• 제목/요약/키워드: XLPE Cable

검색결과 316건 처리시간 0.035초

The Breakdown Characteristics of Interface by the Interfacial Treatment Condition of oil (이종계면에서 오일의 처리조건에 따른 절연파괴특성)

  • Cho, Han-Goo;Lee, Yu-Jung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.488-489
    • /
    • 2007
  • In this paper, We studied the properties of a cable insulate capacity between surfaces with the variation of the interfacial breakdown. Because the fault was mainly occurred in this interface. The insulate trouble of a power cable is out of the interfacial parts, which breakdown the insulate breakdown capacity in a power cable. As a function of silicon oil and interfacial roughness were investigated. In this study, the analysis of electric field and the phenomenon of interfacial breakdown were improved by increased interfacial of oil, decreased surface roughness.

  • PDF

A Study on Prediction of Treeting Breakdown in XLPE Cable According to Method of Acoustic Emission Detection (음향방출 계측법에 따른 가교폴리에틸렌 케이블의 트리잉 파괴 예지에 관한 연구)

  • 김재환;박재준
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제7권4호
    • /
    • pp.26-33
    • /
    • 1993
  • The acoustic emission automatic detection system is developed to observe tree deterioration phenomena. Applying an alternating voltage of 15(kVnns) toXLPE tree specimens, many pulses of small amplitude are detected when the bush type tree developes branch type and a few pulses of high amplitude prcxluced as branch type propagated to bush type tree. Therefore, it is known that pulses having small amplitude operates as a destructive factor. It is observed that the skewness of the amplitude and the number of average pulses as distribution tendency of three dimension are characteristic quantity of AE pulses. As the trajectory of skewness is farther from the origin on the S-plane, it is more likely to breakdown.

  • PDF

Dependence of the Partial Discharge Characteristics of Ultra-high Voltage Cable Insulators on the Measuring Temperature

  • Shin, Jong-Yeol;Park, Hee-Doo;Lee, Hyuk-Jin;Lee, Kang-Won;Kim, Won-Jong;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권5호
    • /
    • pp.186-192
    • /
    • 2008
  • Cross linked polyethylene (XLPE) insulators are used as insulation in ultra-high voltage electric power cables. This study investigated the electrical properties of XLPE at different temperatures. The electrical properties of the changing tree phenomenon was examined as a function of temperature applied to the electrical conductors by measuring the partial discharge at $25^{\circ}C$ to $80^{\circ}C$ and applied voltages to the electrodes ranging from 1 kV to 40 kV. The activity of the partial discharge was examined at various temperatures using the K-means distribution. The results revealed the specimen at $80^{\circ}C$ to have the lowest inception voltage and breakdown voltage. In addition, the core of clusters was moved $0^{\circ}$ and $180^{\circ}$ at the positive region and $180^{\circ}$ and $360^{\circ}$ in the negative region in the K-means. The distribution of clusters was concentrated on the inception condition and spread out widely at the breakdown voltage.

Analysis of Monitored Insulation Data Using Standard Deviation of Leakage Current Data in High-Power Cables at a Thermoelectric Power Station (화력발전소 고전력 케이블의 누설 전류 측정 데이터의 표준 편차값을 사용한 절연감시 데이터 분석)

  • Kim, Bo-Kyeong;Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • 제17권2호
    • /
    • pp.245-250
    • /
    • 2017
  • From the instant of installation and operation, power cables start deteriorating. Cable systems can be maintained not only by monitoring the insulation status of the insulation layer and oversheath, but also the insulation status of the terminal and junction in high-voltage power cables. When the cable system (the cable itself and cable junctions combined) deteriorates, fire accidents happen due to dielectric breakdowns. We have invented a device to monitor the deteriorating status of cables, and installed it at Korea Western Power Co. Ltd. located in Taean, Chungcheongnam-do Province. In this paper, we present the results obtained using our device, through analysing and calculating the standard deviation of leakage current from cable insulators attached to the cables. When the standard deviation of analysed leakage current falls below a critical value, a cable system is deemed to be operating safely. But when the standard deviation of analysed leakage current is larger than the critical value, the insulation status of the terminal and junction in the cable system is considered to have seriously deteriorated. The terminal and junction in the relevant system should then be replaced preemptively in order to prevent blackout accidents of cables caused by the suspension of power supply.

Influence of Radiant Heat Flux on Combustion Properties of Flame Retardant Cable (케이블의 난연성능에 따른 복사 열유속이 연소물성에 미치는 영향)

  • Mun, Sun-Yeo;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • 제33권3호
    • /
    • pp.29-36
    • /
    • 2019
  • The combustion properties required for fire simulations of multi-layer, multi-component flame retardant cables were measured using a cone calorimeter. The CO and soot yields combustion efficiencies of the flame retardant cables were investigated. TFR-8 (flame retardant PCV and XLPE added), TFR-CVV-SB (flame retardant PCV and general PVC), and VCTF, which are excellent in the flame retardancy of cables, were considered. As the main result, the CO yield (yCO) of the TFR-8 and TFR-CVV-SB flame retardant cables increased by 23% and 16%, respectively, with increasing incident radiation heat flux from 25 kW/㎡ to 50 kW/㎡. On the other hand, the CO yield of VCTF was not influenced significantly by the changes in radiant heat flux. Finally, the soot yield and combustion efficiency increased as the sheath material (flame retardant performance) was strengthened. Therefore, in a fire environment where various heat fluxes coexist, attention should be paid to the top of the application of the combustion property of the flame retardant cable.

Effects of Reclosing for Insulation Coordination in 345kV Combined Transmission Lines (345kV 혼합송전선로에서 재폐로가 절연설계에 미치는 영향)

  • Lee, Jong-Beom;Jung, Chae-Kyun;Lim, Kwang-Sik;Kang, Ji-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제59권5호
    • /
    • pp.847-853
    • /
    • 2010
  • This paper describes switching surge analysis for reclosing decision in 345kV combined transmission line with XLPE power cable. Reclosing operation should be decided based on the detailed technical analysis in combined transmission line because this line includes power cable section which is week on insulation. Insulation of power cable can be breakdown at the week point in case of reclosing moment. Therefore the detailed analysis has to be carried out by considering several conditions such as length ratio of power cable section, arrestor, inserting resistance, charging rate, grounding resistance, etc.. On the other hand sheath voltage on IJ(Insulated Joint) is analyzed to check dangerous condition on cable cover. Analysis is performed by EMTP/ATP. Analysis results show that reclosing can be operated as the single line-to-ground fault occurs on overhead line in 345kV combined transmission line, if the inserting resistance is considered before the operation of main circuit breaker.

Investigation on Electrical Tree Characteristics blended at weight of HDPE Mixed with EVA (HDPF/EVA혼합수지의 혼합 비율에 따른 전기트리특성 연구)

  • Jung, Eui-Hwan;Yoon, Jae-Hun;Lee, Seung-Su;Lim, Kee-Joe;Lee, Hung-Kyu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.264-265
    • /
    • 2009
  • In this study, each specimen blended at weight proportions of 80% HDPE to 20% EVA, 70% HDPE to 30% EVA, 60% HDPE to 40% EVA, and 50% HDPE to 50% EVA was manufactured respectively. FE-SEM analysis were carried out as auxiliary analysis means. The insulation performances of the proposed insulator were compared with conventional XLPE, main insulating material of CV cable on the basis of the investigation results of AC insulation performances.

  • PDF

Design of incident signal of time-frequency domain reflectometry in application to detect fault in a XLPE cable (XLPE 전력 케이블 결함 진단을 위한 시간-주파수 영역 반사파 계측법 기준신호 설계)

  • Jang, Seung-Jin;Lee, Sin-Ho;Lee, Chun-Ku;Park, Jin-Bae
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1870-1871
    • /
    • 2011
  • 본 논문에서는 전력케이블에서의 시간-주파수 영역 반사파 계측법을 기반으로 한 기준신호를 설계한다. 사용된 기준신호는 시간과 주파수 영역에서 동시에 분석할 수 있는 가우시안 포락선을 가지는 첩 신호이다. 10m 전력케이블의 특성에 적합하게 설계된 기준신호를 케이블에 직접 인가하여 반사파를 측정하고 정규화된 시간-주파수 영역 상호상관함수로 비교 분석하였다.

  • PDF

Filter Test for Detecting Partial Discharge in XLPE Cable (XLPE 케이블의 PD 검출 필터 시험)

  • Cho, Jae-Chul;Choi, Yong-Sung
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.218-221
    • /
    • 2008
  • Due to a variable noises in the field underground lines, clear technology of noises is very important in the diagnosis technology of partial discharge. Therefore we progressed filter test to improve the measuring test of partial discharge in a field. We applied to field test after making W-LC filter for partial discharge measurement, and then designed experimental environment such as under- ground distribution lines of field. Measuring sensor for test was UHF sensor. And we analysed those using the Lemke Probe and oscilloscope (TDS-3054, Tektro- nix). Finally, we obtained excellent data of noise decrement in the joint box of 22.9[kV] distribution lines from above experiment.

  • PDF

Title: A Characteristics of Acoustic Emission according to Treeing Deterioraction in Crosslinked Polyethylene Cable (XLPE 케이블의 트리잉 열화에 따른 음향방출 특성)

  • Cho, Dae-Yeon;Kim, Myung-Ho;Baek, Kwan-Hyun;Sim, Jong-Tak;Park, Jae-Jun;Kim, Jae-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.973-975
    • /
    • 1992
  • The Acoustic Emission due to treeing progress in Crosslinked Polyethylene(XLPE) is studied by using the self developed automatic measuring system of acoustic emission. Tree progression and average pulse amplitude are almost in proportion to the rising of applied voltage but there is no proportionality relation between tree progression and pulse numbers. From now on, Skewness and kurtosis of average cycle, special property of $\phi$-a distribution characteristics can be confirmed as the useful parameters of treeing deterioration.

  • PDF