• Title/Summary/Keyword: a RPE

Search Result 147, Processing Time 0.029 seconds

New virtual orthodontic treatment system for indirect bonding using the stereolithographic technique

  • Son, Kyoung-Hoi;Park, Jae-Woo;Lee, Dong-Keun;Kim, Ki-Dal;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.41 no.2
    • /
    • pp.138-146
    • /
    • 2011
  • The purpose of this article is to introduce a new virtual orthodontic treatment (VOT) system, which can be used to construct three-dimensional (3D) virtual models, establish a 3D virtual setup, enable the placement of the virtual brackets at the predetermined position, and fabricate the transfer jig with a customized bracket base for indirect bonding (IDB) using the stereolithographic technique. A 26-year-old woman presented with anterior openbite, crowding in the upper and lower arches, and narrow and tapered upper arch, despite having an acceptable profile and balanced facial proportion. The treatment plan was rapid palatal expansion (RPE) without extraction. After 10 days of RPE, sufficient space was obtained for decrowding. After a 10-week retention period, accurate pretreatment plaster models were obtained using silicone rubber impression. IDB was performed according to the protocol of the VOT system. Crowding of the upper and lower arches was effectively resolved, and anterior openbite was corrected to normal overbite. Superimposition of the 3D virtual setup models (3D-VSM) and post-treatment 3D virtual models showed that the latter deviated only slightly from the former. Thus, the use of the VOT system helped obtain an acceptable outcome in this case of mild crowding treated without extraction. More cases should be treated using this system, and the pre- and post-treatment virtual models should be compared to obtain feedback regarding the procedure; this will support doctors and dental laboratory technicians during the learning curve.

Organ Induction by Combined Dose of bFGF and HGF in Animal Cap Assay of Early Xenopus laevis Embryos. (Xenopus laevis 초기 배의 동물극 분리배양에서 bFGF와 HGF 혼합처리에 의한 기관유도)

  • 진정효;윤춘식;이호선;박용욱;정선우
    • Journal of Life Science
    • /
    • v.14 no.3
    • /
    • pp.375-384
    • /
    • 2004
  • Fibroblast growth factors (FGFs) are known to induce multiple functions in early development, including mesoderm formation, gastrulation movement and antero-posterior patterning. The induction of mesoderm from Xenopus presumptive ectoderm and the combination effect on inducing organs of bFGF(basic FGF) and HGF (Hepatocyte Growth Factor) were studied. Explants were cultured in the combined solution for 3 days to normal embryo arrive at St. 43. These effects on combined dose were examined by histological experiment and by immunohistochemical method. The concentrations of growth factors were tested in 0, 0.5, 1, 10 and also tested in 50 ng/ml of bFGF, and 0, 1, 10, 50 and 100ng/ml of HGF respectively. The synergistic effects were seen in the combined-dose of bFGF and HGF rather than in single dose. Various organs were differentiated and highest inducing effects were seen at the combined concentration of 1 ng/ml of bFGF and 10ng/ml of HGF, and at the concentration 10ng/ml of bFGF and 1 ng/ml of HGF. The bFGF induces various organs from cultured animal cap explants and the effects are time and dose-dependent. HGF is also a potent mitogen for renal tubular cells and for mature hepatocytes in primary culture. Eyes were developed in high percentage at the combined concentration of 1 and 10ng/ml of bFGF, and 1 and 10 ng/ml of HGF. From the induced eye and normal embryonic eye, RPE65 was commonly detected by monoclonal antibodies 40All and 25F5 and the localization of RPE65 was seen by AP reaction.

Remote Plasma Enhanced-Ultrahigh Vacuum Chemical Vappor Deposition (RPE-UHVCD)법을 이용한 GaN의 저온 성장에 관한 연구

  • 김정국;김동준;박성주
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.108-108
    • /
    • 1998
  • 최근의 GaN에 관한 연구는 주로 MOCVD법과 MBE법이 이용되고 있으며 대부분 800¬1$\alpha$)()t 정도의 고옹에서 이루어지고 었다. 그러나 이러한 고온 성장은 GaN 성장 과청에서 질 소 vacancy를 생성시켜 광특성을 저하시키고 청색 발광충인 InGaN 화합물에 In의 유입울 어 렵게 하며 저온에서보다 탄소 오염이 증가하는 동의 문제캠을 가지고 있다. 이러한 고온 생장 의 문제점을 해결하기 위한 방법중의 한 가지로 제시되고 있는 것이 저온 성장법이다. 본 연구 에 사용된 RPE-UHVCVD법은 Nz률 rf plasma로 $\sigma$acking하여 공급함으로써 NI-h롤 질소원으 로 사용하는 고온 성장의 청우와는 다르게 온도에 크게 의존하지 고 질소원올 공급할 수 있 어 저옹 성장이 가능하였다. 기판으로는 a - Alz03($\alpha$)()1)를 사용하였고 3족원은 TEGa(triethylgallium)이며,5족원으로는 6 6-nine Nz gas를 rf plasma로 cracking하여 활성 질소원올 공급하였다 .. Nz plasma로 질화처리 를 한 sapphire 표면 위에 G따애 핵생성충을 성장 옹도(350 t, 375 t, 400 t)와 성장시간(30 분,50 분) 그리고 VIllI비(1$\alpha$)(), 2뼈)둥을 변화시키면서 성장시킨 후 GaN 에피택시충을 450 $^{\circ}C$에서 120 분 동안 성장시켰다 .. XPS(x-ray photoelectron spectroscopy), XRD(x-ray d diffraction), AFM(atomic force microscope)둥올 이용하여 표면의 조성 및 morphology 변화와 결정성을 관찰하였다. X XPS 분석 결과 질화처리를 한 sapphire 표면에는 AlN가 형성되었다는 것을 확인 할 수 있 었으며 질화처리를 한 후 G따J 핵생성충올 성장시킨 경우에 morphology 변화를 AFM으로 살 펴본 결과 표면에 facet shape의 island가 형성되었고 이러한 결파는 질화처리 과청이 facet s shape의 island 형성을 촉진시킨다는 것을 알 수 있었다. 핵생성충의 성장온도가 중가함에 따 라 island의 모양은 round shape에서 facet shape으로 변화하였다. 이러한 표면의 morphology 변화와 GaN 에피택시충의 결정성과의 관계를 살펴보면 GaN 에피택시충 표면의 rms(root m mean square) roughness가 중가하는 경 우 XRD (j -rocking curve의 FWHM(full width half m maximum) 값이 감소하는 것으로 나타났다. 이러한 현상은 결정성의 향상이 columnar 성장과 관계가 었다는 것올 알 수 있었다 .. columnar 성장은 결함의 밀도가 낮은 column의 형생과 G GaN 에피택시충의 웅력 제거로 인해 G값{의 결정성을 향상시킬 수 있는 것으로 생각된다. 톡 히 고온 성장의 경우와는 달리 rms roughness의 중가가 100-150 A청도로 명탄한 표면올 유 지하면서 결정성을 향상시킬 수 있었다. 본 실험에서는 핵생성충올 375 t에서 30 분 생장시킨 경우에 hexagonal 모양의 island로 columnar 성장을 하였고 GaN 에피태시충의 결정성도 가장 향상되었다 이상의 결과로부터 RPE-UHVCVD법용 이용한 GaN 저온 성장에서도 GaN의 결청성올 향 상시킬 수 있음융 확인할 수 있었다.

  • PDF

THE BONE CHANGES OF THE MIDPALATAL SUTURE AFTER RAPID PALATAL EXPANSION IN YOUNG ADULT DOGS (유성견에서 상악골 급속확장 후 정중구개봉합부에서의 골조직 변화)

  • Park, Chang-Wook;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.27 no.3 s.62
    • /
    • pp.391-399
    • /
    • 1997
  • Rapid palatal expansion(RPE) is a method of inducing the new bone formation in the palate by separation of the midpalatal suture, which can be done conveniently by placing heavy force across the maxillary dental arch. This experiment was undertaken to examine the histologic changes after RPE and during retention period. Four young adult dogs(a control dog, three experimental dogs) aged 4 to 6 months old were used for this experiment. Expansion screw($Hyrax^{\circledR}$, Dentarum Inc.) was delevered to the palate and fumed 180 degrees every morning and evening for 8 days, giving a total expansion of 7.2mm. A control dog was sacrified at the starting point of this study without any treatment and three experimental dogs were sacrified after RPE, 14-day retention, and 28-day retention in each. Thereafter, those samples were observed with hematoxylin-eosin(H-E) stain, ground section(Villanueva stain), alkaline phosphatase(ALP) stain, tartrate-resistant acid phosphatase(TRA) stain. The results were as followings: 1. After RPE, collagen fiber bundles were stretched along the midpalatal suture and few osteoblasts were flattened-inactive state and also, a little osteoid tissues was observed. Few multinucleated osteoclasts which had TRAP-positive activity in their cytoplasm were seen in horizontal section, whereas a few osteoclasts were seen in frontal section, especially in the nasal floor side of palatal bone. 2. After 14-day retention, collagen fiber bundles were stretched along the midpalatal suture and few osteoblasts which had ALP-positive activity in their cytoplasm were seen. Few multinucleated osteoclasts which had TRAP-positive activity in their cytoplasm were seen in horizontal section, whereas a few osteoclasts were seen in frontal section, especially in the nasal floor side of palatal bone. 3. After 28-day retention, collagen fiber bundles were arranged like those of control dog and osteoblasts which showed a lot of immature bone formation were cuboidal shape and exhibited ALP-positive activity in their cytoplasm. Few multinucleated osteoclasts which had TRAP-positive activity in their cytoplasm were seen in horizontal section, whereas a few osteoclasts were seen in frontal section, especially in the nasal floor side of palatal bone. According to the above results, the new bone formation after rapid palatal expansion was examined after 14-day retention and significantly increased after 28-day retention.

  • PDF

Plyometrics and vibration: no clear winner on efficacy

  • Hubbard, R. Jeremy;Petrofsky, Jerrold S.;Lohman, Everett;Berk, Lee;Thorpe, Donna
    • Physical Therapy Rehabilitation Science
    • /
    • v.3 no.2
    • /
    • pp.86-92
    • /
    • 2014
  • Objective: Whole body vibration (WBV) and plyometrics are common training techniques which increase strength, blood flow, and lower body force and power. The effects these techniques have on sedentary population is unknown. It is our aim to assess the effectiveness of WBV and plyometrics on sedentary population. Design: Experimental study. Methods: Twenty-seven sedentary subjects were assigned to either the control group, jumping only group, or jumping with vibration group. Jump height (myotest or vertec), velocity, force, blood lactates, and rating of perceived exertion (RPE). Subjects were measured on the initial, seventh, and eighteenth visits. Control group attended measurements only. Jumping only and jumping with vibration groups performed jumping from a vibrating platform to a surface 7 1/2 inches higher for 3 bouts of 20 seconds. Each subject in jumping only and jumping with vibration groups attended three times per week for six weeks. Vibration was set at 40 Hz and 2-4 mm of displacement. Results: There was no significant change among groups in force, velocity, vertec height, and myotest height. However there was a significant increase in vertec height from initial to final measure (p<0.05) for jumping with vibration group. RPE was significantly higher between control group and jumping with vibration group after intervention (p<0.05). Conclusions: WBV with vibration increased jump height. Jumping with vibration group experienced increased exertion than for controls. WBV with plyometrics had no effect on force, velocity, blood lactates, or calculated jump height. Further studies controlling for initial measure of blood lactates and using an external focus may be necessary to elicit velocity, force and jump height changes.

Workload Evaluation of Various Shoulder Posture by using Muscle Force, Fatigue and Psychophysical Workload

  • Park, Ji-Soo;Kim, Jung-Yong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.2
    • /
    • pp.281-289
    • /
    • 2012
  • Objective: The purpose of this study is to evaluate the potential risk of shoulder muscle at particular working postures in sitting. Background: The cause of shoulder pain needs to be specifically studied in relation with particular shoulder postures to prevent shoulder MSDs in workplace. Method: In this study MVC, fatigue and subjective workload were investigated depending on the change of shoulder posture. An experiment was designed to evaluate the six shoulder muscles at nine shoulder postures including the combination of 30(adduction), 0, 30(abduction) degrees and 60, 90, and 120 degrees of shoulder flexion. Surface electrodes were attached to the middle trapezius, inferior middle trapezius, anterior deltoid, posterior deltoid, serratus anterior and teres major. Thirteen subjects participated in the experiment. Dependent variables were RPE (rating of perceived exertion), MVC(maximum voluntary contraction) and MPF(mean power frequency) shift by EMG (electromyography). Results: The middle trapezius and inferior middle trapezius were not significantly fatigued at all postures. The decline of MPF slope was less than 10% at all postures. The anterior deltoid was significantly fatigued all postures. The decline of MPF slope was more than 10% at all postures. The posterior deltoid was significantly fatigued 30 degrees of adduction and 90 degrees of flexion. And, neutral and 30 degrees of abduction postures were fatigued more than 90 degrees of flexion. The serratus anterior was significantly fatigued except for 30 degrees of adduction and 60 degrees of flexion posture. The teres major was significantly fatigued except for neutral and 60 degrees of flexion, 30 degrees of abduction and 60 degrees of flexion posture. Conclusion: It was found that a certain muscle was fatigued fast at particular posture compared to other muscles, which would mean that a certain shoulder muscle at particular posture could be easily exposed to the risk of musculoskeletal disorders than other muscles. Application: It is expected that the result can be applied to design workplace using shoulder muscles.

A Comparative Performance Study of Speech Coders for Three-Way Conferencing in Digital Mobile Communication Networks (이동통신망에서 삼자회의를 위한 음성 부호화기의 성능에 관한 연구)

  • Lee, Mi-Suk;Lee, Yun-Geun;Kim, Gi-Cheol;Lee, Hwang-Su;Jo, Wi-Deok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.1E
    • /
    • pp.30-38
    • /
    • 1995
  • In this paper, we evaluated the performance of vocoders for three-way conferencing using signal summation technique in digital mobile communication network. The signal summation technique yields natural mode of three-way conferencing, in shich the mixed voice signal from two speakers are transmitted to a third person, though there has been no useful speech coding technique for the mixed voice signal yet. We established Qualcomm code term prediction (RPE-LTP) vocoders to provide three-way conferencing using signal summation techinique. In addition, as the conventional speech quality measures are not applicable to the vocoders for mixed voice signals, we proposed two kinds of subjective quality measures. These are the sentence discrimination (SD) test and the modified degraded mean opinion score (MDMOS) test. The experimental results show that the output speech quality of the VSELP vocoder is superior to other two.

  • PDF

Comparison of the Anaerobic Threshold Level Between Subjects With and Without Non-Specific Chronic Low Back Pain (비특이성 만성요통 유무에 따른 무산소성 역치수준 비교)

  • Seong, Jun-Hyuk;Kwon, Oh-Yun;Yi, Chung-Hwi;Cynn, Heon-Seock;Cho, Young-Ki
    • Physical Therapy Korea
    • /
    • v.18 no.1
    • /
    • pp.74-82
    • /
    • 2011
  • The purpose of this study was to compare the anaerobic threshold (AT) between subjects with and without non-specific chronic low back pain (NCLBP). The patient group included 15 women with NCLBP. The normal group included 15 women without NCLBP who were age-, height-, weight-, and activity level-matched. The subjects performed a Balke treadmill protocol which was symptom-limited progressive loading test. Their heart rate (HR), ventilatory gas and metabolic equivalents (METs) were measured using the automatic breath gas analyzing system. After the test, each subjects' ratings of perceived exertion (RPE) were evaluated. The visual analog scale (VAS) was assessed pre- and post-test. The independent t-test and Wilcoxon's signed-rank test were used for analysis of the data. Time, HR, the volume of oxygen consumption ($VO_2$), relative $VO_2$, and METs at the AT level of the patient group were significantly lower than those of the healthy group (p<.05). However, there were no significant differences in RPE, VAS, and breathing frequency at the AT level (p>.05). The findings of this study indicate that patients with NCLBP had a lower aerobic fitness than healthy subjects. Thus, implementation of rehabilitation program to increase aerobic fitness may be considered in patietns with NCLBP, and further studies are required to determine the etiological factors of decreased aerobic fitness.

Nrf2-mediated activation of HO-1 is required in the blocking effect of compound K, a ginseng saponin metabolite, against oxidative stress damage in ARPE-19 human retinal pigment epithelial cells

  • Cheol Park;Hee-Jae Cha;Kyoung-Seob Song;Heui-Soo Kim;EunJin Bang;Hyesook Lee;Cheng-Yun Jin;Gi-Young Kim;Yung Hyun Choi
    • Journal of Ginseng Research
    • /
    • v.47 no.2
    • /
    • pp.311-318
    • /
    • 2023
  • Background: The beneficial effects of compound K (CK) on different chronic diseases have been shown to be at least related to antioxidant action. Nevertheless, since its antioxidant activity in human retinal pigment epithelial (RPE) cells is still unknown, here we investigated whether CK alleviates oxidative stress-stimulated damage in RPE ARPE-19 cells. Methods: The cytoprotective consequence of CK in hydrogen peroxide (H2O2)-treated cells was evaluated by cell viability, DNA damage, and apoptosis assays. Fluorescence analysis and immunoblotting were performed to investigate the inhibitory action of CK on reactive oxygen species (ROS) production and mitochondrial dysfunction. Results: H2O2-promoted cytotoxicity, oxidative stress, DNA damage, mitochondrial impairment, and apoptosis were significantly attenuated by CK in ARPE-19 cells. Furthermore, nuclear factor erythroid 2-related factor 2 (Nrf2) phosphorylation level and its shuttling to the nucleus were increased, which was correlated with upregulated activation of heme oxygenase-1 (HO-1). However, zinc protoporphyrin, a blocker of HO-1, significantly abrogated the preventive action of CK in H2O2-treated ARPE-19 cells. Conclusion: This study indicates that activation of Nrf2/HO-1 signaling by CK plays an important role in rescuing ARPE-19 cells from oxidative cellular damage.

Intercomparison Exercise at Harshaw 6600, DVG-02TM, and D-Shuttle Dosimeters for the Individual Monitoring of Ionizing Radiation

  • Kim, Dmitriy Spartakovich;Murayama, Kentaro;Nurtazin, Yernat;Koguchi, Yasuhiro;Kenzhin, Yergazy;Kawamura, Hiroshi
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.2
    • /
    • pp.79-88
    • /
    • 2019
  • Background: The main goal of experiments is to compare various operational and technical characteristics of D-Shuttle semiconductor personal dosimeters of the Japanese company "Chiyoda Technol Corporation" and Harshaw thermoluminescent dosimeters (TLD) manufactured by "Thermo Fisher Scientific" and DTL-02 of the Russian Research and Production Enterprise (RPE) "Doza" by their occupational and calibration exposure at various dose equivalents from 0.5 to 20 mSv of gamma-radiation. Materials and Methods: Besides dosimeters DTL-02, D-Shuttle and Harshaw TLD, there were also used: (1) the primary reference radionuclide source Hopewell Designs IAEA: G10-1-12 with $^{137}Cs$ isotope (an error is not more than 6% and activity is 20 Ci), and (2) the verification device UPGD-2M of RPE "Doza" and installed in the National Center for Expertise and Certification of the Republic of Kazakhstan (Kapchagai, the National Center for Expertise and Certification). Results and Discussion: The main results of researches are the following: (1) TLDs for Harshaw 6600 and DVG-02TM have an approximately equal measurement accuracy of the individual dose equivalents in the range from 0.5 to 20 mSv of gamma-radiation. (2) Advantages of dosimeters for Harshaw 6600 are due to the high measurement productivity and opportunity to indicate the dose on the skin $H_p$(0.07). Advantages of DVG-02TM consist of operation simplicity and lower cost than of Harshaw 6600. (3) D-Shuttles are convenient for use in the current and the operational monitoring of ionizing radiation. Measurement accuracy and 10% linearity of measurements are ensured when D-Shuttle is irradiated with dose equivalents below 1 mSv at the equivalent dose rate not higher than $3mSv{\cdot}hr^{-1}$. This allows using D-Shuttle at a routine technological activity. Conclusion: The obtained results of experiments demonstrate advantages and disadvantages of D-Shuttle semiconductor dosimeters in comparison with two TLD systems of DVG-02TM and Harshaw 6600.