• Title/Summary/Keyword: a chamber

Search Result 6,497, Processing Time 0.038 seconds

A Study on the correlation between underground structure and tumulus of the Royal Tomb in the Joseon Dynasty (조선후기 회격릉의 지하구조를 반영한 봉릉의 시공과 형식)

  • Shin, Ji-Hye
    • Journal of architectural history
    • /
    • v.29 no.2
    • /
    • pp.19-30
    • /
    • 2020
  • In the early of Joseon Dynasty, Royal Tomb developed from stone chamber tomb to lime chamber tomb through precedents. The lime chamber tomb consists of main-chamber(JeongGwang) and sub-chamber(ToeGwang). This separation makes character to construct tumulus of the Royal Tomb half and half. By this character, the Royal Tomb are not constructed by separate structure but constructed by coadjustment. The underground structure and tumulus of the Royal Tomb affect each other in the size and method of construction. The selecting type of Royal Tomb is generally made decision through terrain and politics. This study prove the architectural structure is also one of the major cause the that select type of Royal Tomb.

A Study on the Operational Status of the Chamber for Testing the Thermal Performance of Curtain Walls

  • No, Sang Tae
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.2
    • /
    • pp.147-154
    • /
    • 2014
  • The purposes of this study were to analyze criteria for measurement chamber design dedicated curtain wall, and how to measure of performance configuration and status of the chamber that is currently being used. Main dealing criteria is AAMA 1503-09. Measurement of data is made in curtain wall Mock-up experiment station with thermal imaging camera. Measurement data using thermal imaging cameras at Mock-up curtain was made at the test site. The results of this study were as follows; There is no U-value test method for actual size of curtain wall. The thermal test outdoor chamber showed heat loss in the connection part of indoor and outdoor chamber. And the indoor chamber showed unstable temperature distribution by height.

Design of a Large Magnetron Sputtering System for TFT LCD and Investigation of Sputtered AI Film Properties (TFT LCD 제조용 대면적 Magnetron Sputtering 장치 설계와 Al 성장막 특성 조사)

  • 유운종
    • Journal of the Korean Vacuum Society
    • /
    • v.2 no.4
    • /
    • pp.480-485
    • /
    • 1993
  • Factros considered building the magnetron sputtering system for TFT LCD (thin film transistor liquid crystal display0 metallization were thin film thichnes uniformity, temperature uniformity and the pressure gradient of sputtering gas flow in vacuum chamber, base pressure, and the stability fo the carrier moving . The system was consisted of a deposition chamber, a pre-heating chamber, a RF-precleaning chamber and a load/unload lock chamber. The system was designed to handle a substrate with dimension of 400$\times$400mm. The temperautre uniformity of a heater table developed showed $250 ^{\circ}C\pm$5% accuracyon the substrate glass. A base pressure of 1.8 $\times$10-7 torr was obtained after 24 hours pumping with a cryo pump. After an aluminum target was installed in a sputtering source and the film wa sdeposited on the glass, the uniformity, reflectivity and sheet resistance of the deposited film were measured.

  • PDF

Measurement Technology of Chamber Impedance for RF Matching (RF 정합 특성 개선을 위한 챔버의 임피던스 측정법)

  • 설용태;이의용;박성진
    • Journal of the Semiconductor & Display Technology
    • /
    • v.2 no.4
    • /
    • pp.13-17
    • /
    • 2003
  • An adaptor is designed for chamber impedance measurement of plasma process. Copper rod, fixed board and compensation circuit are the major components of the adaptor. An adaptor can be to measure chamber impedance on time unless stopping a process and Data to measure can do the database. We can use it to a criteria data for a failure diagnosis. So developed adaptor could be used for diagnosis the plasma process chamber in semiconductor industry.

  • PDF

Design and Fabrication of Thrust Chamber for Injector verification of 7 tonf-class Thrust Chamber (7톤급 연소기용 분사기 검증을 위한 연소기 설계 및 제작)

  • Kim, Jong-Gyu;Ahn, Kyu-Bok;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.457-460
    • /
    • 2012
  • Design and fabrication of a sub-scale thrust chamber for verification of 7 tonf-class thrust chamber injectors were described in this paper. The 7 tonf-class thrust chamber consists of mixing head with 90 coaxial swirl injectors and regeneratively combustion chamber cooled by kerosene. The coaxial swirl injectors with different pressure drop and recess number were designed for 7 tonf full-scale thrust chamber. By applying the designed injectors to the sub-scale thrust chamber before applying them to the full-scale thrust chamber, the injector performance and functioning were verified. The sub-scale thrust chamber consists of 19 injectors, has chamber pressure of 70 bar, total propellant mass flow rate of 4.3 kg/s, mixture ratio(O/F) of 2.45.

  • PDF

Design of a Small Radio Frequency Identification Tag Antenna Using a Corrugated Meander Line Applicable to a Drug Runout Sensor System

  • Ko, Dong-Ok;Woo, Jong-Myung
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.1
    • /
    • pp.7-12
    • /
    • 2018
  • This article proposes an ultrahigh frequency band radio frequency identification (RFID) tag antenna for drug runout management that can be used in hospitals. The RFID tag antenna is designed to function as a sensor that alerts drug runout when a drug inside a drip chamber is completely consumed but does not work when a drug remains inside a drop chamber. A previously proposed 915 MHz dipole antenna, is too large to be attached to the drip chamber of a feeding bag. Moreover, the length of the dipole (L) should be increased for conjugate matching with an RFID chip. Therefore, the dipole antenna is downsized so that it can be attached to the drip chamber through a fine meander line structure coupling with a corrugate meander line. A transparent cover is added to enhance the grip force between the designed antenna and the drip chamber and to enable detachment. The dimensions of the completed antenna structure attachable to a drip chamber are 32.59 mm (height) and 13.5 mm (width). The gain reduction due to the decreased antenna length is enhanced. The fabricated antenna shows an average omni-directional read range of 10.65 m on a horizontal plane and has the function of sensing the presence of a drug.

A Validation Model for the Statistical Power Balance Method Using a Reverberation Chamber

  • Lee, Young Seung;Choi, Sung Woong;Park, Seung Keun
    • Journal of electromagnetic engineering and science
    • /
    • v.13 no.3
    • /
    • pp.192-194
    • /
    • 2013
  • This paper proposes a validation model using a reverberation chamber for verification of the effectiveness and accuracy of the statistical power balance (PWB) method. The PWB method treats electromagnetic (EM) field distributions in certain environments as a representative value of an "ensemble" average, so a reverberation chamber is utilized as a testing apparatus to experimentally simulate the sets of measurement field "ensemble" inside a complex environment. Measurements are performed with various test conditions for environmental loss using flat absorbers, and front and side doors of the chamber. Comparison between the PWB analysis and the measurement results shows good agreement, indicating the usefulness of this statistical analysis method for stating the electromagnetic field inside the EM zone as a representative value to general structures.

Prevention of P-i Interface Contamination Using In-situ Plasma Process in Single-chamber VHF-PECVD Process for a-Si:H Solar Cells

  • Han, Seung-Hee;Jeon, Jun-Hong;Choi, Jin-Young;Park, Won-Woong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.204-205
    • /
    • 2011
  • In thin film silicon solar cells, p-i-n structure is adopted instead of p/n junction structure as in wafer-based Si solar cells. PECVD is a most widely used thin film deposition process for a-Si:H or ${\mu}c$-Si:H solar cells. For best performance of thin film silicon solar cell, the dopant profiles at p/i and i/n interfaces need to be as sharp as possible. The sharpness of dopant profiles can easily achieved when using multi-chamber PECVD equipment, in which each layer is deposited in separate chamber. However, in a single-chamber PECVD system, doped and intrinsic layers are deposited in one plasma chamber, which inevitably impedes sharp dopant profiles at the interfaces due to the contamination from previous deposition process. The cross-contamination between layers is a serious drawback of a single-chamber PECVD system in spite of the advantage of lower initial investment cost for the equipment. In order to resolve the cross-contamination problem in single-chamber PECVD systems, flushing method of the chamber with NH3 gas or water vapor after doped layer deposition process has been used. In this study, a new plasma process to solve the cross-contamination problem in a single-chamber PECVD system was suggested. A single-chamber VHF-PECVD system was used for superstrate type p-i-n a-Si:H solar cell manufacturing on Asahi-type U FTO glass. A 80 MHz and 20 watts of pulsed RF power was applied to the parallel plate RF cathode at the frequency of 10 kHz and 80% duty ratio. A mixture gas of Ar, H2 and SiH4 was used for i-layer deposition and the deposition pressure was 0.4 Torr. For p and n layer deposition, B2H6 and PH3 was used as doping gas, respectively. The deposition temperature was $250^{\circ}C$ and the total p-i-n layer thickness was about $3500{\AA}$. In order to remove the deposited B inside of the vacuum chamber during p-layer deposition, a high pulsed RF power of about 80 W was applied right after p-layer deposition without SiH4 gas, which is followed by i-layer and n-layer deposition. Finally, Ag was deposited as top electrode. The best initial solar cell efficiency of 9.5 % for test cell area of 0.2 $cm^2$ could be achieved by applying the in-situ plasma cleaning method. The dependence on RF power and treatment time was investigated along with the SIMS analysis of the p-i interface for boron profiles.

  • PDF

A Study on Chamber Design for the Efficient Preservation of a Small Amount of Archives (소량 기록물의 효율적 보존을 위한 보존챔버 설계에 관한 연구)

  • Bong, Choon-Keun;Park, Seong-Jin;Lee, Jeong-Joo;Shin, Hyun-Chang
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.13 no.1
    • /
    • pp.35-58
    • /
    • 2013
  • The archives preservation chamber is an equipment that is able to store important archives with air-cleaning and isothermal-isohumidity control functions to permanently store archives in a highly safe environment. The chamber can only store small amounts of archives but it is crucial for organizations preserving archives to economically store a variety of archives, be it a medium or a small amount of documents. An arm of this study researches the current preservation status of the local record center to determine the need for such a chamber. In addition, in order to improve the air-cleaning and isothermal-isohumidity functions, the researchers of this study have conducted analyses to design the core parts. The preservation chamber that had been designed includes an archives preservation area, air-cleaning equipment, and environment measurement equipment. A preservation chamber is used to preserve small amounts of important archives safely. Thus, when a local record center is preserving various types of archives in small or medium quantities in a stack room, the preservation chamber can be used to aid their long-term preservation.

COMPARISON OF THE COMBUSTION CHARACTERISTICS BETWEEN S.I. ENGINE AND R.I. ENGINE

  • Chung, S.S.;Ha, J.Y.;Park, J.S.;Kim, K.J.;Yeom, J.K.
    • International Journal of Automotive Technology
    • /
    • v.8 no.1
    • /
    • pp.19-25
    • /
    • 2007
  • This experimental study was carried out to obtain both low emissions and high thermal efficiency by rapid bulk combustion. Two kinds of experiments were conducted to obtain fundamental data on the operation of a RI engine by a radical ignition method. First, the basic experiments were conducted to confirm rapid bulk combustion by using a radical ignition method in a constant volume chamber (CVC). In this experiment, the combustion velocity was much higher than that of a conventional method. Next, to investigate the desirable condition of engine operation using radical ignition, an applied experiment was conducted in an actual engine based on the basic experiment results obtained from CVC condition. A sub-chamber-type diesel engine was reconstructed using a SPI type engine with controlled injection duration and spark timing, and finally, converted to a RI engine. In this study, the operation characteristics of the RI engine were examined according to the sub-chamber's specifications such as the sub-chamber volume and the diameter and number of passage holes. These experimental results showed that the RI engine operated successfully and was affected by the ratio of the passage hole area to the sub-chamber volume.