• 제목/요약/키워드: ZnO Arrester

검색결과 100건 처리시간 0.03초

직류 전차 탑재형 피뢰기의 하우징 설계 및 성능평가 (Performance Evaluation and Housing Design for Direct Current Surge Arrester in Railway Rolling Stock)

  • 조한구;김석수;한세원;이운용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.128-131
    • /
    • 2000
  • The main objective of this paper is to design and test a new type of polymer ZnO surge arrester for DC power system of railroad vehicles. The rated voltage is 1500V direct current. The main research works are focused on structure design by finite element method, rating voltage, temporary over voltage and studies of characteristics of polymeric surge arrester.

  • PDF

피뢰기 열화진단을 위한 저항분 누설전류의 측정장치 (Measurement Device of Resistive Leakage Current for Arrester Deterioration Diagnosis)

  • 길경석;한주섭;김정배
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권10호
    • /
    • pp.469-475
    • /
    • 2003
  • Resistive leakage current flowing ZnO blocks increases with its ages, which is an important indicator of arrester deterioration. However, a complicated circuitry is essential to measure the resistive leakage current included in the total leakage current, and the difficult handling of the measurement makes few applications to the fields. In this paper, we propose a resistive leakage current measurement device which is composed of a current detection circuit and an analysis program operated on a microprocessor. The device samples the input leakage current waveform digitally, and discriminate the zero-cross and the peak point of the waveform to analyze the current amplitude vs. phase. The capacitive leakage current is then eliminated from the total leakage current by using an algorithm to extract the resistive leakage current only. Also, the device can be operated automatically and manually to analyze the resistive leakage current even when the leakage current waveform is distorted due to various types of arrester deterioration. To estimate the performance of the device, we carried out a test on ZnO blocks and lightning arresters. From the results, it is confirmed that the device could analyze most parameters needed for the arrester diagnostics such as total leakage current. resistive leakage current, and the $3^rd$ harmonic leakage current.

누설전류에 의한 ZnO피뢰기의 열화진단장치 개발 (Development of deterioration arrester detector by leakage current)

  • 오정환;이영길;김재철;한민구;오계환;이복규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.74-76
    • /
    • 1995
  • In this paper, the results of development of arrester leakage current detector using micro computer are described. This detector is based on harmonic analysis of the leakage current by FFT. The change of leakage current is the recognized measure of deterioration. For low sensitivity to disturbance, this device used optical fiber. This will be a great benefit of detecting deterioration ZnO arrester.

  • PDF

배전용 피뢰기사고 조사분석 (The Survey and Analysis on Lightning Arrester Failures in Distribution Systems)

  • 박중신;정종욱;곽희로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2361-2363
    • /
    • 1999
  • The conventional SiC-type of lightning arresters in distribution systems has been replaced by ZnO-type because the ZnO-type has characteristics such as outstanding non linearity, high energy absorption capability, surge suppressing performance, and excellent response to abrupt wave. Out of the various types of lightning arrester failures, some which have been often reported could be prevented in advance. Therefore, the preventive countermeasures which can cope with the failures are strongly required. This paper summed up and analyzed the lightning arrester failures which occurred, from 1983 to 1992, in distribution systems in order to provide fundamental data, classified by year, to make countermeasures.

  • PDF

중첩전압(직류+교류 60Hz)에서 산화아연 피뢰기 소자의 누설전류 특성 (The characteristic of leakage current in ZnO surge arrestor elements with mixed direct and 60Hz voltage)

  • 이복희;박건영;강성만;최휘성;오성균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.186-188
    • /
    • 2003
  • The ZnO surge arrester is the protective device for limiting surge voltages on equipment by diverting surge current and returning the device to its original status. The occurrence of overvoltage appears in any phase to AC power supply system and it appears in mixing AC and impulse voltages, moreover because HVDC power supply system uses converter in semiconductor, it makes mixed DC and high harmonics voltages. In this study, the various mixed AC and DC voltages was made for investigating the degradation effect of ZnO arrester according to mixed voltage. As a result, the increase of DC component to mixed voltages causes the increase of resistive component of total leakage current to ZnO block. In changing V-I curve for mixed voltages, the cross-over point acts a factor as making the proper capacitor size of an equivalent circuit for ZnO block.

  • PDF

피뢰기의 ZnO 소자 성능평가 분석 (Performance Evaluation and Analysis of ZnO Element for Distribution Line Arresters)

  • 김석수;김경운;박영창;조한구;박태곤;송일근;김주용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.78-81
    • /
    • 2000
  • Metal oxide surge arrester were developed in the late 1970s, and were immediately adopted as significant breakthrough in over voltage protection of power system. Work was continued throughout the world on the design, development and application of metal oxide surge arrester. This paper describes the evaluating test and results of practical use for analyzing the performance of gapless metal oxide surge arresters under various type test. In the result, ZnO element exhibited badness rate of 6.95 percent.

  • PDF

전철 탑재형 피뢰기의 모듈설계 및 성능평가기술 (Module Design and Performance Evaluation of Surge Arrester for Loading In Railway Rolling Stock)

  • 조한구;김석수;한세원;이운응
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2038-2040
    • /
    • 2000
  • The main objective of this paper is to design and test a new type of polymer ZnO surge arrester for AC power system of railroad vehicles. Metal oxide surge arrester for most electric power system applications, electric train and subway are now being used extensively to protect overvoltage due to lightning. Surge arresters with porcelain housing must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of ZnO elements in a surge arrester occurs due to flashover, fault short current flows through the arrestor and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock, pressure rise. etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion. The main research works are focused on the structure design by finite element method, pressure relief of module, and studies of performance of surge arrester for electric railway vehicle.

  • PDF

폴리머 피뢰기의 구조에 따른 온도와 누설전류 특성 (Temperature and Leakage Current Characteristics of Polymeric Surge Arrester with Housing)

  • 조한구;유대훈;이운용;김하나
    • 한국전기전자재료학회논문지
    • /
    • 제20권3호
    • /
    • pp.273-280
    • /
    • 2007
  • In this paper, the ZnO surge arrester performance of power distribution class has been studied under different manufacturing conditions such as housing materials(polymeric, porcelain), interface sealants and one-body molding type. In the recent years, the polymeric ZnO surge arresters have been developed and put into operations based on their excellent characteristics. For polymeric surge arresters, the inner gas volume is extremely small, especially in solid insulation polymeric arresters there are not any gas volume inside arresters in the structure due to polymeric materials are filled into the internal gas volume. The sealing integrity is related to safe operation of surge arrester, the prime failure reason of porcelain housed arresters is moisture ingress. In this paper, the sealing integrity of polymeric surge arresters is investigated with moisture multi-aging test and ingress test. The evaluation techniques are used to inspect the sealing integrity of polymeric arresters, including leakage current, surface temperature, reference voltage and dissipation factor.

뇌충격전류에 의한 산화아연형 피뢰기 소자의 전기적 특성과 피뢰기 열화진단 전문가 시스템 (Electrical Characteristics of ZnO Blocks by a Lightning Impulse Current and the Expert System to Diagnose Arrester Deterioration)

  • 길경석;한주섭;송재용;김명진;김정배;조한구
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권4호
    • /
    • pp.152-157
    • /
    • 2002
  • This paper describes an effect of a single- and a quadruple-lightning impulse currents on electrical characteristics of ZnO blocks, and an expert system to diagnose arrestor deterioration. To deduce the parameters needed for diagnosing arrester deterioration, an accelerate deterioration teat is carried out. In the experiment, leakage current components are measured. Also, wave height distribution of the leakage current according to the progress of arrester deterioration is analyzed. From the experimental results, the wave height distribution of the leakage current showed conspicuous difference even in an immaterial leakage current increase. Therefore, the use of wave height distribution of the leakage current in deterioration diagnostic technique makes more accurate diagnosis than the conventional method by using only a leakage currant value. Finally, the expert system based on the experimental results is developed and the system can diagnose arrestor deterioration by measuring the leakage current and its wade height distribution.

산화아연 피뢰기의 열화진단을 위한 저항성누설전류의 고정도 측정기법 및 장치의 개발 (A Development of the High Precise Measuring Device and Methods of Resistive Leakage Current for the Deterioration Diagnosis of ZnO Arrester)

  • 이복희;강성만;전덕규;박건영;최휘성;조성철;백영환;이동환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1668-1670
    • /
    • 2003
  • This paper deals with a development of the high precise measuring device of resistive leakage current for the deterioration and diagnosis of ZnO arresters. The resistive leakage current increasing with time leads to a thermally unstable state that may even experience a disaster. So, the resistive leakage current can be used as an indicator to discriminate whether the ZnO arrester blocks is in good state or in bad. The resistive leakage current measuring system with an analysis program operated with micro-processor using the time delay addition method was designed and fabricated. The proposed measuring systems for the resistive leakage current can effectively be used to develop the techniques of forecasting the deterioration of ZnO arresters in electric power systems.⨀ᔌ?؀㔳㤮㈻Ԁ䭃䑎䷗ᜒं6〰Ԁ䭃䑎䴀

  • PDF