• Title/Summary/Keyword: Y Factor Method

Search Result 13,071, Processing Time 0.047 seconds

Assessment of the Stiffness factor of the Separator Plate at the Elevated Temperature (연료전지 분리판의 고온 강성 인자 연구)

  • Kim, J.H.;Woo, D.U.;Lee, S.W.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.10a
    • /
    • pp.296-299
    • /
    • 2007
  • The focus of this study is to estimate the stiffness factor of the separator plate of MCFC (Molten Carbonate Fuel Cell) at the elevated temperature. The process factors affecting the stiffness of the separator plate were chosen to determine the most important factor using the finite element analysis with the Taguchi method. The most influential factor, picked out by the ANOYA, turned out the pitch in the separator plate.

  • PDF

Fuzzy Power Factor Control Systems

  • Cho, Seong-Won;Kim, Jae-Min;Jung, Jae-Yoon;Lim, Cheol-Su
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.4 no.1
    • /
    • pp.45-49
    • /
    • 2004
  • A method for obtaining the power energy with high quality is to keep the power factor for a load as close to unity as feasible. In this paper, we present a new method to improve the power factor for a load. The proposed method uses fuzzy control techniques in order to determine how many parallel capacitors are to be connected to the load for the correction of the power factor.

Thermal Shock Stress Intensity Factor and Fracture Test (열충격 응력세기계수와 파괴실험)

  • 이강용;심관보
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.130-137
    • /
    • 1990
  • Thermal shock stress intensity factor for an edge-cracked plate subjected to thermal shock is obtained from Bueckner's weight function method. It is shown that thermal shock stress intensity factor has maximum values with variation of time and crack length and that there is most dangerous crack length. By comparing thermal shock stress intensity factor with fracture toughness, the fracture time and critical temperature difference due to thermal shock are determined theoretically. Under constant thermal shock temperature difference, and increase of crack length is shown to increase fracture time. The theoretical fracture time is compared with experimental value measured by acoustic emission method with soda lime glass.

Analysis of Deterioration Characteristics for Connection Factor according to Connection Method of Grounding System (접지시스템의 접속방식에 따른 접속요소의 열화특성 분석)

  • Gil, Hyoung-Jun;Kim, Hyang-Kon;Kim, Dong-Ook;Kim, Dong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2126-2127
    • /
    • 2011
  • This paper describes the analysis of deterioration characteristics for connection factor according to connection method of grounding system. The connection method of grounding system is specified in IEC standard. In order to analyze the deterioration characteristics for connection factor, deterioration test was carried out when the connection factor was buried in salt water and underground. The test connection factors were C-type sleeve, clamp, and exothermic welding. As a consequence, most of the connection factor was corroded, and the electrical resistance decreased after deterioration. The analytical results can be used to establish the safety of grounding system.

  • PDF

Analysis of Power Condenser Voltage Characteristics by Reactor Starting-operation (리액터 기동 운전시 콘덴서 전압 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong;Lee, Dong-Ju;Kim, Il-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.619-620
    • /
    • 2008
  • Reactor starting method has the advantage of simplicity and closed transition in spite of lower starting torque per kVA. This method allows a smooth start with almost no observable disturbance on transition and is suitable for applications such as centrifugal pumps or fans. Starting power factor is specially low. Power factor application is needed to compensate for the lower power factor of induction motor. This power factor compensation systems is being hit by the effects of the starting reactor connection position. This paper describes voltage and current stress affected by the installation position of power factor compensation application at the reactor starting method.

  • PDF

A New Control Method for The High Frequency Electronic Ballast (고주파 전자식 안정기의 새로운 제어방법)

  • Oh, Duk-Jin;Kim, Hee-Jun;Cho, Kyu-Min
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.746-749
    • /
    • 2002
  • This paper presents a new control method for the high frequency electronic ballast which is operated with raw rectified dc link using diode bridge. For the commercial electronic ballast, proper ac input power factor and crest factor of the lamp current are required. The most ballast, therefore, has a active or passive power factor collection (PFC) circuit. With the proposed method, it can be achieved simultaneously that grater than 0.9 of input power factor and less than 1.85 of lamp current crest factor without any PFC circuit. In this paper, the proposed ballast control scheme and the experimental results for the application to the fluorescent lamp are described.

  • PDF

Resonance Elastic Scattering and Interference Effects Treatments in Subgroup Method

  • Li, Yunzhao;He, Qingming;Cao, Liangzhi;Wu, Hongchun;Zu, Tiejun
    • Nuclear Engineering and Technology
    • /
    • v.48 no.2
    • /
    • pp.339-350
    • /
    • 2016
  • Based on the resonance integral (RI) tables produced by the NJOY program, the conventional subgroup method usually ignores both the resonance elastic scattering and the resonance interference effects. In this paper, on one hand, to correct the resonance elastic scattering effect, RI tables are regenerated by using the Monte Carlo code, OpenMC, which employs the Doppler broadening rejection correction method for the resonance elastic scattering. On the other hand, a fast resonance interference factor method is proposed to efficiently handle the resonance interference effect. Encouraging conclusions have been indicated by the numerical results. (1) For a hot full power pressurized water reactor fuel pin-cell, an error of about +200 percent mille could be introduced by neglecting the resonance elastic scattering effect. By contrast, the approach employed in this paper can eliminate the error. (2) The fast resonance interference factor method possesses higher precision and higher efficiency than the conventional Bondarenko iteration method. Correspondingly, if the fast resonance interference factor method proposed in this paper is employed, the $k_{inf}$ can be improved by ~100 percent mille with a speedup of about 4.56.

Database Construction to Compute Representative Model of Load Power Factor in Bulk Power System (대규모 전력계통의 부하역률 대표모델 산정을 위한 데이터베이스 구축)

  • Cho, Jong-Man;Lee, Hyo-Sang;Lee, Jung-He;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.83-89
    • /
    • 2004
  • The importance of the Load Power Factor(LPF) management is newly noticed from the voltage management and operation of the power system due to the rapidly increasing reactive power consumed. Therefore, this paper proposes the regional, seasonal and hourly Representative Model of Load Power Factor(RMLPF) considering load characteristics of all 154/22.9[kV] substations. The RMLPF is used to present a precision improvement of power system analysis and security. Computation of representative model of load utilizes the average flow method based on moving average method. The Energy Management System(EMS) data are used as the source to assess the load power factor.

Factor-analysis based questionnaire categorization method for reliability improvement of evaluation of working conditions in construction enterprises

  • Lin, Jeng-Wen;Shen, Pu Fun
    • Structural Engineering and Mechanics
    • /
    • v.51 no.6
    • /
    • pp.973-988
    • /
    • 2014
  • This paper presents a factor-analysis based questionnaire categorization method to improve the reliability of the evaluation of working conditions without influencing the completeness of the questionnaire both in Taiwanese and Chinese construction enterprises for structural engineering applications. The proposed approach springs from the AI application and expert systems in structural engineering. Questions with a similar response pattern are grouped into or categorized as one factor. Questions that form a single factor usually have higher reliability than the entire questionnaire, especially in the case when the questionnaire is complex and inconsistent. By classifying questions based on the meanings of the words used in them and the responded scores, reliability could be increased. The principle for classification was that 90% of the questions in the same classified group must satisfy the proposed classification rule and consequently the lowest one was 92%. The results show that the question classification method could improve the reliability of the questionnaires for at least 0.7. Compared to the question deletion method using SPSS, 75% of the questions left were verified the same as the results obtained by applying the classification method.

Strength Properties and Determination Method of Mix Proportion Factor of Latex Modified Concrete (라텍스개질 콘크리트의(LMC)의 강도특성 및 배합인자 결정방법)

  • Park, Sung-Ki;Won, Jong-Pil;Park, Chan-Gi
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.5
    • /
    • pp.39-50
    • /
    • 2008
  • This study are decided the mix proportion method of latex modified concrete for agricultural concrete structures from the results of workability and strength test with mix proportion factor. For mix proportion factor, this study are selected the water-cement ratio, unit cement amount and latex content. Also, this study were performed the slump, compressive strength test and microstructure analysis using the scanning electron microscope(SEM). The strength and slump of LMC are dependent with unit cement amount, latex content, and water-cement ratio. Especially, the strength of LMC are not controlled by single mix proportion factor but effected by combined mix proportion factor. Microstructure investigation are showed the LMC are reduced the internal pore volume and enhanced the transition zone between cement paste and aggregate interface. This effect get by consist of latex films in the concrete. Also, this study were recommended the mix proportion method for LMC. These mix proportions method are estimated the mix design for satisfied the target performance which are applied the agricultural concrete structure.