• Title/Summary/Keyword: a gas meter for leakage inspection

Search Result 2, Processing Time 0.018 seconds

A Study on the Improvement of Leak Alarm Reliability of Gas Meter for Leak Inspection according to Boiler Usage Pattern (보일러 사용 패턴에 따른 누출점검용 가스계량기 누출 알람 신뢰도 개선 연구)

  • Jin-Du Yang;Seung-Won Lee;Eun-Il Choi;Sung-Hyeon Lim
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.3
    • /
    • pp.72-76
    • /
    • 2023
  • Among urban gas-using facilities, more and more cases are using gas meters for leakage inspection instead of inspection ports for concealment pipes. Leak alarm alarms were continuously generated according to the boiler's special usage pattern in an environment where there was no actual gas leakage among some households where this meter was installed. It does not perform its original function of detecting actual gas leakage. Based on these problems, this study analyzed the conditions under which the gas meter for leakage inspection generates leakage alarms according to the boiler's special gas use pattern, and sought a set value that can generate an alarm only in the case of actual gas leakage. Through this, it is intended to relieve citizens' anxiety about gas use due to malfunction of the alarm and at the same time perform the original function of the meter that can detect leaking gas.

The Measurement Error owing to Leakage of Gaugeline in Orifice Flowmeter (오리피스 유량계에서 게이지라인 누설에 의한 계량오차)

  • Lee, Cheol-Gu;Ha, Young-Chul;Her, Jae-Young
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.143-148
    • /
    • 2003
  • This study was experimentally performed in order to estimate the errors due to the leakage of transmitter gaugelines in the orifice flow meter for natural gas. It would be a serious problem in safety if a large quantity of leak was occurred at the tubes or fittings like valve. But in most cases the safety problems might be rarely happened because the gas leak detectors could be operated in advance and the various kinds of inspection would be also fulfilled periodically. If the leakage was occurred continuously with an undetectable amount at the gaugelines for measuring the pressure or the differential pressure(DP), the amount of leakage might be an error or an unaccounted flow(UAE). In addition if the measuring value of pressure or DP were affected by the leakage, it might also be a measurement error. The experiments were performed to estimate the amount of leakage and to check the DP changes if it exited. First, through the measurement of the air pressure changes in the airtight container connected to a transmitter with gaugelines as the time passed, the amount of leakage causing from the fittings of gaugelines was roughly estimated. As changing the leak position of the gaugeline, the leak was intentionally made to break out. The variance of DP was checked as controlling the extent of leakage and compared to no leak conditions. Consequently, under the normal maintenance conditions, the result represented that the amount of leakage causing from the gaugelines was insignificant and also the DP changes on leakage conditions were too small to cause the errors of measurements.

  • PDF