• 제목/요약/키워드: ZnBO

검색결과 265건 처리시간 0.028초

Morphological and biochemical differences in three Undaria pinnatifida populations in Korea

  • Park, Kwang-Jae;Kim, Bo-Yeon;Park, Seo-Kyoung;Lee, Jong-Hwa;Kim, Young-Sik;Choi, Han-Gil;Nam, Ki-Wan
    • ALGAE
    • /
    • 제27권3호
    • /
    • pp.189-196
    • /
    • 2012
  • Twelve morphological characters and the biochemical composition of Undaria pinnatifida f. distans sporophytes growing on the rocky shores of Jindo and Wando and on cultivation ropes in Kijang were measured to determine whether each population could be characterized by morphological features and biochemical composition. The goal of this study was to compare phenotypic variations between populations as they relate to environmental conditions. The sporophytes of the Kijang population were two times longer and 19 times heavier than those at Jindo. Sporophylls of the Jindo U. pinnatifida population were significantly smaller in length, width, frill number, and weight than those at Wando and Kijang. Kijang Undaria plants showed the highest contents of total protein, crude fiber, total amino acids, the amount of essential amino acids, the proportion of total unsaturated fatty acids, and eicosapentaenoic acid. However, the Jindo population showed the greatest content of carbohydrates, lipids, and minerals (Zn and Ca) of the three U. pinnatifida populations. In particular, Zn content of Jindo plants was 30 times greater than that of Kijang plants. Thus, the proximate composition, mineral composition, amino acids, and fatty acids of Undaria pinnatifida plants were distinguishable among the three representative Undaria populations evaluated. These results suggest that morphological and biochemical differences of the three U. pinnatifida populations can be attributed to differences in environmental conditions of their habitats.

에칭법을 이용한 실리콘 웨이퍼 표면 근처에서의 금속 분순물의 정량 (Determination of Metal Impurities at Near Surface of Silicon Wafer by Etching Method)

  • 김영훈;정혜영;조효용;이보영;유학도
    • 대한화학회지
    • /
    • 제44권3호
    • /
    • pp.200-206
    • /
    • 2000
  • 실리콘 웨이퍼를 일정한 두께로 에칭하여 실리콘 웨이퍼 표면 근처의 특정영역에 존재하는 금속불순물을 정량하였다. HF와 $HNO_3$의 부피비를 1:3으로 혼합한 용액 5mL로 20분간 실리콘 웨이퍼와 반응 시켰을 때 1${\mu}m$ 두께로 웨이퍼 전면을 균일하게 에칭할 수 있었다. 에칭 후, 용액을 중발하기 위해 마이크로파 오븐을 사용하였는데 증발과정에서 spike한 Cu, Ni, Zn, Cr, Mg 및 K의 회수율은 99∼105%였다,Cu를 오염시킨 epitaxial 실리콘 웨이퍼의 경우 에칭법으로 전처리를 하여 ICP${\cdot}MS$로 측정한 결과, Cu는 뒷면의 표면으로부터 1∼2${\mu}m$ 안의 polysilicon영역에 집중적으로 분포하였고 Cu 농도를 1${\mu}m$두께의 범위에서 정량할 수 있었다.

  • PDF

급성 카드뮴중독시 랏트의 고환조직내 Catalase 및 Superoxide Dismutase 활성도와의 양-반응관계 (Dose-Response Relationship between Catalase and Superoxide Dismutase Activity in Testes of Acutely Intoxicated Rats by Cadmium)

  • 박보영;박정덕;정규철
    • Journal of Preventive Medicine and Public Health
    • /
    • 제21권2호
    • /
    • pp.295-306
    • /
    • 1988
  • Dose-response relationship among blood cadmium concentrations, catalase and superoxide dismutase activities were studied with acutely intoxicated rats by cadmium. The Sprague-Dawley male rats to which single dose of $1{\sim}32mg/kg\;CdCl_2$ were administered into peritoneal cavity were sacrificed by decapitation at $3{\sim}36$ hours after the administration. Cadmium concentrations in blood increased significantly with dose of $CdCl_2$ administered and reached peak level at 3 hours later. Catalase activities in rats' testes were not correlated with esposure time elapsed after the administration in rats to which $1{\sim}2mg/kg\;of\;CdCl_2$ were administered, but they showed linear relationship with time in groups to which $4{\sim}32mg/kg\;of\;CdCl_2$ were administered. Cu, Zn-SOD activities in testes of acutely intoxicated rats by cadmium were not altered either by dosage or by time elapsed after the administration. Mn-SOD activities in the testes were also not influenced by dosage of $1{\sim}2mg/kg\;CdCl_2$, but remarkably inactivated by dosage of $4{\sim}32mg/kg\;CdCl_2$ with time elapsed after the administration. Neither catalase, Cu, Zn-SOD nor Mn-SOD activities of testes were correlated with blood cadmium concentrations in acutely intoxicated rats by cadmium.

  • PDF

토양세척법에 의한 중금속오염 폐탄처리장 토양의 정화 : 세척액의 선정 (Remediation of Heavy Metal Contamination in OBOD Site with Soil Washing : Selection of Extractants)

  • 이상환;김을영;서상기;김권보;김재환;이종근
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제13권2호
    • /
    • pp.44-53
    • /
    • 2008
  • 폐탄처리과정에서 오염된 중금속 오염토양의 정화에 있어 무기산(HCl), 중성염($CaCl_2$), 킬레이트제(citric acid, $Na_2$-EDTA)들을 이용한 토양세척 가능성을 평가하였다. 실험에 사용된 추출액(HCl, $CaCl_2$, citric acid, $Na_2$-EDTA)들의 추출효율은 HCl > citric acid > $Na_2$-EDTA > $CaCl_2$의 순으로 나타났는데 HCl(1.0 M)에 의해서 Cd, Cu, Pb와 Zn이 초기농도 대비 각각 82%, 86%, 80%, 46% 정도 추출된 것으로 나타났다. 추출효율과 반응액의 pH 간에는 고도의 음의 상관관계가 존재하였다. 폐탄약처리장 부지 토양 중 중금속은 탄산염결합태, Fe, Mn-산화물 결합태 형태로 존재하고 있었는데 HCl, citric acid 세척에 의해서 이들 분획의 현저한 감소가 이루어졌지만 이동성이 상대적으로 큰 치환태가 증가되는 것으로 나타났다. 이동성이 큰 분획의 증가는 지하수 오염 등의 문제를 야기시킬 수 있음으로 이에 대한 적절한 관리가 필요할 것으로 판단된다.

강원도 철원지역과 전라남도 동부지역에 서식하는 한국고라니(Hydropotes inermis argyropus)의 중금속 축적 분석 (Heavy Metal Accumulation Analyses of the Korean Water Deer (Hydropotes inermis argyropus) in Cheorwon, Gangwon Province and the Eastern Part of Jeonnam Province)

  • 박보현;김백준;이상돈
    • 환경생물
    • /
    • 제27권4호
    • /
    • pp.363-368
    • /
    • 2009
  • 한국고라니(Hydropotes inermis argyropus)는 우리나라의 고유종으로 가장 흔한 종의 하나이다. 이 종은 한반도 전역에 널리 분포하며 자연생태계에서 초식자로서 중요한 역할을 하는 것으로 알려져 있다. 따라서 고라니는 서식지의 질을 모니터링하는데 하나의 좋은 생물지표종으로 이용될 수 있을 것이다. 이 연구에서는 강원도 철원지역과 전라남도 동부지역에서 수집된 한국고라니의 서로 다른 3가지 조직(신장, 간, 지라)에서 5가지 중금속(Fe, Cu, Zn, Cd, Pb)의 농도를 측정하였다. 중금속 농도의 분석에 따르면, 철의 농도는 구리, 아연, 카드뮴, 납에 비해 모든 조직에서 높게 나타났다. 이중, 지라(286.50)가 신장(39.40)과 간($23.21\;{\mu}g\;g^{-1}$)에 비해 높은 중금속 축적을 보였다. 일반적으로, 중금속의 농도는 전남 동부지역에 비해 강원도 철원지역에서 조금 높게 나타났다. 특히, 카드뮴과 납의 경우 매우 유의한 차이를 보였다(P<0.05). 이러한 중금속의 농도는 지라의 철을 제외하고는 모두 백그라운드 수준(background level) 내로 낮게 나타났다.

중금속으로 오염된 토양에서 분리한 중금속 내성 미생물의 수용액내 중금속 흡착 (Biosorption of Heavy Metal in Aqueous Solution by Heavy Metal Tolerant Microorganism Isolated from Heavy Metal Contaminated Soil)

  • 김성은;최익원;서동철;한명훈;강병화;허종수;손보균;조주식
    • 한국환경농학회지
    • /
    • 제24권4호
    • /
    • pp.379-385
    • /
    • 2005
  • 중금속으로 오염된 폐수를 처리하기 위하여 다양한 처리 방법들이 제시되고 있으나, 최근에는 미생물을 이용한 중금속 처리 방법에 대한 관심이 높아지고 있다. 따라서 중금속으로 오염된 토양에서 중금속에 대하여 강한 내성과 우수한 생물흡착능력을 동시에 가지고 있는 미생물 CPB를 분리하여 중금속에 대한 내성, 흡착 능력 및 흡착의 최적조건을 조사하였다. 중금속에 대한 내성은 전체적으로 $400mg{\ell}^{-1}$ 이상의 농도에서도 높은 내성을 보였으며, 생장 저해도는 단일 중금속 보다 중금속이 복합으로 존재 할 경우 더 크게 나타났다. 중금속 흡착 능력은 Pb>Cd>Cu>Zn의 순으로 흡착 능력이 나타났다. 외형적 흡착형태는 중금속의 종류에 따라 세포 표면 및 세포 막 부근에 electron dense particles들이 형성되었으며, 이는 EDS 분석을 통하여 중금속 화합물인 것으로 확인되었다. 중금속을 흡착하는데 있어 전반적인 최적 pH는 $5{\sim}7$범위였고, 최적 온도는 $25{\sim}35^{\circ}C$이다.

밀양지역의 PM2.5 농도 및 성분특성 (The PM2.5 Concentration and Components Characteristics in Miryang)

  • 서정민;김영식;전보경;최금찬;류재용;박정호
    • 한국환경과학회지
    • /
    • 제16권12호
    • /
    • pp.1355-1367
    • /
    • 2007
  • This study summarizes the relations among $PM_{2.5}$ concentration, water-soluble ions concentration, metallic element Components characteristics and SPSS in negative ion and metallic element of $PM_{2.5}$ particle in Miryang.(By the urban area, the industrial complex area and the suburban area according to the season) $PM_{2.5}$ concentration of total 72 samples collected from 3 sites turned out to range from 3.47 to 34.7 ${\mu}g/m^3$, and the average concentration was the suburban area-the kin nup(16.00 ${\mu}g/m^3$) > the urban area-the roof of the old Miryang university(10.32 ${\mu}g/m^3$) > the industrial complex-Sapo industrial complex(10.29 ${\mu}g/m^3$). In particular, the suburban area had $PM_{2.5}$ concentration 1.5 times those of urban area, industrial complex. It was thought although the site was suburban and farm-side without pollutants around, it had a higher concentration value influenced by external factors including the brickyard, small-scale incinerator, driving range construction, construction on the Daegu-Busan express and the widening of the four-lane road between Miryang-Anyang nearby. As for water-soluble ions among $PM_{2.5}$ particle collected in Miryang area, $SO4_{2^-}$ accounted for 60% and $NO_{3^-}$, was 30% in spring and summer. And $NO_{3^-}$ accounted for 50% and $SO4_{2^-}$ was 35% in fall and winter. The AI value of metallic Components among $PM_{2.5}$ particle collected in Miryang area had a high value influenced by the apartment complex construction and the extension work of road. The industrial complex area had Zn concentration 3 times, and Fe concentration 2 times those of urban area and suburb area. When it comes to the relation with metallic elements in urban area, the highest coefficient of correlation was between Cr-Fe with 0.85, and Pb-Cd turned out in the reverse correlation. Among metallic elements, the coefficients of correlation between Zn and Cr, Mn, Fe, NI were high in industrial complex area. The highest coefficient of correlation was between Mn-Zn with 0.88, meanwhile Ni and Cu, Cd turned out in the reverse correlation in the suburb area. These coefficients of correlation are attributed to the difference in pollutant sources, rather than difference in pollutant and non-pollutant.

이종 타겟을 지닌 대향 타겟 스퍼터링 방법으로 제작된 AZO 박막의 광학적·전기적 특성에 관한 연구

  • 야오리타오;서성보;배강;김동영;최명규;김화민
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.337-337
    • /
    • 2014
  • 투명 전도성 산화물(transparent conductive oxide: TCO) 박막은 높은 투과율과 낮은 비저항 덕분에 LCD (liquid crystal display), PDP (plasma display panel), OLED (organic light emitting display) 등 평판 디스플레이에 널리 사용되고 있다. 현재 양산되고 있는 ITO (indium tin oxide)는 90% 이상의 높은 투과율과 우수한 전도성으로 인해 TCO 박막 가운데서 디스플레이 산업에서 가장 널리 쓰이고 있다. 그런데, ITO의 인듐산화물에 의한 간질성 폐렴(interstitial pneumonia)의 유발 위험이 있다든가, 인듐의 매장량이 적어 원자재 가격이 비싼 단점도 가지고 있다. 이에 최근 ITO를 대체할 수 있는 TCO물질로 많은 연구가 이루어지고 있는데, 특히 AZO (aluminum-doped zinc oxide)는 그 중 대표적인 대체물질로서 독성이 없고 가격도 저렴하여 많은 관심이 증폭되고 있다. 현재 AZO는 sol-gel 방법이나 CVD (chemical vapor deposition) 또는 스퍼터링 방법 등으로 증착되고 있다. 본 연구에서는 두 개의 이종타겟(hetero target)을 장착한 대향 타겟 스퍼터링(facing target sputtering: FTS) 장치를 사용하여 AZO 박막을 제작한다. 기존의 여러 증착법과 달리, FTS 장치는 두 타겟 사이에 형성되는 플라즈마 내의 ${\gamma}$-전자를 구속하게 되며, 낮은 가스 압력에서 고밀도 플라즈마가 생성되어 빠른 증착 속도와 안정적인 방전을 유지한 상태에서 박막을 증착할 수가 있다. 또한 기판과 플라즈마가 이격되어 있어 높은 에너지를 갖는 입자들의 기판 충돌을 억제할 수 있는 장점들을 갖는다. 이종 타겟인 ZnO와 Al2O3를 사용하고 각 타겟에 인가되는 파워 변화를 통해 AZO 박막 내 Al2O3의 성분비를 조절하였다. ZnO 타겟의 증착 파워를 100 W로 고정할 경우, Al2O3 타겟의 증착 파워가 (50~90) W으로 실험을 하였으며, Al2O3 타겟의 증착 파워가 70 W일 때 AZO 박막의 Al2O3 성분비는 2.02 wt.%이며 박막의 비저항 값은 $5{\times}10^{-4}{\Omega}{\cdot}cm$로 최소값을 보였다. 이러한 비저항의 변화는 파워에 따른 AZO 박막의 캐리어 이동도(Hall mobility)와 캐리어의 농도(Carrier Concentration)의 변화와 밀접한 관계가 있음을 보여주며, 특히 AZO 박막의 캐리어 농도와 캐리어 이동도는 AZO 박막을 형성하고 있는 결정립의 크기에 의존하는 것이 X-선 회절 패턴과 SEM으로부터 확인되었다. 특히, 본 연구에서는 두 개의 이종 타겟(hetero target) Al2O3와 ZnO를 장착하고 각각의 파워를 변화시켜 도핑 량을 조절할 수는 대향 타겟 스퍼터링(FTS: facing-target sputtering) 방법을 이용하여 제작된 AZO 박막에 대해 전기적, 광학적 및 구조적 특성을 분석하고 ITO의 대체물로서의 가능성을 검토하고자 한다.

  • PDF

밀양·창원지역의 PM10 중 음이온 성분 및 금속성분의 화학적 특성에 관한 연구 (A Study on the Chemical characteristics of Anion Components and Metallic Elements of PM10 in Miryang and Changwon)

  • 서정민;전보경;최금찬
    • 한국환경과학회지
    • /
    • 제13권12호
    • /
    • pp.1049-1058
    • /
    • 2004
  • PM10 concentration of total 48 samples collected from 4 sites (the root of Miryang University, Sangnam township Office in Miryang. the root of Changwon elementary school, and Junam reservoir in Changwon) turned out to range from 42.29 to 69.49{\mu}g/m^{3}$, and the average concentration was the root of Changwon elementary school $(69.49{\mu}g/m^{3})$>the root of Miryang university $(58.59{\mu}g/m^{3})$>Junam reservoir $(43.56{\mu}g/m^{3})$>Sangnam township Office $(42.29{\mu}g/m^{3}).> In particular, Junam reservoir, the Clean Area, had a slightly higher value than Sangnam township Office. It was thought although the site was plane and windy without pollutants around. it had a higher concentration value influenced by external factors including bigger population and a northeasterly wind due to a newly-established industrial complex nearby. As for water-soluble ions among PM10 particle collected in Miryang and Changwon area, SO42- accounted for $50{/%}$ and NO3-, was $35{\%}$, and the concentration order was S042->N03->Cl->F-. As for the average concentration of metallic components among PM10 particle collected in Miryang and Changwon area. the root of Changwon elementary school had the AI concentration, Fe concentration and Zn concentration 4 times, 3 times and 1.5 times that of Junam reservoir, respectively. The root of Miryang University had the AI concentration 2 times that of Sangnam township Office, and had Fe concentration and Zn concentration $1.2\~1.5$ times those of Sangnam township Office. When it comes to the relation between metallic elements and meteorological factors in Changwon area, the highest coefficient of correlation was between temperature and humidity with 0.92, and temperature and wind speed turned out in the reverse correlation. The coefficient of correlation between Al and Cr was as high as 0.78. Among metallic elements, the coefficient of correlation between Cu and Pb, Cd, Al were 0.84, 0.85, 0.79, respectively. It is thought that the high coefficient of correlation between Cu and Pb is ascribed to busy traffic and wind in the urban areas, Sammun-dong and Gagok-dong in Miryang. Meanwhile, the coefficients of correlation between Fe and Cu, Al, Zn, Cd, Pb were in the reverse correlation. These coefficients of correlation are attributed to the difference in pollutant sources, rather than difference in pollutant and non-pollutant.

탄소 나노튜브 혼합액으로 봉공처리된 텅스텐 카바이드 용사층의 아연 내부식성에 대한 연구 (A study on Zn corrosion resistance of WC spray coating sealed with carbon nanotube suspensions)

  • 김봉훈;이보영
    • Journal of Welding and Joining
    • /
    • 제33권1호
    • /
    • pp.49-53
    • /
    • 2015
  • An experimental study was conducted to investigate the effect of carbon nanotubes on the zinc corrosion resistance of sealing layer formed on the Tungsten Carbide spray coating. Using the nanotubes, a sealing agent in the form of solid-liquid suspensions was made and applied to the surface of spray coating. A series of experiments, consisted of three stages such as preparation of test piece, molten-pot immersion test, and evaluation of micro structure, were undertaken to demonstrate complicated interaction existing between zinc ions and sealing layer containing the nanotubes. Experimental results showed newly developed sealing layer were less susceptible to corrosion and thus coated layer was well protected even in the case of 10 days exposure. Comparison of the micro structure after molten pot test also indicated that carbon nanotubes still remained in the matrix and organized more reliable frame work constituted with boron nitride and chromium compound. It was revealed that carbon nanotubes in the sealing layer played positive role to enhance zinc corrosion resistance in the perspective of both fibrous structure and inherent chemical stability.