• Title/Summary/Keyword: Zirconia all ceramic crown

Search Result 44, Processing Time 0.018 seconds

Reestablishing the occlusal plane in full mouth rehabilitation patient, using Shilla system (전악수복환자에서 Shilla system을 이용한 교합평면 재구성 증례)

  • Yang, Min-Soo;Vang, Mong-Sook;Park, Sang-Won;Lim, Hyun-Phil;Yun, Kwi-Dug;Yang, Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.33-38
    • /
    • 2013
  • Occlusal plane is a sagittal expression of dental arch form, and it composes the shape of occlusion, which is one of the most important elements of Maxillo-oral system. In this case, vertical, horizontal coordinates of bionic-median-sagittal plane was produced in articulator, and to achieve relation of left and right position of upper, lower teeth and deficits in alveola, Shilla system was used to reconstruct occlusal plane. In this case, a 41 year-old male patient visited for fracture of 10 unit metal-ceramic fixed partial denture of upper anterior teeth and for overall treatment. Clinical, radiographical, model examination was held, full mouth rehabilitation was achieved by placing dental implant. Maxillo-oral relation was recorded using Gothic arch Tracer complex and were mounted. And for the next step, we estimated original occlusal plane using Shilla system. After analysis we produced diagnosis wax pattern. On the basis of this, radiography stent was manufactured and dental implant was placed, and temporary prosthesis was made by using diagnosis wax pattern. Cross mounting and anterior guiding table were performed in order to reproduce temporary restoration morphology and bite pattern, followed by final restoration made of all ceramic crown with zirconia coping. As stated above, appropriately esthetic and functional results can be seen in using Shilla system in diagnosis and treatment procedure of full mouth rehabilitation patient.

Effects of Surface Treatments of The Zirconium-Based Ceramic on the Bond Strength of Resin Cement (지르코니움 세라믹에서 표면 처리 방법이 레진 시멘트의 접착력에 미치는 영향)

  • Park, Kyung-Seok;Shin, Soo-Youn;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.3
    • /
    • pp.221-230
    • /
    • 2006
  • Recently, the need for esthetic results has increased the interest for all-ceramic crown prosthesis. Furthermore, the development of zirconium core via CAD/CAM system has allowed the all ceramic restorations to be applied to almost all fixed prosthesis situations. But, the increased strength has been reported to increase in proportion with the bond strength of cement, and recently, the tribochemical system which increases the bond strength through, silica coating and silanization has been introduced. The purpose of this study was to compare the $Rocatec^{TM}$ system and $CoJet^{TM}$ system with the traditional acid etching and silanization method of the irconium based ceramic. The surface character was observed via SEM(X2000), and the bond strength with the resin cement were measured. 50 In-Ceram Zirconia (Adens, Korea) discs were fabricated and embedded in resin, group 1 was treated with glass-bead blasting and cleaning, group 2 was treated with 20% HF for 10 minutes and silanized, group 3 was treated with the $Rocatec^{TM}$ system, and group 4 was treated with the $CoJet^{TM}$ system. Each group was comprised of 10 specimens. The specimens were cemented to a $3mm{\times}5mm$ resin block with Super-Bond C&B. The shear bond strength was measured with the $Instron^{(R)}$ 8871 at a crosshead speed of 0.5mm/min. The results were as follows. 1. According to SEM results, there were little difference between group 1 & group 2, but in group 3 and 4, silica coating was detected and there was increase in surface roughness. 2. The shear bond strength decreased in the order of group 3(46.28MPa), group 4(42.04MPa), group 2(31.56MPa), and group 1(27.46MPa). 3. There was significant differnce between group 1&2 and group 3&4(p<0.05). From the results above, it can be considered that the conventional method of acid etching and silane treatment cannot increase the bond strength with resin cements, and that by applying the tribochemical system of $Rocatec^{TM}$ system and $CoJet^{TM}$ system, we can achieve a stronger all ceramic restoration. Further studies on surface treatments to increase the bond strength are thought to be needed.

Comparative study in fracture strength of zirconia cores fabricated with three different CAD/CAM systems (3종의 CAD/CAM 시스템에서 지르코니아 코어의 파절 강도에 관한 비교 연구)

  • Shin, Eon-Sick;Lee, Young-Soo;Park, Won-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.22-30
    • /
    • 2008
  • Purpose: The purpose of this study is to compare three different CAD/CAM systems through the fracture strength of zirconia core and to evaluate the clinical availability of each system. Material and methods: The following three groups of 30 maxillary mesial incisor core for all-ceramics(each group 10) were fabricated as follows: group 1. $Adens^{(R)}$ CAD/CAM system, group 2. $Cerasys^{(R)}$ CAD/CAM system, group 3. 3M $Lava^{(R)}$ CAD/CAM system. All specimens were manufactured consistently thickness 0.5mm and relief $40{\mu}m$. Specimens were subjected to compressive loading on the lingual area by Z250/$SN5S^{(R)}$. Each group's mean and standard deviation were calculated and Kruskal Waillis test, Wilcoxon Rank Sum test were utilized to find out the relationship among the groups. Results: The results were as follows: 1. The mean fracture strength of $Adens^{(R)}$ system was $615.89{\pm}156.1N$, the $Cerasys^{(R)}$ system was $863.98{\pm}151.5N$, and the 3M $Lava^{(R)}$ system was $1143.1{\pm}286.6N$. 2. The fracture strength of the systems showed the significant statistical differences in order of 3M $Lava^{(R)}$ system, $Cerasys^{(R)}$ system, $Adens^{(R)}$ system. Conclusion: In this study, in spite of the differences among the groups, every group showed clinically useful results. It is necessary to study further clinical experiments on a long term basis.

Evaluation using Replica Technique on the marginal and internal fitness of zirconia cores by several CAD/CAM systems (수종의 CAD/CAM 시스템으로 제작한 지르코니아 코어에서 Replica Technique을 이용한 변연 및 내면 적합도 평가)

  • Huh, Jung-Bo;Park, Cheong-Gil;Kim, Ha-Young;Park, Chan-Kyung;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.135-142
    • /
    • 2010
  • Purpose: This study was aimed to compare the margin and internal fitness of single anterior all-ceramic crown zirconia core made by three deferent CAD/CAM systems. Material and methods: Five single zirconia cores were manufactured by three deferent CAD/CAM systems($Cerasys^{(R)}$system, KaVo $Everest^{(R)}$system, $LAVA^{TM}$system). The manufactured zirconia cores were duplicated through the use of replica technique, and a replicated sample was sectioned in the center of bucolingual and mesiodistal direction to measure the marginal and internal gap. Measurement was carried out by using measuring microscope ($AXIO^{(R)}$) and $I-Solution^{(R)}$ and analysed through the use of ANOVA. Results: As for the mean marginal fitness of the zirconia core, it was $84.74{\pm}27.57{\mu}m$, in $Cerasys^{(R)}$, $80.23{\pm}21.07{\mu}m$ in KaVo $Everest^{(R)}$ and $96.37 {\pm}11.45{\mu}m$ in $LAVA^{TM}$, and as for the mean internal gap, it was $94.11{\pm}30.07{\mu}m$ in $Cerasys^{(R)}$, $92.31{\pm}25.18{\mu}m$ in KaVo $Everest^{(R)}$, and $94.99{\pm}18.74 {\mu}m$ in $LAVA^{TM}$. There was no significant statistically deference among the total average gap of three systems. The internal gap in KaVo $Everest^{(R)}$ seemed to be smaller than $LAVA^{TM}$ (P < .05). The internal gap in the incisal area was larger in all of the three systems. Conclusion: There was no difference in marginal fitness in $Cerasys^{(R)}$, KaVo $Everest^{(R)}$ and $LAVA^{TM}$. As for the internal fitness, it was smaller in KaVo $Everest^{(R)}$ system than $LAVA^{TM}$ system. In all of the three systems, there was a larger gap in incisal area. The marginal and internal gap was within the clinically allowed range in all of the three systems.