• Title/Summary/Keyword: ZCP

Search Result 13, Processing Time 0.02 seconds

Advanced Brushless DC Motor Drive without Position Sensor for Home Appliances

  • Kim, Dae-Kyong;So, Ji-Young;Jung, Dong-Hwa
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.1
    • /
    • pp.83-90
    • /
    • 2013
  • This paper describes advanced brushless DC motor drive without position sensor for home appliances with compressor to reduce the pulsating currents and vibration. The proposed method limits the motor currents during starting period and reduces commutation torque ripple during sensorless operating period. Experimental results show that the proposed method implemented in an inverter for a BLDC motor driven compressor considerably reduces not only the pulsating currents but also vibration of the home appliances.

Method and implementation for reducing standby power consumption in intermediate capacity power supply with Power Line Communication (전력선통신기능 적용 중.대용량 전원공급장치의 대기전력 절감방법 및 구현)

  • Son, Do-Sun;Kim, Ki-Hyun;Kim, Sang-Cheol;Jeon, Eui-Seok;Lee, Sang-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1947-1948
    • /
    • 2008
  • This paper presents the implementation of Power Line Communication(PLC) module which can reduce standby-power consumption. The suggested PLC module consists of PLC modem, coupling circuit, ZCP(Zero-Cross Point) Circuit and main SMPS control relay. The test results under power line communication test-bed used home appliance show the 77% saving of standby-power.

  • PDF

Ultra-Power-Saving 2 Ports PLC Wall Switch Development (초절전형 PLC 2구 스위치 개발)

  • Han, Jae-Yong;Lee, Sun-Heum
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.11
    • /
    • pp.51-55
    • /
    • 2007
  • Generally, PLC (Power Line Communication) based home automation devices such as wall switch, walt socket, gas controller, etc, must maintain wake-up status at all time to control other electronic devices and monitor their on/off status whether they are in service or not. In order to reduce the unnecessary energy consumption during the standby mode, the new power-saving PLC 2 ports wall switch has been developed, separating PLC communication part and controller part and introducing sleep mode. In addition, to expand life cycle of PLC product and to reduce the rate of product failure in active mode, the instant controlling method in controlling process is adopted instead of the maintenance controlling method. In comparison to the earlier model, the new 2 ports PLC wall switch has reduced power by 0.95[W] less in standby mode and 3.2[W] less in active mode than the previous one.