• 제목/요약/키워드: Zero-Phase Filter

검색결과 98건 처리시간 0.025초

Wind Power Grid Integration of an IPMSG using a Diode Rectifier and a Simple MPPT Control for Grid-Side Inverters

  • Ahmed, Tarek;Nishida, Katsumi;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제10권5호
    • /
    • pp.548-554
    • /
    • 2010
  • In this paper, a 1.5 kW Interior Permanent Magnet Synchronous Generator (IPMSG) with a power conditioner for the grid integration of a variable-speed wind turbine is developed. The power-conditioning system consists of a series-type 12-pulse diode rectifier powered by a phase shifting transformer and then cascaded to a PWM voltage source inverter. The PWM inverter is utilized to supply sinusoidal currents to the utility line by controlling the active and reactive current components in the q-d rotating reference frame. While the q-axis active current of the PWM inverter is regulated to follow an optimized active current reference so as to track the maximum power of the wind turbine. The d-axis reactive current can be adjusted to control the reactive power and voltage. In order to track the maximum power of the wind turbine, the optimal active current reference is determined by using a simple MPPT algorithm which requires only three sensors. Moreover, the phase angle of the utility voltage is detected using a simple electronic circuit consisting of both a zero-crossing voltage detecting circuit and a counter circuit employed with a crystal oscillator. At the generator terminals, a passive filter is designed not only to decrease the harmonic voltages and currents observed at the terminals of the IPMSG but also to improve the generator efficiency. The laboratory results indicate that the losses in the IPMSG can be effectively reduced by setting a passive filter at the generator terminals.

2진 정합필터를 이용한 웨이브릿 편이변조 시스템 (Wavelet Shift Keying System Using a Binary Matching Filter)

  • 오형진;정태일;이태오
    • 한국정보통신학회논문지
    • /
    • 제12권11호
    • /
    • pp.1933-1938
    • /
    • 2008
  • 기존의 대표적인 디지털 통신방식으로 주파수 편이 변조(FSK: Frequency Shift Keying), 위상 편이 변조(PSK-Phase Shift Keying), 진폭 편이 변조(ASK: Amplitude Shift Keying) 방식들이 있다. 본 논문에서는 디지털 통신에서 2진 정합필터를 이용하여 웨이브릿 편이변조 신호를 복원하는 알고리즘을 제안한다. 웨이브릿 편이 변조 시스템은 스케일링 함수(scaling function)와 웨이브릿(wavelet)을 이용한다. 스케일링 함수를 1로, 웨이브릿 함수를 0으로 할당하여 2진 데이터를 변조한다. 기존의 웨이브릿 편이 변조시스템에서는 복원을 위해 후처리가 필요하였다. 본 논문에서는 웨이브릿 편이 변조 수신기에서 2진 정합필터를 이용하여 웨이브릿 편이 변조 신호를 복원한다. 그래서 별도의 후처리 과정 없이 복원이 가능하였다. 모의실험 결과 제안한 알고리즘이 타당함을 확인하였다.

UFIR 필터 Ladder 알고리즘 이용 GPS Holdover 성능 추정 (Estimation of GPS Holdover Performance with Ladder Algorithm Used for an UFIR Filter)

  • 이영규;양성훈;이창복;허문범
    • 제어로봇시스템학회논문지
    • /
    • 제21권7호
    • /
    • pp.669-676
    • /
    • 2015
  • In this paper, we described the simulation results of the phase offset performance of a clock in holdover mode which was normally operated in GPS Disciplined Oscillator (GPSDO). In the TIE model, we included the time error term caused by environmental temperature variation because one of the most important parameters of clock phase error is the frequency offset and drift caused by the variation of temperature. For the simulation, we employed Maximum Time Interval Error (MTIE) for the performance evaluation when the frequency offset and drift are estimated by using an Unbiased Finite Impulse Response (UFIR) filter with ladder algorithm. We assumed that the noise in the GPS measurement is white Gaussian with zero mean and 1 ns standard deviation, and temperature linearly varies with a slope of $1{^{\circ}C}$ per hour. From the simulation results, the followings were observed. First, with the estimation error of temperature of less than 3 % and the temperature compensation period of less than 900 seconds, the requirement of CDMA2000 phase synchronization under 10 us could be achieved for more than 40,000 seconds holdover time if we employ an OCXO (Oven Controlled Crystal Oscillator) clock. Second, in order to achieve the requirement of LTE-TDD under 1.5 us for more than 10,000 seconds holdover time, below 3 % estimation error and 500 seconds should be retained if a Rubidium clock is adopted.

영상분 3고조파 전압을 이용한 속도센서없는 유도전동기 벡터제어 시스템의 파라미터 변동 보상 (A Compensation Method of Parameter Variations for the Speed-Sensorless Vector Control System of Induction Motors using Zero Sequence Third Harmonic Voltages)

  • 최정수;김진수;김영석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권2호
    • /
    • pp.75-82
    • /
    • 1999
  • A compensation method of the motor parameters using zero sequence third harmonic voltage is presented for the speed sensorless vector control of the induction motor considering saturation of the flux. Generally, the air-gap flux of the saturated induction motor contains the space harmonic components rotating with the synchronous frequency of the motor. Because the EMF of the saturated induction motor contains the zero sequence harmonic voltages at the neutral point of the motor, those harmonic voltages can be used as a saturation index. In this work, the rotor flux observer is firstly designed for the speed sensorless vector control of induction motor. And a novel measurement method of the space harmonic voltage and a compensation method of th LPF(Low Pass Filter) are proposed. For compensating the non-linear variations of the magnetizing inductance depending on the saturation level of the motor, the dominant third harmonic voltage of the motor is used as a saturation function of the air-gap flux. And the variation of the stator resistance owing to the motor temperature can also be measured with the phase angle between the impressed voltage vector and the zero sequence voltage. The validity of the proposed parameter compensation scheme in the speed sensorless vector control using rotor flux observer is verified by the result of the simulations and the experiments.

  • PDF

New Strategy for Eliminating Zero-sequence Circulating Current between Parallel Operating Three-level NPC Voltage Source Inverters

  • Li, Kai;Dong, Zhenhua;Wang, Xiaodong;Peng, Chao;Deng, Fujin;Guerrero, Josep;Vasquez, Juan
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.70-80
    • /
    • 2018
  • A novel strategy based on a zero common mode voltage pulse-width modulation (ZCMV-PWM) technique and zero-sequence circulating current (ZSCC) feedback control is proposed in this study to eliminate ZSCCs between three-level neutral point clamped (NPC) voltage source inverters, with common AC and DC buses, that are operating in parallel. First, an equivalent model of ZSCC in a three-phase three-level NPC inverter paralleled system is developed. Second, on the basis of the analysis of the excitation source of ZSCCs, i.e., the difference in common mode voltages (CMVs) between paralleled inverters, the ZCMV-PWM method is presented to reduce CMVs, and a simple electric circuit is adopted to control ZSCCs and neutral point potential. Finally, simulation and experiment are conducted to illustrate effectiveness of the proposed strategy. Results show that ZSCCs between paralleled inverters can be eliminated effectively under steady and dynamic states. Moreover, the proposed strategy exhibits the advantage of not requiring carrier synchronization. It can be utilized in inverters with different types of filter.

An Optimal Approach to Rotational Vibration Suppression using Disturbance Observer in Disk Drive Systems

  • Park, Sung-Won;Kim, Nam-Guk;Chu, Sang-Hoon;Kang, Chang-Ik;Lee, Ho-Seong
    • 정보저장시스템학회논문집
    • /
    • 제3권1호
    • /
    • pp.5-12
    • /
    • 2007
  • This paper investigates the design of disturbance observer for rotational vibration suppression in disk drive systems. The design aims to provide an optimal controller which satisfies both vibration performance and robust stability. It consists of an inversion method, a special filter, and optimization scheme. Firstly a new inversion method is introduced, which provides more accurate inversion compared to conventional zero phase error method. The inversion is to deal with unstable zeros in the plant model. Secondly a special filter for disturbance selection is given, which features adjustable gain and band pass characteristics so that it enables flexible shaping of the loop considering the trade-off between performance and stability margins. And finally the parameters of disturbance observer are optimized in conjunction with external disturbance model. Simulation and experiment on commercial hard disk drives confirm that the design is very effective to such disturbance which is hard to be handled by conventional approach.

  • PDF

바이폴라 델타 신호에 대한 GMSK 변조 (The GMSK Modulation for Bipolar Delta Signal)

  • 방승철;이우상
    • 한국통신학회논문지
    • /
    • 제38B권7호
    • /
    • pp.581-588
    • /
    • 2013
  • 기본적으로 GMSK는 NRZ 펄스열을 가우시안 저역 통과 필터로 전 처리한 후에 GMSK 신호를 생성하지만, 본 논문에서는 델타 펄스열에 대한 GMSK 변조 시스템을 제안하였다. 제시된 시스템은 바이폴라 델타 펄스로 가우시안 펄스를 발생시키는 가우시안 펄스 생성기, $+T_b/2$$-T_b/2$ 사이의 차분기, 그리고 주파수변조 함수를 위한 정합 필터로 구성한다. 기본적인 GMSK 변조와의 비교를 통해 스펙트럼은 40[dB] 감쇠 대역폭에서 약 35[%] 협소하며, 스펙트럼의 중심은 더 낮고, 제로 크로싱 성질이 있는 것으로 나타났다.

스위치 캐패시터형 공진 DC-링크를 사용한 3상 전류형 소프트 스위칭 PWM 컨버터 (Three-phase current-fed soft-switching type resonant DC-link snubber converter with switched capacitor)

  • 김주용;서기영;이현우;문상필;김영문
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.387-390
    • /
    • 2005
  • A This paper presents a novel three-phase current-fed Pulse Width Modulation converter with switched- capacitor type resonant DC link commutation circuit operating PWM pattern strategy under a design consideration of low-pass filter, which can operate on the basis of the principle of zero current soft-switching commutation. In the first place, the steady-state operating principle of this converter with a new resonant DC link snubber circuit is described in connection with the equivalent operation circuit, together with the practical design procedure of the switched-capacitor type resonant DC link circuit is discussed from a theoretical viewpoint on the basis of a design example for high-power applications. The actively delayed time correction method to compensate distorted currents due to a relatively long resonant commutation time is newly implemented in the open loop control scheme so as to acquire the new optimum PWM pattern. Finally, the experiment or set-up in laboratory system or this converter is concretely demonstrated herein to confirm a zero current soft-switching commutation of this converter. The comparative evaluations between current-fed hard switching PWM and soft-switching PWM converters are carried out from a viewpoint of their PWM converter characteristics.

  • PDF

입력 전류의 측정이 필요없는 Boost 컨버터의 역률 보정에 관한 연구 (A Study On The Power Factor Correction Of The Boost Converter Without The Input Current Measurement)

  • 조상준;이광원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.376-378
    • /
    • 1996
  • This paper presents a new PFC control method which replaces a fast line current measurement with a filtered load current measurement. Using the power balance relation between the input and the output of the boost converter. the input current can be described as the function of load current. Thus the PWM signal which effects the switching control of the boost converter is generated using the PFC input voltage, the PFC output voltage and the load current as input variables. By using a filter between the bridge rectifier and a dc-to-dc converter, the input voltage of the dc-to-dc converter is forced to always maintain above zero volt. Then the input current traces a sinewave in phase. The proposed scheme accomplishes a very high power factor and a low harmonic distortion of the line current. The validity of this scheme is demonstrated through simulation.

  • PDF

마이크로 컴퓨터를 이용한 휴대용 부정맥 모니터의 개발(I)-하드웨어 설계를 중심으로- (Development of Portable Arrhythmia Moniter Using Microcomputer(I))

  • 이명호;안재봉
    • 대한의용생체공학회:의공학회지
    • /
    • 제7권2호
    • /
    • pp.169-182
    • /
    • 1986
  • Pulsed ultrasonic Doppler system is a useful diagnostic instrument to measure blood-flow-velocity, velocity profile, and volume-blood-flow. This system is more powerful compare with 2-dimensional B-scan tissue image. A system has been deve- loped and ii being evaluated using TMS 32010 DSP. We use this DSP for the purpose of real-time spectrum analyzer to obtain spectrogram in singlegate pulsed Doppler system and for the serial comb filter to cancel clutter and zero crossing counter to estimate Doppler mean frequency in multigate pulsed Doppler system. The Doppler shift of the backscattered signals is sensed in a phase detector. This Doppler signal corresponds to the mean velocity over a some region in space defined by the ultrasonic beam dimensions, transmitted pulse duration, and transducer ban(iwidth. Multi- gate pulsed Doppler system enable the transcutaneous and simultaneous assessment of the velocities in a number of adjacent sample volumes as a continuous function of time. A multigate pulsed Doppler system processing the information originating from presented.

  • PDF