• Title/Summary/Keyword: YAG

Search Result 1,405, Processing Time 0.031 seconds

Wear Behavior of Laser Modified SM45C Steel (레이저 표면개질된 SM45C강의 마멸거동)

  • 배춘익;옥철호;박흥식;전태옥
    • Tribology and Lubricants
    • /
    • v.16 no.1
    • /
    • pp.15-21
    • /
    • 2000
  • Radiation of Nd-YAG laser changes and refines the surface microstructure of steels, which gives rise to enhancement of hardness and resulting wear resistance. In the present work, the effect of processing parameters during the surface modification with laser on the wear behavior of the SM45C steel was studied by means of wear testing. The counter material was alumina ceramics. The microstructure observation revealed the dependence of molten depth and width on the defocusing distance. The laser modification of steel surface give rise to improved wear resistance in the testing speed range of either <0.2 m/s or >0.9 m/s Material transfer from steel was wear observated the surface of counter material when testing speed was lower than 0.7 m/s.

Distance measurement using pulsed eye-safe laser (펄스형 eye-safe 레이저를 이용한 거리측정)

  • 유병헌;조성학;장원석;김재구;황경현;이동주
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.106-109
    • /
    • 2004
  • In this project, we have developed the eye-safe LRF system of 1.54 ${\mu}{\textrm}{m}$ wavelength using OPO. The maximum measured distance was 3.7km in outdoor experiment. We used Nd:YAG (1064nm) as a laser medium. It was applied BBO to construct the system. We also developed a time-counter for the range finder using a method of TOF (time of flight). The counter-clock used at the time counter was 320MHz making resolution within $\pm$1m. Start and stop signals were detected by two channel systems using PIN and APD. The LRF's repetition rate was 4 times per minute. The energy was measured to be over 9mJ. And, pulse-duration was 23ns. Resolution was $\pm$2m at the distance measurement using a target.

  • PDF

Cerenkov type second harmonic genration in poled polymer waveguide (폴링된 폴리머 광도파로를 이용한 cerenkov형 제2고조파 생성)

  • 김응수;조원주
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.8
    • /
    • pp.62-68
    • /
    • 1998
  • Optical broadband second harmonic genration (SHG) in thin film waveguide structure was investigated. The copolymer poly(MMA-co-DR1MA) which was consiste dof PMMA (polymethylmethacrylate) and DR 1 (disperse red 1) was spin coated on the pyrex substrate. The green and near UV SHG were observe dfrom the fundamental beam even though the poled polymer has the absorption in second harmonic wavelength range. It was able to genrate SHG by cerenkov type phase matching. Th epoled polymer film thickness was decided by theoretical analysis. The green (532nm) and near UV SHG (370nm) were observed from the Q-switched Nd-YAG laser (1064nm) and Ti-sapphire laser (740nm). It was in good agreement with the experimental results.

  • PDF

Measurement of turbulent jet flow using dynamic PIV technique (Dynamic PIV를 이용한 난류 제트유동 해석)

  • Lee Sang-Joon;Jang Young-Gil;Kim Seok
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.36-39
    • /
    • 2005
  • Information on temporal evolution of whole velocity fields is essential for physical understanding of a complicated turbulent flow and was obtainable using dynamic PIV because of advances of high-speed imaging technique, laser and electronics. A dynamic PIV systme consists of a high-speed CMOS camera having $1K\times1K$ pixels resolution at 1 KHz and a high-repetition Nd:Yag pulse laser. In order to validate its performance, the dynamic PIV system was applied to a turbulent jet whose Reynolds number is about 3000. The particle images of $1024\times512$ pixels were captured at a sampling rate of 4 KHz. The dynamic PIV system measured successfully the temporal evolution of instantaneous velocity fields of the turbulent jet, from which spectral analysis of turbulent structure was also feasible.

  • PDF

Characteristics of Particle Laden Flows in Circular Microchannels (원형 마이크로채널 내의 입자가 부유된 유동의 특성)

  • Kim Y.W.;Jin S.W.;Yoo J.Y.
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.85-88
    • /
    • 2005
  • Experimental study has been conducted to evaluate characteristics of particle laden flows at the ratio of channel diameter to particle diameter (B = 14.9, 21.6 and 55). Particle velocities and radial concentrations are obtained using a microscope Nd:YAG laser and cooled CCD camera. Results show that there are relative velocities between the fluid and the particles at B = 14.9. It is also observed that the particles are accumulated at r=$0.5\∼0.82R$, with R being tile tube radius, and particle migration occurs at small Reynolds number, by comparing with the results obtained in macro scale. This gives optimal factors for designing microfluidic channels for cell or Particle separation, particle focusing, and so on.

  • PDF

Effect of Homogeneous Mixing of Sintering Additives by Coprecipitation Method on Mechanical Properties of Pressureless-Sintered $Si_3N_4$ (공침법에 의한 소결첨가제의 균일혼합이 $Si_3N_4$ 상압소결체의 기계적 특성에 미치는 영향)

  • 김지순
    • Journal of the Korean Ceramic Society
    • /
    • v.30 no.4
    • /
    • pp.265-272
    • /
    • 1993
  • Effect of mixing homogeneity in powder mixtures of Si3N4 and sintering additive (10mol% YAG) prepared by coprecipitation on the mechanical properties of pressureless-sintered body was investigated. Sintering was performed in a graphtie furnace at 1850℃ for 0.5h under 0.15MPa N2 atmosphere using Si3N4 powder bed. Results from the measurement of Young's modulus, Vickers hardness, 4-point-bending strength, and KIC for the coprecipitation-treated (CP) and the mechanically-mixed specimens(MM) showed that a remarkable improvement in flexural strength and Weibull parameter can be achieved for the CPspecimens: (677±68MPa, 12.0) for CP samples and (539±108MPa, 5.5) for MM. Other properties were almost same irrespective of preparation methods.

  • PDF

Influence of Liquid-Phase Amount on the Microstructure and Phase Transformation of Liquid-phase Sintered Silicon Carbide (액상량이 탄화규소 소결체의 미세구조 및 상변태에 미치는 영향)

  • 이종국;강현희;박종곤;이은구
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.4
    • /
    • pp.413-419
    • /
    • 1998
  • ${\beta}$-silicon carbides with yttrium aluminum garnet of 2,5,10 mol% were prepared by a liquid--phase sint-ering and the microstructural evolution and phase transformation were investigated during sintering as functions of liquid-phase amount and sintering time. The rate of grain growth decreases with the addition of the amount of yttrium aluminum garnet (YAG) in the SiC starting powder however the apparent density and the aspect ratio of grains in sintered body increase. The phase transformation from ${\beta}$-SiC to ${\alpha}$-SiC were dependent on the liquid-phase amount and sintering time.

  • PDF

Study on control of orientation of multicomponent thin film by laser ablation (레이저 어블레이션에 의한 다성분 박막의 방향성 제어 연구)

  • Park, Joo-Hyung;Lee, Sang-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1226-1228
    • /
    • 1997
  • 펄스 레이저 증착법을 이용하여 MgO 기판 위에 YBCO 박막을 c 축으로 성장시켰다. 이를 위하여 다양한 두께의 YBCO 박막을 여러 온도에서 증착시킴으로서 두께와 온도에 따른 YBCO 박막의 방향성을 조사하였다. 레이저원으로는 Nd:YAG 레이저의 355 nm의 파장을 이용하였으며, 증착시 기판온도는 $700^{\circ}C$$750^{\circ}C$에서 박막의 두께를 $3,000{\AA}$, $10,000{\AA}$, $20,000{\AA}$ 등으로 변화시켜 증착하였다. 이렇게 증착되어진 박막의 표면은 SEM으로 관촬되어졌으며, Raman Spectrascopy로 박막을 분석하였고, XRD를 사용하여 그 박막의 배향성을 연구하였다. 본 논문에서는 이와 같은 분석과 연구를 통하여 증착되어진 다성분 박막의 배향성이 기판온도와 박막두께에 따라 민감하게 변화함을 체계적으로 분석하였으며, 그 결과 기판온도와 박막 두께에 따른 YBCO 박막의 a 축, c 축 성장의 의존성을 확인하였다.

  • PDF

Cervical Esophageal Hemangioma Combined with Thyroid Cancer

  • Lee, Jong-Cheol;Kim, Jeong-Won;Lee, Yong-Jik;Lee, Seong-Rok;Park, Chang-Ryul;Jung, Jong-Pil
    • Journal of Chest Surgery
    • /
    • v.44 no.4
    • /
    • pp.311-313
    • /
    • 2011
  • Hemangiomas that arise in cervical esophagus are extremely rare, representing 3.3% of all benign esophageal tumors. Although endoscopic mucosal resection (EMR) and potassium titanyl phosphate/yttrium aluminum garnet (KTP/YAG) laser therapy have been used with success for small tumors, the safety and efficacy in the case of large tumors remains uncertain. We report the successful resection of cervical esophageal hemangioma through a cervical esophagotomy in a patient with thyroid cancer who needed a cervical collar incision.

Glass Drilling using Laser-induced Backside Wet Etching with Ultrasonic Vibration (초음파 진동과 레이저 후면 에칭을 통한 유리 구멍 가공)

  • Kim, Hye Mi;Park, Min Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.1
    • /
    • pp.75-81
    • /
    • 2014
  • Laser beam machining has been known as efficient for glass micromachining. It is usually used the ultra-short pulsed laser which is time-consuming and uneconomic process. In order to use economic and powerful long pulsed laser, indirect processing called laser-induced backside wet etching (LIBWE) is good alternative method. In this paper, micromachining of glass using Nd:YAG laser with nanosecond pulsed beam has been attempted. In order to improve shape accuracy, combined processing with magnetic stirrer has been widely used. Magnetic stirrer acts to circulate the solution and remove the bubble but it is not suitable for deep hole machining. To get better effect, ultrasonic vibration was applied for improving shape accuracy.