• 제목/요약/키워드: Zero Energy Solar House

검색결과 46건 처리시간 0.024초

지열히트펌프의 작동시간 경과에 따른 COP 변화에 대한 연구 (Study on COP Variations with the duration of Ground Source Heat Pump Systems Operation)

  • 이용규;백남춘;윤응상
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.198.2-198.2
    • /
    • 2010
  • In this study, the COP variation with the duration of Ground Source Heat Pump (GSHP) systems operation was analyzed by experiment. This experimental facility was installed in residential house as a back-up device of solar thermal heating system. The capacity of heat pump is 2.5 kW with a vertical bore hole of 150m depth. The COP of GSHP is varied, depending on the ground temperature which is used as a heat source. The ground heat source temperature influencing heating COP is the soil or rock temperature which adjoin with geo-source heat exchanger. This temperature is decreased rapidly according to the operation duration of heat pump. As a result, COP of GSHP is decreased to 3 in one hour of continuous operation time.

  • PDF

수막재배 단동비닐하우스의 태양열 축열이용 효과분석 (Analysis of Solar Energy Storage Using Effectiveness on Single Span Plastic Greenhouse with Water Curtain System)

  • 이성현;유영선;문종필;윤남규;이수장;김경원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.200.2-200.2
    • /
    • 2010
  • This study was carried out in order to reduce the amount of underground water which is used in the water curtain system for retaining heat. To proceed to the research, two plastic green houses of water curtain system were installed. One was equipped of internal small tunnel for keeping warm air in the interior of the house. Then the internal small tunnel for keeping warm air was fitted with PVC duct of 50cm in diameter filled with subsurface water. Storing surplus solar energy in the water filled in PVC duct was the method used to this house. Another was installed with FCU in the middle of the house, and was fitted a circulation motor in water tank for heat storage which was operated from 10 a.m. to 4 p.m. in order to interchange heat with FCU. The latter was installed with four FCUs which has a capacity of 8000kcal per hour. Consequently about 5 degrees celsius could be maintained in the interior of the internal small tunnel for keeping warm air with the external temperature of more than minus 5 degrees celsius. It appeared that the alteration of an internal temperature of the house was flexible depending on the sunlight during daytime. It happened that to prevent the water from freezing, mixing antifreezing liquid in the flowing water of FCU or changing the operating method of FCU was a suitable measure. Also, in order to use the surplus solar thermal energy on plastic green house of water curtain system efficiently, storing the surplus heat during daytime simultaneously finding a method of using water curtain systematic underground water happened to be important. As a result of this research, when the house's interior temperature is below zero the operation of FCU appeared to be impossible. Therefore when supposed that the amount of water used in the house is 150~200ton for stable operation of FCU, using the system mentioned in the above research happened to be appropriate of reducing the amount of subsurface water from 80% to 100% when maintaining the interior of internal small tunnel's temperature for keeping warm air of 5 degrees celsius at the extreme temperature of minus 5 degrees celsius.

  • PDF

Lessons Learned during the Early Phases of a Modular Project: A Case Study of UNLV's Solar Decathlon 2020 Project

  • Choi, Jin Ouk;Lee, Seungtaek;Weber, Eric
    • 국제학술발표논문집
    • /
    • The 9th International Conference on Construction Engineering and Project Management
    • /
    • pp.543-550
    • /
    • 2022
  • The U.S. Department of Energy conducts the Solar Decathlon competition as a student-based achievement that encourages sustainable design with energy efficiency and solar energy technologies. In the 2020 competition, the University of Nevada, Las Vegas (UNLV) team designed, fabricated, and constructed a net-zero modular house that applies innovative and highly efficient building technologies. This paper focused on the lessons learned during the early phases of this ongoing modular project. The research methodology included obtaining feedback from key project participants using a well-structured questionnaire. The results showed that the major items/challenges in the project's planning phase included selecting the modular size, planning the construction system, planning the materials and procurement, estimating costs and duration, selecting a fabricator, collaboration and communication, safety, and planning module transportation. These findings will help modular practitioners and future Solar Decathlon competition participants better understand how and what factors they should consider most during the early phases through the lessons learned.

  • PDF

2중 단동비닐하우스의 태양열 축열이용 효과 (Solar Energy Storage Effectiveness on Double Layered Single Span Plastic Greenhouse)

  • 이성현;유영선;문종필;윤남규;권진경;이수장;김경원
    • Journal of Biosystems Engineering
    • /
    • 제36권3호
    • /
    • pp.217-222
    • /
    • 2011
  • This study was carried out in order to reduce the amount of underground water which is used in the double layered single span plastic greenhouse for retaining heat. For this research, two plastic green houses of the double layered single span plastic greenhouse were installed. There was equipped of internal small tunnel for keeping warm air in the interior of the house. Then the internal small tunnel for keeping warm air was fitted with PVC duct of 50 cm in diameter filled with subsurface water. The surplus solar energy in the greenhouse was stored in the water in the PVC duct. Four FCUs (Fan Coil Unit), which has the capacity of 8,000 kcal per hour, were installed in the middle of the house, and a circulation motor in heat storage water tank was operated from 10:30 a.m. to 16:00 p.m. in order to circulate water between the water tank and the FCUs. Consequently about 5 degrees celsius could be maintained in the interior of the internal small tunnel for keeping warm air with the external temperature of lower than minus 5 degrees celsius. It appeared that the alteration of an internal temperature of the house was flexible depending on the sunlight during daytime. To prevent the water freezing, mixing antifreezing liquid in the water or operating FCU continuously was needed. Also, in order to use the surplus solar thermal energy on plastic green house of water curtain system efficiently, storing the surplus heat during daytime simultaneously finding a method of using water curtain systematic underground water happened to be important. As a result of this research, when the house's interior temperature is below zero the operation of FCU appeared to be impossible. Considering the amount of water used in the house with water-curtain-heating system is 150~200 ton per day, using the system mentioned in this research showed that reducing the underground water more than 80% in order to maintain the internal temperature as the level of 5 degree celsius at the extreme temperature of minus 5 degrees celsius.

폐자원을 재활용한 일체형 경량 콘크리트 태양광패널 제작에 관한 기초적 연구반복 (A basic study on the production of an integrated lightweight concrete solar panel using recycled waste resources)

  • 이국재
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.168-169
    • /
    • 2022
  • The continuous development of science and technology since the Industrial Revolution and the development of human civilization are based on the use of fossil fuels. However, the use of fossil fuels is increasing the greenhouse gas, the main cause of global warming, and global warming is an extreme climate anomaly that is rapidly increasing human and material damage. Therefore, efforts are being made worldwide to return greenhouse gases to pre-industrial levels. In Korea, 2050 carbon neutrality has been set as a major policy and efforts are being made to curb carbon emissions in the overall industry. Carbon emission suppression is based on the minimization of fossil fuel use, and research and development are underway on building a zero-emission house that minimizes the energy used in buildings in the construction field. Therefore, in this study, as part of the zero-emissions water system construction, waste resources generated at industrial sites were utilized and an integrated lightweight concrete solar panel grafted with a concrete lightweight panel and solar panel was manufactured and the possibility of its use was evaluated.

  • PDF

Optical analysis of low concentration evacuated tube solar collector

  • Teles, Mavd R.;Carvalho, Raquel;Ismail, Kamal A.R.
    • Advances in Energy Research
    • /
    • 제5권3호
    • /
    • pp.227-237
    • /
    • 2017
  • The continuous increase of emission rates of green house gases and the effects on global warming added a new dimension to the problem of substituting the petroleum and its derivatives by environment friendly and sustainable energy sources for the world. Solar and wind energy appear at the top of the list of renewable of high potential, widely available, of dominated technology and well accepted. Brazil is one of the few countries in the world that receives number hours of sunshine exceeding 3,000 hours per year with a daily average of 4.5 to 6 kWh. However, this potential is largely unexplored and poorly tapped. The number of renewable systems implanted in Brazil has grown in recent years, but still insignificant when compared, for example, with Germany and Spain among others. This paper presents the results of an optical study on small concentration solar collector with evacuated tube enveloping the absorber and internal reflective surface fixed on the bottom part of the evacuated tube. The designed collector has a 2D geometrical concentration ratio between 2.455 and 4.91. The orientation of the solar collector, the ratio of the radius of the receiver to the radius of the absorber, the incidence angle for each period of the year, the collector inclination angle, the aperture angle of the reflective surface, concentration and optical efficiency were determined. The ray traces and flux distribution on the absorber of the evacuated tube solar collector were determined by using the program Ray Optics Simulation. The optical efficiency varies during the year according to the solar declination. For the periods were the solar declination is close to zero the efficiencies are maximum, and the variation during the day is around 25.88% and 99.9%. For the periods were the solar declination is maximum the efficiencies are minimum, and the variation during the day is around 23.78% and 91.79%.

주성분분석에 의한 TMY 특성 비교분석 (Comparative Analysis on the Characteristic of Typical Meteorological Year Applying Principal Component Analysis)

  • 김신영;김창기;강용혁;윤창열;장길수;김현구
    • 한국태양에너지학회 논문집
    • /
    • 제39권3호
    • /
    • pp.67-79
    • /
    • 2019
  • The reliable Typical Meteorological Year (TMY) data, sometimes called Test Reference Year (TRY) data, are necessary in the feasibility study of renewable energy installation as well as zero energy building. In Korea, there are available TMY data; TMY from Korea Institute of Energy Research (KIER), TRY from the Korean Solar Energy Society (KSES) and TRY from Passive House Institute Korea (PHIKO). This study aims at examining their characteristics by using Principle Component Analysis (PCA) at six ground observing stations. First step is to investigate the annual averages of meteorological elements from TMY data and their standard deviations. Then, PCA is done to find which principle components are derived from different TMY data. Temperature and solar irradiance are determined as the main principle component of TMY data produced by KIER and KSES at all stations whereas TRY data from PHIKO does not show similar result from those by KIER and KSES.

단독 주택의 제로에너지건축물 인증을 위한 태양광시스템 최적화에 관한 연구 (A Study on the Optimization of Photovoltaic System for the ZEB Certification in Detached Housing)

  • 신지웅;윤재현;고정림
    • 한국태양에너지학회 논문집
    • /
    • 제39권3호
    • /
    • pp.1-7
    • /
    • 2019
  • As part of the government's energy policy, Zero Energy Building certification was launched on January of 2017. However, the three passive-housing rental housing projects are the only ZEB-certified detached housing since the certification's launch. The reason is that, in order for a detached housing to earn ZEB certification, it has to secure self-reliance in energy, and a photovoltaic system is the only viable renewable energy system. Therefore, conducting an analysis to optimize the photovoltaic system in an early design stage is strongly recommended. This study aimed to propose an optimal photovoltaic system design for a detached housing after analyzing through the ECO2 energy simulation of 44 cases, varying in a module type and efficiency, inclination and azimuth. As a result, 15 cases out of 44 cases were analyzed to satisfy ZEB evaluation criteria, and it is thought that these data could contribute greatly to the expansion of ZEB certification dissemination.