• 제목/요약/키워드: Zs

검색결과 69건 처리시간 0.021초

Management of Reproduction on Small, Medium and Large Rabbit Farms: A Review

  • Szendro, Zs.;Szendro, K.;Zotte, A. Dalle
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제25권5호
    • /
    • pp.738-748
    • /
    • 2012
  • One of the main goals of small, medium and large farms is to improve the reproductive performance of rabbit does. Stocks of lower productivity can be improved by crossing with intensive breeds. A better nutritional status of both foetuses and suckling kits has a positive effect on their later productivity. Overfeeding young females before first mating can lead to conditions of fattiness. Using restricted feeding or higher fibre content in the feed and changing it for a higher level ad libitum feeding about one week prior to first mating leads to longer lifespan and higher productive level. Intensive reproductive rhythm creates a negative energy balance in does : they are unable to consume enough feed (energy) for the nutritional requirements of foetus and lactation, and therefore lose most of their fat reserves. Furthermore, primiparous does also expend energy because they are still growing. Under intensive conditions, the 42-d reproductive rhythm (re-mating 11 days after parturition) is recommended. Under extensive conditions, the 18 or 25-d mating interval with 35 to 42-d weaning could be suitable. On small farms, natural mating is favoured; on large farms AI is commonly employed. The main advantage of AI is the all-in, all-out system. Hormonal (PMSG) treatment is used with AI to increase receptivity on d 11. Frequent and high level PMSG use can lead to higher anti-PMSG antibody rates. Lower level (max. 20 IU) and less frequent PMSG injection or non-hormonal alternative methods (short dam-litter separation, changing nursing method or lighting programs) are recommended for this reason.

Formulation of Microemulsion Systems for Transdermal Delivery of Aceclofenac

  • Lee, Jae-Hwi;Lee, Yoon-Jin;Kim, Jong-Seok;Yoon, Mi-Kyeong;Choi, Young-Wook
    • Archives of Pharmacal Research
    • /
    • 제28권9호
    • /
    • pp.1097-1102
    • /
    • 2005
  • An O/W microemulsion system was developed to enhance the skin permeability of ace-clofenac. Of the oils studied, Labrafil? M 1944 CS was chosen as the oil phase: of the microemulson, as it showed a good solubilizing capacity. Pseudo-ternary phase diagrams were constructed to obtain the concentration range of oil, surfactant, Cremophor ELP, and co-surfactant, ethanol, for micoemulsion formation. Eight different formulations with various values of oil of $6-30\%$, water of $0-80\%$, and the mixture of surfactant and co-surfactant (at the ratio of 2) of $14-70\%$. The in vitro transdermal permeability of aceclofenac from the microemulsions was evaluated using Franz diffusion cells mounted with rat skin. The level of aceclofenac permeated was analyzed by HPLC and the droplet size' of the microemulsions was characterized using a Zetasizer Nano-ZS. Terpenes were added to the microemulsions at a level of $5\%$, and their effects on the skin permeation of aceclofenac were investigated. The mean diameters of the microemulsions ranged between approximately $10\~100nm$, and the skin permeability of the aceclofenac incorporated into the microemulsion systems was 5-fold higher than that of the ethanol vehicle. Of the various terpenes added, limonene had the best enhancing ability. These results indicate that the microemulsion pystem studied is a promising tool for the percutaneous delivery of aceclofenac.

Z세대 소비자를 움직이는 힘, 한정판 (Motivation for Z generation to consume limited edition products)

  • 이은지
    • 문화기술의 융합
    • /
    • 제9권4호
    • /
    • pp.61-66
    • /
    • 2023
  • 과거, 희소성 있는 제품을 구매하는 것은 고가의 명품을 구매하는 것에 지나지 않았다. 그러나, 현재 한정판 제품을 구매하기 위해서는 지불 능력보다 해당 제품을 구매하기 위한 정보력과 부지런함이 중요 요인이 되었다. 이에 본 연구에서는 Z 세대의 새로운 소비문화의 형태로 자리 잡고 있는 1) 한정판 제품 구매 동기를 심층적으로 알아보고, 더 나아가 2) 한정판 제품 구매 동기가 소비자의 경험(가격, 향후 구매의향)에 미치는 영향을 탐색적으로 알아보았다. 그 결과, 5가지 주요 구매 동기(유행동조, 관심사 충족, 희소성 추구, 재테크, 인정 욕구)를 추출하였고, 이 중 관심사 충족은 제품 구매 가격에 정적인 영향을 미쳤으며, 유행 동조는 제품 구매 가격에 부적인 영향을 미쳤다. 다음으로, 관심사 충족과 희소성 추구 동기는 향후 구매 의향에 정적으로 유의미한 영향을 미치는 것을 밝혔다. 본 연구를 통해, 현재 새로운 소비문화의 주 연령층으로 떠오르는 20대들의 구매 경험에 영향을 미치는 동기를 밝힐 수 있었으며, 이러한 구매 동기들이 구매 물건을 되파는 리셀(resell)마켓과 같은 새로운 소비 시장에 적극적으로 활용될 것이라 기대한다.

음성채팅서비스사용자의이용동기와만족감 (Study on Motivation and Satisfaction of Voice Chat Service)

  • 이은지
    • 문화기술의 융합
    • /
    • 제10권1호
    • /
    • pp.205-210
    • /
    • 2024
  • 오늘날 온라인 메신저는 현대인의 주요한 의사소통 도구라 해도 과언이 아니다. 텍스트와 이미지를 기반으로 소통하는 메신저는 물론, 현재는 음성이나 화면 공유를 통해 실시간으로 상호작용할 수 있는 서비스가 MZ 세대에게 활발히 이용되고 있다. 본 연구는 새로운 커뮤니케이션 형태인 음성채팅 서비스 사용자의 이용 동기를 알아보기 보고, 사용자의 경험을 결정하는 요인 중 하나인 만족감에 대한 이용 동기들의 영향을 탐색적으로 알아보고자 하였다. 그 결과, 음성채팅 서비스에 대한 5가지 주요 이용 동기(관계 형성, 유용성, 관계 유지, 의사소통 보완, 거리감 극복)를 추출하였고, 이 중 유용성과 관계 유지 동기가 사용자의 만족감에 정적인 영향을 미쳤다. 본 연구는 비대면 환경에서 소통하는 사용자들의 다양한 니즈는 물론, 그들의 긍정적인 경험을 위해 충족 시켜야 할 요인을 조명하였으며, 이러한 결과는 온라인 커뮤니케이션 시장에 적절하게 활용되어야 할 것이다.

지르코니아 코어의 표면처리방법이 열 가압 세라믹과의 전단결합강도에 미치는 영향 (The Influence of Surface Treatments on Shear Bond Strength between Zirconia Core and Heat Press Ceramic Interface)

  • 박항민;정인성
    • 대한치과기공학회지
    • /
    • 제31권2호
    • /
    • pp.23-30
    • /
    • 2009
  • All-ceramic restorations have gained acceptance among clinicians and patients because of their superior esthetics. Most all-ceramic systems have a 2-layer structure, using a weak veneering ceramic over a strong supporting core. often, failure of all-ceramic restorations occurs when the veneering ceramic fractures, exposing the core material. The purpose of this study was to compare the shear bond strength of heat press ceramic system (Zirpress) to zirconia core with various surface treatments. 10 metal cores and 50 zirconia cores were fabricated and divided into six groups according to surface treatment such as Zirliner application, aluminium oxide blasting, and 9.5% HF etching. Sixty specimens were prepared using Zirpress, veneered 8mm height and 3mm in diameter, over the zirconia cores (n=10). The shear bond strength test was performed in a universal testing machine with a crosshead speed of 1/min. Ultimate shear bond strength data were analyzed with One-way ANOVA and the Scheffe's test (p=.05). Within the limits of this study, the following conclusions were drawn: The mean shear bond strengths (MPa) were: 12.93 for $110{\mu}m$ aluminium oxide blasting/Rexillium III/IPS e.Max Zirpress; 14.92 for $50{\mu}m$ aluminium oxide blasting ${\pm}9.5%$ HF etching/Zirconis core/IPS e.Max Zirpress; 16.37 for $110{\mu}$ aluminium oxide blasting + 9.5% HF etching/Zirconis core/IPS e.Max Zirpress; 12.89 for $200{\mu}$ aluminium oxide blasting + 9.5% HF etching/Zirconis core/IPS e.Max Zirpress; 19.30 for 9.5% HF etching/Zirconis core/IPS e.Max Zirpress; 19.55 for Zirliner/Zirconis core/IPS e.Max Zirpress. The mean shear bond strength for ZNTZH (Zirliner/Zirconis core) and ZNTEH (9.5% HF etching/Zirconis core) were significantly superior to MS110H ($110{\mu}$ aluminium oxide blasting/Rexillium III) and ZS200EH ($200{\mu}$ aluminium oxide blasting + 9.5% HF etching/Zirconis core) (p<0.05).

  • PDF

Lymphoscintigraphy에 이용되는 방사성의약품의 사용제한으로 인한 대체 방사성의약품의 성능평가 (Performance Evaluation of Substitution Radiopharmaceutical according to Restriction of the Radiocolloids in Lymphoscintigraphy)

  • 서영덕;정재훈;문종운;윤상혁;김영석;강세훈;원우재;김석기
    • 핵의학기술
    • /
    • 제13권1호
    • /
    • pp.25-29
    • /
    • 2009
  • Purpose: Several radioactive agents were used for lymphoscintigraphy in breast cancer. But recently, due to the change of local radiopharmaceutical licensing policy and discontinuation of supplies from manufacturer, we could not use many radiocolloids such as $^{99m}Tc$-Antimony Trisulfide Colloid, $^{99m}Tc$-Tin Colloid, $^{99m}Tc$-Human Serum Albumin. So it is necessary to use the substitution radiopharmaceutical. Therefore, this study aims to evaluate the performance of substitution radiopharmaceutical ($^{99m}Tc$-Phytate) including the existing radiocolloids and to set up of the appropriate protocol in lymphoscintigraphy. Materials and Methods: For each radiocolloids ($^{99m}Tc$-Antimony Trisulfide Colloid (ASC), $^{99m}Tc$-Tin Colloid (TC), $^{99m}Tc$-Human Serum Albumin (HSA), $^{99m}Tc$-Phytate) were performed the particle size by Zeta Sizer (Nano-ZS) and we compared the radiolabeling time, procedure and acquisition time for each of the radiocolloids (total 200 patients). For the last time, we made an analysis of image for each of the radiocolloids with our previous report (SJ Jang et al, Korean Nucl Med Mol imaging Vol.41, No.6, Dec 2007). Results: The particle size of each radiocolloids showed A.S.C (50 nm), T.C (310 nm), H.S.A (10.8 nm), $^{99m}Tc$-Phytate (499 nm). The labeling and acquisition time for each of the radiocolloids showed no substantial difference. But there is difference of the labeling time for the A.S.C. because the ASC procedure need to boiling process. There were no significant differences among those radiocolloids (p>0.005) in the identification rate (IR), false negative rate (FNR), and negative predictive value (NPV). Conclusions: $^{99m}Tc$-labeled radiocolloids showed equivalent results in lymphoscintigraphy. Therefore, in this exam of each radiocolloids could be applied appropriate protocol in lymphoscintigraphy.

  • PDF

감시림프절 검사 시 입자크기에 따른 대체 방사성의약품의 유용성평가 (Evaluation on the Usefulness of Alternative Radiopharmaceutical by Particle size in Sentinel Lymphoscintigraphy)

  • 조광모;정영환;최도철;신주철
    • 핵의학기술
    • /
    • 제20권2호
    • /
    • pp.36-41
    • /
    • 2016
  • 1. 목적 현재 감시림프절 검사에는 $^{99m}Tc-Phytate$만 사용한다. 만약 일시적으로 공급이 중단된다면 대체 가능한 방사성의약품이 없는 실정이다. 본 연구에서는 감시림프절 검사의 성공요소 중 방사성의약품의 입자 크기에 중점을 두어 핵의학 검사에 사용되는 방사성의약품들의 입자크기를 측정해보고 감시림프절 검사 시 $^{99m}Tc-Phytate$를 대체할 수 있는 방사성의약품을 찾아보고자 하였다. 2. 방법 Zetasizer Nano ZS90 (Malvern, UK)를 통하여 체내검사에 이용되는 Phytate, MAG3, DPD, DMSA, MAA, DTPA, HDP의 입자크기를 분석하였다. 동물실험은 9주령의 백서 6마리를 사용하여 각각 3마리씩 $^{99m}Tc-Phytate$를 사용한 대조군과 감시림프절 검사 시 유용하다고 알려진 입자크기를 갖는 $^{99m}Tc-MAG3$, $^{99m}Tc-DPD$$^{99m}Tc-DMSA$를 사용한 실험군을 설정 하였다. 백서의 발등에 11.1 MBq ($300{\mu}Ci$)을 인슐린 주사기를 이용하여 피하주사 하고, 동적영상과 정적지연영상을 획득한 후 육안으로 서혜부 림프절을 관찰하였다. 3. 결과 나노입자 분석기를 통하여 측정한 입자크기는 각각 Phytate 105~255 nm ($81.9{\pm}23%$), MAG3 91~255 nm ($98.7{\pm}17%$), DPD 105~342 nm ($77.3{\pm}11%$), DMSA 164~342 nm ($99.2{\pm}35%$), MAA 1281~2305 nm($90.6{\pm}82%$), DTPA 342~1106 nm ($79.4{\pm}28%$), HDP 295~955 nm ($94{\pm}33%$)로 나타났다. $^{99m}Tc-Phytate$를 사용한 대조군은 모든 실험에서 서혜부 림프절을 육안으로 확인 할 수 있었다. $^{99m}Tc-Phytate$와 가장 유사한 크기의 $^{99m}Tc-MAG3$는 서혜부 림프절에 저류하지 않고 빠르게 통과하였고, $^{99m}Tc-DPD$$^{99m}Tc-DMSA$를 이용한 실험에서는 서혜부 림프절에 대조군과 비슷하게 저류되어 림프절 관찰이 용이하였다. 결론: 본 실험을 통해서 핵의학 체내검사에 사용되는 방사성의약품들의 입자크기 분포를 확인하였다. $^{99m}Tc-MAG3$$^{99m}Tc-Phytate$와 가장 유사한 입자크기를 가지고 있으나 동물실험에서는 서혜부 림프절이 관찰되지 않고 빠르게 신장을 통해 배출되었다. 반면에 $^{99m}Tc-DPD$$^{99m}Tc-DMSA$의 경우 유사시 대체 방사성의 약품으로 사용 될 수 있을 것으로 생각된다.

  • PDF

냉간 정수압 성형법으로 제작된 지르코니아 코어의 적합도에 관한 연구 (Adaptability of zirconia core fabricated by cold isostatic pressing)

  • 서윤정;윤귀덕;김현승;박상원
    • 대한치과보철학회지
    • /
    • 제48권2호
    • /
    • pp.143-150
    • /
    • 2010
  • 연구목적: 본 연구의 목적은 냉간 정수압 성형법 (cold isostatic press forming)을 이용한 새로운 지르코니아 블록의 제조와 이를 이용한 코어와 완전 도재관의 적합도를 비교 평가하여 임상적 이용 가능성을 평가 하고자 함이다. 연구 재료 및 방법:지르코니아 분말 (KZ-3YE Type A)을 단일 압축 성형하여 블록의 형태로 제작 한 후, 냉간 정수압 성형하여 블록을 제작하고, 성형이 끝난 지르코니아 블록은 $1040^{\circ}C$의 온도에서 반 소결하였다. 대조군은 상용 제품 ($Everest^{(R)}$, KAVO, Biberach/$Ri{\beta}$.)을 이용하였다. $1450{^{\circ}C}$의 온도에서 완전 소결된 실험군 블록과 대조군 블록의 수축률을 측정하고 비교하였다. CAD/CAM을 이용하여 총 21개의 코어를 제작하고 세 그룹으로 나누었다. Group I은 대조군 블록을 이용해 7개의 코어를 제작하고, Group II는 실험군 블록을 이용해 7개의 코어를 제작하였다. Group III은 실험군 블록을 이용해 7개의 코어를 제작하고 도재 ($Cerabien^{TM}$)를 축성하여 완전 도재관을 제작하였다. 제작된 코어와 완전 도재관을 모형에 합착한 후 레진으로 매몰하여 치관 장축의 협설과 근원심 방향을 따라 절단하고 지대치와 코어 사이의 변연 간격과 내부 축면 간격 그리고 내부 교합면 간격을 SEM ($S-4700^{(R)}$)을 이용해 측정하였다. 모든 측정값은 평균과 표준편차를 계산하고, one-way ANOVA test를 시행하여 실험 결과를 분석하였고, 95%유의 수준으로 검정하였다. 결과:실험군과 대조군 블록의 수축률을 측정한 결과 실험군 블록의 수축률은 19.00%였고, 대조군 블록의 수축률은 20.09%로 실험군 블록의 수축률이 더 낮은 것으로 나타났다. 적합도 측정 결과 변연 간격의 측정값에서 Group II의값($29.67{\pm}6.58 {\mu}m$)이 Group I의값($36.84 {\pm}7.18 {\mu}m$)보다 통계적으로 유의하게 작은 것으로 나타났다. 또한 Group II와 Group III의 값 사이에서는 유의한 차이가 없었다. 내부 측면 간격의 측정값에서 Group III의값($32.23{\pm}6.33 {\mu}m$)이 Group I와 Group II의내부측면간격의값($37.57{\pm}6.81{\mu}m$, $38.14{\pm}6.81{\mu}m$)보다 큰 것으로 나타났다. 각 부위의 간격 측정결과 내부 교합면 간격의 값이 변연 간격 및 내부 축면 간격의 값보다 유의하게 큰 것으로 나타났다. 결론: 현재 상용중인 대조군 블록과 비교하여 냉간 정수압 성형법으로 제조된 실험군 블록의 적합도는 유의한 차이를 보이지 않았다. 변연 적합도는 실험군에서 더 우수하였으며 도재를 축성한 완전 도재관의 적합성이 약간 더 향상되는 경향을 보였다. 변연 적합도는 대조군과 실험군 모두에서 임상적으로 허용되는 양호한 수치를 보였다.

염화수화물용액 침지법으로 제작한 유색 지르코니아와 전장도재의 전단결합강도 (Shear bond strength of veneer ceramic and colored zirconia by using aqueous metal chloride solutions)

  • 윤귀덕;유수경;방몽숙;양홍서;김현승;박상원
    • 대한치과보철학회지
    • /
    • 제48권2호
    • /
    • pp.151-157
    • /
    • 2010
  • 연구목적: 본 연구의 목적은 금속염화물 용액 내 침지법으로 제작된 유색 지르코니아 블록의 임상적 응용을 타진해보기 위해 지르코니아 코어와 전장도재간의 전단결합강도를 평가하고자 함이다. 연구 재료 및 방법: 지르코니아 블록은 자체 제작한 것과 시판되는 제품을 이용하였다. 색소체 용액으로 크로뮴과 몰리브데늄을 포함하는 3가지 염화수화물 용액을 제조하였고, 대조군으로 상용되고 있는 색소체 용액을 준비하였다. 가로 5 mm, 세로 5 mm, 높이 10 mm의 직육면체 지르코니아 시편을 블록마다 40개를 제작하였고, 시편을 임의로 5개 그룹으로 나누어 색소체 용액에 침지하여 유색 지르코니아를 제작한 후, 도재를 가로 5 mm, 세로 5 mm, 높이 4 mm의 직육면체가 되도록 축성하고 소결하였다. 시편의 최대 하중값과 전단결합강도를 측정하고 파절된 시편의 파절면과 파절 양상을 검사하였다. 결과:1. 지르코니아 블록간의 전단결합강도는 통계학적으로 차이를 보이지 않았다 (P > .05). 2. 무색 지르코니아와 유색 지르코니아 간의 전단결합강도는 무색이 높은 경향을 보였으나 통계학적으로 유의한 차이는 보이지 않았다 (P > .05). 3. 유색 지르코니아의 전단결합강도 비교 시 색소체 용액의 종류에 따른 통계학적인 차이는 보이지 않았다 (P > .05). 4. 지르코니아와 전장도재간의 파절은 주로 혼합성 파절 양상이 관찰되었다. 모든 시편의 전장도재 파절은 지르코니아와의 계면이나 전장도재내에서 관찰되었으며 지르코니아의 응집성 파절은 보이지 않았다. 결론:유색 지르코니아와 전장도재의 전단결합강도는 무색 지르코니아보다 더 낮은 경향을 보였지만, 관찰된 수치는 임상적으로 허용 가능한 것으로 사료된다.