• Title/Summary/Keyword: X-ray unit

Search Result 561, Processing Time 0.032 seconds

Result of Radiation Therapy for the Lung Cancer (폐암의 방사선치료 결과)

  • Kim Joo-Young;Choi Myung-Sun;Suh Won-Hyck
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.213-225
    • /
    • 1989
  • An analysis has been made of two hundred seven patients who were treated at the department of Radiation Oncology of Korea University Hospital for lung cancer from January 1981 through December 1986. There were 137 patients of nonsmall cell carcinoma (137/207, 66%), 26 patients of small cell carcinoma (26/207, 12.5%) and 44 patients of unproven histology. By aims of treatment, there were 104 patients (104/207, 50%) treated for cure, 89 patients (89/207, 42.9%) for palliation and 14 patients treated postoperatively. In 22 out of 207 patients, chemotherapy was done with radiotherapy, 12 of which were patients with small cell carcinoma. Stage II patients were 49 (49/207, 23.6%), stage III patients were 157 (157/207, 75.8%) and one patient had an occult cancer The tumor was initial Iy measured by CAT scan and chest X-rays in the 165 (165/207, 79.7%) patients, among which 117 patients had tumor diameter more than 5cm and 48 patients less than 5cm. Radiation therapy was given with Cobalt 60 teletherapy unit and the treatment volume encompassed primary tumor and the mediastinum. For curative aim, daily tumor dose of 180 cGy was given up to the range of 5,400~6,120cGy/30~34F/6~7 week period and for palliative aim, daily tumor dose of 300 cGy was given up to the range of 3,600~4,500 cGy/12~15F/2~3 week period. Postoperatively, mediastinum was treated for total dose of 5,040 cGy/28F/5.5 week period. 123 patients (123/207, 59%) were followed up after completion of radiotherapy for 14 months to 7 years. Local tumor response to the irradiation was measured by chest X-ray taken at one month follow up and was evaluated for response rate, if they were regressed more than 50% or less than 50% of the initial tumor size. The treatment results were as follows; 1. The median survival time was 8.5 months and survival rates for 1 year, 2 year and 5 year was 25%, 3.5% and 1% of nonsmall cell lung ca of 74 evaluable patients. 2. More than 50% of local tumor response rate was obtained in about half of overall cases; 90.5% for small cell ca, 50% for squamous cell ca, 25% for adenoca and 57% for large cell ca. 3. Response rate more than 50% was seen in the 50% of the patient group with tumor diameter more than 5cm and in the 55% of those with tumor diameter less than 5cm. 4. By total raidation dose given, patient group which was given 5,400~6,120 cGy equivalent dose or higher showed tumor response rate more than 50% in 53% of the patients, whereas the group with dose less than 5,400cGy equivalent, in 25% of the patients. 5. Survival rate for 6 month, 1 year and 2 year was compared between the group of local tumor response rate more than 50% vs. group with response rate less than 50%; 74% vs. 43%, 33% vs, 23%, 10% vs. 1%, respectively. 6. Local failure was seen in 21%(44/207) of the patients, which occured mostly within 15 months after completion of radiation therapy. Distant metastases were seen in 49.7%(103/207) of the patients, of which 43 cases were found before initiation of radiotherapy. The most common metastatic sites were bone and brain. In this sutdy, 1 year,2 year and S year survival rates were somewhat poor compared to the other studies. It mainly seems to be due to the poor general status of the patients and the far-advanced stage of the disease. In nonsmall cell cancer patients who had limited local disease and had small primary tumor size, we observed better local response. In addition, dose higher than 6,000 cGy group showed better tumor control than lower dose group. Survival rate was better for the local control group. For imporvement of local control of the lung cancer and hence, the survival of the patients with lung cancer, proper radical radiotherapy with high dose for localized disease is needed. New modality of treatment such as high LET beam in radiation therapy or drugs for the advanced disease as well as early diagnosis is also needed.

  • PDF

A Clinical Study on Transpulmonary Leukostasis and Prophylactic Effects of Steroid in Cardiac Surgery (심장수술시 백혈구의 폐내정체와 스테로이드의 예방적 효과에 관한 연구)

  • 최석철
    • Biomedical Science Letters
    • /
    • v.2 no.2
    • /
    • pp.133-151
    • /
    • 1996
  • After cardiac surgery, it has been recognized that various complications were associated with injured humoral and cellular immunity by cardiopulmonary bypass(CPB). Especially, in postoperative pulmonary dysfunction, transpulmonary leukostasis followed complement activation and inflammatory responses are major pathogen. Some studies have showed that pretreated-corticosteroids before CPB protected postoperative pulmonary dysfunction. Corticosteroids may inhibit complement and leukocyte activation. On based previous studies, present investigator determined changes of leukocyte counts and transpulmonary leukostasis during cardiac surgery and postoperative periods. For the evaluation of postoperative pulmonary function and edema, $PaO_2$ and chest X-ray were compared between pre-CPB and post-CPB. Fever and other parameters were also observed postoperatively. The aim of this study was to define for the prophylactic effects of corticosteroid(Solu-Medrol: 30mg/kg) on all the researched parameters. This study was prospectively designed with randomized-blind fashion for 50 patients undergoing cardiac surgery. According to the purpose of study, all patients were divided into placebo and steroid group. : Placebo group was 25 patients received normal saline(not corticosteroid), and steroid group was 25patients received corticosteroid(Solu-Medrol: 30mg/kg) before initiation of CPB. The results of study were summarized as follows. 1. Total peripheral leukocyte counts decreased significantly at 5 minutes of CPB in all patients(P<0.01), and began to increase progressively at later periods of CPB with neutrophilia. The significant rise remained at postoperative 7th day(P<0.05). 2. During partial CPB, transpulmonary leukostasis occurred in placebo group(P<0.001), whereas it was prevented in steroid group. 3. In both groups, peripheral lymphocyte counts were stable during CPB, but began to reduce at time of intensive care unit(ICU) and the lymphocytopenia remained until postoperative 3rd day. The lymphocyte counts recovered on postoperative 7th day. 4. In both groups, peripheral counts of monocyte were relatively stable in the early peroid of CPB, and increased gradually in the later periods of CPB. This significant monocytosis remained throughout postoperlative periods(P<0.05). 5. The mean value of postoperative $paO)_2$ was lower than that of pre-CPB in placebo group(P=0.01) but didn't significant in steroid group(P=0.90). In the incidence of pulmonary edema signs and fever, placebo group was higher than steroid group(P=0.001, p=0.01, respectively). However mechanical respiratory supporting and care periods at intensive care unit were not significant difference between two groups(P>.0.05).With the above results, the investigator concluded that leukocyte activation and pulmonary sequestration were caused by cardiac surgery with CPB and demonstrated that high dose corticosteroid will provide prophylactic effect for pulmonary leukostasis and higher neutrophilia. These effects may ameliorate postoperative pulmonary dysfunction and contribute to postoperative less morbidity. However, further study should be performed because postoperative lymphocytopenia continued for 3 days in both groups, which may suspected damage or suppression of cell-mediated immunity with used corticosteroid.

  • PDF

GPU Based Feature Profile Simulation for Deep Contact Hole Etching in Fluorocarbon Plasma

  • Im, Yeon-Ho;Chang, Won-Seok;Choi, Kwang-Sung;Yu, Dong-Hun;Cho, Deog-Gyun;Yook, Yeong-Geun;Chun, Poo-Reum;Lee, Se-A;Kim, Jin-Tae;Kwon, Deuk-Chul;Yoon, Jung-Sik;Kim3, Dae-Woong;You, Shin-Jae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.80-81
    • /
    • 2012
  • Recently, one of the critical issues in the etching processes of the nanoscale devices is to achieve ultra-high aspect ratio contact (UHARC) profile without anomalous behaviors such as sidewall bowing, and twisting profile. To achieve this goal, the fluorocarbon plasmas with major advantage of the sidewall passivation have been used commonly with numerous additives to obtain the ideal etch profiles. However, they still suffer from formidable challenges such as tight limits of sidewall bowing and controlling the randomly distorted features in nanoscale etching profile. Furthermore, the absence of the available plasma simulation tools has made it difficult to develop revolutionary technologies to overcome these process limitations, including novel plasma chemistries, and plasma sources. As an effort to address these issues, we performed a fluorocarbon surface kinetic modeling based on the experimental plasma diagnostic data for silicon dioxide etching process under inductively coupled C4F6/Ar/O2 plasmas. For this work, the SiO2 etch rates were investigated with bulk plasma diagnostics tools such as Langmuir probe, cutoff probe and Quadruple Mass Spectrometer (QMS). The surface chemistries of the etched samples were measured by X-ray Photoelectron Spectrometer. To measure plasma parameters, the self-cleaned RF Langmuir probe was used for polymer deposition environment on the probe tip and double-checked by the cutoff probe which was known to be a precise plasma diagnostic tool for the electron density measurement. In addition, neutral and ion fluxes from bulk plasma were monitored with appearance methods using QMS signal. Based on these experimental data, we proposed a phenomenological, and realistic two-layer surface reaction model of SiO2 etch process under the overlying polymer passivation layer, considering material balance of deposition and etching through steady-state fluorocarbon layer. The predicted surface reaction modeling results showed good agreement with the experimental data. With the above studies of plasma surface reaction, we have developed a 3D topography simulator using the multi-layer level set algorithm and new memory saving technique, which is suitable in 3D UHARC etch simulation. Ballistic transports of neutral and ion species inside feature profile was considered by deterministic and Monte Carlo methods, respectively. In case of ultra-high aspect ratio contact hole etching, it is already well-known that the huge computational burden is required for realistic consideration of these ballistic transports. To address this issue, the related computational codes were efficiently parallelized for GPU (Graphic Processing Unit) computing, so that the total computation time could be improved more than few hundred times compared to the serial version. Finally, the 3D topography simulator was integrated with ballistic transport module and etch reaction model. Realistic etch-profile simulations with consideration of the sidewall polymer passivation layer were demonstrated.

  • PDF

Evaluation of Image Quality & Absorbed Dose using MCNPX Simulation in the Digital Radiography System (디지털방사선영상시스템에서 MCNPX 시뮬레이션을 이용한 영상 품질 및 선량평가)

  • An, Hyeon;Lee, Dongyeon;Ko, Sungjin;Kim, Changsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.327-335
    • /
    • 2016
  • The study is enforce to study image quality evaluation of condition provide the IEC and combination of clinical conditions each quality of radiation that image quality to assess the conditions provided to IEC in the clinical environment to conduct image quality assessment of the digital radiography system in the detector have environmental limits. First, image quality evaluation was evaluated by measuring the MTF, NPS using four quality of radiation and Using MCNPX simulation lastly DQE make a image quality evaluation after calculating the particle fluence to analyze spectrum quality of radiation. Second, Using MCNPX simulation of four quality of radiation was evaluated absorbed dose rate about electronic 1 per unit air, water, muscle, bone by using Radiation flux density and energy, mass-energy absorption coefficient of matter. Results of evaluation of image quality, MTF of four quality of radiation was satisfied diagnosis frequency domain 1.0 ~ 3.0 lp/mm of general X-ray that indicated 1.13 ~ 2.91 lp/mm spatial frequency. The NPS has added filter, spatial frequency 0.5 lp/mm at standard NPS showed a tendency to decrease after increase. Unused added filter, spatial frequency 0.5 lp/mm at standard NPS showed a certain NPS result value after decrease. DQE in 70 kVp / unuesd added filter(21 mm Al) / SID 150 cm that patial frequency 1.5 lp/mm at standard showed a tendency to decrease after certain value showed. Patial frequency in the rest quality of radiation was showed a tendency to decrease after increase. Results of evaluation of absorbed dose, air < water < muscle < bone in the order showed a tendency to increase. Based on the results of this study provide to basic data that present for the image quality evaluation method of a digital radiation imaging system in various the clinical condition.

Results of Radiotherapy for the Uterine Cervical Cancer (자궁경부암의 방사선치료성적)

  • Kim, Chul-Yong;Choi, Myung-Sun;Suh, Won-Hyuck
    • Radiation Oncology Journal
    • /
    • v.6 no.1
    • /
    • pp.63-73
    • /
    • 1988
  • One hundred fifty-four patients with the carcinoma of the uterine cervix were studied retrospectively to assess the result and impact of treatment at Department of Radiation Oncology, Korea University, Hae-Wha Hospital from Feb 1981 through Dec. 1986. Prior to radiotherapy, the patients were evaluated and staged by recommendation of FIGO including physical examination, pelvic examination, cystoscopy, rectosigmoidoscopy, chest X-ray, IVP. Ba enema. Also, an additional pelvic CT scan was obtained for some of the patients. The patients were treated by radiotherapy alone or adjuvant postoperative irradiation; in case of radiation therapy only, whole pelvic irradiation was given with Co-60 teletherapy unit via AP and PA parallel opposing fields or 4-oblique fields, 180 cGy per day, 5 days per week and intracavitary insertion was performed. In satges Ia, Ib, and IIa with small primary lesion, external irradiation was initially given to pelvis up to $2,000\~3,000\;cGy/2frac{1}{2}\;-3frac{1}{2}$ weeks and then intracavitary insertion was performed using Fletcher-Mini-Declos Applicator with cesium-137 cources and followed by external irradiation of $1,000\~2,000\;cGy/1frac{1}{2}\;-2frac{1}{2}$weeks via AP and PA parallel opposing fields with midline shield to spare of bladder and rectum. However, if the primary lesion is large, external irradiation was given without midline shield. More than stages IIb, the patients were treated by external beam irradiation up to 5,400cGy/30f for 6 weeks via 4-oblique portals and at the dose of 5,040cGy/28f the field was cut 5cm from the top margin for spare of small bowel, and followed by intracavitary irradiation, If there was residual tumor an additional dose of $900\~l,200cGy/5\~7f$ was given to parametrium and/or residual tumor area. Total dose of radiation to A and B-point were as follows; A-point; In early stages, Ia, Ib, IIa; $8,000\~9,000$ B-point $5,000\~6,000 cGy$ A-point; In advanced stages IIb, IIIa, IIIb; $9,000\~10,000$ B-point $60,000\~7,000cGy$ The results were obtained and as fellows; 1 The patients distribution according to FIGO staging system were stage Ia 6, Ib 27, IIa 28, IIb 54, IIIa 12, IIIb 18, and stage IVa 9. 2. Value of CT scan were demonstration of cervix tumor mass, parametrial and pelvic side wall tumor spread, pelvic and inguinal lymph nodes metastases, and hydronephrosis. Three dimensional quantitative demonstration of tumor volume is also important in planning radiation therapy. Another advantage of CT scan was detection of recurrent tumor after radiation or surgery. 3. Local control rate of tumor according to the size was $91.3\%$ for less than 5cm in size and $44.6\%$ in tumor over 5cm (p<0.0068). 4. Thirty out of 50 recurrent sites has locoregional failures and 17 cases has distant metastases. And the para-aortic lymph nodes were the most common site for distant metastases. 5. The most common complication was temporal rectal bleeding which was controlled most by conservative management. However, 4 patients required for endoscopic cauterization. 6. The 5-year survival rates showed; stage la and Ib $95\%,\;stage\;IIa\;81\%\;stage\;lIb\;67\%,\;stage\;IIIa\;37.7\%,\;stage\;IIIb\;23\%$ and 3-year survival rate of stage IVa showed $11.6%$, retrospectively.

  • PDF

Study on the Various Size Dependence of Ionization Chamber in IMRT Measurement to Improve Dose-accuracy (세기조절 방사선치료(IMRT)의 환자 정도관리에서 다양한 이온전리함 볼륨이 정확도에 미치는 영향)

  • Kim, Sun-Young;Lee, Doo-Hyun;Cho, Jung-Keun;Jung, Do-Hyeung;Kim, Ho-Sick;Choi, Gye-Sook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • Purpose: IMRT quality assurance(Q.A) is consist of the absolute dosimetry using ionization chamber and relative dosimetry using the film. We have in general used 0.015 cc ionization chamber, because small size and measure the point dose. But this ionization chamber is too small to give an accurate measurement value. In this study, we have examined the degree of calculated to measured dose difference in intensity modulated radiotherapy(IMRT) based on the observed/expected ratio using various kinds of ion chambers, which were used for absolute dosimetry. Materials and Methods: we peformed the 6 cases of IMRT sliding-window method for head and neck cases. Radiation was delivered by using a Clinac 21EX unit(Varian, USA) generating a 6 MV x-ray beam, which is equipped with an integrated multileaf collimator. The dose rate for IMRT treatment is set to 300 MU/min. The ion chamber was located 5cm below the surface of phantom giving 100cm as a source-axis distance(SAD). The various types of ion chambers were used including 0.015cc(pin point type 31014, PTW. Germany), 0.125 cc(micro type 31002, PTW, Germany) and 0.6 cc(famer type 30002, PTW, Germany). The measurement point was carefully chosen to be located at low-gradient area. Results: The experimental results show that the average differences between plan value and measured value are ${\pm}0.91%$ for 0.015 cc pin point chamber, ${\pm}0.52%$ for 0.125 cc micro type chamber and ${\pm}0.76%$ for farmer type 0.6cc chamber. The 0.125 cc micro type chamber is appropriate size for dose measure in IMRT. Conclusion: IMRT Q.A is the important procedure. Based on the various types of ion chamber measurements, we have demonstrated that the dose discrepancy between calculated dose distribution and measured dose distribution for IMRT plans is dependent on the size of ion chambers. The reason is small size ionization chamber have the high signal-to-noise ratio and big size ionization chamber is not located accurate measurement point. Therefore our results suggest the 0.125 cc farmer type chamber is appropriate size for dose measure in IMRT.

  • PDF

Tuberculosis in Infants (영아의 결핵)

  • Kim, Ee-Kyung;Nah, Song-Yi;Park, Jin-Young;Choi, Eun-Hwa;Lee, Hoan-Jong
    • Pediatric Infection and Vaccine
    • /
    • v.5 no.1
    • /
    • pp.69-78
    • /
    • 1998
  • Purpose : The risk of severe tuberculous disease such as meningitis or miliary tuberculosis increases as younger is the child at the time of infection. Therefore, the early diagnosis and prompt treatment is mandatory for infants with tuberculosis. This study was undertaken to describe the epidemiology, clinical and radiographic manifestations, and response to therapy in infants with tuberculous disease. Methods : Medical records of 29 infants with tuberculosis diagnosed at the Seoul National University Children's Hospital from July, 1985, to April, 1997, were reviewed, retrospectively. A case of tuberculosis was confirmed if M. tuberculosis was isolated from any body site or if there was histologic proof of tuberculosis. Otherwise, the diagnoses were individualized considering history of contact with contagious adult case, clinical manifestations, chest X-ray findings, result of a Mantoux test reaction with 5 tuberculin unit of PPD, and the response to therapy. Results : The mean age at diagnosis was $7.00{\pm}2.65$ months (range, 3 to 12 months). Twelve cases had isolated pulmonary diseases, and the rest had pulmonary disease and meningitis, 5 cases; pulmonary disease and cervical lymphadenitis, 3; isolated meningitis, 3; and miliary tuberculosis, 6. Source case was identified in 19 cases, 7 of which were detected with retrograde manner. Twenty seven of 29 were symptomatic at their initial visit. The presenting symptoms were mainly respiratory or neurologic, and respiratory difficulty was accompanied in 7 cases. Physical examination revealed wheezing in 7 cases and decreased breath sounds in 9. Hepatomegaly or hepatosplenomegaly were frequent. Chest radiographs showed lung parenchymal disease with hilar lymphadenopathy in 18 cases, and focal or generalized emphysematous change in 7 cases. Conclusion : Most of the infants with tuberculosis are symptomatic at diagnosis, and many of infants with intrathoracic tuberculosis presented with symptoms of bronchial obstruction. When tuberculosis is suspected in an infant, the adult source case should be vigorously investigated to aid in diagnosis and for the prevention of further transmission of tuberculous disease. Almost half of infant tuberculosis are preventable if prophylaxis were given when adult cases were diagnosed.

  • PDF

DETECTION OF METHICILLIN OR VANCOMYCIN-RESISTANT STAPHYLOCOCCUS AUREUS FROM DENTAL HOSPITAL (치과병원 진료실 내에서 메티실린 또는 반코마이신 저항성 Staphylococcus aureus의 검출)

  • Min, Jung-Hee;Park, Soon-Nang;Hwang, Ho-Keel;Min, Jung-Beum;Kim, Hwa-Sook;Kook, Joong-ki
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.2
    • /
    • pp.102-110
    • /
    • 2007
  • The purpose of this study was to obtain the basic information for the improvement of dental environment by investigating the presence of methicillin- or vancomycin-resistant Staphylococcus aureus (MRSA or VRSA) isolated from dental health care workers (DHCWs) and environment of the Chosun University Dental Hospital (CUDH) and a private dental clinic (control group). Staphylococcus aureus (S. aureus) was isolated from anterior nares of 42 DHCWS and 38 sites, unit chairss, x-ray devices, computers, etc., at 10 departments of the CUDH and 20 DHCWs and 11 sites at the private dental clinic. S. aureus was isolated on mannitol salt agar plate and confirmed by PCR with S. aureus species-specific primer. Antimicrobial susceptibility test of clinical isolates of S. aureus against several antibiotics including methicillin (oxacillin) was performed by investigating minimum inhibitory concentration (MIC) using broth microdilution assay. In addition, PCR was performed to detect the methicillin- or vancomycin-resistant gene. The data showed that one strain of S. aureus was isolated from DHCWs of the CUDH and three strains of S. aureus was isolated from 3 samples of the private dental clinic, respectively. All of the isolates from the CUDH and the private dental clinic had resistance to penicillin G, amoxicillin and vancomycin and susceptibility to oxacillin and ciprofloxacin. The S. aureus strains were already obtained the resistance to penicillin G and amoxicillin. These results suggest that two dental clinics were under relatively safe environment.

THE EFFECT OF LOW DIETARY CALCIUM AND IRRADIATION ON MANDIBLE IN RATS (저칼슘식이와 방사선조사가 백서 악골에 미치는 영향의 실험적 연구)

  • Lee Sun-Ki;Lee Sang-Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.23 no.2
    • /
    • pp.229-250
    • /
    • 1993
  • This study was performed to investigate the morphological and structural changes of bone tissues and the effects of irradiation on the mandibular bodies of rats which were fed low calcium diets. In order to carry out this experiment, 160 seven-week old Sprague-Dawley strain rats weighing about 150 gm were selected and equally divided into one normal diet group of 80 rats and one low calcium diet group with the remainder. These groups were then subdivided into two groups, 40 were assigned rats for each subdivided group, exposed to radiation. The Group 1 was composed of forty non-irradiated rats with normal diet, Group 2 of forty irradiated rats with normal diet, Group 3 forty non-irradiated rats with low calcium diet, and Group 4 forty irradiated rats with low calcium diet. The two irradiation groups received a single dose of 20 Gy on the jaw area only and irradiated with a cobalt-50 teletherapy unit. The rats with normal and low calcium diet groups were serially terminated by ten on the 3rd, the 7th, the 14th, and the 21st day after irradiation. After termination, both sides of the dead rats mandible were removed and fixed with 10% neutral formalin. The bone density of mandibular body was measured by use of bone mineral densitometer(Model DPX -alpha, Lunar Corp., U.SA). Triga Mark ill nuclear reactor in Korea Atomic Research Institute was used for neutron activation and then calcium contents of mandibular body were measured by using a 4096 multichannel analyzer (EG and G ORTEC 919 MCA, U.SA). Also the mandibular body was radiographed with a soft X-ray apparatus(Hitex Co., Ltd., Japan). Thereafter, the obtained microradiograms were observed by a light microscope and were used for the morphometric analysis using a image analyzer(Leco 2001 System, Leco Co., Canada). The morphometric analysis was performed for parameters such as the total area, the bone area, the inner and outer perimeters of the bone. The obtained results were as follows: 1. In the morphometric analysis, total area and outer perimeter of the mandibular bodies of Group 3 were a little smaller than that of Group 1. The mean bone width and bone area were much smaller than that of Group 1 and the inner perimeter of Group 3 was much longer than that of Group 1. The total area and outer perimeter of Group 2 and Group 4 showed little difference. The mean bone width and bone area of Group 4 were smaller than that of Group 2 and the inner perimeter of Group 4 was longer than that of Group 2. 2. The remarkable decreases of the number and thickness of trabeculae and also the resorption of endosteal surface of cortical bone could be seen in the microradiogram of Group 3, Group 4 since the 3rd day of experiment. On the 21st day of experiment, the above findings could be more clearly seen in Group 4 than in Group 3. 3. The bone mineral density of Group 3 was lesser than that of Group 1 and the bone mineral density of Group 4 was lesser than that of Group 2 on the 7th, 14th, 21st days. The irradiation caused the bone mineral density to be decreased regardless of diet. In the case of Groups with low calcium diet, the bone mineral density was much decreased on the 21st day than on the 3rd day of experiment. 4. The calcium content in mandible of Group 3 was smaller than that of Group 1 throughout the experiment. roup 4 showed the least amount of calcium content. The irradiation caused the calcium content to be decreased regardless of diet. In the case of Groups with low calcium diet, the calcium content was much decreased on the 21st day than on the 3rd day of experiment. In conclusion, the present study demonstrated that morphological changs and decrease of bone mass due to resorption of bone by low calcium diet, and that the resorption of bone could be found in the spongeous bone and endosteal surface of cortical bone. So the problem of resorption of bone must be considered when the old and the postmenopausal women are taken radiotherapy because the irradiation seems to be accelerated the resorption of osteoporotic bone.

  • PDF

Chemical and Optical Absorption Spectroscopic Study of Colored Tourmalines (유색 전기석의 화학적 및 광학흡수 분광학적 연구)

  • Kim, Hee-Jong;Kim, Soo-Jin
    • Journal of the Mineralogical Society of Korea
    • /
    • v.6 no.1
    • /
    • pp.1-16
    • /
    • 1993
  • The chemical and optical absorption spectroscopic characters of pink and colorless tourmalines from San Diego mine in California, U.S.A., blue/green tourmalines from anonymous mine, Brazil, and brownis black tourmalines from Uncheon and Haksan mines in Korea have been studied using X-ray diffractometer, electron microprobe, optical absorption spectroscopy, and heat treatment. Least-squares refinements give unit cell diminsions : a = 15.96-16.01 ${\AA}$, c = 7.15-7.16 ${\AA}$ for the brownish black tourmalines, a = 15.82 - 15.87 ${\AA}$, c = 7.09 - 7.10 ${\AA}$ for pink tourmalines, and a = 15.88 - 15.94 ${\AA}$, c = 7.12 - 7.15 ${\AA}$ for blue green tourmalines. The colors of tourmalines are responsible for the transition elements. The pink color is attributed to the $Mn^{3+}$ ions, the blue-green to $Fe^{2+}$ and $Mn^{2+}$, bluish green to $Cu^{2+}$, and the brownish black to $Fe^{2+}$, $Fe^{2+}$ - $Fe^{3+}$, and $Fe^{2+}$ - $Ti^{4+}$. The $Mn^{3+}$ ions of pink color tourmalines are stabilized in the Y sites compressed along the O(1)H-O(3)H axis by Jahn-Teller distortion. Heating removes the pink or red component from tourmalines, producing the colorless stones from the pink and red ones. The bluish green samples change into the greenish blue ones and a certain yellowish green samples change into the light green ones by heat treatment. In the elbaite-schorl series, the concentration of Fe and Mn are variable depending on the color zones. The green zone is characterrized by the high content of Fe and Mn are variable depending on the color zones. The green zone is characterized by the high content of Fe, whereas the pink zone by the high content of Mn. Mn increases in deep yellow zone compared with yellow or colorless zones.

  • PDF