validity of the present method, the previous resultant the two-dimensional obtuse wedge flow was compared. The inverse transformation technique turned out to be also very useful to predict the hydrodynamic characteristics of a stratified flow with the pressure variation at a Y-shaped mixing junction.

A COMPARATIVE STUDY ON THE REPRODUCIBILITY AND THE DISPLACEMENT OF CENTRIC RELATION RECORDS (BETWEEN LEAF GAUGES AND OTHER METHODS) (하악 중심위 유도방법에 따른 하악위의 재현성 및 변위량에 관한 비교연구(LEAF GAUGES의 사용을 중심으로))

  • Choi, Jin-Woong;Choi, Dae-Gyun;Park, Nam-Soo;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.26 no.1
    • /
    • pp.133-151
    • /
    • 1988
  • The objectives of this study were to compare the position of centric relation guided by means of leaf gauges, bilateral manipulation, chin-point guidance with Lucia jig and self-guided method and the reproducibility, respectively. A Veri-check (Denar Co., Anaheim, California) was employed for examining, and the displacement of position and reproducibility were verified. The following results were obtained. 1. On the sagittal plane, the centric relation guided by means of leaf gauges showed greater posterior displacement than that by means of bilateral manipulation and less than that by means of chin-point guidance with Lucia jig, and self-guided centric relation showed least posterior displacement. The centric relation guided by means of bilateral manipulation showed greater superior displacement than that by means of chin-point guidance with Lucia jig and less than that by means of leaf gauges and self-guided centric relation showed least superior displacement. 2. On the horizontal plane, the centric relation guided by means of chin-point guidance with Lucia jig showed greater posterior displacement than that of bilateral manipulation and less than that leaf gauges, however the self-guided centric relation showed slightly anterior displacement. 3. The anteroposterior displacement measured on sagittal plane and horizontal plane were highly correlated. (p<0.05). 4. The reproducibility of centric relation guided by means of leaf gauges, bilateral manipulation and chin-point guidance with Lucia jig were similar and more reproducible than self-guided centric relation.

  • PDF

A Study on the Mandibular Movements in the Patients with TMJ Lock Closed -Range and pattern of mandibulr movement- (악관절 폐구성 과두걸림 환자의 하악운동에 관한 연구 -치료전후의 하악운동 범위 및 양상 -)

  • Sung-Chang Chung;Hyung-Suk Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.16 no.1
    • /
    • pp.113-120
    • /
    • 1991
  • The authors examined the patterns and various ranges of mandibular movements in TMJ lock closed patients in the frontal, sagittal and horizontal plane pre-end post-treatment. And the author obtained the following results. 1. In the frontal plane, the patterns and ranges of mandibular movement of the patients were very irregular and small before treatment. But after the treatment, the patterns were similar to the typical shield shape of the normal subjects. And the velocity of opening and closing was improved after the treatment. 2. In the sagittal plane, the mean amount of maximum mouth opening was 27.0±4.0mm before treatment and 44.0±5.4mm after treatment. And there was statistically significant improvement(p<0.005). The patterns of the movement were very irregular and small before treatment, but were similar to the shape of "Posselt's envelope of motion" after the treatment. The velocity of opening and closing was improved after the treatment 3. In the horizontal plane, the mean amount of maximum laterotrusion was 8l2±2.5mm in the affected side and 6.7±2.2mm in the non-affected side before treatment. There was a significant difference between the sides(p<0.05). After the treatment, the mean was 10.4±2.6mm in the affected side and 8.9±2.3mm in the non-affected side and there was no significant difference between the sides(p>0.05). There was no significant difference in the mean amount of maximum protrusion between the before and aftertreatment(p>0.05), but the patterns of the movements were improved.

  • PDF

A Conical-Cylindrical Monopole Antenna

  • Jeong, Hye-Mi;Park, Seong-Bae;Kim, Choon-Won;Sodnomtseren, Ononchimeg;Bang, Jai-Hoon;Ahn, Biemg-Chearl
    • Journal of electromagnetic engineering and science
    • /
    • v.7 no.3
    • /
    • pp.138-146
    • /
    • 2007
  • In this paper, a monopole antenna of conical-cylindrical compound shape is presented. The conventional circular conical monopole antenna is modified by placing a cylinder at the top of the inverted cone. The cylindrical portion is useful in the wide band impedance matching, in adjusting the antenna gain in the horizontal direction, and in reducing the cone diameter. The dependence of the antenna performance on various geometric parameters is investigated using a commercial electromagnetic simulation software, from which an optimum design of the antenna is derived. The diameter of the circular ground plane is minimized to 115 wavelength at the lowest operating frequency. The antenna proposed in this study shows a reflection coefficient less than -10 dB and a 1${\sim}$6 dBi gain over 3${\sim}$20 GHz frequencies. The antenna shows a circular-symmetric radiation pattern in the horizontal plane and a null-free pattern in the vertical direction over the whole operating frequency range.

Characteristics of Walls Supported by Prefabricated Strut (조립식 버팀보로 지지된 흙막이 구조물의 거동 특성에 관한 연구)

  • 김낙경;박종식
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.553-560
    • /
    • 2003
  • From the analytical standpoint, it is advantageous to consider the behavior of supported walls as plane strain condition. But supported walls constitute geotechnical problems which, in strut terms, are not plane strain cases. These represent differences between the measured and the predicted due to the stiffness and spacing of supported walls and the behavior of discontinuous walls such as solider beams with lagging. This study is to investigate simulations of a system behavior along a horizontal section of walls supported by prefabricated strut. Using a beam column method, relative effects associated with prefabricated strut stiffness and spacing in a systematic behavior were investigated.

  • PDF

THE STUDY OF TECHNICAL FAILURE OF INTRAORAL ROENTGENOGRAPHY (국내 X-선 촬영술에 있어서 실패의 원인분석에 관한 연구)

  • Kang Yong Sang
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.7 no.1
    • /
    • pp.27-30
    • /
    • 1977
  • To insure accuracy in dental roentgenographs, it is important that the patient's head position and angulation of the x-ray tube. In 1907 Cieszynski applied the rule of isometry to dental radiography and established that in the production of an accurate image of a tooth, the central ray must be porjected perpendicularly to a plane bisecting angle formed by the longitudinal axis of the tooth and the film plane. Proper exposure of the film is a part of the production of a good dental radiograph, and correct processing also makes an essential contribution to the quality of the radiograph. The author analysed the failure of exposure and processing results, and recommended followings. 1. The patient head must be positioned that occlusal plane are parallel with the horizontal floor. 2. Central ray must be projected to the objective tooth and supporting structure and projected as perpendicularly to tooth axis and film surface as possible. 3. In processing, the temperature of the solution and the processing time must be correct.

  • PDF

Plane-wave Full Waveform Inversion Using Distributed Acoustic Sensing Data in an Elastic Medium (탄성매질에서의 분포형 음향 센싱 자료를 활용한 평면파 전파형역산)

  • Seoje, Jeong;Wookeen, Chung;Sungryul, Shin;Sumin, Kim
    • Geophysics and Geophysical Exploration
    • /
    • v.25 no.4
    • /
    • pp.214-216
    • /
    • 2022
  • Distributed acoustic sensing (DAS), an increasingly growing acquisition technique in the oil and gas exploration and seismology fields, has been used to record seismic signals using optical cables as receivers. With the development of imaging methods for DAS data, full waveform inversion (FWI) is been applied to DAS data to obtain high-resolution property models such as P- and S-velocity. However, because the DAS systems measure strain from the phase distortion between two points along optical cables, DAS data must be transformed from strain to particle velocity for FWI algorithms. In this study, a plane-wave FWI algorithm based on the relationship between strain and horizontal particle velocity in the plane-wave assumption is proposed to apply FWI to DAS data. Under the plane-wave assumption, strain equals the horizontal particle velocity, which is scaled by the velocity at the receiver position. This relationship was confirmed using a numerical experiment. Furthermore, 4-layer and modified Marmousi-2 velocity models were used to verify the applicability of the proposed FWI algorithm in various survey environments. The proposed FWI was implemented in land and marine survey environments and provided high-resolution P- and S-velocity models.

THE COMPARATIVE STUDY FOR OCCLUSAL PLANE BETWEEN ARTICULATED CAST MODEL AND CEPHALOGRAM IN ORTHOGANTIHIC SURGERY PATIENTS (악교정수술 환자에서 교합기 석고 모형과 측면두부방사선사진의 교합평면에 관한 비교 연구)

  • Seo, Kyung-Suk;Park, Mi-Hwa;Lee, Ju-Hyun;Kim, Chul-Hwan;Chae, Jong-Moon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.4
    • /
    • pp.239-244
    • /
    • 2003
  • The common errors in preoperative treatment plan for the orthognathic surgery can be occurred during cast impression, cast mounting procedure with face-bow transfer, surgical stent fabrication, and so on. One of the most common errors exists during mounting process of the model on the articulator. Accurate mounting of dental casts to articulator should be achieved by transferring the 3-dimensional spatial relationship of the maxillary arch to an articulator. A face-bow is used for transfer this relationship to articulator, usually by relating the face-bow to a plane of reference of maxillary cast. The purpose of this study is evaluation of the accuracy of face-bow transferring of maxillary model to the articulator. The maxillary casts of thirty patients for orthognathic surgery were mounted on articulator with an face-bow instrument. The relationship of occlusal plane angle to Frankfort horizontal plane relations were compared the cephalogram with the cast-mounted articulator. As a result of this study, the significant difference between the maxillary occlusal planes angle in the cephalogram and articulator were found. The results were followed, 1. The mean occlusal plane angle in cast-mounted articulator was $13.5^{\circ}\;(SD{\pm}5.4)$. 2. The mean occlusal plane angle in cephalogram was $10.4^{\circ}\;(SD{\pm}4.3)$. 3. The mean difference of occlusal plane angle between cast-mounted articulator and cephalogram was $3.3^{\circ}\;(SD{\pm}4.6)$. According to the result, we should suggest that the occlusal plane angle to Frankfort plane in cast-mounted articulator is more steeper than that of cephalogram. And then, maxillofacial surgeon should try to get a more predictable result by suggesting the proper correction method and mounting the cast accurately.