• Title/Summary/Keyword: XMC

Search Result 7, Processing Time 0.022 seconds

Inhibition of Cholinesterase Activity by Carbamate Insecticides (Carbamate계 살충제에 의한 Cholinesterase활성의 저해)

  • 김정호;박흥재;박병윤
    • Journal of Environmental Science International
    • /
    • v.11 no.4
    • /
    • pp.391-397
    • /
    • 2002
  • This study was carried out with the inhibition of the cholinesterase activity by carbamate insecticides in the chicken in vivo and in vitro. The optimum pH of cholinesterase was 8.0. The cholinesterase activity used the acetylcholin as substrate in plasma was 24.6 $\mu$mol/min/g protein. After oral administration with 0.32 mg/kg of BPMC as carbamate pesticide, the cholinesterase activity was inhibited to 60% of control after 15min in vivo. Then the recovery of cholinesterase activity followed to 97% of control after 12hr. I$_{50}$, such as concentration required for 50% inhibition of enzyme activity, of phenyl N-methylcarbamate were 329 $\mu\textrm{g}$/$\ell$ of XMC, 214 $\mu\textrm{g}$/$\ell$ of metolcarb, 111 $\mu\textrm{g}$/$\ell$ of BPMC, 107 $\mu\textrm{g}$/$\ell$ of propoxur and 104 $\mu\textrm{g}$/$\ell$ of isoprocarb. I$_{50}$ of aromatic N-methylcarbamate were 280 $\mu\textrm{g}$/$\ell$ of carbaryl and 114 $\mu\textrm{g}$/$\ell$ carbofuran.ran.

Design of XML message-based the heterogeneous P2P Data sharing System (XML 메시지 교환을 이용한 이기종 P2P 데이터 공유시스템 설계)

  • Jung, Hun;Kang, Byung-Wook;Seo, Yeung-Su
    • Journal of the Korea society of information convergence
    • /
    • v.1 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • If the management through the center server is unnecessary and JXTA is connected to a network, a communication with any kind of devices or some device is possible. And features that a communication with heterogeneous P2P systems is possible have. The important module of the designed Data exchange system an interworking between the P2P system which it is made we used API and the each other different protocol the possible data for replacement Data exchange system were designed this kind of a feature was to the utmost utilized may account for the XML Parser Component(XPC) which we use it parses the or about a request and the generated request, and the structure of the XML Making Component(XMC) which we use in generating the inappropriate a request and response.

  • PDF

The Reduction of the Searching Candidates for the GPS Signal Acquisition (GPS 초기 동기를 위한 탐색 후보 축소)

  • 서흥석;강설묵;이상정
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.91-107
    • /
    • 2003
  • A 2-dimensional search process in the time and frequency domain is required to acquire the GPS signal, when the code phase and the carrier Doppler for the specified GPS satellite signal are unknown. This paper proposes a new scheme, called Squared-D Searching Method, which can reduce the number of carrier frequency candidates, and a new scheme, named extended Multiple Correlator(XMC), which can reduce the number of code phase candidates. The Squared-D Searching Method can take the twice of Doppler frequency, therefore it can find carrier frequency candidates. The XMC is different from the general multiple correlator in that a combined form of the locally generated codes is used for despreading. Also, this paper tries to analyze a signal detection probability of a GPS receiver under more realistic environments. The result shows that lower detection probability can be obtained when the phase differences among the codes are larger in the correlation arms of a multiple correlator. This phenomenon is not easy to explain with the previous results. And besides, the result shows that proposed acquisition schemes give better performance than a conventional acquisition scheme.

Studies on Analytical Methods for N-Methylcarbamate Residues in Crops by Spectrophotometry and Gas Liquid Chromatography (작물체중(作物體中) N-Methylcarbamate계(系) 농약(農藥)의 잔류분석법(殘留分析法)에 관(關)한 연구(硏究))

  • Oh, Byung-Youl;Jeong, Young-Ho;Park, Young-Sun
    • Korean Journal of Environmental Agriculture
    • /
    • v.1 no.1
    • /
    • pp.14-21
    • /
    • 1982
  • Analytical methods for residues of six N-methylcarbamate insecticides were investigated to compare the minimum detectability, recovery from several crops and feasibility of multiple residue analysis. Those methods studied in this work included spectrophotometry by diazotization and gas chromatography by N-trifluoroacetylation(TFA), pentafluorobenzylether(PFB) and dinitrophenylether (DNP) derivatization. Maximum absorbed wavelength of the diazotized MIPC, XMC, BPMC, propoxur and carbofu ran was around 460 ㎚, while that of carbaryl recorded 510 ㎚. Recovery from brown rice and apple by diazotization method ranged from 80 to 120% and minimum detectable limits were 0.03 to 0.05 ppm in 50 g of the sample. Minimum detectability of PFB derivatives by gas chromatography was superior to TFA and DNP derivatives. DNP derivatives showed the longest retention time among the given derivatives. Recovery from crops by gas chromatographic met hod ranged 74 to 94%, 78 to 93%, and 85 to 99% in brown rice, rice straw and apple, respectively. Limit of detection was 0.01 ppm for TFA, 0.005 ppm for PFB and 0.02 ppm for DNP derivatives in 50 g of the crop samples.

  • PDF

Inhibition of Acetylcholinesterase Activity on the Organophosphorus and Carbamate Pesticides (유기인계 및 Carbamates 농약에 의한 Acetylcholinesterase 활성의 저해)

  • 김정호;김영호
    • Journal of Environmental Science International
    • /
    • v.7 no.1
    • /
    • pp.52-56
    • /
    • 1998
  • The effects of organophosphorus and carbamate pesticides were examined inhibition of the acetylcholinesterase activity in the chicken brain with enzyme-inhibition methods. The acetylcholinesterase activity in chicken brain determined by the Ellman method was 167 mmol/min/g protein. The optimum pH of acetycholinesterase was 8.2. $pl_{50}$ of acetycholinesterase by some organophosphorus were 3.80M of phosphorodlthioate, 4.04M of phosphorothioate, 6.33M of phosphate, and 6.60M of phosphrothiolate. pluto of acetycholinesterase by some carbamates were 5.1 OM of XMC, 5. 90M of carbofuran, 6.16M of isoprocarb, 6.30M of carbaryl, 6.47M of BPMC, and 6.77M of propoxur. pluto of carbamates selected was similar to that of phosphorothioate and phosphate organophosphates.

  • PDF

Development of low power GPS receiver

  • Kim, Il-Kyu;Lee, Jae-Ho;Seo, Hung-Serk;Park, Chan-Sik;Lee, Sang-Jeong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.114.6-114
    • /
    • 2001
  • According to expansion of wireless communication system and mobile device, interest has been growing in personal navigation system integrated with wireless system. In portable consumer electronics, such as cellular phones, GPS and PDA, one of major design factors is the power consumption. Solutions of reducing the power dissipation are low voltage, low system clock power management and so on. This paper develops a GPS receiver based on the advanced power management algorithm that achieves very low average power consumption. Both RF and DSP chips are powered down and reactivated only when the position fixing is required. In order to run, the developed includes the RTC calibration function and the fast reacquisition function using XMC (eXtended Multiple Correlator) ...

  • PDF

Data exchange Systems Design between heterogeneous P2P system that use JXTA

  • Jung, Hun;Seo, Yeung-Su;Park, Hae-Woo;Yu, Chun-Gun;Lee, Jun-Hyuk;Kang, Byung-Wook
    • 한국정보컨버전스학회:학술대회논문집
    • /
    • 2008.06a
    • /
    • pp.117-120
    • /
    • 2008
  • If the management through the center server is unnecessary and JXTA is connected to a network, a communication with any kind of devices or some device is possible. And features that a communication with heterogeneous P2P systems is possible have. The important module of the designed Data exchange system an interworking between the P2P system which it is made we used API and the each other different protocol the possible data for replacement Data exchange system were designed this kind of a feature was to the utmost utilized may account for the XML Parser Component(XPC) which we use it parses the or about a request and the generated request, and the structure of the XML Making Component(XMC) which we use in generating the inappropriate a request and response.

  • PDF