• Title/Summary/Keyword: XANES

Search Result 44, Processing Time 0.026 seconds

Local Structure Refinement of the $BaFe_{1-x}Sn_xO_{3-y}$ System with Fe K-Edge X-Ray Absorption (XANES/EXAFS) Spectroscopy

  • 김민규;곽기섭;로권선;여철현
    • Bulletin of the Korean Chemical Society
    • /
    • v.18 no.7
    • /
    • pp.743-749
    • /
    • 1997
  • Local structure refinement of the BaFe1-xSnxO3-y system (x=0.00-0.50) has been carried out with Fe K-edge x-ray absorpion spectroscopic studies. It is found out that the Fe ions are placed in two different symmetric sites such as tetrahedral and octahedral sites in the compounds by comparison with Fe K-edge x-ray absorption near edge structure (XANES) spectrum of the γ-Fe2O3 compound as a reference. Small absorption peaks of dipole-forbiden transitions appear at a pre-edge region of 7111 eV due to the existence of Fe ions in the tetrahedral and octahedral sites. The peak intensity decreases with the substitution amount of Sn ion. Three different absorption peaks of 1s→4p dipole-allowed transition appear on the energy region between 7123 and 7131 eV. The peaks correspond to 1s→4p main transition of Fe ions in tetrahedral and octahedral sites and 1s→4p transition followed by the shakedown process of ligand to metal charge transfer. The bond distances between Fe ions in the tetrahedral site and nearest neighboring oxygen atom (Fe-4O), and those in octahedral site (Fe-6O) are determined with the extended x-ray absorption fine structure (EXAFS) analysis. Two different interatomic distances increase with the substitution amount of Sn ion and also the bond lengths of Fe-4O are shorter than those of Fe-6O in all compounds.

Chemical and Electronic structures of $Co_{1-x}Ga_x$ alloys by X-ray Analyses (X-선을 이용한 $Co_{1-x}Ga_x$ 합금계의 화학구조와 전자구조)

  • 유권국;이주열;지현배;이연승
    • Journal of the Korean Vacuum Society
    • /
    • v.13 no.2
    • /
    • pp.86-91
    • /
    • 2004
  • Transiton-metal gallides attract wide interest as a candidate for high-temperature structural materials. In a wide composition range, in which it was known that Co-Ga alloy have CsCl (B2) crystallographic structure, a systematic study on the correlation between physical properties and electronic structures of Co-gallides was performed. $Co_{l-x}Ga$ $_{x}$ alloys ($0.35\leq$x$\leq0.55$) were prepared by arc-melting method and were annealed at $1000 ^{\circ}C$ for 48hour to increase the homogeneity. In this composition range all the prepared alloys have the CsCl (B2) structure. The chemical states and the electronic structure were studied by using x-ray photoemission spectroscopy (XPS), and x-ray absorption near-edge structure (XANES), and exhibit different physical properties depending on the composition. During the annealing, a significant oxidation has happened and all the oxygen atoms are incorporated with the Ga atoms to form a $Ga_2O_3$ phase. In a view point of electronic structure, the $Co_{l-x}Ga$ $_{x}$ alloys were formed by the Ga(p) - Co(d) hybridization.

Characterization of uranium species in molten salt : An application of synchrotron-based XAFS spectroscopy

  • Cho, Young-Hwan;Choi, In-Kyu;Kim, Won-Ho
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2002.10a
    • /
    • pp.319.2-319
    • /
    • 2002
  • Synchrotron-based X-ray absorption spectroscopy has been applied to determine the changes in bulk oxidation state of uranium oxides in molten salt. From an analysis of XANES data, one can determine the cahnges in bulk oxidation-state of U compounds in salts(LiCl/KCl). XAFS spectroscpy is a powerful tool for probing the changes in valence state and structure of uranium compounds in colten salt as well as in noncrystalline form and doped in other matrices.

  • PDF

Analysis of Wide-gap Semiconductors with Superconducting XAFS Apparatus

  • Shiki, S.;Zen, N.;Matsubayashi, N.;Koike, M.;Ukibe, M.;Kitajima, Y.;Nagamachi, S.;Ohkubo, M.
    • Progress in Superconductivity
    • /
    • v.14 no.2
    • /
    • pp.99-101
    • /
    • 2012
  • Fluorescent yield X-ray absorption fine structure (XAFS) spectroscopy is useful for analyzing local structure of specific elements in matrices. We developed an XAFS apparatus with a 100-pixel superconducting tunnel junction (STJ) detector array with a high sensitivity and a high resolution for light-element dopants in wide-gap semiconductors. An STJ detector has a pixel size of $100{\mu}m$ square, and an asymmetric layer structure of Nb(300 nm)-Al(70 nm)/AlOx/Al(70 nm)-Nb(50 nm). The 100-pixel STJ array has an effective area of $1mm^2$. The XAFS apparatus with the STJ array detector was installed in BL-11A of High Energy Accelerator Research Organization, Photon Factory (KEK PF). Fluorescent X-ray spectrum for boron nitride showed that the average energy resolution of the 100-pixels is 12 eV in full width half maximum for the N-K line, and The C-K and N-K lines are separated without peak tail overlap. We analyzed the N dopant atoms implanted into 4H-SiC substrates at a dose of 300 ppm in a 200 nm-thick surface layer. From a comparison between measured X-ray Absorption Near Edge Structure (XANES) spectra and ab initio FEFF calculations, it has been revealed that the N atoms substitute for the C site of the SiC lattice.

Spatial Pattern of Copper Phosphate Precipitation Involves in Copper Accumulation and Resistance of Unsaturated Pseudomonas putida CZ1 Biofilm

  • Chen, Guangcun;Lin, Huirong;Chen, Xincai
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.12
    • /
    • pp.2116-2126
    • /
    • 2016
  • Bacterial biofilms are spatially structured communities that contain bacterial cells with a wide range of physiological states. The spatial distribution and speciation of copper in unsaturated Pseudomonas putida CZ1 biofilms that accumulated 147.0 mg copper per g dry weight were determined by transmission electron microscopy coupled with energy dispersive X-ray analysis, and micro-X-ray fluorescence microscopy coupled with micro-X-ray absorption near edge structure (micro-XANES) analysis. It was found that copper was mainly precipitated in a $75{\mu}m$ thick layer as copper phosphate in the middle of the biofilm, while there were two living cell layers in the air-biofilm and biofilm-medium interfaces, respectively, distinguished from the copper precipitation layer by two interfaces. The X-ray absorption fine structure analysis of biofilm revealed that species resembling $Cu_3(PO_4)_2$ predominated in biofilm, followed by Cu-Citrate- and Cu-Glutathione-like species. Further analysis by micro-XANES revealed that 94.4% of copper were $Cu_3(PO_4)_2$-like species in the layer next to the air interface, whereas the copper species of the layer next to the medium interface were composed by 75.4% $Cu_3(PO_4)_2$, 10.9% Cu-Citrate-like species, and 11.2% Cu-Glutathione-like species. Thereby, it was suggested that copper was initially acquired by cells in the biofilm-air interface as a citrate complex, and then transported out and bound by out membranes of cells, released from the copper-bound membranes, and finally precipitated with phosphate in the extracellular matrix of the biofilm. These results revealed a clear spatial pattern of copper precipitation in unsaturated biofilm, which was responsible for the high copper tolerance and accumulation of the biofilm.

X-Ray Absorption Spectroscopy: A Complementary Tool for Structural and Electronic Characterization of Solids

  • Jean Etourneau
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.1
    • /
    • pp.5-21
    • /
    • 1998
  • The purpose of this paper is to show that X-ray absorption spectroscopy (XANES and EXAFS) is a powerful technique for characterizing both crystalline and amorphous solids from structural (local order) and electronic point of view. The principle of this technique is briefly described by showing the main factors which must be considered for recording and fitting the experimental results. Some non-trivial examples have been selected for demonstrating that XAS spectroscopy is the only technique for bringing a definitive answer as for example: the determination of the local distortion of the $NiO_6$ octahedra in the $Li_{1-z}Ni_{1+z}O_2$ layered oxides and the evidence of the presence of copper pairs in the NASICON-type phosphate $CuZr_2 (PO_4)_3$. Are also reported some significant examples for which XAS spectroscopy is decisive with other characterization methods as (i) Raman spectroscopy for glasses (ii) Mossbauer spectroscopy for $LiNi_{1+z-t}Fe_To_2$ oxides (iii) magnetic measurements for Ce-based intermetallic compounds.

Structural Investigation of the Hydrolysis-Condensation Process of Modified Titanium Isopropoxide

  • Jung, M. W.;Oh, H. J.;Yang, J. C.;Shul, Y. G.
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.12
    • /
    • pp.1394-1398
    • /
    • 1999
  • The structures of modified Ti$(OPr^i)_4$ with chelating ligands (L) such as ethylacetoacetate (Etac), acetylacetone (Acac) and methylacetoacetate (Mtac) were identified by using IR, ¹H NMR and $^13C$ NMR spectroscopies, and the octahedral structure was confirmed after modification. The pre-edge peaks of XANES spectra of modified metal alkoxides also denoted the mixture of five-fold and six-fold structures. The EXAFS fitting results showed the local structure around Ti atom after alkoxide modification. The hydrolysis-condensation rates of modified Ti alkoxide with organic additives were investigated by ¹H NMR spectroscopy. The Ti$(OPr^i)_4$ modified by Acac was less reactive toward hydrolysis-condensation reaction than those modified by the other alkoxides, which can be attributed to the stable ligand structure between Ti$(OPr^i)_4$ and Acac. The small particle size of modified Ti$(OPr^i)_4$ sol was obtained when Acac was employed.

Mn K-Edge XAS Analyses of $Zn_{2-x}Mn_xSiO_4$ Phosphors ($Zn_{2-x}Mn_xSiO_4$ 형광체의 망간 K 흡수단 엑스선 흡수 분광 분석)

  • Choi, Yong Gyu;Lim, Dong Sung;Kim, Kyong Hon;Sohn, Kee Sun;Park, Hee Dong
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.6
    • /
    • pp.636-643
    • /
    • 1999
  • Green-emission intensity of a $Zn_{2-x}Mn_xSiO_4$ phosphor, which is a potential candidate as a green component in PDP device, significantly increases provided that the compound is additionally heat treated at 900$^{\circ}C$ after solid state reaction at 1300$^{\circ}C$. In order to verify origin of such an intensity enhancement after the additional heat treatment in association with the electronic and local structural change at around Mn ions, the Mn K-edge X-ray absorption spectra were recorded. From the analyses of the preedge peak corresponding to $1s{\rightarrow}3d$ bound state transition and XANES spectrum, it is known that most Mn ions are in +2 oxidation state and substitute Zn ion site regardless of the thermal treatment. In addition, EXAFS analyses revealed that Mn ions formed $MnO_4$ tetrahedra with the Mn-O bond length shortened by 0.01${\AA}$ and with reduced Debye-Waller factor in the thermally treated sample.

  • PDF

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF