• Title/Summary/Keyword: XA 영상

Search Result 4, Processing Time 0.019 seconds

Rapid Rigid Registration Method Between Intra-Operative 2D XA and Pre-operative 3D CTA Images (수술 중 촬영된 2D XA 영상과 수술 전 촬영된 3D CTA 영상의 고속 강체 정합 기법)

  • Park, Taeyong;Shin, Yongbin;Lim, Sunhye;Lee, Jeongjin
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.12
    • /
    • pp.1454-1464
    • /
    • 2013
  • In this paper, we propose a rapid rigid registration method for the fusion visualization of intra-operative 2D XA and pre-operative 3D CTA images. In this paper, we propose a global movement estimation based on a trilateration for the fast and robust initial registration. In addition, the principal axis of each image is generated and aligned, and the bounding box of the vascular shape is compared for more accurate initial registration. For the fine registration, two images are registered where the distance between two vascular structures is minimized by selective distance measure. In the experiment, we evaluate a speed, accuracy and robustness using five patients' data by comparing the previous registration method. Our proposed method shows that two volumes can be registered at optimal location rapidly, and robustly comparing with the previous method.

Medical image control process improvement based on Cardiac PACS (Cardiac PACS 구축에 따른 의료영상 관리 프로세스 개선)

  • Jung, Young-Tae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.1
    • /
    • pp.35-42
    • /
    • 2014
  • Heart related special images are classified as Cardiac US, XA, CT, MRI. Several Problem is caused by image compression, control and medical support point, so most big hospitals have created a Cadiac PACS differentially in past years. For this reason, create a conflict in inner colleague and patient, protector that result from 2 data processing server operating independently in 1 medical center area. For this reason, we sugges an alternative model of best medical control process together with understand the current situation on medical facility.

  • PDF

Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT

  • Jeong, Dae-Kyo;Lee, Sang-Chul;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.42 no.2
    • /
    • pp.65-70
    • /
    • 2012
  • Purpose : The aim of this study was to compare the effective dose for imaging of mandible between multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). An MDCT with low dose technique was also compared with them. Materials and Methods : Thermoluminescent dosimeter (TLD) chips were placed at 25 organ sites of an anthropomorphic phantom. The mandible of the phantom was exposed using 2 different types of MDCT units (Somatom Sensation 10 for standard-dose MDCT, Somatom Emotion 6 for low-dose MDCT) and 3 different CBCT units (AZ3000CT, Implagraphy, and Kavo 3D eXaM). The radiation absorbed dose was measured and the effective dose was calculated according to the ICRP 2007 report. Results : The effective dose was the highest for Somatom Sensation 10 (425.84 ${\mu}Sv$), followed by AZ3000CT (332.4 ${\mu}Sv$), Somatom Emotion 6 (199.38 ${\mu}Sv$), and 3D eXaM (111.6 ${\mu}Sv$); it was the lowest for Implagraphy (83.09 ${\mu}Sv$). The CBCT showed significant variation in dose level with different device. Conclusion : The effective doses of MDCTs were not significantly different from those of CBCTs for imaging of mandible. The effective dose of MDCT could be markedly decreased by using the low-dose technique.

Comparison of Noise Power Spectrum Methodologies in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료시 전자포털영상장치를 이용한 잡음전력스펙트럼 방법론 측정비교)

  • Son, Soon-Yong;Choi, Kwan-Woo;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.99-105
    • /
    • 2016
  • The noise power spectrum (NPS) is one of the most general methods for measuring the noise amplitude and the quality of an image acquired from a uniform radiation field. The purpose of this study was to compare different NPS methodologies by using megavoltage X-ray energies. The NPS evaluation methods in diagnostic radiation were applied to therapy using the International Electro-technical Commission standard (IEC 62220-1). Various radiation therapy (RT) devices such as TrueBeam$^{TM}$(Varian), BEAMVIEW$^{PLUS}$(Siemens), iViewGT(Elekta) and Clinac$^R$ iX (Varian) were used. In order to measure the region of interest (ROI) of the NPS, we used the following four factors: the overlapping impact, the non-overlapping impact, the flatness and penumbra. As for NPS results, iViewGT(Elekta) had the higher amplitude of noise, compared to BEAMVIEW$^{PLUS}$ (Siemens), TrueBeam$^{TM}$(Varian) flattening filter, Clinac$^{R}$iXaS1000(Varian) and TrueBeam$^{TM}$(Varian) flattening filter free. The present study revealed that various factors could be employed to produce megavoltage imaging (MVI) of the NPS and as a baseline standard for NPS methodologies control in MVI.