• 제목/요약/키워드: Yield Criterion

검색결과 282건 처리시간 0.03초

Equivalent linear and bounding analyses of bilinear hysteretic isolation systems

  • Wang, Shiang-Jung;Lee, Hsueh-Wen;Yu, Chung-Han;Yang, Cho-Yen;Lin, Wang-Chuen
    • Earthquakes and Structures
    • /
    • 제19권5호
    • /
    • pp.395-409
    • /
    • 2020
  • With verifications through many relevant researches in the past few decades, adopting the equivalent lateral force procedure for designing seismically isolated structures as a preliminary or even final design approach has become considerably mature and publicly acceptable, especially for seismic isolation systems that mechanically exhibit bilinear hysteretic behavior. During the design procedure, in addition to a given seismic demand, structural designers still need to previously determine three parameters, such as mechanical properties of seismic isolation systems or design parameters and performance indices of seismically isolated structures. However, an arbitrary or improper selection of given parameters might cause diverse or even unacceptable design results, thus troubling structural designers very much. In this study, first, based on the criterion that at least either two design parameters or two performance indices of seismically isolated structures are decided previously, the rationality and applicability of design results obtained from different conditions are examined. Moreover, to consider variations of design parameters of seismically isolated structures attributed to uncertainties of mechanical properties of seismic isolation systems, one of the conditions is adopted to perform bounding analysis for seismic isolation design. The analysis results indicate that with a reasonable equivalent damping ratio designed, considering a specific variation for two design parameters (the effective stiffness and equivalent damping ratio) could present more conservative bounding design results (in terms of isolation displacement and acceleration transmissibility) than considering the same variation but for two mechanical properties (the characteristic strength and post-yield stiffness).

Genetic Analysis of Growth Response to Cold Water Irrigation in Rice

  • Han, Long-Zhi;Koh, Hee-Jong
    • 한국작물학회지
    • /
    • 제45권1호
    • /
    • pp.26-31
    • /
    • 2000
  • This study was carried out to obtain the basic information for breeding cold-tolerant rice varieties with high yield-productivity through wide crosses between indica and japonica rice. Genetic analysis was conducted using 55 F$_1$s obtained from half-diallel crosses among eleven cultivars of various origin including indica and japonica rice. Screening for cold tolerance was done with cold-water irrigation after transplanting until ripening stage. Both general combining ability (GCA) and specific combining ability (SCA) effects were highly significant in all characters associated with dry matter accumulation at 30 and 50days after cold-water irrigation (DAC). The variance of GCA was much larger than that of SCA in plant height, shoot dry weight per plant (DWP), crop growth rate (CGR) and cold-water response index (CRI) of these characters except CRI of shoot dry weight per plant. The DWP, CGR and CRI of these characters of Gaochan 102, Tong88-7 and TR22183 were markedly higher than those of the others. GCA effects of these varieties on DWP, CGR and their CRI were also higher than those of the others, indicating that they are useful as promising parents for breeding cold-tolerant varieties. Analysis of genetic parameters for 11$\times$11 half-diallel F$_1$s revealed that inter-locus gene interaction were concerned in the expression of plant height at 50 DAC, CRI of DWP at 50 DAC, and CRI of CGR, and that intra-locus gene interaction for plant height and the other characters were partial dominance and over-dominance, respectively. Narrow-sense heritability (h$^2$$_{N}$) was the highest in plant height as 0.729, and the lowest in CRI of DWP at 30 DAC as 0.048, suggesting that selection for cold tolerance will be quite effective in case that the selection criterion is the performance itself.f.

  • PDF

가변 확산이득 구조의 멀티미디어 멀티레이트 DS/CDMA 시스템에서 PN 시퀀스 위상에 따른 성능 영향 분석 (Effects of PN Sequence Phase on Performance of Variable Spreading Gain (VSG) Multi-media Multi-Rate DS/CDMA)

  • 이연우;차균현
    • 한국통신학회논문지
    • /
    • 제24권12A호
    • /
    • pp.1833-1843
    • /
    • 1999
  • 본 논문에서는 가변확산이득 (VSG)구조를 갖는 멀티미디어 멀티레이트 DS/CDMA 시스템에서 PN 시퀀스의 위상에 따른 다중접속 간섭을 분석하였고, 결정적인(deterministic) 시퀀스에 의한 비트 오율 성능분석을 수행하기 위해서 다른 확산 이득과 다른 송신 전력을 갖는 다중 접속 간섭 사용자에 대해서 비트 오율 식을 유도하였다. 다른 확산 이득과 다른 송신 전력을 갖는 다중 접속 간섭 사용자에 대해서 비트 오율 식을 유도하였다. 다른 확산 이득과 다른 송신 전력을 갖는 다중 접속 간섭 사용자에 대해서 비트 오율 성능을 구한 결과, 기준 사용자의 데이터 전송률에 따라 다중 접속 간섭을 결정하는 요소가 달라짐을 보였다. 또한, 신호대 잡음비 $E_b/N_o$가 10dB이하인 경우에는 AWGN이 성능을 결정하는 지배적인 요소로 작용하기 때문에 시퀀스의 초기 위상에 의한 이득을 거의 기대할 수 없지만, $E_b/N_o$가 증가할수록 MSQCC/CO와 CO/MSQCC 기준에 의한 시퀀스 초기 위상의 선택기준이 성능을 가장 향상시킬 수 있는 최적의 선택기준이라는 결론을 얻을 수 있었다.

  • PDF

관통형 고력볼트를 사용한 엔드플레이트형식 CFT 기둥-H형강 보 접합부의 전단성능 (The Shear Capacity of CFT Column to H-Beam End plate Connections with Penetrated High-Strength Bolts)

  • 김영주;김재건;오영석;문태섭
    • 한국강구조학회 논문집
    • /
    • 제12권4호통권47호
    • /
    • pp.351-362
    • /
    • 2000
  • 이 논문은 반복하중을 받는 관통형 고력볼트를 사용한 엔드플레이트형식 콘크리트 충전 각형강관 기둥-H형강 보 접합부의 거동에 관한 연구이다. 주요변수는 엔드플레이트의 두께(16mm, 22mm, 25mm)와 기둥의 두께(9mm, 12mm)이다. 각 변수에 대해 실험결과와 비교 분석한다. 보-기둥 접합부의 에너지 흡수능력을 구하고, 접합부 패널의 전단내력을 분석한다. 접합부 패널의 전단 내력은 von Mises 항복조건에 의한 강재의 내력과 콘크리트 충전효과를 고려한 Strut 모델을 사용한 콘크리트의 내력을 단순누가해서 구한다.

  • PDF

과배란 처치시 우세난포 조절에 의한 한우 수정란 생산성 향상에 관한 연구 II. 과배란 처치 시기에 따른 난소반응 (Superovulation response after follicular wave synchronization with follicular aspiration by ultrasonography in HanWoo II. Ovarian response following superovulation treatment at different day of estrus)

  • 이동원;이병천;황우석
    • 대한수의학회지
    • /
    • 제40권4호
    • /
    • pp.769-775
    • /
    • 2000
  • This study was investigated the ovarian response following superovulation treatment at different day of diestrus. The criterion for the presence or absence of a dominant follicle based on their morphological examination. Dominant follicle was puntured 48 hrs before the oneset of superovulation treatment by ultrasonography guided aspiration needle. Superovulation was induced by subcutaneous administration of FSH twice a day for 4 day in a decreasing regimen. There was no significant different between presence of dominont follicle and progesterone concentration/diameter of corpus luteum in HanWoo. Number of corpus luteum of donor after superovulation treatment was not significantly different in FSH administration at day 9, 11 and day 13 of estrus($14.5{\pm}4.5$, $15.5{\pm}5.6$ and $11.0{\pm}5.5$, respectively). But, the diameter of CL was significantly correlate(R2 = 0.757) with progesterone levels on day of superovulatory induction. After 7 days of artificial insemination, the embryos at 7 days were collected by uterine flushing after dominant follicle aspiration and superovulation treatment, and evaluated their quality by morphological criteria. Fifty five embryos with excellent, good and fair grade were transferred into 24 recipient cows. Seventeen offsprings, 1 of triplet, 4 of twins and 6 of singlet, were yield from 10 recipient cow. In conclusion, the present study showed that 1) dominant follicle can be determined by ultrasonography with rectal palpation by morphological evaluations, 2) superovulation response after follicular aspiration was not differ at day 9, 11 and 13 of estrus, 3) dominant follicle did not affect to progesterone concentration and diameter of CL, and 4) diameter of CL was significantly correlate to the level of progesterone concentrations in HanWoo.

  • PDF

포천석분의 응력-변형률 거동특성 (Characteristics of Stress-Strain for Pocheon stone sludge)

  • 김찬기;박권준;조원범;이종천
    • 한국지반신소재학회논문집
    • /
    • 제12권3호
    • /
    • pp.55-64
    • /
    • 2013
  • 본 연구는 포천석분을 재성형하여 등방압축-팽창시험과 구속압력을 달리한 일련의 비배수삼축압축시험을 실시하여 Lade 단일항복면 구성모델의 토질매개변수를 결정하였으며, 실험결과의 역해석을 통하여 단일항복면 구성모델의 적용성과 포천석분의 거동특성을 확인하였다. 그 결과 포천석분은 축변형률이 증가함에 따라 축차응력이 증가하는 경화현상을 보이고 있으며 큰축변형률에서 파괴되므로 실용적인 파괴기준을 검토할 필요성을 확인하였으며, 구성모델의 11개 토질매개변수를 이용하여 시험치를 역해석한 결과 응력-변형거동을 양호하게 예측하지만 항복함수에 관련된 토질매개변수를 파괴규준에 관련한 상관식과 상수로 역해석한 경우는 다소 상이한 양상을 보이고 있다.

Self-consolidating concrete filled steel tube columns - Design equations for confinement and axial strength

  • Lachemi, M.;Hossain, K.M.A.;Lambros, V.B.
    • Structural Engineering and Mechanics
    • /
    • 제22권5호
    • /
    • pp.541-562
    • /
    • 2006
  • This paper compares the performance of axially loaded concrete filled steel tube (CFST) columns cast using a conventionally vibrated normal concrete (NC) and a novel self-consolidating concrete (SCC) made with a new viscosity modifying admixture (VMA). A total of sixteen columns with a standard compressive strength of about 50 MPa for both SCC and NC were tested by applying concentric axial load through the concrete core. Columns were fabricated without and with longitudinal and hoop reinforcement (Series I and Series II, respectively) in addition to the tube confinement. The slenderness of the columns expressed as height to diameter ratio (H/D) ranged between 4.8 and 9.5 for Series CI and between 3.1 and 6.5 for Series CII. The strength and ductility of SCC columns were found comparable to those of their NC counterparts as the maximum strength enhancement in NC columns ranged between 1.1% and 7.5% only. No significant difference in strain development was found due to the presence of SCC or NC or due to the presence of longitudinal and hoop reinforcement. Biaxial stress development in the steel tube as per von Mises yield criterion showed similar characteristics for both SCC and NC columns. The confined strength ($f^{\prime}_{cc}$) of SCC was found to be lower than that of NC and $f^{\prime}_{cc}$ also decreased with the increase of slenderness of the columns. Analytical models for the prediction of confined concrete strength and axial strength of CFST columns were developed and their performance was validated through test results. The proposed models were found to predict the axial strength of CFST columns better than existing models and Code based design procedures.

판구조물의 설계감도해석 및 신뢰성해석 (Design Sensitivity and Reliability Analysis of Plates)

  • 김지호;양영순
    • 전산구조공학
    • /
    • 제4권4호
    • /
    • pp.125-133
    • /
    • 1991
  • 구조응답이나 상태함수가 음함수(implicit function)형태로 주어지는 복잡한 구조물의 설계감도해석 및 신뢰성해석을 효율적으로 수행할 수 있는 방법을 개발하기 위하여, 먼저 확률 유한요소법을 사용한 확정론적 감도해석 방법을 정식화하고, 이를 바탕으로 MVFOSM, AFOSM 및 SORM등의 2차 모우먼트 방법에 의한 신뢰성 해석을 수행하였으며, 또한 신뢰성에 기초한 최적설계를 수행하는 경우에 필요한 확률론적 설계감도해석 방법을 제시하였다. 수치해석 예로서 박판 구조물의 평면응력문제와 판굽힘문제에 대한 해석을 수행하였는데, 초기 항복이 발생하는 경우를 파괴상태로 정의하였으며, 외부하중, 항복응력, 판두께, 탄성계수 및 Poisson비 등을 확률변수로 다루었다. 모든 경우에 있어서, 본 논문에서 제시한 방법으로 구한 구조응답의 분산이나 파괴확률이 Monte Carlo simulation의 결과와 잘 일치함을 알 수 있었으며, 또한 신뢰성설계시, 확률론적 감도해석결과로부터 확률변수들의 상대적 중요도를 파악할 수 있을 뿐만 아니라, 설계변수(혹은 확률변수)의 평균 혹은 분산계수의 변화에 따른 신뢰성지수의 변화량을 미리 예측할 수도 있다.

  • PDF

탄소성(彈塑性) 지반(地盤)위에 놓인 원형평판(圓形平板)의 유한요소(有限要素) 해석(解析) (A Finite Element Analysis of Circular Plate Resting on Elasto-Plastic Soil Medium)

  • 김성덕;장승필
    • 대한토목학회논문집
    • /
    • 제7권4호
    • /
    • pp.91-102
    • /
    • 1987
  • Boussinesq 지반형(地盤型)의 탄소성체지반(彈塑性體地盤)위에 놓인 원형평판(圓形平板)이 축대칭하중(軸對稱荷重)을 받았을 경우의 거동을 파악하기 위하여 8절점(節點) 등매개변수요소(媒介變數要素)를 사용한 유한요소해석(有限要素解析) 방법(方法)을 이론적(理論的)으로 발전시키고 이를 수행하기 위한 컴퓨터 프로그램을 개발하였다. 이론(理論)의 정당성을 입증하기 위해 모형실험을 수행한 결과 지반(地盤)의 항복조건으로 Mohr-Coulomb 강복이론(降伏理論)을 적용한 수치해(數値解)의 결과(結果)와 실험결과(實驗結果)가 근사함을 확인하였다. Mohr-Coulomb의 파괴이론(破壞理論)을 적용한 비선형해석(非線型解析)을 수행한 예제(例題)의 결과로 부터, 지반의 소성영역(塑性領域)이 원판(圓板)의 녹단부근(綠端附近)에서 발생하기 시작하여 중심축둘레로 연결되었을 때 접지압(接地壓)이 급격히 변하여 전단파괴(剪斷破壞)의 위험성(危險性)이 있다고 판단되고 이 때의 외부작용하중(外部作用荷重)을 임계하중(臨界荷重)으로 정의하였다.

  • PDF

신뢰성에 기초한 강상형 보도육교의 안전도 및 내하력 평가 (Reliability-Based Assessment of Safety and Load Carrying Capacity of Steel-Box Pedestrian Bridges)

  • 조효남;최영민;이은철
    • 전산구조공학
    • /
    • 제10권2호
    • /
    • pp.189-201
    • /
    • 1997
  • 국내 보도육교의 경우, 단순한 구조형식과 공장제작에 의한 현장조립의 신속한 시공 및 유지관리상의 장점들로 인하여 표준화된 강상형 보고육교가 교통혼잡이 심한 도심지와 각종 국도상에 다수 건설되어 왔지만, 이중 상당수의 육교가 공용년수 증가와 더불어 열화손상되어 안전도 및 사용성이 매우 불량한 상태에 있다. 본 논문에서는 열화손상된 기존의 강상형 보도육교의 실제적인 안전도 및 잔존내하력을 평가하기 위하여 선진각국에서는 이미 일반화되고 있는 von Mises'조합응력항복기준에 기반을 둔 한계상태설계법에 기초하여 각 구조부위의 항복 및 좌굴에 대한 각각의 비선형 한계상태모형을 제안하고 이를 실구조물에 적용해서 안전도평가 및 신뢰성평가를 수행하여 제안된 모형의 타당성을 고찰하였다. 뿐만아니라 노후된 기존 강상형 보도육교에 대한 현장재하시험 방법과 이들 시험결과를 이용한 실용적이고 합리적인 잔존내하력 평가방법을 제안하고 각국 시방서별/설계방법별로 비교, 고찰하였다.

  • PDF