• 제목/요약/키워드: a force feedback

검색결과 501건 처리시간 0.032초

전달관로를 고려한 공기압 구동장치의 힘 제어에 관한 연구 (Force Control of a Pneumatic Driving System With a Long Transmission Line)

  • 장지성
    • 유공압시스템학회논문집
    • /
    • 제8권3호
    • /
    • pp.8-13
    • /
    • 2011
  • In the present study, a robust controller has been designed to control force for a pneumatic driving system considering the effect of a transmission line. Transfer characteristics of pneumatic transmission line should be changed according to the velocity of the air going through the transmission line. The designed controller is composed of two parts. The one is a feedback controller, which is composed of a stabilizing filter, a compensating filter of modelling error and a nominal model of the force control system, to compensate the influence of transmission line and improve the feedback characteristics of the control system, and, the other is a feedforward controller to achieve the control performance. Control results with the designed controller show that the robustness and performance of the control system are improved compared to the control results with a fixed gain controller.

원격해체 작업을 위한 유압 시스템의 SPO 기반 반력 추정 및 힘 반향 양방향 원격제어 (SPO based Reaction Force Estimation and Force Reflection Bilateral Control of Cylinder for Tele-Dismantling)

  • 차금강;윤성민;이민철
    • 로봇학회논문지
    • /
    • 제12권1호
    • /
    • pp.1-10
    • /
    • 2017
  • For dismantling heavy structure under special environment in radioactivity, there are many problems which should be tele-operated and feedback a cutting force for cutting a thick structure such as concrete. When operator dismantles a thick heavy concrete structure, it is in sufficient to judge whether robot is contacting or not with environment by using only vision information. To overcome this problem, force feedback and impedance model based bilateral control are introduced. The sliding mode control with sliding perturbation observer (SMCSPO) based bilateral control is applied and surveyed to a single rod hydraulic cylinder in this paper. The sliding mode control is used for robustness against a disturbance. The sliding perturbation observer is used for estimation of a reaction force such as cutting force. The bilateral control is executed using the information of reaction force estimated by SMCSPO. The contribution of this paper is that the estimation method and bilateral control of the single rod hydraulic cylinder are introduced and discussed by experiment.

비구동 매스터 암을 이용한 원격로봇의 매스터-슬래이브 제어 (A master-slave control for telerobot using a non-actuated master arm)

  • 황석용;김승호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1692-1695
    • /
    • 1997
  • In this paper, a new control scheme for master-slave control of telerobot is proposed. The porposed method can be classified into unilater master-slave control methods in the aspect of the data flow. But the master arm in the proposed control scheme can deliver operator the similar kinesthetic sense as other bilateral force reflecting master arms do. The principle concept is that the sensed operator's force/torque is used as the reference input for a damping controller type of telerobot controller which track the operators efforts. Master arm and master controller can be implemented in a simple form, and it needs not be driven by actuators, but force sensing capability.

  • PDF

ER 유체를 이용한 햅틱 마스터와 가상 MIS 환경의 연동제어 (Force-Feedback Control of an Electrorheological Haptic Device in MIS Virtual Environment)

  • 강필순;한영민;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.422-427
    • /
    • 2006
  • This paper presents force-feedback control performance of a haptic device in virtual environment of minimally invasive surgery(MIS). As a first step, based on an electrorheological(ER) fluid and spherical geometry, a new type of master device is developed and integrated with a virtual environment of MIS such as a surgical tool and human organ. The virtual object is then mathematically formulated by adopting the shape retaining chain linked(S-Chain) model. After evaluating reflection force, computational time, and compatibility with real time control, the virtual environment of MIS is formulated by interactivity with the ER haptic device in real space. Tracking control performances for virtual force trajectory are presented in time domain, and theirtrackingerrorsareevaluated.

  • PDF

전기유변 유체를 이용한 햅틱 마스터와 가상의 최소침습수술 환경과의 연동제어 (Force-feedback Control of an Electrorheological Haptic Device in MIS Virtual Environment)

  • 강필순;한영민;최승복
    • 한국소음진동공학회논문집
    • /
    • 제16권12호
    • /
    • pp.1286-1293
    • /
    • 2006
  • This paper presents force-feedback control performance of a haptic device in virtual environment of minimally invasive surgery(MIS). As a first step, based on an electrorheological (ER) fluid and spherical geometry, a new type of master device is developed and integrated with a virtual environment of MIS such as a surgical tool and human organ. The virtual object is then mathematically formulated by adopting the shape retaining chain linked(S-chain) model. After evaluating reflection force, computational time, and compatibility with real time control, the virtual environment of MIS is formulated by interactivity with the ER haptic device in real space. Tracking control performances for virtual force trajectory are presented in time domain.

Effects of auditory feedback and task difficulty on the cognitive load and virtual presence in a virtual reality dental simulation

  • Kim, Byunggee;Yang, Eunbyul;Choi, Namki;Kim, Seonmi;Ryu, Jeeheon
    • 대한치과의사협회지
    • /
    • 제58권11호
    • /
    • pp.670-682
    • /
    • 2020
  • This research examined the difference in cognitive load and the virtual presence depending on auditory feedback and task difficulty in haptic-based dental simulation. In the field of dental education, practice-centered training using handpiece has been crucial because a practitioner's psychomotor experience has a significant impact on the mastery of treatment skills. For the novice, it is necessary to reduce errors in dental treatment to enhancing skill acquisition in the haptic practice. In the training process, the force-feedback is crucial to elaborate subtle movement to guide what to do and how it should be hard or soft. However, It is not easy to add force-feedback to generate kinetic experience training. As an alternative method, we examined that auditory feedback can help learners' skill training. In this study, we analyzed how the presence/absence of auditory feedback at the different levels of task difficulty impacts learners' psychological demand and virtual presence in the virtual reality simulation. For this study, 29 dental college students participated in a dental simulation. The participants were grouped into two conditions that are with and without auditory feedback. Additionally, two consecutive tooth preparation tasks with different levels of difficulty were used in the simulation. The auditory feedback condition gives alarms to a learner when he treats a non-targeted tooth with a virtual handpiece. The user's cognitive load and virtual presence were measured to examine the effects of auditory feedback. The results revealed that the main effect was found in cognitive loads. Also, a significant interaction effect was shown in the virtual presence. We discussed the effective design methods for the virtual reality-based dental simulation through the result of this study.

  • PDF

Optimization and Thrust force Calculation of Linear Generator in Starting Mode for Free-Piston Engine Applications

  • Lee, Hyun-Woo;Eid Ahmad M.;Sugimura Hisayuki;Choi, Kwang-Ju;Nakaoka Mutsuo
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.395-398
    • /
    • 2006
  • this paper provides a novel method to start the linear engine coupled linear generator from dead stop to its final steady state operation. This method depends mainly to use the linear generator mounted on the shaft of the linear engine to provide the required thrust force to move and oscillate the linear engine from bottom to top dead centers. It is a cost effective approach to start the internal linear combustion engine using its coupled tubular permanent magnet linear generator proposed here. This linear generator operates in this case in motoring mode, providing the required thrust force by feeding this linear generator phases with currents by using a three phase PWM inverter controlled by position feedback scheme. In order to provide the desired thrust force with specific value and direction, a position feedback is required to control the free piston engine motion through controlling the inverter switches using PWM control scheme.

  • PDF

Effect of Fatigue on Force-Matching in the Quadriceps Muscle

  • Song, Young-Hee;Lee, Su-Young;Kwon, Oh-Yun
    • 한국전문물리치료학회지
    • /
    • 제13권4호
    • /
    • pp.10-15
    • /
    • 2006
  • This study examined the ability of human subjects to match a force in their quadriceps muscle during fatigue. Twenty subjects (mean age: 23.4 yrs, mean height: 167.8 cm, mean weight, 62.6 kg) were enrolled in the experiment. In the force-matching task, the quadriceps muscle generated 50% of the MVIC (maximum voluntary isometric contraction) torque under visual control and then without visual feedback. After inducing fatigue in the quadriceps muscle, the subjects were required to match 50% of the MVIC torque without visual feedback. The perceived magnitude of the force and force-matching errors were measured. 50% of the MVIC torque was perceived from 39.96 Nm in the pre-fatigue condition to 44.95 Nm in the post-fatigue condition. 50% of the MVIC torque-matching errors increased significantly from .55% in the pre-fatigue condition to 9.6% in the post-fatigue condition (p<.001). in addition, there were significantly more force-matching errors in women than in men (p<.01). In conclusion muscle fatigue can interfere with a subject's ability to match a force. This suggests that muscle fatigue may contributes to the sensitization of the proprioception.

  • PDF

햅틱 피드백 장치를 이용한 치과 수술 시뮬레이션 (Dental Surgery Simulation Using Haptic Feedback Device)

  • 윤상연;성수경;신병석
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제12권6호
    • /
    • pp.275-284
    • /
    • 2023
  • 가상 현실 시뮬레이션은 다양한 분야에서의 교육과 훈련에 활용이 되며, 특히 최근에는 의료 분야에서 많이 사용되고 있다. 교육/훈련용 시뮬레이터는 의사가 실제 수술 도구를 이용하여 실제 환자에 대해 처치를 하는 것과 같은 느낌이 나게 하는 촉감/역감 생성 및 영상/음향 출력 하드웨어와 여기에 실감 나는 영상과 촉감을 생성해주는 소프트웨어로 이루어진다. 기존의 시뮬레이터들은 수술 시에 사용되는 다양한 수술 도구들을 모사하기 위해 다양한 형태의 하드웨어들을 사용해야 하므로 복잡하고 비용이 많이 소요되는 문제가 있다. 이 논문에서는 포스 피드백 장치와 변형 가능한 햅틱 컨트롤러를 이용한 치과 수술 시뮬레이션 시스템을 제안한다. 햅틱 하드웨어들은 수술 도구와 수술 부위의 충돌 여부를 파악하고 그에 따른 저항감과 진동감을 제공한다. 특히 길이 변화, 굽힘과 같은 변형이 가능한 햅틱 컨트롤러는 여러 수술 도구들의 형태에 따라 느껴지는 다양한 감각을 표현할 수 있다. 사용자가 햅틱 피드백 장치를 조작하면 햅틱 피드백 장치의 움직임이나 버튼 클릭 등의 이벤트가 시뮬레이션 시스템에 전달되어 치과용 수술 도구와 구강 내부 모델들 사이의 상호작용이 발생하고 이에 따른 햅틱 피드백이 햅틱 피드백 장치로 전달된다. 이러한 기반 기술들을 활용하여 정교한 3차원 모델로 표현된 가상 환경에서 대표적인 치과 수술기법인 매복 사랑니 발치 수술의 현실적인 훈련 경험을 제공한다.