• 제목/요약/키워드: a attached mass

검색결과 359건 처리시간 0.029초

주요 신경과의 연결이 없이 발생한 긴손바닥근의 신경초종 (Neurilemoma Localized in the Palmaris Longus Tendon with no Connection to the Major Nerve Trunk)

  • 박정용;정성노;손원일;권호
    • Archives of Plastic Surgery
    • /
    • 제38권4호
    • /
    • pp.498-500
    • /
    • 2011
  • Purpose: Neurilemoma is benign tumor of the nerve sheath which arises from Schwann cells. It is usually formed along the path of a peripheral nerve but is rarely separate from normal nerve fascicles. We experienced a patient with an isolated neurilemoma localized in the palmaris longus tendon with no connection to the major nerve trunk, which was in an unusual location and has never been reported. We report our case with the review of the literature. Methods: A 23-year-old female visited our clinic with mild pain on the mass at the flexor area of the right wrist which had been present for about one year. The physical examination revealed a $1{\times}1cm$ sized subcutaneous mass at the flexor area of the right wrist. Sonography and computed tomography showed an ovoid, superficial solid mass on the palmaris longus tendon. Upon surgical excision, a $1{\times}0.5cm$ sized mass attached to the palmaris longus tendon was found. The tumor had no connection with the median nerve and was detached easily from the palmaris longus tendon. Results: Histological examination demonstrated the mass to be a neurilemoma, which consists of spindle shaped cells with oval elongated nuclei arranged fascicles. No sensory dysfunction or evidence of recurrence was found during the 12 months of postoperative follow-up. Conclusion: We experienced a rare case of neurilemoma attached to the palmaris longus tendon with no connection to the major nerve trunk. We wish to emphasize its unusual location through our case and hope to expand our spectrum in exploring the upper extremity mass.

Higher Biomass Productivity of Microalgae in an Attached Growth System, Using Wastewater

  • Lee, Seung-Hoon;Oh, Hee-Mock;Jo, Beom-Ho;Lee, Sang-A;Shin, Sang-Yoon;Kim, Hee-Sik;Lee, Sang-Hyup;Ahn, Chi-Yong
    • Journal of Microbiology and Biotechnology
    • /
    • 제24권11호
    • /
    • pp.1566-1573
    • /
    • 2014
  • Although most algae cultivation systems are operated in suspended culture, an attached growth system can offer several advantages over suspended systems. Algal cultivation becomes light-limited as the microalgal concentration increases in the suspended system; on the other hand, sunlight penetrates deeper and stronger in attached systems owing to the more transparent water. Such higher availability of sunlight makes it possible to operate a raceway pond deeper than usual, resulting in a higher areal productivity. The attached system achieved 2.8-times higher biomass productivity and total lipid productivity of $9.1g\;m^{-2}day^{-1}$ and $1.9g\;m^{-2}day^{-1}$, respectively, than the suspended system. Biomass productivity can be further increased by optimization of the culture conditions. Moreover, algal biomass harvesting and dewatering were made simpler and cheaper in attached systems, because mesh-type substrates with attached microalgae were easily removed from the culture and the remaining treated wastewater could be discharged directly. When the algal biomass was dewatered using natural sunlight, the palmitic acid (C16:0) content increased by 16% compared with the freeze-drying method. There was no great difference in other fatty acid composition. Therefore, the attached system for algal cultivation is a promising cultivation system for mass biodiesel production.

첨가질량이 존재하는 변단면 4변고정 적층복합판의 진동해석 (Vibration Analysis of Clamped Composite Plates with Non-Uniform Cross-Section and with Attached Point Mass/Masses)

  • 박제선;김경진;원치문;심도식
    • 산업기술연구
    • /
    • 제15권
    • /
    • pp.71-75
    • /
    • 1995
  • A method of calculating the natural frequency corresponding to the first mode of vibration of beams and tower structures, with irregular cross-sections and with arbitrary boundary conditions was developed and reported by D. H. Kim in 1974. This method has been developed for two-dimensional problems including the laminated composite plates and was proved to be very effective for the plates with arbitrary boundary conditions and irregular sections. In this paper, the result of application of this method to the clamped composite plates with non-uniform cross-section and with attached point mass/masses is presented.

  • PDF

이동질량과 등분포종동력이 외팔보의 동특성에 미치는 영향 (Influence of Moving Mass on Dynamic Behavior of a Cantilever Pipe Subjected to Uniformly Distributed Follower Forces)

  • Son, In-soo;Yoon, Han-Ik;Kim, Hyeon-Soo
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.315.2-315
    • /
    • 2002
  • The vibrational system of this study consists of a cantilever pipe conveying fluid, the moving mass upon it and an attached tip mass. The equation of motion is derived by using Lagrange equation. The influences of the velocity of moving mass and the uniformly distributed tangential follower force have been studied on the dynamic behavior of a cantilever pipe by numerical method. While the moving mass moves upon the cantilever pipe, the velocity of fluid flow increase, the tip displacement of cantilever pipe conveying fluid is decreased. (omitted)

  • PDF

Free vibration analysis of a uniform beam carrying multiple spring-mass systems with masses of the springs considered

  • Wu, Jia-Jang
    • Structural Engineering and Mechanics
    • /
    • 제28권6호
    • /
    • pp.659-676
    • /
    • 2008
  • The reports regarding the free vibration analysis of uniform beams carrying single or multiple spring-mass systems are plenty, however, among which, those with inertia effect of the helical spring(s) considered are limited. In this paper, by taking the mass of the helical spring into consideration, the stiffness and mass matrices of a spring-mass system and an equivalent mass that may be used to replace the effect of a spring-mass system are derived. By means of the last element stiffness and mass matrices, the natural frequencies and mode shapes for a uniform cantilever beam carrying any number of springmass systems (or loaded beam) are determined using the conventional finite element method (FEM). Similarly, by means of the last equivalent mass, the natural frequencies and mode shapes of the same loaded beam are also determined using the presented equivalent mass method (EMM), where the cantilever beam elastically mounted by a number of lumped masses is replaced by the same beam rigidly attached by the same number of equivalent masses. Good agreement between the numerical results of FEM and those of EMM and/or those of the existing literature confirms the reliability of the presented approaches.

가속도계 영향을 제거한 소형 구조물의 동특성 모델 개선 (Model Updating in Small Structural Dynamics Model by Elimination of Mass Loading Effect of Accelerometer)

  • 이정윤
    • 한국소음진동공학회논문집
    • /
    • 제25권1호
    • /
    • pp.40-47
    • /
    • 2015
  • Dynamic response of any small structure is always affected by the mass of the attached accelerometer. This paper predicts the natural frequencies and frequency response functions by removing the mass loading effect from the accelerometer. This mass loading is studied on a simple cantilever beams by varying the location of accelerometer. By using sensitivity analysis with iteration method, accelerometer mass and location are obtained. The predicted natural frequencies of the small cantilever beam without the accelerometer's mass show good agreement with the structural re-analysis.

Intra-Suprasellar Schwannoma Originating from the Diaphragma Sellae

  • Park, Hyun-Woong;Jung, Shin;Jung, Tae-Young;Moon, Kyung-Sub
    • Journal of Korean Neurosurgical Society
    • /
    • 제45권6호
    • /
    • pp.375-377
    • /
    • 2009
  • A 49-year-old woman presented with headache, vomiting and visual disturbance. Neurological examination revealed bitemporal hemianopsia with poor visual acuity. Magnetic resonance imaging showed a bulky intra-suprasellar mass, which was isointense with brain parenchyma on T1-weighted images, and slightly hyperintense on T2-weighted images. After gadolinium administration, the mass was homogeneously enhanced. The mass was partially removed by the endonasal transsphenoidal approach and then the remnant mass was totally removed by the transcranial approach five months later. We found a yellowish mass which was attached to the diaphragm sellae in operation field. Histopathological examination of the tumor revealed the characteristic features of a schwannoma. We report an unusual case of an intra-suprasellar schwannoma resembling a non-functioning pituitary macroadenoma both clinically and radiologically.

차륜 진동을 고려한 능동 현가계 제어 (Control of Active Suspension System Considering Wheel-Hop)

  • 이동락;한기봉;이시복
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1994년도 추계학술대회 논문집
    • /
    • pp.420-424
    • /
    • 1994
  • In this paper, an active suspension system considering the wheel hop is studied for a quarter car model. A LQ controller controls an active suspension system in which a vibration absorber is attached to the wheel axis. The vibration absorber is adopted to reduce the vibration near the natural frequency of the unsprung mass, and the LQ controller is used to control the vibration near the natural frequency of the sprung mass. The perfomance of the control system considering the wheel hop is compared with that of a LQ control system.

  • PDF

가변 동흡진기 구축을 위한 예비 실험 (Preparatory Experiment on the Construct ion of Tunable Dynamic Absorber)

  • 박종훈;한상보
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.329-334
    • /
    • 2002
  • Preliminary test for the design and construction of a tuned dynamic absorber is a conducted. Proposed tuned dynamic absorber is a cantilevered beam type, and is supposed to adjust its natural frequency according to the changing operation condition of the primary system. The modal mass of the dynamic absorber is the easiest to control, therefore, the position of the attached mass of the dynamic absorber is considered as the main design parameter of the absorber. The effect of the dynamic absorber is experimentally verified under various operation conditions of the primary system.

  • PDF

열회수장치에 의한 열교환 성능 분석(농업시설) (Analysis of Heat Exchanging Performance of Heat Recovering Device Attached to Exhaust Gas Duct)

  • 서원명;강종국;윤용철;김정섭
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.333-339
    • /
    • 2000
  • This study was performed to investigate the performance of heat recovery device attached to exhaust gas funnel connected to combustion chamber of greenhouse heating system. The experiment heat recovery system is mainly consisted of LPG combustion chamber and two heat recovery units; unit-A is attached directly to the exhaust gas funnel, and unit-B is connected with unit-A. Heat recovery performance was evaluated by estimating total energy amount by using enthalpy difference between two measurement points together with mass flow rate of gas and/or air passing through each heat recovery unit depending on 5 different flow rates controlled by voltage meter. The results of this experimental study, such as heat exchange behavior of supply air pipes and exhaust air passages crossing the pipes, pressure drop between inlet and outlet, heat recovery performance of exchange unit, etc., will be used as fundamental data for designing optimum heat recovery device to be used for fuel saving purpose by reducing heat loss amounts mostly wasted outside of greenhouse through funnels.

  • PDF