• Title/Summary/Keyword: Zero Impedance

Search Result 131, Processing Time 0.029 seconds

A Novel Epsilon Near Zero Tunneling Circuit Using Double-Ridge Rectangular Waveguide

  • Kim, Byung-Mun;Son, Hyeok-Woo;Hong, Jae-Pyo;Cho, Young-Ki
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.1
    • /
    • pp.36-42
    • /
    • 2014
  • In this paper, an epsilon near zero (ENZ) tunneling circuit using a double-ridge rectangular waveguide (RWG) is proposed for the miniaturization of a waveguide component. The proposed ENZ channel and is located in the middle of the input-output RWG (IORWG). The ratio of the height to the width of the channel waveguide is very small compared to the IORWG. By properly adjusting the ridge dimensions, the tunneling frequency of the proposed ENZ channel can be lowered to near the cut-off frequency of the IORWG. For the proposed ENZ tunneling circuit, the approach adopted for extracting the effective permittivity, effective permeability;normalized effective wave impedance, and propagation constant from the simulated scattering parameters was explained. The extracted parameters verified that the proposed channel is an ENZ channel and electromagnetic energy is tunneling through the channel. Simulation and measurement results of the fabricated ENZ channel structure agreed.

Design and Fabrication of Wide-band Ferrite Absorber Used in Anechoic Chamber

  • Kim, Sung-Soo;Park, Ik-Kown
    • Journal of Magnetics
    • /
    • v.2 no.1
    • /
    • pp.25-27
    • /
    • 1997
  • Ferrite tile absorber is of great concern for the application to anechoic chambers due to the growing demand of EMI or EMC measurements. This paper investigates the magnetic, dielectric and microwave absorbing properties of a Ni-An ferrite for the purpose. A design chart was constructed with the solutions of impedance-matching equation in the radio frequencies (30 MHz - 1 GHz). The material parameters for zero-reflection are predicted from the chart. The magnetic and dielectric properties of sintered Ni-Zn ferrite is found to be well suited for this requirements. A superior microwave absorbing properties (frequency band and absorber thickness) of the samples are demonstrated.

  • PDF

Development of the Patient Monitor Using Microprocessor (마이크로 프로세서에 의한 환자감시장치의 개발)

  • 김남현;유선국
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.309-316
    • /
    • 1989
  • In this paper, the patient monitor consisting of amplifier, scan converter, A/D converter, CRT amplifier, and micro-controller part was developed. This patient monitor measures the patient's 4 states in the hospital such as electro-cardiography, respiration, blood pressure, and temperature. The control and processing methods based on micro-processor employ the flexibility, extensibility and economy over other conventional system. The followings are incorporated in this system. First, record the heart rate trends for 1 and 4 hours respectively. Second, measures the respiration by impedance pneumography. Third, measures the blood pressure with auto-zero balance. Fourth, linesrize the temperatures by bridge method.

  • PDF

Analysis of the TEM Cells Having arbitrary Rectangular Septum by Using Moment Method (모멘트법을 이용한 임의의 구형 내부도체를 갖는 TEM Cell의 특성 분석)

  • 윤재훈;최익권
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.15 no.11
    • /
    • pp.898-908
    • /
    • 1990
  • This paper applies the moment method to analyze the transverse electromagnetic(TEM) cell with an inner conductor (septum) of arbitrary rectangular shape and location by employing quast static approximation. The EM field and the characteristic impedance so obtained are shown to be in good agreement with the available data from the previously published papers about the typical TEM cell structure with center septum of zero thickness.

  • PDF

Two-Layered Microwave Absorber of Ferrite and Carbon Fiber Composite Substrate

  • Han-Shin Cho;Sung-Soo Kim
    • Journal of Magnetics
    • /
    • v.3 no.2
    • /
    • pp.64-67
    • /
    • 1998
  • Microwave absorbing properties of ferrite-epoxy composite (absorbing layer) attached on the carbon fiber polymer composite (reflective substrate) are analyzed on the basis of wave propagation theory. A modified equation for wave-impedance-matching at the front surface of absorbing layer including the effect of electrical properties of the quasi-conducting substrate is proposed. Based on this analysis, the frequency and layer dimension that produce zero-reflection can be estimated from the intrinsic material properties of the obsorbing layer and the substrate. It is demonstrated that the microwave reflectivity of carbon fiber composite has a strong influence on the microwave absorbance of front magnetic layer.

  • PDF

A Study on Force-Reflecting Interface using Ultrasonic Motros (초음파모터를 이용한 역감장치에 관한 연구)

  • 강원찬;김대현;김영동
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.123-128
    • /
    • 1998
  • This paper describes the evaluation of a force-reflecting interface with ultrasonic motors(USMs). The force-reflecting interface allows a human to feel object within virtual environment. To effectively display the mechanical impedance of the human hand we need a haptic device with specific characteristics, such as low inertia, almost zero friction and very high stiffness. USMs have attracted considerable attention as the actuator satisfied these conditions. USMs combine features such as high driving torque at low rotational speed, high holding torque and fast response therefore we studied two degree of freedom force-reflecting haptic system.

  • PDF

A Signal Anti-reduction System for Power Line Communication

  • Ko Jong-Sun;Kim Hyun-Sik;Hong Soon-Chan
    • Journal of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.256-260
    • /
    • 2004
  • A new communication system is suggested using a single-phase full-bridge inverter with high efficiency ferrite core for power line communication (PLC). The conventional system has a decreasing signal voltage problem due to internal resistance. The proposed system has almost zero internal impedance and replaces a linear amplifier.

Properties Investigation of Corrosion Monitoring for Pure Mg Thin Films under Wet-Dry Cyclic Conditions by Using Electrochemical Impedance Spectroscopy Method (건습환경중 순 Mg박막의 EIS부식 모니터링 특성 관찰)

  • Bae, I.Y.;Lee, K.H.;Kim, K.J.;Moon, K.M.;Lee, M.H.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.192-193
    • /
    • 2005
  • Magnesium thin films were prepared on cold-rolled steel substrates by RF(Radio Frequency) magnetron sputtering technique.$^{1)}$ The crystal orientation and monitoring of the deposited films were investigated by using XRD(X-ray Diffraction) and EIS(Electrochemical Impedance Spectroscopy), respectively. The corrosion rates of Mg thin films deposited with different argon gas pressure and substrate bias voltage were monitored by AC impedance method under a cyclic wet-dry condition, which was conducted by exposure to alternate conditions of 1h immersion in 3%NaCl solution and 5h drying at 60% RH and 25$^{\circ}C$. The result of corrosion rate of Mg thin films deposited at various Ar gas pressures and substrate bias voltage under wet-dry cyclic exposure in chloride-containing solutions was showed the following conclusions. At the region I during the onset of the wet cycle, corrosion rate showed relatively low value. The increase in the Corrosion rate of region II is due to the increase in the chloride concentration. Corrosion rate of region III during the onset of the cycle zero and salt crystals remain on the metal surface.$^{2)}$

  • PDF

Characteristic Analysis of Voltage Sags Due to Faulted Distribution Lines (배전선로 고장에 의한 Voltage Sag의 특성 해석)

  • ;Madhat M. Morcos
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.1
    • /
    • pp.76-84
    • /
    • 2002
  • Voltage sags caused by line faults in transmission and distribution lines have become one of the most important power quality problems facing industrial customers and utilities. Voltage sags are normally described by characteristics of both magnitude and duration, but phase angle shifts should be taken account in identifying sag phenomena and finding their solutions. In this paper, voltage sags due to line faults such as three phase-to-ground, single line-to-ground, and line-to-line faults are characterized by using symmetrical component analysis, for fault impedance variations. Voltage sags and their effect on the magnitude and phase angle are examined. Balanced sags of three phase-to-ground faults show that voltages and currents are changed with equivalent levels to all phases and the zero sequence components become zero. However, for unbalanced faults such as single line-to-ground and line-to-line faults, voltage sags give different magnitude variations and phase angle shifts for each phase. In order to verify the analyzed results, some simulations based on power circuit models are also discussed.

Stopband-Extended and Size-Miniaturized Low-Pass Filter with Three Transmission Zeros

  • Li, Lin;Bao, Jia;Du, Jing-Jing;Wang, Yaming
    • ETRI Journal
    • /
    • v.36 no.2
    • /
    • pp.286-292
    • /
    • 2014
  • This paper presents a compact structure composed of an upper high-impedance transmission line, a middle extended parallel coupled line, and a pair of inter-coupled symmetrical stepped impedance stubs. Detailed investigation into this structure based on an equivalent circuit analysis reveals that this proposed structure exhibits a quasi-elliptic low-pass filtering response with three transmission zeros. Moreover, the positions of the three transmission zeros can be tuned and reallocated flexibly by choosing the proper circuit parameters. Finally, the design concept is validated through the design, fabrication, and measurement of two exemplary low-pass filters (LPFs) with one single unit and two cascaded asymmetric units. The measured results agree well with the simulated results. In addition, in the range of $1.42f_c$ to $7.03f_c$, the fabricated quasi-elliptic LPFs experimentally demonstrate a very wide upper-stopband of 20 dB using a compact size of only $0.0089{\lambda}_g{^2}$, where ${\lambda}_g$ is the guided wavelength of a $50{\Omega}$ transmission line at the central frequency.