• Title/Summary/Keyword: a chamber

Search Result 6,513, Processing Time 0.049 seconds

Thermal Dynamics of Core and Periphery Temperature during Treadmill Sub-maximal Exercise and Intermittent Regional Body Cooling (트래드밀에서의 최대하 부하 운동과 간헐적 부위별 인체 냉각 시 심부와 말초 부위의 체온 변화)

  • Lee, Joo-Young;Koscheyev, Victor S.;Kim, Jung-Hyun;Warpeha, Joe M.
    • Journal of Korean Living Environment System
    • /
    • v.16 no.2
    • /
    • pp.89-100
    • /
    • 2009
  • The present study was designed to observe the thermal dynamics of core and skin temperatures during sub-maximal treadmill exercise; to investigate the effect of regional body cooling during short rest after the treadmill exercise on the thermal dynamics. Three conditions (No cooling, Head/Hand cooling, Leg cooling) were simulated in a climatic chamber at 24±1℃ and 50±5%RH. Subjects performed two bouts of treadmill exercise at a rate of 80%HRmax followed by rest. Body cooling with a hood, long gloves, and a blanket that circulated water set at 15℃ was assigned during two bouts of rest. The results showed that (1) rectal temperature (Tre) did not show significant difference between three conditions; (2) Skin temperatures had specific features, depending on body regions. In particular, the initial fall phenomena of skin temperatures at the onset of exercise were noteworthy in the chest, thigh, calf, and finger tip. Of these, the most significant initial fall was found in finger temperature (Tfing). (3) During the period of the initial fall in skin temperatures, Tre gradually increased. (4) The magnitude of the fall of Tfing at the onset of 2nd running was on average 4.8, 5.1 and 3.4℃ for Control, HH cooling, and Leg cooling, respectively (p<0.05). The initial drop of Tfing at the onset of running was maintained for an average of 8.1, 7.9 and 6.3 minutes for Control, HH cooling, and Leg cooling, with no significant differences. In conclusion, the initial fall phenomena at the onset of treadmill exercise reflected non-thermal factors, as opposed to internal thermal status. The magnitude of the initial fall in Tfing was affected by legs cooling. Therefore, the initial fall phenomenon should be considered when interpreting the thermal status of the shell during heavy works/exercises that assigned with intermittent regional body cooling.

Establishment of the Room Acoustic Criteria for the Korean Traditional Music Halls Using Subjective Listening Tests (청감실험에 의한 국악당의 음향설계조건 설정)

  • Haan, Chan-Hoon;Shin, Jic-Su
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.7
    • /
    • pp.343-352
    • /
    • 2007
  • The present study aims to investigate the design standard for acoustic criteria of Korean traditional music which could be used for the design of Korean traditional music halls. In order to do this, subjective listening tests were undertaken to musicians using auralized sounds which were convolved with the impulse response of traditional instruments recorded in an anechoic chamber. 94 pairs of sound were made which have different value of acoustic parameters including RT, BR, Brilliance, G, C80, ITDG, IACC. A paired comparison method(PCM) was used to analyze the results from the subjective listening tests. The results show that the preference of acoustic criteria for the Korean traditional music is far different from those of western music. As a result, specific range of acoustic criteria were suggested for the appropriate acoustic conditions of Korean traditional music. Also, a guideline of the acoustic design of halls for performing the Korean traditional music was suggested which could be used as a basic reference in the future works.

Shielding Design Optimization of the HANARO Cold Neutron Triple-Axis Spectrometer and Radiation Dose Measurement (냉중성자 삼축분광장치의 차폐능 최적화 설계 및 선량 측정)

  • Ryu, Ji Myung;Hong, Kwang Pyo;Park, J.M. Sungil;Choi, Young Hyeon;Lee, Kye Hong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.21-29
    • /
    • 2014
  • A new cold neutron triple-axis spectrometer (Cold-TAS) was recently constructed at the 30 MWth research reactor, HANARO. The spectrometer, which is composed of neutron optical components and radiation shield, required a redesign of the segmented monochromator shield due to the lack of adequate support of its weight. To shed some weight, lowering the height of the segmented shield was suggested while adding more radiation shield to the top cover of the monochromator chamber. To investigate the radiological effect of such change, we performed MCNPX simulations of a few different configurations of the Cold-TAS monochromator shield and obtained neutron and photon intensities at 5 reference points just outside the shield. Reducing the 35% of the height of the segmented shield and locating lead 10 cm from the bottom of the top cover made of polyethylene was shown to perform just as well as the original configuration as radiation shield excepting gamma flux at two points. Using gamma map by MCNPX, it was checked that is distribution of gamma. Increased flux had direction to the top and it had longer distance from top of segmented shield. However, because of reducing the 35% of the height, height of dissipated gamma was lower than original geometry. Reducing the 35% of the height of the segmented shield and locating lead 10cm from the bottom of the top cover was selected. After changing geometry, radiation dose was measured by TLD for confirming tester's safety at any condition. Neutron(0.21 ${\mu}Svhr^{-1}$) and gamma(3.69 ${\mu}Svhr^{-1}$) radiation dose were satisfied standard(6.25 ${\mu}Svhr^{-1}$).

Resistance Functions of Woody Landscape Plants to Air Pollutants (I) - SOD Activity - (조경수목(造景樹木)의 대기오염물질(大氣汚染物質)에 대한 방어기능(防禦機能) (I) - SOD 활성(活性)을 중심으로 -)

  • Kim, Myung Hee;Lee, Soo Wook
    • Journal of Korean Society of Forest Science
    • /
    • v.81 no.2
    • /
    • pp.164-176
    • /
    • 1992
  • This study was conducted to determine the toxic effects of air pollutants on landscaping trees, Pinus densiflora, Pinus koraierasis, Ginkgo biloba, Liriodeytdron tulipifera, Platanus occidentalis and their resistance to the pollutant toxicity in urban and industrial regions of Seoul and Taejon, Korea. Total sulfur content and superoxide dismutase activity were analysed in tree foliage of Pinus densiflora, Pinzes koraiensis, Ginkgo biloba, Liriodendron tulipifera, Platanus occidentalis. In addition, SOD activity was analyzed in the foliage of tree seedlings, i.e. Pinus densijlora, Pinus koraiensis, Ginkgo biloba, Liriodendron tulipifera, with the lurnigation of $SO_2$ in gas chamber 4 hours a day for six days. In all species total sulfur content and SOD activity had a positive correlation. Air pollutants accumulated in tree tissues were supposed to enhance the enzyme activity like SOD providing with the resistance mechanisms. Trees under the air pollution stress increased enzyme activity to develop internal self-resistance against pollutants, but after a critical point enzyme-activity decreased gradually and resulting in injury after all, Deciduous trees had greater filtration capacity than conifers and coniferous trees showed greater resistance against air pollutants than deciduous species. Foliage SOD activity was higher in polluted area than in unpolluted area for most species. Coniferous species and mature trees had higher SOD activity than deciduous seedlings. Especially Pinus koraiensis, Ginkgo biloba and Plcatanus occidentalis had higher SOD activity than other species. The tree species with the high SOD activity showed strong resistance against air pollutants. In 2nd-year needles of Pinus densiflora seedlings and current and 2nd-year needles of Pinus koraiensis seedlings containing high native SOD activity, SOD activity increased with the increase of $SO_2$ level. But in seedlings containing low native SOD activity, SOD activity increased at 0.5ppm $SO_2$ level while it decreased at 1.5 and 2.5ppm $SO_2$. Changes of SOD activity was different between species and in most species SOD seemed to participate in resistance mechanism.

  • PDF

Dosimetric Characteristics of Edge $Detector^{TM}$ in Small Beam Dosimetry (소조사면 선량 계측을 위한 엣지검출기의 특성 분석)

  • Chang, Kyung-Hwan;Lee, Bo-Ram;Kim, You-Hyun;Choi, Kyoung-Sik;Lee, Jung-Seok;Park, Byung-Moon;Bae, Yong-Ki;Hong, Se-Mie;Lee, Jeong-Woo
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.191-198
    • /
    • 2009
  • In this study, we evaluated an edge detector for small-beam dosimetry. We measured the dose linearity, dose rate dependence, output factor, beam profiles, and percentage depth dose using an edge detector (Model 1118 Edge) for 6-MV photon beams at different field sizes and depths. The obtained values were compared with those obtained using a standard volume ionization chamber (CC13) and photon diode detector (PFD). The dose linearity results for the three detectors showed good agreement within 1%. The edge detector had the best linearity of ${\pm}0.08%$. The edge detector and PFD showed little dose rate dependency throughout the range of 100~600 MU/min, while CC13 showed a significant discrepancy of approximately -5% at 100 MU/min. The output factors of the three detectors showed good agreement within 1% for the tested field sizes. However, the output factor of CC13 compared to the other two detectors had a maximum difference of 21% for small field sizes (${\sim}4{\times}4\;cm^2$). When analyzing the 20~80% penumbra, the penumbra measured using CC13 was approximately two times wider than that using the edge detector for all field sizes. The width measured using PFD was approximately 30% wider for all field sizes. Compared to the edge detector, the 10~90% penumbras measured using the CC13 and PFD were approximately 55% and 19% wider, respectively. The full width at half maximum (FWHM) of the edge detector was close to the real field size, while the other two detectors measured values that were 8~10% greater for all field sizes. Percentage depth doses measured by the three detectors corresponded to each other for small beams. Based on the results, we consider the edge detector as an appropriate small-beam detector, while CC13 and PFD can lead to some errors when used for small beam fields under $4{\times}4\;cm^2$.

  • PDF

New Estimates of CH4 Emission Scaling Factors by Amount of Rice Straw Applied from Korea Paddy Fields (볏짚 시용에 따른 벼 재배 논에서의 메탄 배출계수 개발에 관한 연구)

  • Ju, Okjung;Won, Tae-Jin;Cho, Kwang-Rae;Choi, Byoung-Rourl;Seo, Jae-Sun;Park, In-Tae;Kim, Gun-Yeob
    • Korean Journal of Environmental Agriculture
    • /
    • v.32 no.3
    • /
    • pp.179-184
    • /
    • 2013
  • BACKGROUND: Accurate estimates of total direct $CH_4$ emissions from croplands on a country scale are important for global budgets of anthropogenic sources of $CH_4$ emissions and for the development of effective mitigation strategies. Methane production resulted by the anaerobic decomposition of organic compounds where $CO_2$ acts as inorganic electron acceptor. This process could be affected by the addition of rice straw, water management and rice variety itself. METHODS AND RESULTS: Rice (Oryza sativa L. Japonica type, var Samkwangbyeo) was cultivated in four plots: (1) Nitrogen-Phosphorus-Potassium (NPK) ($N-P_2O_5-K_2O$:90-45-57 kg/ha); (2) NPK plus 3 Mg/ha rice straw (RS3); (3) NPK plus 5 Mg/ha rice straw (RS5); (4) NPK plus 7 Mg/ha rice straw (RS7) for 3 years (2010-2012) and the rice straw incorporated in fall (Nov.) in Gyeonggi-do Hwaseong-si. Gas samples were collected using the closed static chamber which were installed in each treated plot of $152.9m^2$. According to application of 3, 5, 7 Mg/ha of rice straw, methane emission increased by 46, 101, 190%, respectively, compared to that of the NPK plot. CONCLUSION(S): We obtained a quantitative relationship between $CH_4$ emission and the amount of rice straw applied from rice fields which could be described by polynomial regression of order 2. The emission scaling factor estimated by the relationship were in the range of IPCC GPG (2000).

Study of Synthesis and Biological Function on Aminophosphonic Acids (Aminophosphonic Acids 화합물의 생물학적 기능연구)

  • Kim, Sook-He
    • Journal of Nutrition and Health
    • /
    • v.4 no.4
    • /
    • pp.39-46
    • /
    • 1971
  • Since ${\beta}-aminoethylphosphonic$ acid was discovered in the living organism, the biosynthesis and biological function of aminophosphonic acids have been extensively studied. The purpose of this project consists in the two parts: 1)the preparation of DL-1-amino-2-phenylethylphosphonic acid (Phenylalanine aminophosphonic acid) and DL-1-amino-3-methylbutyl-phosphonic acid (Isoleucine aminophosphonic acid) by the method of Chamber and Isbell. 2) the study of metabolism and biological functions of those synthetic materials by the animal experiment (white rats) The importance of this project proved to be the first experience fed by animals for the elucidation of biochemical and metabolic functions in the animal body. The following organic synthesis of DL-1-amino-3-methylbutylphosphonic acid and DL-1-amino-2-phenylethylphosphonic acid are studied. 1)Synthesis of DL-1-amino-3-methylbutylphosphonic acid a) Synthesis of Iso-butylbromide b) Synthesis of Ethyl iso-butylmalonate c) Synthesis of Iso-caproic acid d) Synthesis of $Ethyl-{\alpha}-bromo$ iso-caproate e) Synthesis of $Triethyl-{\alpha}-phosphono$ iso-caproate f) Synthesis of DL-1-amino-3-methylbutylphosphonic acid 2)Synthesis of DL-1-amino-2-phenylethylphosphonic acid a) Synthesis of Diethyl phosphite b) Synthesis of Ethylchloro acetate c) Synthesis of Triethyl phospho acetate d) Synthesis of Triethyl benzyl phospho acetate e) Synthesis of DL-1-amino-2-phenylethylphosphonic acid The synthetic compounds; DL-1-amino-3-methylbutylphosphonic acid and DL-1-amino-2-phenyl ethylphosphonic acid which are essential amino acid (isoleucine, phenylalanine)analogue are supplemented to the animal diet at the level of 0.2% and 0.4% for isoleucine analogue and 0.35% and 0.7% for phenylalanine analogue. The plain isoleucine and phenylalanine at the same level in the diet are fercilitated as comparable groups in this study. Two sets of experience including 100 male rats were carried out for seven weeks each total 14 weeks. During this period, urine samples, and each big organs were collected for the analysis of total nitrogen, phosphorus, and glycogen contents in the individual samples by Micro Kjeldahl Fisk & Subbarow and Nelson Somogye, method. 1) The result of the project a) The yield of DL-1-amino-3-methylbutylphosphonic acid and DL-1-amino-2-phenylethylphosphonic acid showed low tendency at the level of 12.5% and 20% Melting point of those two compounds were very high and the ${\alpha}-amino$ group in the synthetic compounds showed positive reaction with ninhydrin in the violet color. b) Ail the experimental groups included in this study revealed statistically no significant difference in the organ weight, total body nitrogen retention and urinary phosphorus excretion This means isoleucine aminophosphonic acid and Phenylalanine aminophosphonic acid were utilized in the body as much as the plain amino acids, isoleucine and phenylalanine did. c) The glycogen contents in the liver of the phenylalaine aminophosphonic acid gruop showed higher statistically significant(p<0.05) in the comparision with the group of the Phenylalanine and the Standard-2. It was noteworthy that the higher glycogen content in the liver might indicate the significance in the incorporation of phenylalanine aminophosphonic acid into the intermediate of tricarboxylic acid cycle as activated state.

  • PDF

Development of Preliminary Quality Assurance Software for $GafChromic^{(R)}$ EBT2 Film Dosimetry ($GafChromic^{(R)}$ EBT2 Film Dosimetry를 위한 품질 관리용 초기 프로그램 개발)

  • Park, Ji-Yeon;Lee, Jeong-Woo;Choi, Kyoung-Sik;Hong, Semie;Park, Byung-Moon;Bae, Yong-Ki;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.113-119
    • /
    • 2010
  • Software for GafChromic EBT2 film dosimetry was developed in this study. The software provides film calibration functions based on color channels, which are categorized depending on the colors red, green, blue, and gray. Evaluations of the correction effects for light scattering of a flat-bed scanner and thickness differences of the active layer are available. Dosimetric results from EBT2 films can be compared with those from the treatment planning system ECLIPSE or the two-dimensional ionization chamber array MatriXX. Dose verification using EBT2 films is implemented by carrying out the following procedures: file import, noise filtering, background correction and active layer correction, dose calculation, and evaluation. The relative and absolute background corrections are selectively applied. The calibration results and fitting equation for the sensitometric curve are exported to files. After two different types of dose matrixes are aligned through the interpolation of spatial pixel spacing, interactive translation, and rotation, profiles and isodose curves are compared. In addition, the gamma index and gamma histogram are analyzed according to the determined criteria of distance-to-agreement and dose difference. The performance evaluations were achieved by dose verification in the $60^{\circ}$-enhanced dynamic wedged field and intensity-modulated (IM) beams for prostate cancer. All pass ratios for the two types of tests showed more than 99% in the evaluation, and a gamma histogram with 3 mm and 3% criteria was used. The software was developed for use in routine periodic quality assurance and complex IM beam verification. It can also be used as a dedicated radiochromic film software tool for analyzing dose distribution.

IMRT and IMRS Checking the Dose Distribution in the Small Field Evaluation of Measurement by Changes in SAD (IMRT 및 IMRS에서 Small Field의 선량분포 확인시 SAD 변화에 따른 측정의 유용성 평가)

  • Ko, Seung-Young;Kim, Sung-Joon;Park, Gir-Yong;Son, Mi-Suk;Lee, Nam-Ki;Kim, Jin-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.33-39
    • /
    • 2010
  • Purpose: It is very important to confirm conformance of dose distribution that is formed with treatment planning from IMRS or IMRT. It has been a problem dropped accuracy and conformance when the field size is getting smaller because of character of the 2D ion chamber. Verification of MatriXX Phantom dose distribution with a change in the SAD. Dose distribution measurement and analysis to improve the accuracy and should be useful to evaluate the award. Materials and Methods: A use of Novalis linear accelerator 6 MV photon beams. In general, IMRS were 25 patients with small field size. The selected patients were divided into three groups on the basis of the field size. SAD was changed from 80 to 130 cm and field size to determine the dose distribution to the change, each dose was measured using MatriXX Phantom. Analysis of measured values obtained from the program for each patient through the treatment planning system comparison and analysis of the dose distribution and gamma values were expressed. Result: SAD 80, 100, and 120 cm in size in the gamma value to the investigation of patients less than $3\;cm^2$ average 0.939, 0.969, and 0.979, respectively. Patients with more than $5\;cm^2$ 0.962, 0.983, and 0.988, respectively. $5\;cm^2$ or more patients 0.982, 0.990, and 0.992, respectively. Conclusion: The error rate of less than $3\;cm^2$ field size is increased rapidly. If the field size is increased, resolution is increased by 2D ion chambers. It has been approved that it can be credible if it is around $3\;cm^2$ when measuring dose distribution using MatriXX. Adjusting geometric field size by changing SAD is likely to be very useful when you measure dose distribution using MatriXX.

  • PDF

Optical Property of Super-RENS Optical Recording Ge2Sb2Te5 Thin Films at High Temperature (초해상 광기록 Ge2Sb2Te5 박막의 고온광물성 연구)

  • Li, Xue-Zhe;Choi, Joong-Kyu;Lee, Jae-Heun;Byun, Young-Sup;Ryu, Jang-Wi;Kim, Sang-Youl;Kim, Soo-Kyung
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.5
    • /
    • pp.351-361
    • /
    • 2007
  • The samples composed of a GST thin film and the protective layers of $ZnS-SiO_2$ or $Al_2O_3$ coated on c-Si substrate were prepared by using the magnetron sputtering method. Samples of three different structures were prepared, that is, i) the GST single film on c-Si substrate, ii) the GST film sandwiched by the protective $ZnS-SiO_2$ layers on c-Si substrate, and iii) the GST film sandwiched by $Al_2O_3$ protective layers on c-Si substrate. The ellipsometric constants in the temperature range from room temperature to $700^{\circ}C$ were obtained by using the in-situ ellipsometer equipped with a conventional heating chamber. The measured ellipsometric constants show strong variations versus temperature. The variation of ellipsometric constants at the temperature region higher than $300^{\circ}C$ shows different behaviors as the ambient medium is changed from in air to in vacuum or the protective layers are changed from $ZnS-SiO_2$ to $Al_2O_3$. Since the long heating time of 1-2 hours is believed to be the origin of the high temperature variation of ellipsometric constants upon the heating environment and the protective layers, a PRAM (Phase-Change Random Access Memory) recorder is introduced to reduce the heating time drastically. By using the PRAM recorder, the GST samples are heated up to $700^{\circ}C$ decomposed preventing its partial evaporation or chemical reactions with adjacent protective layers. The surface image obtained by SEM and the surface micro-roughness verified by AFM also confirmed that samples prepared by the PRAM recorder have smoother surface than the samples prepared by using the conventional heater.