• Title/Summary/Keyword: YOON's test

Search Result 2,047, Processing Time 0.03 seconds

Buckling Behavior of a Square Tube Structure by Lateral Impact Load (사각 관 구조물의 충격에 의한 좌굴특성)

  • Yoon, K.H.;Song, K.N.;Kang, H.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.812-818
    • /
    • 2001
  • The drop type impact test and finite element analysis are established for examining the buckling behavior of a square tube under the lateral impact load. Based on these results, the effects by the boundary conditions for supporting the structure are reviewed, which are as follows. One is pinned condition by screw; the other is fixed by welding. The critical impact force and acceleration by test are nearly same between two cases. However, the critical impact velocity of the pinned condition is higher than that of the fixed case. Therefore, the dynamic buckling behavior of a pinned structure is better than the fixed condition in view of critical impact velocity. These test and analysis results will be adaptable for predicting the dynamic structural integrity of a tube structure not only the axial impact event but the lateral impact event.

  • PDF

Effects of Defect Size on Crush Test Load of Butt Fusion Welded MDPE Pipes

  • Tun, Nwe Ni;Lai, Huan Sheng;Jeon, Gyu Min;Yoon, Kee Bong;Kil, Seong Hee
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.55-62
    • /
    • 2015
  • It is expected that the size of welding defect affects the mechanical performance of welded medium density polyethylene (MDPE) pipe joints. In this study, butt fusion welded MDPE pipe joints with a single spherical or planar defect of various sizes were studied using experimental crush testing and also by finite element method. The crush test showed that the mechanical performance of crush was not affected by the size and geometry of a single welding defect when the defect size was increased to 45% of the pipe's wall thickness. The simulation results indicated that the effect of the single welding defect on the Von Mises stress distribution near the defect explained the reason of the test results.

Studies of Coagulase Production and Isolation of R-plasmid from Staphylococcus aureus (Staphylococcus aureus의 Coagulase 생성능과 R-플라스미드 분리에 관한 연구)

  • Yoon, Hyo-Sook;Lee, Hyung-Hoan;Kim, Soo-Young
    • The Journal of the Korean Society for Microbiology
    • /
    • v.22 no.3
    • /
    • pp.259-266
    • /
    • 1987
  • A total of 129 clinical isolates of Staphylococcus species was characterized by the tests of coagulase production, haemagglutination, mannitol fermentation, DNase production and hemolysis. Ninety-nine out of them showed positive reactions to the tests, therefore they were identified as Staphylococcus aureus. The isolates showing positive reaction in haemagglutination test also showed 100% of tube coagulase positive reaction. The haemagglutination test was a reliable method for identifying Staphylococcus aureus in the clinical laboratory. S. aureus produced stronger hemolysis with human blood agar than with sheep blood agar. Antibiotic resistant S. aureus isolates(S-46, S-112, S-126) had 4 to 6 p]asmid DNA elements. The S-112 strain had 6 plasmid DNA elements(1.8, 2.2, 3.7, $26.3{\sim}50$, and 70 Mdaltons), the S-126 had 4 elements(2.6, 4.2, $4.6{\sim}60Md$), and the S-46 had 1 element(${\sim}100Md$). PPSA strain had 4 plasmid DNA elements(2.5, 4.2, $4.6{\sim}60Md$) and S. aureurs(ATCC) strain contained 9.4, 26.3 and ${\sim}50Md$ plasmid DNA elements.

  • PDF

Common features of atopic dermatitis with hypoproteinemia

  • Jo, So Yoon;Lee, Chan-Ho;Jung, Woo-Jin;Kim, Sung-Won;Hwang, Yoon-Ha
    • Clinical and Experimental Pediatrics
    • /
    • v.61 no.11
    • /
    • pp.348-354
    • /
    • 2018
  • Purpose: The purpose of this study was to identify the causes, symptoms, and complications of hypoproteinemia to prevent hypoproteinemia and provide appropriate treatment to children with atopic dermatitis. Methods: Children diagnosed with atopic dermatitis with hypoproteinemia and/or hypoalbuminemia were retrospectively reviewed. The patients' medical records, including family history, weight, symptoms, treatment, complications, and laboratory test results for allergies and skin cultures, were examined. Results: Twenty-six patients (24 boys) were enrolled. Seven cases had growth retardation; 7, keratoconjunctivitis; 6, aural discharges; 5, eczema herpeticum; 4, gastrointestinal tract symptoms; and 2, developmental delays. In 21 cases, topical steroids were not used. According to the blood test results, the median values of each parameter were elevated: total IgE, 1,864 U/mL; egg white-specific IgE, $76.5kU_A/L$; milk IgE, $20.5kU_A/L$; peanut IgE, $30kU_A/L$; eosinophil count, $5,810/{\mu}L$; eosinophil cationic protein, $93.45{\mu}g/L$; and platelet count, $666.5{\times}10^3/{\mu}L$. Serum albumin and total protein levels decreased to 2.7 g/dL and 4.25 g/dL, respectively. Regarding electrolyte abnormality, 10 patients had hyponatremia, and 12, hyperkalemia. Systemic antibiotics were used to treat all cases, and an antiviral agent was used in 12 patients. Electrolyte correction was performed in 8 patients. Conclusion: Hypoproteinemia accompanying atopic dermatitis is common in infants younger than 1 year and may occur because of topical steroid treatment continuously being declined or because of eczema herpeticum. It may be accompanied by growth retardation, keratoconjunctivitis, aural discharge, and eczema herpeticum and can be managed through skin care and topical steroid application without intravenous albumin infusion.

Development of CINEMA Mission Uplink Communication System

  • Yoon, Na-Young;Yoon, Se-Young;Kim, Yong-Ho;Yoon, Ji-Won;Jin, Ho;Seon, Jong-Ho;Chae, Kyu-Sung;Lee, Dong-Hun;Lin, Robert P.
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.1
    • /
    • pp.33-40
    • /
    • 2012
  • Triplet Ionospheric Observatory (TRIO) CubeSatforIon, Neutral, Electron MAgneticfields (CINEMA) is a CubeSat with the weight 3 kg that will be operated in the orbit conditions of about 800 km altitude and $90^{\circ}$ inclination angle, using the S-band and ultra-high frequency (UHF)-band communication frequencies. Regarding the communication antenna loaded on the satellite, the two patch antennas has the downlink function in the S-band, whereas the two whip antennas has the function to receive the command sent by the ground station to the satellite in the UHF-band. The uplink ground station that communicates through the UHF-band with the CINEMA satellite was established at Kyung Hee University. The system is mainly composed of a terminal node controller, a transceiver, and a helical antenna. The gain of the helical antenna established at the Kyung Hee University ground station was 9.8 dBi. The output of the transceiver was set to be 5 W (6.9 dB) for the communication test. Through the far-field test of the established system, it was verified that the Roman characters, figures and symbols were converted into packets and transmitted to the satellite receiver in the communication speed of 9,600 bps.

A preliminary study on women's anginal pain induced by exercise stress test (운동부하검사로 유발된 여성의 협심통증에 대한 예비연구)

  • Choe, Myoung-Ae;An, Kyung-Ae;Choo, Ji-Na;Choi, Yoon-Sik
    • Journal of Korean Biological Nursing Science
    • /
    • v.4 no.2
    • /
    • pp.5-18
    • /
    • 2002
  • Purpose: Women have been often underdiagnosed and undertreated when they have as high mortality as men of ischemic heart disease, such as angina. One of the reasons of women's under treatment is associated with either vague, non-traditional symptoms or longer delay in seeking professional help when they experience ischemic heart disease. This study was conducted to investigate the characteristics of women's anginal pain induced by the treadmill test and to explore the potential relationship(s) between anginal pain and other psycho-physiologic factors. Methods: Of 22 female patients referred to treadmill test, 7 with positive finding participated in this study. Anginal pain in the past was analyzed by Rose questionnaire, whereas anginal pain induced by the treadmill test was identified by McGill pain scale, visual analogue scale and present pain index. Results: Women expressed more heaviness than sharp pain, and complained splitting more often than subjects in previous study that included both men and women. Pain intensity by VAS $3.64{\pm}3.94$, Pain rating index was $5.14{\pm}7.29$, present pain index was $1.57{\pm}1.81$, duration of pain was $5.14{\pm}4.8$ min. Exercise intensity was $6.0{\pm}4.63$ METs, exercise duration was $364.29{\pm}141.39$ sec, ST change was -2.0mm and rate of perceived exertion was $16.29{\pm}2.06$. The relationships between pain intensity and pain duration, ST segment changes were significant. Correlation among pain measures was significant. Conclusion: Generalization of these pilot findings may be inappropriate, and therefore, further larger study is needed.

  • PDF

Comparison of the Antidepressant Activity of Cirsii herbal Extracts Collected from 5 Different Regions of Korea Determining the Optimal Herbal Preparation (원료 생약 추출물의 최적화를 위한 한국 5개 지역에서 채집된 대계 추출물들의 항우울 효과 비교)

  • Lee, Hye Lim;dela Pena, June Bryan I.;Yoon, Seo Young;Kim, Seong Mok;Hong, Eunyoung;Lee, Yong Soo;Jang, Miran;Kim, Gun-Hee;Cheong, Jae Hoon
    • YAKHAK HOEJI
    • /
    • v.56 no.6
    • /
    • pp.401-406
    • /
    • 2012
  • Previously, we identified that Cirsium japonicum (CJ) extract posses antidepressant properties. In order to look for the optimal hebal preparation, CJ extracts collected from Koheung, Yesan, Cheju, Pyungchang and Pocheon were compared. The psychopharmacological activities of each extract were investigated using the open field test, the rota-rod test and the forced swimming test. Effect of each extract on $Cl^-$ influx in neuroblastoma cells were also identified. All of the extracts were orally administered at dosages of 50, 100, 200, 400 mg/kg of body weight. Supplementation of CJ did not significantly alter psychomotor behaviors such as movement, rearing frequency and total turn angle on the open field. Supplementation of CJ's extract from Pyungchang (100 mg/kg, p.o.), Cheju (200 and 400 mg/kg p.o.) and Yesan (100 and 200 mg/kg, p.o.) significantly decreased immobile duration and increased mobile duration in the forced swimming test. All of extracts have no influence on NE uptake in HEK-293 cells, but increased $Cl^-$ influx in neuroblastoma cell. The extract from Yesan demonstrated the most potent effect on $Cl^-$ influx. These results indicate that CJ's extracts from Pyungchang, Cheju and Yesan may alleviate depression, and the extract from Yesan may be the most effective preparation.

Perceptions and attitudes of dental hygienists toward radiation safety and protection in the Republic of Korea

  • Yun, Kwidug;Lee, Kyung-Min;An, Seo-Young;Yoon, Suk-Ja;Jeong, Ho-Gul;Lee, Jae-Seo
    • International Journal of Oral Biology
    • /
    • v.46 no.4
    • /
    • pp.168-175
    • /
    • 2021
  • To investigate the perceptions and attitudes of dental hygienists toward radiation safety management in Korea. A total of 800 dental hygienists were randomly selected for an anonymous survey, and 203 of them participated. The questionnaire items included the following: sex, career period, type of installed radiographic equipment, recognition of the diagnostic reference level (DRL), participation in radiation safety education, and attitudes toward radiation protection for both patients and dental hygienists. The participants were divided into two groups according to their years of experience (< 10 years versus ≥ 10 years). The difference between the groups was investigated according to frequency distribution. Fisher's exact test or Pearson's chi-square (𝛘2) test was used as appropriate. A regression analysis was performed to investigate the impact of wearing a thyroid collar for personnel protection during patient radiation exposure. The types of installed radiographic equipment included panoramic radiography (96.1%), cephalometric radiography (76.9%), intraoral radiography (72.9%), and cone-beam computed tomography (69.5%). Significant differences were observed in the learning pathway for the DRL (Fisher's exact test, p < 0.05), satisfaction with radiation safety education (Pearson's 𝛘2 test = 5.3975, Pr = 0.02), and use of personnel radiation monitoring systems (Pearson's 𝛘2 test = 18.1233, Pr = 0.000) between the groups. Significant differences were also observed in personnel protection using a thyroid collar and patient protection during panoramic radiography (odds ratio = 14.2). Dental hygienists with more than 10 years of experience were more satisfied with radiation safety education and more interested in radiation monitoring. Considering career experience, customized, continuous, and effective radiation safety management education should be provided.

Radionuclide Tubal Function Test (방사핵을 이용한 난관기능검사)

  • Roh, T.S.;Kim, J.G.;Yoon, B.H.;Moon, S.Y.;Lee, J.Y.;Chang, Y.S.;Chung, J.K.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.14 no.1
    • /
    • pp.1-6
    • /
    • 1987
  • The Radionuclide test (RN test) using radioactively labelled human albumin microspheres was developed recently to evaluate the patency and functional capacity of the fallopian tubes. 57 infertile women underwent this procedure as a part of their infertility work up. The results of the radionuclide evaluation were compared with those of the hysterosalpingography (HSG) and further the surgical findings of the laparoscopy and laparotomy. In 64.9%(37/57) of the cases, there was complete agreement between radionuclide test (RN test), hysterosalpingography(HSG) and surgical findings. In comparison with surgical findings, RN test showed a complete agreement rate of 89.4%(51/57), a partial agreement rate of 5.3%(3/57) and no agreement rate of 5.3%(3/57), respectively. Likewise, HSG revealed a complete agreement rate of 80.7%(46/57), a partial agreement rate of 10.5%(6/57) and no agreement 8.8%(5/57), respectively. It would appear that as opposed to the traditional HSG, RN test may give a better understanding of the functional capacity of the tube and may prove a useful method before and after tubal surgery.

  • PDF

Braking Force Test Evaluation Dynamometer Development of Vehicle (차량용 브레이크 제동력 평가 다이나모미터 개발)

  • Kwon, Byeong-Heon;Yoon, Pil-Hwon;Lee, Seon-Bong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.56-65
    • /
    • 2019
  • Recently, automobiles have been developed for safety and environmental reasons. Particularly, awareness of automobile safety is changing significantly. As a result, safety systems developed by ADAS have emerged. However, the period of mass production through ADAS development and test evaluation is long. Therefore, in this paper, we develop a brake dynamometer to shorten the time required for ADAS development and test evaluation. In addition, the developed brake dynamometer satisfies the international standard JIS D-0210, and the user can evaluate the braking force by selecting test conditions and test method for each mode of ADAS. We use the ACC, LKAS, and AEB scenarios proposed in previous studies to verify the reliability of the developed brake dynamometer. The developed brake dynamometer was verified by comparing the test values and the calculated values using theoretical formulas of the proposed ADAS mode based on previous studies. In addition, it is expected that the performance evaluation of brake parts for each ADAS mode will be possible in an environment where the vehicle test of ADAS is not possible in the future.