• 제목/요약/키워드: a frequency response

검색결과 4,797건 처리시간 0.038초

공간 응답 변화량을 적용한 광대역 빔 형성기 설계법 (A study on the broadband beam pattern synthesis using spatial response variation)

  • 임준석;이근화;안재균
    • 한국음향학회지
    • /
    • 제39권3호
    • /
    • pp.200-206
    • /
    • 2020
  • 본 논문은 공간 응답 변화량(Spatial Response Variation, SRV)을 사용한 광대역 빔 형성 방법을 제안한다. SRV를 정규화 항으로 적용하여 목표하는 주파수 대역에서 주 빔 폭의 변동이 약 1도 이내로 적은 양질의 광대역 빔패턴을 얻도록 하였다. 설계 실험에서 제안 된 방법이 기존 방법보다 낫다는 것을 입증하였다.

비고전적으로 감쇠하는 선형 진동시스템의 주파수응답 (Frequency Response of Nonclassically Damped Linear Systems)

  • 황재혁;남창호
    • 대한기계학회논문집
    • /
    • 제17권11호
    • /
    • pp.2742-2751
    • /
    • 1993
  • Nonclassically damping domes from drastic variations of energy absorption rates of the materials in different parts of structures, or from the external damping sources inserted into the structures. In this study, an approximate method to calculate the frequency response of a method is superior to other approaches in respect of computational effort and accuracy. In addition, when frequency response is calculated by neglecting the off-diagonal elements of modal damping matrix, a criterion to ensure small errors is derived. In is shown that the criterion can be described as the vector sum of each modal coupling to the corresponding mode.

Approximate Equivalent-Circuit Modeling and Analysis of Type-II Resonant Immittance Converters

  • Borage, Mangesh;Nagesh, K.V.;Bhatia, M.S.;Tiwari, Sunil
    • Journal of Power Electronics
    • /
    • 제12권2호
    • /
    • pp.317-325
    • /
    • 2012
  • Resonant immittance converter (RIC) topologies can transform a current source into a voltage source (Type-I RICs) and vice versa (Type-II RICs), thereby making them suitable for many power electronics applications. RICs are operated at a fixed frequency where the resonant immittance network (RIN) exhibits immittance conversion characteristics. It is observed that the low-frequency response of Type-II RINs is relatively flat and that the state variables associated with Type-II RINs affect the response only at the high frequencies in the vicinity of the switching frequency. The overall response of a Type-II RIC is thus dominated by the filter response, which is particularly important for the controller design. Therefore, an approximate equivalent circuit model and a small-signal model of Type-II RICs are proposed in this paper, neglecting the high-frequency response of Type-II RINs. While the proposed models greatly simplify and speed-up the analysis, it adequately predicts the open-loop transient and small-signal ac behavior of Type-II RICs. The validity of the proposed models is confirmed by comparisons of their results with those obtained from a cycle-by-cycle simulation and with an experimental prototype.

Evaluation of MCC seismic response according to the frequency contents through the shake table test

  • Chang, Sung-Jin;Jeong, Young-Soo;Eem, Seung-Hyun;Choi, In-Kil;Park, Dong-Uk
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1345-1356
    • /
    • 2021
  • Damage to nuclear power plants causes human casualties and environmental disasters. There are electrical facilities that control safety-related devices in nuclear power plants, and seismic performance is required for them. The 2016 Gyeongju earthquake had many high-frequency components. Therefore, there is a high possibility that an earthquake involving many high frequency components will occur in South Korea. As such, it is necessary to examine the safety of nuclear power plants against an earthquake with many high-frequency components. In this study, the shaking table test of electrical facilities was conducted against the design earthquake for nuclear power plants with a large low-frequency components and an earthquake with a large high-frequency components. The response characteristics of the earthquake with a large high-frequency components were identified by deriving the amplification factors of the response through the shaking table test. In addition, safety of electrical facility against the two aforementioned types of earthquakes with different seismic characteristics was confirmed through limit-state seismic tests. The electrical facility that was performed to the shaking table test in this study was a motor control center (MCC).

Experimental Examination of Multivariable PID Controller Design on Frequency Domain using Liquid Level Process

  • Eguchi, Kazuki;Iwai, Zenta;Mizumoto, Ikuro;Kumon, Makoto
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.786-791
    • /
    • 2005
  • This paper is concerned with the examination and evaluation concerning a tuning method of multivariable PID controllers based on partial model matching on frequency domain proposed by authors from practical view point. In this case, PID controller parameters are determined by minimizing the loss function defined by the difference between frequency response of ideal model transfer function and actual frequency response on several frequency points. The purpose of the paper is to examine and evaluate the performance of the method through actual experiments of MIMO liquid level experimental process control equipment.

  • PDF

연속교 적용을 위한 양단고정지지 보의 진동수 기반 충격계수 응답스펙트럼 개발 (Development of Impact Factor Response Spectrum based on Frequency Response of Both Ends-Fixed Beam for Application to Continuous Bridges)

  • 노화성;이후석;박경훈
    • 한국산학기술학회논문지
    • /
    • 제17권12호
    • /
    • pp.301-306
    • /
    • 2016
  • 교량의 내하성능 추정 관련 연구에서 단순지지 조건의 충격계수 응답스펙트럼을 개발하고 이를 적용한 새로운 단순교의 내하력 평가 모델이 제안되었다. 본 논문에서는 충격계수 응답스펙트럼을 연속교에 적용하기 위해 연속지지 경간 중 내측 경간의 경계조건을 이상적인 양단 고정 경계조건으로 가정하고, 보의 동적 지배방정식을 이용하여 보 중앙에서의 이론적인 최대 통적 및 정적 연위 산출식과 이로부터 충격계수 이론식을 유도하였다. 이론식을 바탕으로 교량 경간 길이 및 감쇠비에 따른 양단지지 조건의 충격계수 응답스펙트럼을 개발하였다. 제안된 충격계수 응답스펙트럼의 적용성을 검증하기 실제공용 중인 연속교를 대상으로 수치해석을 수행하고 실측 데이터와 비교하였다. 해석은 실측 데이터와 동일하게 6경간 연속교에 차량 하중을 이동 재하 하였으며, 연속지지 내부 경간에서 동적응답을 측정하였다. 교량의 진동수는 가속도 응답을 고속퓨리에 변환(FFT)하여 얻었으며, 제안된 응답스펙트럼으로부터 교량의 경간-진동수를 적용하여 충격계수를 도출하였다. 제안된 모델에 의한 충격계수는 실측 충격계수 유사한 결과를 나타냈으며, 양단고정지지 교량의 진동수 기반 충격계수 응답스펙트럼을 이용한 방법은 실재 연속교에 적용 가능할 것으로 판단된다.

VCM(voice coil motor)를 이용한 3차원 나노 형상 측정 시스템 (3-D Nano Topology Measurement using VCM)

  • 정종규;염우섭;박기환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1439-1443
    • /
    • 2007
  • In this paper, vibration reduction techniques of a voice coil motor (VCM) actuator are presented for AFM imaging system. The damping coefficient of the actuator driven by VCM with a flexure hinge is quite low and it cause the about 30dB peak amplitude response at the resonance frequency. To decrease this peak response, we design and apply elliptical band-stop filters to xy and z axis VCM actuator. Frequency response of each actuator with filter is measured to verify the effect of the filters. As a sensor, capacitive sensor is used. Vibration reduction rate of the xy actuator with the filter is also measured while real AFM scanning condition. As another method, closed loop control with the capacitive sensor is applied to the xy axis actuator to add an electrical damping effect and vibration reduction rate measured. These vibration reduction rates with each method are compared. In the case of z axis actuator, the frequency response of force (gap) control loop is measured. For comparison, the frequency response using a conventional PID controller is also obtained. Finally, the AFM image of a standard grid sample is measured with the designed controller to analyze the effect in the AFM imaging.

  • PDF

Seismic response analysis of layered soils considering effect of surcharge mass using HFTD approach. Part II: Nonlinear HFTD and numerical examples

  • Saffarian, Mohammad A.;Bagheripour, Mohammad H.
    • Geomechanics and Engineering
    • /
    • 제6권6호
    • /
    • pp.531-544
    • /
    • 2014
  • Studies of earthquakes over the last 50 years and the examination of dynamic soil behavior reveal that soil behavior is highly nonlinear and hysteretic even at small strains. Nonlinear behavior of soils during a seismic event has a predominant role in current site response analysis approaches. Common approaches to ground response analysis include linear, equivalent linear and nonlinear methods. These methods of ground response analysis may also be categorized into time domain and frequency domain concepts. Simplicity in developing analytical relations and accuracy in considering soils' dynamic properties dependency to loading frequency are benefits of frequency domain analysis. On the other hand, nonlinear methods are complicated and time consuming mainly because of their step by step integrations in time intervals. In part Ι of this paper, governing equations for seismic response analysis of surcharged and layered soils were developed using fundamental of wave propagation theory based on transfer function and boundary conditions. In this part, nonlinear seismic ground response is analyzed using extended HFTD method. The extended HFTD method benefits Newton-Raphson procedure which applies regular iterations and follows soils' fundamental stress-strain curve until convergence is achieved. The nonlinear HFTD approach developed here are applied to some examples presented in this part of the paper. Case studies are carried in which effects of some influencing parameters on the response are investigated. Results show that the current approach is sufficiently accurate, efficient, and fast converging. Discussions on the results obtained are presented throughout this part of the paper.

고진동수 지진동에 대한 원전 기기의 지진취약도 분석 (Seismic Fragility Analysis of NPP Components for High Frequency Ground Motions)

  • 최인길;서정문;전영선
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.110-117
    • /
    • 2003
  • The result of recent seismic hazard analysis indicates that the ground motion response spectra for Korean nuclear power plant site have relatively large high frequency acceleration contents. In the ordinary seismic fragility analysis of nuclear power plant structures and equipments, the safety margin of design ground response spectrum is directly used as a response spectrum shape factor. The effects of input response spectrum shape on the floor response spectrum were investigated by performing the direct generation of floor response spectrum from the ground response spectrum. The safety margin included in the design ground response spectrum should be considered as a floor response spectrum shape factor for the seismic fragility analysis of the equipments located in a building.

  • PDF

Stochastic micro-vibration response characteristics of a sandwich plate with MR visco-elastomer core and mass

  • Ying, Z.G.;Ni, Y.Q.;Duan, Y.F.
    • Smart Structures and Systems
    • /
    • 제16권1호
    • /
    • pp.141-162
    • /
    • 2015
  • The magneto-rheological visco-elastomer (MRVE) is used as a smart core to control the stochastic micro-vibration of a sandwich plate with supported mass. The micro-vibration response of the sandwich plate with MRVE core and supported mass under stochastic support motion excitations is studied and compared to evaluate the vibration suppression capability. The effects of the supported mass and localized magnetic field on the stochastic micro-vibration response of the MRVE sandwich plate are taken into account. The dynamic characteristics of the MRVE core in micro-vibration are described by a non-homogeneous complex modulus dependent on vibration frequency and controllable by applied magnetic fields. The partial differential equations for the coupled transverse and longitudinal motions of the MRVE sandwich plate with supported mass are derived from the dynamic equilibrium, constitutive and geometric relations. The simplified ordinary differential equations are obtained for the transverse vibration of the MRVE sandwich plate under localized magnetic fields. A frequency-domain solution method for the stochastic micro-vibration response of sandwich plates with supported mass is developed based on the Galerkin method and random vibration theory. The expressions of frequency-response functions, response power spectral densities and root-mean-square velocity responses of the plate in terms of the one-third octave frequency band are obtained for micro-vibration evaluation. Finally, numerical results are given to illustrate the large response reduction capacity of the MRVE sandwich plate with supported mass under stochastic support motion excitations, and the influences of MRVE parameters, supported mass and localized magnetic field placement on the micro-vibration response.