• Title/Summary/Keyword: Y needle

Search Result 3,101, Processing Time 0.033 seconds

The Clinical investigation studies in peripheral facial paralysis using Needle-Embedding Therapy (매선침법(埋線鍼法)을 이용한 구안와사 치료에 대한 임상적 고찰)

  • Kang, Eun-Kyo;Kim, Ji-Hyon;Seo, Hyeong-Sik
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.22 no.2
    • /
    • pp.118-127
    • /
    • 2009
  • Objectives : This study was performed to investigate the effect of Needle -Embedding Therapy in peripheral facial paralysis. Methods : We investigated 12 patients with peripheral facial paralysis. The patients were treated by basic oriental medicine treatment. Especially Needle-Embedding Therapy was added. We evaluated the effect of Needle-Embedding Therapy by using Yanagihara's unweighted grading system from baseline to final. Results : 1. The final Yanagihara's scores were higher than those of baseline. 2. The longer Needle Embedding Therapy period and the higher the number of the therapy repeated, the greater the effectiveness of the therapy. Conclusions : 1. Needle-Embedding Therapy was efficacious in peripheral facial paralysis. 2. Further studies will be required to identify the beneficial effect of Needle- Embedding Therapy in peripheral facial paralysis.

  • PDF

Evaluation of the Influence of Alignment Error in the Sharpness Test of a Micro-Needle (세침의 예리도 시험에서의 정렬 오차 영향 평가)

  • Lee J. K.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.05a
    • /
    • pp.250-253
    • /
    • 2004
  • Sharpness of the tip of micro needle is very Important quality that should be controlled in the manufacturing processes. Acupuncture needle is one of the most widely used micro-needle. And the tip sharpness of acupuncture needle Is usually checked by the magnitude of resisting force obtained through sharpness test. In this study, some sharpness tests of acupuncture needle were done and the relationship between the misalignment of specimen and the magnitude of resisting force. The diameter of the needle used in the test was $250\;{\mu}m$ and the length of it was 40 mm.

  • PDF

Three OOP Haptic Simulator for a Needle Biopsy (3자유도 힘반향 장치를 이용한 침생검 햅틱 시뮬레이터)

  • 권동수;경기욱;감홍식;박현욱;나종범
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.539-539
    • /
    • 2000
  • This paper shows how to implement force reflection for a needle insertion problem. The target is a needle spine biopsy simulator for tumor inspection by needle insertion. Simulated force is calculated from the relationship of volume graphic data and the orientation and Position of the needle, and it is generated using PHANTOM$^{TM}$. To generate realistic force reflection, the directional force of the needle has been generated by tissue model. The other rotational force is generated using a pivot to keep the needle in the initial inserted direction after puncturing the skin. Since the used haptic device has limitation for generating high stiffness and large damping, scale downed model and digital filter are used to stabilize the system.m.

  • PDF

Protective System from Medical Needle-sticks. Part II: Evaluation of Woven Structures and Bifid Needles

  • Seyam, Abdelfattah M.;Turner, LaDawnya C.;Banks-Lee, Pamela
    • Fibers and Polymers
    • /
    • v.4 no.3
    • /
    • pp.129-134
    • /
    • 2003
  • We have shown in Part I [1] of this study that medical needle-stick injuries are causing serious health problems to healthcare personnel and other professionals that require the attention of healthcare and textile researchers to develop new protective systems. Responding to such need, a needle force measurement device that is capable of measuring dynamic forces experienced by medical needles during needle penetration through protective articles was developed and described in part I. This paper reports the results of evaluation of protective woven fabrics from high performance fibers and standard and bifid medical needles using the force measurement system. The woven fabrics varied in cover factor, number of layers, and orientation angle. Standard and bifid needles with different gap widths were used to evaluate the resistance of the fabric to needle penetration.

Characteristics of Needle Insertion Performance of Automated Biopsy Device for Robotic Needle Insertion Type Intervention: Insertion Depth and Accuracy (로봇 자동화 바늘삽입형 중재시술을 위한 자동화 생검장치의 바늘삽입 특성: 바늘삽입 깊이 및 삽입정확도)

  • Moon, Youngjin;Choi, Jaesoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.7
    • /
    • pp.565-570
    • /
    • 2016
  • This paper presents the characteristics related to needle insertion of a robotic device for the automated biopsy procedure. The automated biopsy device, a main component of the robotic needle insertion type intervention system, allows performance of the full biopsy procedure, except for anesthesia, without direct handling of a radiologist or a tele-operated control. In this study, the needle length parameters corresponding to various insertion depths and precision for needle insertion of the automated biopsy device, are discussed. There were two combinations of needle length parameters for appropriate needle insertion and motion capture-based measurement was performed; 0.156 mm error for the 90 mm length commanded insertion displacement was measured. The pre-defined goal is a maximum 1 mm error and thus our measured error is within the acceptable range. In the repeatability check, it was also shown that the device can implement a highly accurate insertion.

Effect of Pine Needle Extract on Fe ion and Active Oxygen Related Lipid Oxidation in Oil Emulsion (Fe ion과 활성산소 관련 지방산화반응에 미치는 솔잎 추출물의 영향)

  • 김수민;조영석
    • Food Science and Preservation
    • /
    • v.6 no.1
    • /
    • pp.115-120
    • /
    • 1999
  • This study was carried out to investigate the effect of Pine needle extract on lipid oxidation and free radical reaction in iron sources reacted with active oxygen species. The results were summarized as follow; The pine needle extracts didn`t show a distinct effect on reduction of lipid oxidation if the iron ion didn`t exist in oil emulsion. The pine needle extracts played role as a strong chelating agents to bind iron ion if Ferrous iron(Fe\ulcorner) exist in oil emulsion. Ferric iron(Fe) was lower effect than Ferrous iron(Fe) on free radical reaction in oil emulsion. And also, the Fe\ulcorner reacted with pine needle extract did not show distinct effect on free radical reaction, compared to Fe\ulcorner reacted with pine needle extract. And also, Pine needle extracts reacted with H\ulcornerO\ulcorner were tended to show a low oxygen scavenging ability in case of H\ulcornerO\ulcorner only was existed, compared to those of H\ulcornerO\ulcorner + Fe\ulcorner complex. Pine needle extracts were the most powerful Fe\ulcorner binding agents, compared to other strong synthetic antioxidants such as EDTA and DTPA.

  • PDF

Coating of heat-acupuncture needle using an $Al_2O_3$ material to improve a heat insulation (한방침의 단열효과를 위한 $Al_2O_3$를 이용한 코팅연구)

  • Chung, Hyup-Jae;Rhee, Kyong-Yop
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.4
    • /
    • pp.114-119
    • /
    • 2009
  • In this research, heat-acupuncture needle was coated with $Al_2O_3$ by applying a plasma spray coating method to prevent a skin burn. $Al_2O_3$, which is one of the representative bioceramics, does not have an influence on the chemical change in the body system. The ceramic coating thickness was about $100{\mu}m$. The experiments of heat conduction were performed for uncoated needle and coated needle. The results showed that the surface temperature of needle decreased as the needle was coated with $Al_2O_3$. The surface temperature of uncoated needle was about $48^{\circ}C$, while that of needle coated with $Al_2O_3$ was about $39^{\circ}C$.

The Effect of Needle-Embedding Therapy on Peripheral Facial Paralysis (말초성 안면신경마비에 대한 매선요법 복합치료 효과)

  • Kim, Ji-Soo;Park, Soo-Yeon;Kim, Kyeong-Soo;Kim, Kyeong-Ok;Wei, Tung- Shuen;Choi, Chang-Won;Yang, Seung-Joung
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.28 no.2
    • /
    • pp.45-53
    • /
    • 2015
  • Objective : This study was performed to investigate the effect of Needle-Embedding Therapy on peripheral facial paralysis. Method : We investigated 60 cases of patients with peripheral facial paralysis, and devided patients into two groups : We treated one group by complex korean medical treatment with Needle-Embedding therapy, and did the other group by complex korean medical treatment without Needle-Embedding therapy. Yanagihara grading system at baseline and final were used for evaluating the effect of the treatment. Results : 1. In Needle-Embedding therapy group and non Needle-Embedding therapy group, compared with baseline, at final, Y score was significantly increased.2. At final, there was significant difference in improvement between Needle-Embedding therapy group and non Needle-Embedding therapy group. Conclusions : Needle-Embedding therapy seem to be effective to improve symptoms of peripheral facial paralysis. Further studies will be needed to identify the beneficial of Needle-Embedding therapy on peripheral facial paralysis.

Protective System from Medical Needle-sticks. Part I: Background and System Development

  • Turner, LaDawnya C.;Seyam, Abdelfattah M.;Banks-Lee, Pamela
    • Fibers and Polymers
    • /
    • v.4 no.2
    • /
    • pp.54-58
    • /
    • 2003
  • Previous research on healthcare workers’ protection has concentrated on liquid barrier protection by providing impermeable personal articles such as latex gloves. This property is of high importance but since most blood-borne pathogen transmissions in the healthcare industry are caused by needle-stick injuries, protection from sharp invasive instruments should also be of high concern. And since latex and alike provide no protection against needle-stick injuries, new protective systems need to be developed and evaluated. This part of the study provides a review regarding the current practice of protection and the serious problems that arise from needle-flick injuries. Additionally, the development of new protective system is described. In part II of the study, evaluation of the new system will be provided.

The Effect of Needle-embedding Therapy on the Improvement Against Facial Wrinkles: A Case Series (매선치료의 안면주름 개선효과 10례)

  • Lee, Seung-Min;Lee, Chang-Woo;Jeon, Ju-Hyun;Kim, Young-Il
    • Journal of Acupuncture Research
    • /
    • v.28 no.4
    • /
    • pp.143-147
    • /
    • 2011
  • Objectives : The purpose of this study was to examine the effect of needle-embedding therapy against facial wrinkle. Methods : Ten patients with facial wrinkles were treated with needle-embedding therapy. Pictures and satisfaction questionnaire were compared before and after the treatment. And all patients were examined for adverse side effect after needle-embedding therapy. Results : After treatment, facial wrinkles were visibly improved after needle-embedding therapy. There were no adverse side effect except bruise. Conclusions : This study suggests that needle-embedding therapy can improve facial wrinkles.