• 제목/요약/키워드: Z-Factor

검색결과 598건 처리시간 0.026초

DETECTION OF Hα EMISSION FROM z>3.5 GALAXIES WITH AKARI-FUHYU NIR SPECTROSCOPY

  • Sedgwick, Chris;Serjeant, Stephen;Pearson, Chris;Takagi, Toshinobu;Matsuhara, Hideo;Wada, Takehiko;Lee, Hyung Mok;Im, Myungshin;Jeong, Woong-Seob;Oyabu, Shinki;White, Glenn J.
    • 천문학논총
    • /
    • 제27권4호
    • /
    • pp.357-360
    • /
    • 2012
  • This paper presents $H{\alpha}$ emission line detections for four galaxies at z > 3.5 made with AKARI as part of the FUHYU mission program. These are the highest-redshift $H{\alpha}$ detections to date in star-forming galaxies. AKARI's unique near-infrared spectroscopic capability has made these detections possible. For two of these galaxies, this represents the first evidence of their redshifts and confirms their physical association with a companion radio galaxy. The star formation rates (SFRs) estimated from the $H{\alpha}$ lines under-predict the SFRs estimated from their far-infrared luminosities by a factor of ~ 2 - 3. We have also detected broad $H{\alpha}$ components in the two radio galaxies which indicate the presence of quasars.

호흡기보호구의 밀착계수와 안면구조의 관계 (Correlation of Fit Factors for Respirators and Anthropometric Dimension)

  • 한돈희
    • Journal of Preventive Medicine and Public Health
    • /
    • 제31권3호
    • /
    • pp.440-448
    • /
    • 1998
  • In many developed countries, for example, USA, respirator fit testing is required before entering specific work environment to ensure that the respirator worn satisfies a minimum of fit and that the user knows when the respirator fits properly. Unfortunately because we have not fit test regulation in Korea, a lot of workers wearing respirators may be potentially exposed to hazards. This study was conducted to evaluate the fitting performance for respirators and correlation fit factors with facial dimensions of wearers. 110 subjects (70 males, 40 females) were fit tested for three quarter masks, i.e., two domestic-made Mask 2, and Y and one foreign-made Mask T using PortaCount 8020. A facial dimension survey of the same subjects was conducted to develop a facial dimension grids fer correlation fit factors with facial dimension parameters. A facial dimension grid was developed on the basis of face length and lip length for quarter masks. The results obtained were as follows : 1 Fit factors of Mask T were much higher than those of Masks Z, and Y. 2. Males were fitted more properly than females. 3. Male in box 'f' of grid would be adequately fitted Mask Y and male in box 'b', 'e', 'f', 'h' of grid would be sufficiently fitted Mask T. Female in box 'h' of grid may have a good fitting performance for both Mask Y, and T. But subjects in all boxes of grid would be inadequately fitted Mask Z.

  • PDF

단일현장타설말뚝을 이용한 교량기초의 설계 및 시공 사례 (A Case Study on the Design and Construction of the Pile Bent System)

  • 조성한;김형욱;김주철
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.357-367
    • /
    • 2010
  • In this study, several design and construction cases of the pile bent system for bridges were introduced. The lateral displacement of the pile bent system is larger than the displacement of pile cap system, due to the smaller bending stiffness and the longer unsupported length. So, the analysis of the lateral pile displacement is main factor for the design of pile bent system and superstructure. For the accurate estimation of the pile displacement, an iterative analysis method was developed. The superstructure was analyzed regarding the pile foundation as $6{\times}6$ spring and the substructure was analysed using non-linear load transfer curves (p-y, t-z, q-z curve). And, to verify this analysis method, the estimated displacements are compared with the results of lateral load test. This analysis method is expected to be a viable alternative approach for the design of bridge foundation hereafter.

  • PDF

Tetra-tert-butyl-tstrapropionyloxycalix [4] arene의 구조 (Structure of Tetra-ter-butyl-tetrapropionyloxycalix[4]arene)

  • 김회진;노광현
    • 한국결정학회지
    • /
    • 제4권1호
    • /
    • pp.25-35
    • /
    • 1993
  • Tetra-tert-butyl-tetrapropionyloxycalix (4) arena (C,6H,20s)의 분자 및 결정구조를 X-선 회절법으로 연구하였다. 이 결정은 삼사정계이고 공간군은 P1이다. 단위세포 길이는 a=13.664(5), b=17.585(5), c= 12.863(2)A이며 a=109.33(2), B=111.97(2), r=76.45(3) ˚, Z=2이다. 회절반점들의 세기는 흑연단색화 장치가 있는 Enraf-Nonius CAD-4 Diffractometer로 얻었으며, Mo-Ka X-선(A=0.7107A )을 사용하였다. 분자구조는 직접법으로 풀었으며 최소자 승법으로 정밀화하였다. 최종 신뢰도 R값은 2561개의 회절반점에 대하여 0.084이었다. 본 Calixarene은 partial cone conformation을 가져서 세개의 tort-butylphenyl group들과 하나의 tort-butylphenyl group의 상대적인 배열이 다르다. 세개의 propionyloxy group들은 macrocycle로 된 cavity바깥 쪽을 향하여 배열되어 있다.

  • PDF

Niclosamide monohydrate, $C_{13}H_8Cl_2N_2O_4\cdotH_2O$의 결정 및 분자구조 (The Crystal and Molecular Structure of Niclosamide monohydrate, $C_{13}H_8Cl_2N_2O_4\cdotH_2O$)

  • 김의성;신현소
    • 한국결정학회지
    • /
    • 제4권1호
    • /
    • pp.1-5
    • /
    • 1993
  • 니클로사미드 일수화물의 결정구조는 흑연으로 단색화된 Mo-Ka 방사선을 사용하는 자동 CAD4 회절 기로 측정된 1976개의 독립반점을 이용하여 결정되었다. 결정계는 단사정계이며, 공간군은 P211c이고, 293k에서 단위세포 상수는 a=11.331(3), b=6.964 (2), c=7.347(4)A, p=98.20(3)°, Z=4이다. 구조는 ggg Parity군에 속하는 반불변수를 이용하는 직접법으로 해석하였으며, 완전행렬 최소자승법으로 정밀화하여 최종 신뢰도 R=0.046인 모형을 구하였다. 분자 모양은 ab평면상에 평행하게 놓이는 평면성 구조를 나타낸다.

  • PDF

ARQ 방식을 적용한 무선 센서 네트워크의 QoS 해석 (QoS Analysis of Wireless Sensor Network with ARQ Scheme)

  • 노재성;김완태
    • 한국항행학회논문지
    • /
    • 제14권1호
    • /
    • pp.49-56
    • /
    • 2010
  • 심각한 에너지의 제한과 저전력 소모 조건은 무선 센서 네트워크에서 에너지 효율적인 에러제어 메커니즘의 중요성을 요구하고 있다. 본 논문에서는 에러 제어 기법의 해석을 위하여 ARQ 기법이 제시되었으며 패킷길이의 영향, 변조방식, 무선채널에서 간섭의 영향을 분석하였다. 더욱이, ARQ 에러 제어의 해석은 무선 센서 네트워크에서 주요한 Mica2 and MicaZ 센서 노드를 대상으로 고려하였다. 본 논문에서는 다중간섭 채널에서 선택 재전송 ARQ 방식을 적용한 비동기 FSK 신호와 DSSS-OQPSK 신호의 처리율 성능을 분석하였고 목적 노드로부터 수집 노드까지 올바르게 수신된 비트와 패킷의 수신 확률을 채널 파라미터, 무선 센서 노드의 수, 확산지표에 따라서 평가하였다.

A parameter calibration method for PFC simulation: Development and a case study of limestone

  • Xu, Z.H.;Wang, W.Y.;Lin, P.;Xiong, Y.;Liu, Z.Y.;He, S.J.
    • Geomechanics and Engineering
    • /
    • 제22권1호
    • /
    • pp.97-108
    • /
    • 2020
  • The time-consuming and less objectivity are the main problems of conventional micromechanical parameters calibration method of Particle Flow Code simulations. Thus this study aims to address these two limitation of the conventional "trial-and-error" method. A new calibration method for the linear parallel bond model (CM-LPBM) is proposed. First, numerical simulations are conducted based on the results of the uniaxial compression tests on limestone. The macroscopic response of the numerical model agrees well with the results of the uniaxial compression tests. To reduce the number of the independent micromechanical parameters, numerical simulations are then carried out. Based on the results of the orthogonal experiments and the multi-factor variance analysis, main micromechanical parameters affecting the macro parameters of rocks are proposed. The macro-micro parameter functions are ultimately established using multiple linear regression, and the iteration correction formulas of the micromechanical parameters are obtained. To further verify the validity of the proposed method, a case study is carried out. The error between the macro mechanical response and the numerical results is less than 5%. Hence the calibration method, i.e., the CM-LPBM, is reliable for obtaining the micromechanical parameters quickly and accurately, providing reference for the calibration of micromechanical parameters.

색각 검사용 Farnsworth Test Panel D-15의 칼라 인자 연구 (Color Factor Analysis of in Farnsworth Test Panel D-15)

  • 김용근;박상안
    • 한국안광학회지
    • /
    • 제5권1호
    • /
    • pp.31-37
    • /
    • 2000
  • 제1~3색각 이상 검사용 Farnsworth Dichotomous Test Panel D-15의 칼라분석을 위하여 380~780 nm의 반사광 spectrum 세기를 측정하여 CIE system을 도입하였다. Panel D-15의 색상변환은 650nm 이상, 500~600 nm, 400~450 nm의 3개 파장영역의 광 반사율 세기에 의존한다. 반사 spectrum으로부터 3극치 X, Y, Z 값, 보색 평면과 명암축으로 하는 3차원 CIELAB system의 $L^*a^*b^*$와 Lab 값, CIELUV system $U^*V^*$ 값, 색도도 좌표 x, y 값을 구했다.

  • PDF

The Effect of Polysaccharide from Angelica Gigas Nakai on Controlling the Differentiation of Human Embryonic Stem Cells

  • Park, Young-S.;Lee, Jae-E.;Lee, Seo-H.;Lee, Hyeon-Y.
    • 한국약용작물학회지
    • /
    • 제10권4호
    • /
    • pp.237-242
    • /
    • 2002
  • It was found that the purified extract from A. gigas Nakai (polysaccharide, M.W., 25 kD) controled differentiating human ES cells. Its optimal supplementation concentration was decided as 0.8 $({\mu}g/ml)$ to efficiently control the differentiation. It also enhanced the cell growth, compared to the control. However, most widely used and commercially available differentiating agent, Leukemia Inhibitory Factor (LIF) negatively affected on the cell growth even though it controls the differentiation of ES cells, down to 40-50 % based on morphological observation and telomerase activity. It was presumed that the extract first affected on cell membrane and resulted in controlling signal system, then amplify gene expression of telomere, which enhanced the telomerase activity up to three times compared to the control. LIF only increased the enzyme activity up to two times. It was confirmed that the extract from A. gigas Nakai could be used for substituting currently used differentiation controlling agent, LIF from animal resources as a cheap plant resource and not affecting the cell growth. It can broaden the application of the plants not only to functional foods and their substitutes but also to fine chemicals and most cutting-edge biopharmaceutical medicine.

지역사회 요실금 여성의 골반저근운동과 자기장자극 효과비교 (A Comparative Study on the Effects on Urinary Incontinence between Pelvic Floor Muscle Exercise and Magnetic Stimulation Therapy)

  • 조명숙;강혜영
    • 지역사회간호학회지
    • /
    • 제19권4호
    • /
    • pp.696-703
    • /
    • 2008
  • Purpose: To Perform a randomized comparative study investigating the effects of Pelvic Floor Muscle Exercise(PME) and Magnetic Stimulation Therapy(MST) and to identified the problems in each of PME & MST Method: Forty-nine patients with mild stress incontinence were randomly assigned to either of two treatment groups (24 patients in the PME group and 25 in the MST group). The PME group had a video exercising program for 40 times every day during 6 weeks. The MST group was treated with BioCon-2000TM, 2times/ week for six weeks. Pre-test and post-test were performed by Prineometer, 1-hour pad test. and Jackson's BFLUTS questionnaire of Jackson. Collected data were analysed using SAS 9.1 by frequency, Kolmogorov-Smirnov Z. Chi Square-test, t-test, Fisher Exact probability test, Paired t-test, and Wilcoxon's rank sum test. Results: In comparison between before and after PME and MST, statistically significant difference was observed in maximal vaginal pressure, duration of vaginal contraction, amount of urine, and symptom of urination. In the comparison of the effectiveness between PME & MST, only the maximal of vaginal pressure (Z=2.58, p= .010) was significantly different. Conclusion: The factor more effective in the MST group than in the PME group was high compliance.

  • PDF