• 제목/요약/키워드: Zircaloy Tube

검색결과 64건 처리시간 0.027초

TiN코팅한 지르칼로이-4튜브의 프레팅 특성 (Fretting Characteristics of TiN Coated Zircaloy-4 Tube)

  • 성지현;김태형;김석삼
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2000년도 제31회 춘계학술대회
    • /
    • pp.269-275
    • /
    • 2000
  • The fretting wear characteristics of TiN coated Zircaloy-4 tube were investigated experimentally The fretting wear experiment was performed using TiN coated Zircaloy-4 tube as the fuel rod cladding material and uncoated Zircaloy-4 tube as one of grids. TiN coating is probably one of the most frequently and successfully used PVD coatings for the mitigation of fretting wear. In this study, TiN coating by PVD was employed for improvement of Zircaloy-4 tube fretting characteristics. The fretting tester was designed and manufactured for this experiment. TiN coated Zircaloy-4 tube was used as the moving specimen, uncoated ZircaBoy-4 tube as the stationary one. The number of cycles, slip amplitude and normal load were selected as main factors of fretting wear. The results of this research showed that the wear volume of TiN coated Zircaloy-4 tube increased as number of cycles, normal load and slip amplitude increase but the quantity of volume was lower than the case of uncoated Zircaloy-4 tube pairs.

  • PDF

경수 및 공기중에서의 지르칼로이-4 튜브의 프레팅 마멸특성 비교 (A Comparison of Fretting Wear Characteristics of Zircaloy-4 Tube in Light Water and in Air)

  • 조광희;김태형;김석삼
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1999년도 제29회 춘계학술대회
    • /
    • pp.303-309
    • /
    • 1999
  • The fretting wear behaviour of Zircaloy-4 tube used as the fuel rod cladding in PWR nuclear power plants has been investigated at the different test environment, in light water and in air as a function of slip amplitude, normal load, test duration and frequency. Zircaloy-4 tubes were used for both of oscillating and stationary specimens. A fretting wear tester was designed to be suitable for this fretting test. The wear volume and specific wear rate of Zircaloy-4 tube in water were greater than those in air under various slip amplitude. It was found that delaminate debris and surface cracks were observed at low slip amplitude and high load in water Experimental results showed that the light water accelerated the wear of Zircaloy-4 tube at low slip amplitude in fretting.

  • PDF

지르칼로이-4 튜브 프레팅 마멸 특성의 환경 의존성과 마멸기구 (Comparison of Fretting Wear Characteristics of Zircaloy-4 Tube in Light Water and in Air)

  • 조광희;김석삼
    • Tribology and Lubricants
    • /
    • 제15권1호
    • /
    • pp.83-89
    • /
    • 1999
  • The fretting wear behaviour of Zircaloy-4 tube used as the fuel rod cladding in PWR nuclear power plants has been investigated at the different test environment, in light water and in air as a function of slip amplitude, normal load, test duration and frequency. Zircaloy-4 tubes were used for both of oscillating and stationary specimens. A fretting wear tester was designed to be suitable for this fretting test. The wear volume and specific wear rate of Zircaloy-4 tube in water was greater than those in air under various slip amplitude. Delaminates and surface cracks were observed at low slip amplitude and high load of fretting test in water, but the traces of adhesion and plowing were observed at and above 200 Um. The water accelerates the wear of Zircaloy-4 tube at lower slip amplitude in fretting.

공기중에서 인코넬-지르칼로이 접촉의 프레팅 마멸특성 (Fretting Wear Characteristics of Inconel-Zircaloy Contact in Air)

  • 노규철;김석삼
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1999년도 제29회 춘계학술대회
    • /
    • pp.310-316
    • /
    • 1999
  • The fretting wear characteristics of the contact between Zircaloy-4 tube and Inconel 600 tube have investigated. Zircaloy-4 is used for fuel rod in nuclear reactor and Inconel 600 is used for tube In steam generator of nuclear power plant. A fretting wear tester was designed to be suitable for this fretting test. In this study, the number of cycles, slip amplitude and normal load were selected as main factors of fretting wear. This study shows that the wear scar length of Zircaloy-4 and Inconel 600 increases as number of cycles, normal load and slip amplitude increase and the wear scar length of Zircaloy-4 is more longer than that of Inconel 600 due to the surface hardness.

  • PDF

경수중에서 지르칼로이-4 튜브의 프레팅 마멸특성 (Fretting Wear Characteristics of Zircaloy-4 Tube in Light Water)

  • 조광희;노규철;김석삼;조성재
    • Tribology and Lubricants
    • /
    • 제14권4호
    • /
    • pp.88-94
    • /
    • 1998
  • The fretting wear characteristics of Zircaloy-4 tube in light water were investigated experimentally. A fretting wear tester was designed to be suitable for this fretting test. This study was focused on the effects due to the combination of normal load, slip amplitude and number of cycles as the main factors of fretting. The results of this study showed that the wear volume increased abruptly at slip amplitude above 100 ${\mu}{\textrm}{m}$, which is defined as critical slip amplitude of Zircaloy-4 tube in light water, and that under 160 ${\mu}{\textrm}{m}$ the wear volume decreased as load increased at the same slip amplitude.

경수중에서 지르칼로이-4 튜브의 프레팅 마멸특성 (Fretting Wear Characteristics of Zircaloy-4 Tube in Light Water)

  • 조광희;노규철;김석삼;조성재
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1998년도 제27회 춘계학술대회
    • /
    • pp.55-63
    • /
    • 1998
  • The fretting wear characteristics of Zircaloy-4 tube in light water were investigated experimentally. A fretting wear tester was designed to be suitable for this fretting test. This study was focused on the effects due to the combination of normal load, slip amplitude and number of cycles as the main factors of fretting. The results of this study showed that the wear volume increased abruptly at slip amplitude above 100$\mu$m, which is defined as critical slip amplitude of Zircaloy-4 tube in light water, and that under 160$\mu$m the wear volume decreased as load increased at the same slip amplitude.

  • PDF

노외 실험을 통한 가압경수형 핵연료 피복재의 항복거동연구 (Out-of-Pile Test for Yielding Behavior of PWR Fuel Cladding Material)

  • Yi, Jae-Kyung;Lee, Byong-Whi
    • Nuclear Engineering and Technology
    • /
    • 제19권1호
    • /
    • pp.22-33
    • /
    • 1987
  • 원자력 발전소에 있어서 정상가동 상태나 이상동작시에 핵연료 피복관의 건전성 확보와 연관하여 피복재의 항복거동은 중요한 문제이다. 급격한 출력상승 상황에서 이산화 우라늄 소결체와 피복관 사이의 노내 조사거동의 차이는 소결체와 피복관 사이에 Contact Pressure를 야기 시킨다. 만일 이 Contact Pressure가 Zircaloy 피복관의 Yield Pressure에 도달하면 피복관에는 영구변형이 일어난다. 이 변형은 원자로의 출력이 정상상태로 회복되더라도 존재하므로 소결체와 피복관 사이의 Gap을 증대시킨다. 이러한 상황을 묘사하기 위해 본 논문에서는 구리 Mandrel과 Zircaloy사이의 열팽창 차이를 이용하는 Mandrel 팽창 실험을 실행했다. 실험 결과 측정된 Zircaloy 피복관의 외경 팽창치와 본 논문에서 유도된 수학적 관계식들을 이용하여 온도에 따른 Zircaloy 피복관의 내부항복압력과 항복응력, 피복재의 항복에 따른 핵연료 소결체와 피복관 사이의 Gap 증대를 구하고, 항복 거동에 따른 온도의 영향을 보기 위해 항복과정의 활성화 에너지를 구했다. 본 실험과 분석에서 얻어진 이들 결과들은 다른 실험 결과들과 상당히 일치하였으며, 이것으로 볼 때 본 논문에서 유도된 관계식들과 Mandrel 팽창 실험이 Zircaloy 피복관의 항복거동과 Gap Expansion 측정에 신뢰성이 있음을 알 수 있었다.

  • PDF

Zircaloy-4 핵연료봉 레이저 용접부의 고온부식 특성 연구 (Corrosion Properties of Zircaloy-4 Cladding Tube having a Laser Welding Part in Elevated Temperature)

  • 김동균;박진석;김상태;양명승;이정원;김수성;정용환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.256-261
    • /
    • 2001
  • Corrosion and tensile properties of zircaloy-4 cladding tube having a laser welding part in elevated temperature are studied to present the criterion of quality evaluation in nuclear reactor and to found the scientific basis of SCC, with laser welding method using by coupling up cladding tube to end cap. In the result of tensile test($400^{\circ}C$), the fracture is not happened in the welding part but base metal and the result of corrosion test($400^{\circ}C$ 1500psi steam), corrosion rate of the molten zone and PMZ is a little higher than the other zone.

  • PDF

지르칼로이-4 피복관을 이용한 레이저용접성 연구 (A Study on the Laser Beam Weldability Using Zircaloy-4 Cladding Tube)

  • 박진석;김동균;김상태;양명승;김수성;이정원
    • Journal of Welding and Joining
    • /
    • 제20권6호
    • /
    • pp.72-72
    • /
    • 2002
  • Corrosion and tensile properties of zircaloy-4 cladding tube having a laser welding part in elevated temperature are studied to present the criterion of quality evaluation in nuclear reactor and find the scientific basis of SCC, with laser welding method using by coupling up cladding tube to end cap. In the result of tensile test(400℃), the fracture is not happened in the welding part but base metal and the result of corrosion test(400℃ 1500psi steam), corrosion rate of the molten zone and PMZ is a little higher than the other zone.

지르칼로이-4 피복관을 이용한 레이저용접성 연구 (A Study on the Laser Beam Weldability Using Zircaloy-4 Cladding Tube)

  • 박진석;김동균;김상태;양명승;김수성;이정원
    • Journal of Welding and Joining
    • /
    • 제20권6호
    • /
    • pp.796-801
    • /
    • 2002
  • Corrosion and tensile properties of zircaloy-4 cladding tube having a laser welding part in elevated temperature are studied to present the criterion of quality evaluation in nuclear reactor and find the scientific basis of SCC, with laser welding method using by coupling up cladding tube to end cap. In the result of tensile test($400^{\circ}C$), the fracture is not happened in the welding part but base metal and the result of corrosion test($400^{\circ}C$ 1500psi steam), corrosion rate of the molten zone and PMZ is a little higher than the other zone.