• 제목/요약/키워드: YBCO tape

검색결과 82건 처리시간 0.026초

BSCCO Tape 선재와 YBCO CC의 외부자장 각도에 따른 자화손실 특성비교 (Comparison of Magnetization Losses in BSCCO Tape and YBCO CC at Arbitrary Direction of External Magnetic Field)

  • 이지광;임형우;박명진;차귀수
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권12호
    • /
    • pp.586-591
    • /
    • 2005
  • Magnetization loss of high temperature superconductoring BSCCO tape and YBCO coated conductor(YBCO CC) is most important issue in the development of superconducting power devices. In this paper, the measured results of magnetization losses in BSCCO tape and YBCO CC are presented and compared with each other. Measurements of magnetization losses are performed under various angles of external magnetic field to consider the anisotropic characteristics of YBCO CC. Also, we present the compared results of magnetization losses measured at arbitrary directional magnetic fields and analyzed with perpendicular magnetic field components of those. The results show that magnetization loss of YBCO CC agree well with the analyzed value by it's perpendicular magnetic field component, but BSCCO tape is not.

Bi-2223 선재와 YBCO Coated Conductor 선재의 전송전류 손실 비교 (Transport current loss of YBCO Coated Conductor and Bi-2223 tape)

  • 임형우;이광연;차귀수;이지광;박찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1010-1012
    • /
    • 2004
  • AC loss is an important factor in the development of superconducting tapes and superconducting power applications. In this paper we measured and compared characteristics of BSCCO tape and YBCO Coated Conductor(YBCO CC). BSCCO tape was fabricated by PIT method. We measured critical current density and transport current loss of it. Also, YBCO CC tape consist of substrate. buffer, YBCO and metal layers. We measured critical current density on variations of external magnetic field and transport current loss of these cases. The results of measurement show that normalized critical current of YBCO CC is smaller then that of BSCCO tape in the external magnet field. According to the results. measured loss and calculated of the YBCO CC show the same tendency.

  • PDF

안정화 층을 갖는 YBCO Coated Conductor와 BSCCO 선재의 결합이 과전류 통전 특성에 미치는 영향 (Effect of transport current properties on connecting of YBCO Coated Conductor having stabilizer layer and BSCCO tape)

  • 김민주;두호익;임성우;박충렬;최병환;두승규;김용진;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.290-291
    • /
    • 2008
  • Recently High Temperature Superconductor(HTS) Tape is limelight of the applied superconducting machines. Mainly used superconducting tape are BSCCO tape and YBCO coated tape. These superconducting tape are applied such as SMES, superconducting generator and MAGLEV. Actually superconductor tape's experimental gauge is short. For this reason, experiment was conducted. Firstly length of 50cm BSCCO, YBCO Coated conductor@Cu and YBCO coated conductor@sus are prepared. and flow the over-current. Secondly, BSCCO and Coated conductor connected with lenth of 25cm and flow the over-current. Coupled line of HTS tape was compared with single line of HTS tape and these overcurrent characteristics was investigated.

  • PDF

YBCO Coated Conducor와 BSCCO tape의 적층 및 외부자장의 각도에 따른 자화손실 특성 (The Magnetization Losses Characteristics of Multi-stacked and Variable Angle of External Magnet Field in YBCO CC and BSCCO tape)

  • 임형우;이희준;차귀수
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권3호
    • /
    • pp.34-38
    • /
    • 2005
  • Multi-stacked HTS tapes are needed to conduct large current in the power application. In this paper, magnetization losses of the multi-stacked YBCO coated conductor and the BSCCO tape have been measured and compared. Magnetization losses of single tape, 2-stacked, 3-stacked and 4-stacked HTS tapes have been presented in this paper. Multi-stacked tapes have been fabricated using face-to-face type stacking method. Measurements of magnetization loss were performed under various angle of external magnetic field to consider the anisotropic characteristics of HTS tapes. Test results show that loss density per unit volume decreased for both YBCO coated conductors and BSCCO tapes when the stacking number of tapes is increased. The magnetization losses of YBCO CC are larger than those of BSCCO tapes when the external magnetic field is increased.

YBCO CC와 BSCCO Tape의 적층에 따른 자화손실 특성비교 (Comparison Magnetization Losses of the multi-stacked YBCO Coated conductor and the BSCCO tapes)

  • 임형우;이희준;차귀수;이지광
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권3호
    • /
    • pp.13-16
    • /
    • 2005
  • Multi-stacked HTS tapes are needed to conduct large current in the power application. In this paper magnetization losses of the multi-stacked YBCO coated conductor and the BSCCO tape have been measured and compared. Magnetization losses of single tape, 2-stacked, 3-stacked and 4-stacked HTS tapes have been presented in this paper. Multi-stacked tapes have been fabricated using face-to-face type stacking method. Measurements of magnetization loss were performed under various stacked of external magnetic field to consider the anisotropic characteristics of HTS tapes. Test results show that loss density per unit volume decreased for both YBCO coated conductors and BSCCO tapes when the stacking number of tapes is increased. As the external magnetic field decreased, the ratio of decrement has risen because the full penetration magnetic field(Bp) of the multi-stacked tape is larger than that of the single tape.

YBCO CC 적층 및 BSCCO tape 적층선재에서 수직자화 손실 값을 이용한 임의 방향 자화손실 평가 (Magnetization Loss Characteristics at Arbitrary Directional Magnetic Field by Perpendicular Magnetization Loss in YBCO CC and BSCCO Stacked Conductors)

  • 이지광;임형우;박명진;차귀수
    • 전기학회논문지
    • /
    • 제56권2호
    • /
    • pp.282-288
    • /
    • 2007
  • Magnetization loss of high temperature superconductoring BSCCO tape and YBCO coated conductor(YBCOCC) is most important issue in the development of superconducting power devices. In this paper, the measured results of magnetization losses under various angles of external magnetic field in BSCCO tape stacked conductors and YBCO CC stacked conductors are presented and compared with each other. Also, we present the compared results of magnetization losses measured at arbitrary reaction magnetic fields and analyzed with perpendicular magnetic field components of those. The results show that magnetization losses of YBCO CC single and stacked conductors agree well with the analyzed value by it's perpendicular magnetic field component, but BSCCO single and stacked conductors are not.

Output Characteristics of Linear Switched Reluctance Motor with YBCO Tape Conductors

  • Hirayama, Tadashi;Asakawa, Shinichiro;Kawabata, Shuma
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권4호
    • /
    • pp.394-398
    • /
    • 2013
  • This paper presents output characteristics of a linear switched reluctance motor (LSRM) with excitation windings wound by using high-temperature superconducting (HTS) tapes. In a double-sided LSRM, Bi-2223 or YBCO tape conductors are used for the excitation windings. The characteristics of the LSRM are obtained by a finite element method analysis. We can obtain large thrust compared with a conventional LSRM by using YBCO tape conductors. Also, the effect of a configuration of the YBCO coil on the thrust is calculated. We discuss a suitable coil configuration for the average thrust upgrading.

이중 챔버를 가진 동시증발 시스템 내에서 실린더 홀더를 이용한 18cm 길이의 YBCO coated conductor의 제작 (Fabrication of a 18cm long YBCO coated conductor using a cylindrical tape holder in a double chamber co-evaporation system)

  • 오상현;정국채;염도준
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 1999년도 High Temperature Superconductivity Vol.IX
    • /
    • pp.322-325
    • /
    • 1999
  • We fabricated 18cm YBCO coated conductor comprising a YBCO superconducting film and CeO$_2$/YSZ/CeO$_2$ buffer films deposited on a biaxially textured Ni tape. For those film fabrications, we developed a new method, the cylindrical holder in a double chamber. This is alternative to the reel-to-reef method which is commonly tried to fabricate a long YBCO coated tape. We will discuss about the superconducting properties of the 18cm long YBCO coated tapes.

  • PDF

안정화 층을 갖는 YBCO Coated Conductor와 BSCCO 선재의 결합이 과전류 통전 특성에 미치는 영향 (Effect of Transport Current Properties on Connecting of YBCO Coated Conductor having Stabilizer Layer and BSCCO Tape)

  • 두호익;김민주;박충렬;두승규;김용진;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제21권10호
    • /
    • pp.950-953
    • /
    • 2008
  • YBCO coated conductor called the second-generation superconducting tapes have resistance increase significantly more than BSCCO tapes in terms of the speed or amount when quench occurs, they may have different ranges of application. Such characteristics are thought to get different properties by selection of stabilizing materials in manufacturing superconducting tapes. It is important in selecting superconducting tapes which will be applied to power devices in the future. In this study, one kind of BSCCO tapes and two kinds of YBCO CC with different stabilizing materials and one kind of YBCO CC with non stabilizing materials were used to compare and examine transport characteristics in flux-flow state and quench state with each tape joint of HTS tapes.

HTS Nested magnet wound with 12 mm GdBCO tape and 4.4 mm YBCO tape

  • Kang, Myunghun;Ku, Myunghwan;Cha, Gueesoo;Lim, Hyoungwoo
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권2호
    • /
    • pp.50-53
    • /
    • 2015
  • The properties of High Temperature Superconducting (HTS) tapes are progressing, as HTS tapes evolve from 1st generation to 2nd generation. This paper presents design and construction of a 2nd generation HTS magnet consisting of two nested GdBCO and YBCO pancake coils. Two HTS tapes of different widths were used to wind the HTS nested magnet. Considering that a higher magnetic field is applied to the inner magnet than to the outer magnet, 12 mm GdBCO tape was used for winding the inner magnet, which consisted of four single pancake windings. Eight double pancake windings wound with 4.4 mm YBCO tapes were used for the outer magnet. The test results show that the central magnetic field of the HTS nested magnet was 920 mT. The measured critical currents of the inner and outer magnet at 77K were 80.8 A and 32.6 A, respectively.