• Title/Summary/Keyword: Y-Stent

Search Result 472, Processing Time 0.026 seconds

Hybrid Endovascular Repair of Thoracoabdominal Aortic Aneurysm Using Visceral Debranching Technique - 2 case reports- (내장동맥 탈분지술과 혈관내 교정 하이브리드 술식으로 치료한 흉복부대동맥류 치험 - 2예 보고 -)

  • Kim, Jong-Woo;Choi, Jun-Young;Rhie, Sang-Ho;Jang, In-Seok;Sim, Hee-Jae;Shin, Tae-Beom
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.747-752
    • /
    • 2010
  • Surgical repair of thoracoabdominal aortic aneurysm (TAAA) remains a formidable challenge associated with significant rates of mortality and morbidity, especially in patients with high risk. Use of endovascular stent graff in aortic aneurysm disease is now accepted as an alternative treatment to surgery. But the saving of visceral arteries is the chief obstacle to endovascular repair of TAAA. We successfully treated two patients of TAAA with high risk by hybrid procedure including open visceral debranching and concomitant endovascular aneurysm exclusion.

Femoro-Supragenicular Popliteal Bypass with a Bridging Stent Graft in a Diffusely Diseased Distal Target Popliteal Artery: Alternative to Below-Knee Popliteal Polytetrafluoroethylene Bypass

  • Byun, Joung Hun;Kim, Tae Gyu;Song, Yun Gyu
    • Journal of Chest Surgery
    • /
    • v.50 no.5
    • /
    • pp.371-377
    • /
    • 2017
  • Background: Lesions in distal target arteries hinder surgical bypass procedures in patients with peripheral arterial occlusive disease. Methods: Between April 2012 and October 2015, 16 patients (18 limbs) with lifestyle-limiting claudication (n=12) or chronic critical limb ischemia (n=6) underwent femoral-above-knee (AK) polytetrafluoroethylene (PTFE) bypass grafts with a bridging stent graft placement between the distal target popliteal artery and the PTFE graft. Ring-supported PTFE grafts were used in all patients with no available vein for graft material. Follow-up evaluations assessed clinical symptoms, the ankle-brachial index, ultrasonographic imaging and/or computed tomography angiography, the primary patency rate, and complications. Results: All procedures were successful. The mean follow-up was 12.6 months (range, 11 to 14 months), and there were no major complications. The median baseline ankle-brachial index of 0.4 (range, 0.2 to 0.55) significantly increased to 0.8 (range, 0.5 to 1.0) at 12 months (p<0.01). The primary patency rate at 12 months was 83.3%. The presenting symptoms resolved within 2 weeks. Conclusion: In AK bypasses with a diffusely diseased distal target popliteal artery or when below-knee (BK) bypass surgery is impossible, this procedure could be clinically effective and safe when used as an alternative to femoral-BK bypass surgery.

Angiographic and Clinical Factors Related with Good Functional Outcome after Mechanical Thrombectomy in Acute Cerebral Artery Occlusion

  • Park, Jong Hyuk;Han, Young Min;Jang, Kyeong Sool;Yoon, Wan Soo;Jang, Dong Kyu;Park, Sang Kyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.3
    • /
    • pp.192-196
    • /
    • 2015
  • Objective : The aim of this study is to investigate good prognostic factors for an acute occlusion of a major cerebral artery using mechanical thrombectomy. Methods : Between January 2013 to December 2014, 37 consecutive patients with acute occlusion of a major cerebral artery treated by mechanical thrombectomy with stent retrievers were conducted. We analyzed clinical and angiographic factors retrospectively. The collateral flow and the result of recanalization were sorted by grading systems. Outcome was assessed by National Institutes of Health Stroke Scale (NIHSS) and modified Rankin Scale (mRS) at 90 days. We compared the various parameters between good and poor angiographic and clinical results. Results : Twenty seven patients demonstrated good recanalization [Thrombolysis in Cerebral Infarction (TICI) 2b or 3] after thrombectomy. At the 90-day follow up, 19 patients had good (mRS, 0-2), 14 had moderate (3-4) and four had poor outcomes (5-6). The mRS of older patients (${\geq}75years$) were poor than younger patients. Early recanalization, high Thrombolysis in Myocardial Infarction risk score, and low baseline NIHSS were closely related to 90-day mRS, whereas high TICI was related to both mRS and the decrease in the NIHSS. Conclusion : NIHSS decreased markedly only when recanalization was successful. A good mRS was related to low initial NIHSS, good collateral, and early successful recanalization.

Hemodynamic Characteristics Affecting Restenosis after Percutaneous Transluminal Coronary Angioplasty with Stenting in the Angulated Coronary Stenosis

  • Lee, Byoung-Kwon;Kwon, Hyuck-Moon;Roh, Hyung-Woon;Cho, Min-Tae;Suh, Sang-Ho
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.1 no.1
    • /
    • pp.13-23
    • /
    • 2003
  • Backgrounds: The present study in angulated coronary stenosis was to evaluate the influence of velocity and wall shear stress (WSS) on coronary atherosclerosis, the changes of hemodynamic indices following coronary stenting, as well as their effect of evolving in-stent restenosis using human in vivo hemodynamic parameters and computed simulation quantitatively and qualitatively. Methods: Initial and follow-up coronary angiographies in the patients with angulated coronary stenosis were performed (n=80). Optimal coronary stenting in angulated coronary stenosis had two models: < 50 % angle changed(model 1, n=43), > 50% angle changed group (model 2, n=37) according to percent change of vascular angle between pre- and post-intracoronary stenting. Flow-velocity wave obtained from in vivo intracoronary Doppler study data was used for in vitro numerical simulation. Spatial and temporal patterns of velocity vector and recirculation area were drawn throughout the selected segment of coronary models. WSS of pre/post-intracoronary stenting were calculated from three-dimensional computer simulation. Results: Follow-up coronary angiogram demonstrated significant difference in the percent of diameter stenosis between two groups (group 1: $40.3{\pm}30.2$ vs. group 2: $25.5{\pm}22.5%$, p<0.05). Negative WSS area on 3D simulation, which is consistent with re-circulation area of velocity vector, was noted on the inner wall of post-stenotic area before stenting. The negative WSS was disappeared after stenting. High spatial and temporal WSS before stenting fell into within physiologic WSS after stenting. This finding was prominent in Model 2 (p<0.01) Conclusions: The present study suggests that hemodynamic forces exerted by pulsatile coronary circulation termed as WSS might affect on the evolution of atherosclerosis within the angulated vascular curvature. Moreover, geometric change, such as angular difference between pre / post-intracoronary stenting might give proper information of optimal hemodynamic charateristics for vascular repair after stenting.

  • PDF

Duplex Sonography in Subclavian Steal Syndrome Treated by Stent Insertion (이중초음파검사상 빗장밑혈류빼앗김증후군이 관찰된 환자에서의 스텐트 삽입 후 추적)

  • Han, Minho
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.3
    • /
    • pp.370-374
    • /
    • 2018
  • Subclavian steal syndrome is a type of obstructive artery disease caused by severe stenosis and occlusion of a left proximal subclavian artery or brachiocephalic trunk. The resulting vertebro-basilar insufficiency symptoms are due to retrograde blood flow from the contralateral vertebral and basilar arteries into the low-pressure ipsilateral upper extremity vessels. For that reason, patients usually experience dizziness or arm ischemic symptoms. Neurointervention is an effective treatment for ischemic stroke, including the subclavian artery stenosis. This paper reports a patient with subclavian steal syndrome who had a vertebral artery Doppler waveform change in duplex sonography and a 12 mmHg difference in interarm systolic blood pressure. A stenotic lesion of the subclavian artery was treated effectively by inserting a precise stent. The follow up examination showed that the vertebral artery Doppler waveform change disappeared and recovered and that the 12 mmHg difference in interarm systolic blood pressure decreased to 5 mmHg after treatment.

Mechanical Thrombectomy with Solitaire Stent Retrieval for Acute Cardioembolic Stroke

  • Han, Hokyun;Choi, Hyunho;Cho, Keun-Tae;Kim, Byong-Cheol
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.6
    • /
    • pp.627-634
    • /
    • 2017
  • Objective : Few studies have reported the outcome of mechanical thrombectomy with Solitaire stent retrival (MTSR) in subtypes of acute ischemic stroke. The purpose of this study was to evaluate the efficacy and result of MTSR in acute cardioembolic stroke. Methods : Twenty consecutive patients with acute cardioembolic stroke were treated by MTSR. The angiographic outcome was assessed by thrombolysis in cerebral infarction (TICI) grade. TICI grade 2a, 2b, or 3 with a measurable thrombus that was retrieved was considered as a success when MTSR was performed in the site of primary vessel occlusion, and TICI grade 2b or 3 was considered as a success when final result was reported. Clinical and radiological results were compared between two groups divided on the basis of final results of MTSR. Persistent thrombus compression sign on angiogram was defined as a stenotic, tapered arterial lumen whenever temporary stenting was performed. The clinical outcomes were assessed by the modified Rankin Scale (mRS) at 3 months. Results : The failure rate of MTSR was 20% (4/20) and other modalities, such as permanent stenting, were needed. Final successful recanalization (TICI grade 2b or 3) was 80% when other treatments were included. The rate of good outcome ($mRS{\leq}2$) was 35% at the 3-month follow-up. Failure of MTSR was significantly correlated with persistent thrombus compression sign (p=0.001). Conclusion : Some cases of cardioembolic stroke are resistant to MTSR and may need other treatment modalities. Careful interpretation of angiogram may be helpful to the decision.

Hybrid Operation of a Kommerell’s Diverticulum with Left Aberrant Subclavian Artery (비정상 좌측 쇄골하동맥을 동반한 Kommerell 게실의 하이브리드 수술법)

  • Kim, Hye-Won;Lee, Jae-Won;Jung, Sung-Ho;Jung, Jae-Seung;Jung, Jong-Pil
    • Journal of Chest Surgery
    • /
    • v.43 no.4
    • /
    • pp.458-461
    • /
    • 2010
  • A 53-year-old woman had right aortic arch, Kommerell’s diverticulum and aberrant left subclavian artery (LSA) without any compressive symptoms. Hybrid operation was performed. This consisted of LSA bypass using a 6 mm ringed Gore-Tex graft between the left common carotid artery and aberrant LSA via a left supraclavicular incision, and stent graft insertion into the aortic arch via the right femoral artery. Postoperative computed tomography as well as intraoperative angiography demonstrated successful occlusion of Kommerell’s diverticulum and bypass of the aberrant LSA. There were no complications related to the operation or the intervention.

Review of National Diagnostic Reference Levels for Interventional Procedures

  • Lee, Min Young;Kwon, Jae;Ryu, Gang Woo;Kim, Ki Hoon;Nam, Hyung Woo;Kim, Kwang Pyo
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.75-88
    • /
    • 2019
  • Diagnostic reference level (DRL) is employed to optimize the radiation doses of patients. The objective of this study is to review the DRLs for interventional procedures in Korea and abroad. Literature review was performed to investigate radiation dose index and measurement methodology commonly used in DRL determination. Dose area product (DAP) and fluoroscopy time within each major procedure category were systematically abstracted and analyzed. A wide variation was found in the radiation dose. The DAP values and fluoroscopy times ranged 0.01-3,081 Gy·㎠ and 2-16,878 seconds for all the interventional procedures, 8.5-1,679 Gy·㎠ and 32-5,775 seconds for the transcatheter arterial chemoembolization (TACE), and 0.1-686 Gy·㎠ and 16-6,636 seconds for the transfemoral cerebral angiography (TFCA), respectively. The DRL values of the DAP and fluoroscopy time were 238 Gy·㎠ and 1,224 seconds for the TACE and 189 Gy·㎠ and 686 seconds for the TFCA, respectively. Generally, the DRLs of Korea were lower than those of other developed countries, except for the percutaneous transluminal angioplasty with stent in arteries of the lower extremity (LE PTA and stent), aneurysm coil embolization, and Hickman insertion procedures. The wide variation in the radiation doses of the different procedures suggests that more attention must be paid to reduce unnecessary radiation exposure from medical imaging. Furthermore, periodic nationwide survey of medical radiation exposures is necessary to optimize the patient dose for radiation protection, which will ultimately contribute to patient dose reduction and radiological safety.

A study on the dental technology and fabrication cost analysis of implant prosthesis for National Health Insurance (건강보험 급여화 관련 임플란트보철물의 기공원가 분석 연구)

  • Cho, Mi-Hyang;Lee, Gwang-Young;Lee, Hee-kyung;Nam, Shin-Eun;Ryu, Jae-Kyung;Kwon, Hyok-Mun;Kim, Kyung-Rok;Cho, Hong-Kyu
    • Journal of Technologic Dentistry
    • /
    • v.42 no.2
    • /
    • pp.149-162
    • /
    • 2020
  • Purpose: The purpose of this study was to conduct a cost accounting of implant prosthesis according to the fabrication activities. Methods: In this study, the cost price of implant prosthesis fabrication activities was calculated by the bottom-up costing approach for material and labor cost and the top-down costing approach for expenses and other. Results: The total cost price was estimated to 220,000 ~ 310,000 won per one implant prosthesis. By product, the screw type was estimated to 220,000 ~ 230,000 won, and when the stent and tray were included, it was 260,000 ~ 270,000 won, which increased about 40,000 won. And, the cement type with more material and labor time was estimated to 250,000 ~ 260,000 won, and when the stent and tray were included, it was about 300,000 won. Conclusion: In terms of the fabrication cost ratio by items, it was shown that material cost and labor cost accounted for about 40% and 30% of the total cost structure for resin case, respectively, which was the opposite for porcelain. It was shown that expenses and general administrative expenses accounted for about 15%, and profits were about 11% ~ 14% in both cases.

A Case of Locally Advanced Well-Differentiated Fetal Adenocarcinoma of the Lung Treated with Concurrent Chemoradiation Therapy

  • Kyung, Chanhee;Kim, Sang Young;Lim, Beom Jin;Cha, Jung-Joon;Kim, Hyung Jung;Ahn, Chul Min;Park, Heejin;Cho, Eun Na;Chang, Yoon Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.74 no.5
    • /
    • pp.226-230
    • /
    • 2013
  • Fetal adenocarcinoma is a rare adenocarcinoma subtype of pulmonary blastoma. A 48-year-old male patient is being referred to our hospital due to progressive dyspnea. A chest X-ray showed a lung mass of unknown origin that was obstructing the right main bronchus. After relieving the airway obstruction with stent insertion via bronchoscopy, a diagnosis of fetal adenocarcinoma is being confirmed through thoracoscopic biopsy. Due to the locally advanced state of the lung cancer, it seemed to be inoperable, and concurrent chemo-radiation therapy was being administered with docetaxel. The stent was removed after improvements in the airway obstruction followed by a lung mass shrinkage. Comparing to other contexts which describe fetal adenocarcinoma as lower grade malignancy with low-associated mortality, herein, we describe a case of locally-advanced fetal adenocarcinoma (T4N3M0). This is the first documented case being treated with concurrent chemoradiation therapy. The followed-up image studies represent a partial response and the patient is currently under further observations.