• Title/Summary/Keyword: X-ray safety management

Search Result 55, Processing Time 0.026 seconds

Fabrication of CdS Solar Cells Prepared by Chemical Pyrolysis Deposition (화학적 열분해방법에 의한 CdS 태양전지의 제작)

  • 고정곤;김홍복;허윤성
    • Journal of the Korea Safety Management & Science
    • /
    • v.4 no.2
    • /
    • pp.199-207
    • /
    • 2002
  • The polycrystalline CdS of large scale were grown by chemical pyrolysis deposition for $Cu_2$S/CdS heterojunction solar cells. For high quality CdS polycrystalline thin films, the chemical solution was deposited on indium tin oxide(ITO) glasses at the temperature of 50$0^{\circ}C$ for 15 second and annealed at 35$0^{\circ}C$ for 20 minute or 50$0^{\circ}C$ for 30 second. To fabricate high efficiency solar cells, optical and electrical properties, morphology by SEM and x-ray diffraction on polycrystalline CdS thin films were investigated. From the I-V characteristics of $Cu_2$S/CdS heterojunction, the open circuit voltage, $V_{oc}$ was 0.7 V and the short circuit current, $I_{sc}$ was 4.2 mA. We found that the fill factor(FF) was 0.5 and the efficiency was 2.5%.

Analysis of Fire Risk through Battery Fire Cases and Experiments of Wearable Devices (웨어러블 기기의 배터리화재사례와 실험을 통한 화재위험성 분석)

  • Lee, Jung-Il
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.2
    • /
    • pp.47-55
    • /
    • 2020
  • This study analyzed ignition probability about Lithium-polymer batteries of what variously were being produced wearable devices recently. The study analyzed ignition probability by PCM(Protection Circuit Module) operating state and overcharged, over-discharged, exposed to high temperatures of Lithium polymer batteries, analyzing wearable devices on the market. Then it classified experimental results to implement analysis comparison about weight, X-ray imaging, battery decomposition. With these experiments, the study analyzed combustion-possibility and fire patterns. These statistics will be used to measure and verify the cause of a fire when identify wearable devices using Lithium-polymer batteries.

Amendment of the Inspection Standard for Diagnostic Radiation Equipment Applying IEC 60601-1-3: Medical Electrical Equipment - Part 1-3: General Requirements for Basic Safety and Essential Performance - Collateral Standard: Radiation Protection in Diagnostic X-ray Equipment (KS C IEC60601-1-3: 의료용 전기기기-제1-3부: 기본 안전 및 필수 성능에 관한 일반 요구사항-보조표준: 진단용 X선 장치의 방사선 방어를 적용한 진단용 방사선 발생장치의 검사기준 개선안)

  • Park, Hye-Min;Kim, Jung-Min;Kim, Jung-Su;Kim, Seong-Ok;Choi, Young-Min
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.493-504
    • /
    • 2018
  • The diagnostic radiation equipment is managed in accordance with the "Rules for Safety Management of Diagnostic Radiation Equipment" enacted in 1995. The equipments should be inspected before use and every three years after use in accordance with the [Appendix 1] of the same rule. The inspection standard has been maintained without particular revision since enacted. But, over the past two decades new types of equipments have been manufactured and used. So, it is necessary to revise [Appendix 1] by making inspection items and inspection standards. In this study, we revised the classification system of equipments and reviewed international standards of IEC 60601 series, IEC 61223 series and AAPM TG 18 On-line Report No.03. And identified the problem of current inspection standards. Through this, we revised, deleted and added the inspection items and inspection standard of each equipment to meet the domestic circumstances. As a result of the study, we reorganized the classification system of equipment which are current classified as 5 classes into 22 classes as X-ray system etc. (7 classes), CT system etc. (5 classes) and Dental X-ray system etc. (10 classes). And then, we developed 70 inspection items for 6 types of equipments according to the reorganized classification system of equipments. The inspection items and inspection standards derived from this study have been proposed to the KCDC and will be applied to the revision of the Rule's [Appendix 1]. Therefore, we expect to be used as reference materials for domestic medical center, inspection institutions, and equipment manufacturing import companies.

Dose Change according to Diameter Change of the Cone for Dental X-ray Apparatus (치과구내용 X선발생기의 조사통 직경 변화에 따른 선량변화)

  • Ahn, Sung-Min;Oh, Jung-Hoan;Choi, Jung-Hyun;Shin, Gwi-Soon;Kim, Sung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.3
    • /
    • pp.266-270
    • /
    • 2010
  • In case of the Dental X-ray apparatus, the diameter (or the field size) of the tip of the cone should be less than 7 cm according to the Diagnosis Radiation Equipment Safety Management. However, deviation from the field is not expected to be big as photography is made at close range from the skin. Also, as the size of film or digital detector used in intra-oral photography is $3\times4cm^2$, the size mentioned above can be considered to be much bigger. Furthermore, the patient dose by short-distance photography can not be ignored. Therefore, effect on the patient dose, resolution and image qualty was examined by reducing the cone diameter by 0.5 cm interval. The result showed that the patient dose was reduced and a partial improvement in picture contrast was observed. Therefore, it can be concluded from these results that further investigation may be worthwhile in terms of policy.

Development of a Medical Radiation Simulator System for Education and Proposal of a Research Model (교육용 의료방사선 시뮬레이터 시스템 개발 및 연구 모델 제안)

  • Chang-Hwa Han;Young-Hwang Jeon;Jae-Bok Han;Chang-gi Kong;Jong-Nam Song
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.459-464
    • /
    • 2023
  • Due to the development of advanced technology, a lot of digital radiographic equipment has been developed, which is very helpful for accurate diagnosis and treatment, and it is very important to train personnel who have acquired professional knowledge in order to use it safely and effectively. Students are exposed to the risk of radiation exposure in radiography training using diagnostic X-ray equipment, and some educational institutions do not use X-ray equipment due to management difficulties in accordance with the Nuclear Safety Act. As a solution to this, this study developed a medical radiation simulator for education that does not generate radiation by using a vision sensor and self-developed software. Through this, educational institutions can reduce the burden of administrative implementation according to the law, and students can obtain a high level of educational effects in a healthy practice environment without radiation exposure.

Control of Lycoriella ingenua (Diptera: Sciaridae) in Exports of King Oyster Mushroom, Pleurotus eryngii, using Ionizing Radiation (이온화에너지를 이용한 수출용 큰느타리버섯의 긴수염버섯파리 방제)

  • Hyeonmo Ahn;Sun-Ran Cho;Hyun-Na Koo;Gil-Hah Kim
    • Korean journal of applied entomology
    • /
    • v.62 no.4
    • /
    • pp.333-343
    • /
    • 2023
  • King oyster mushrooms are one of the major fresh agricultural products which their exports are increasing every year in Korea. Lycoriella ingenua, is notorious insect pest in agriculture, especially in mushroom production. Larvae of L. ingenua cause mainly direct crop damage and adults are vectors of several dangerous fungal pathogens. In this study, the effects of electron beam, X-ray, and gamma-ray irradiation on the development and reproduction of L. ingenua were evaluated. In addition, to find the optimal dose to control L. ingenua in a box filled with king oyster mushrooms, an empirical experiment was conducted for each radiation. As a result, the development and reproduction of L. ingenua were inhibited at 50 Gy for all electron beam, X-ray, and gamma-ray irradiation. Additionally, at the top, middle, and bottom of the export box filled with king oyster mushrooms, the development and reproduction of L. ingenua were inhibited by electron beam with 150 Gy, X-ray with 100 Gy, and gamma-ray with 50 Gy. These results can be provided as basic data for establishing an integrated quarantine management system when exporting mushrooms. It will also contribute to the safety of agricultural products and the strengthening of export competitiveness.

A study on the system improvement policy according to the status analysis of medical device control system in Korea (국내 의료기기관리제도의 현황분석에 따른 정책적 제도개선 방안에 관한 연구)

  • Lee, Kyung-Man;Baek, Nak-Ki;Seo, Jong-Hyun
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.3
    • /
    • pp.37-52
    • /
    • 2010
  • This study is aimed at proposing the national policy for medical device control system in Korea as deeply analysed the present status of the system. On 1979, Korean government had started to inspect 24 kinds of the medical devices such as X-ray diagnostic equipments, medical sterilizer and etc. mostly imported from advanced countries which USA, Germany and Japan for the first time according to the Pharmaceutical Affairs Law. However medical devices were becoming consideration as an important partner of diagnosis, curing and alleviation of diseases by medical doctors and also much important keeping the health at home. Furthermore medical devices industry can be designated as a national growth engine industry. So it is necessary not only to harmonize to international standards but also the harmonization of the system including pre-market application and post-market surveillance, is strongly needed by the Korea Food and Drugs Administration(KFDA).

Occupational Health Management in the Lead Industry: The Korean Experience

  • Lee, Byung-Kook
    • Safety and Health at Work
    • /
    • v.2 no.2
    • /
    • pp.87-96
    • /
    • 2011
  • In 1967, the problem of occupational lead exposure came to public attention in Korea. Since then, regular progress has been made in lowering workplace lead exposures, instituting new workplace controls, and implementing health examinations of exposed workers. Past serious lead poisoning episodes made it possible to introduce biological monitoring programs on a voluntary basis in high-lead-exposure facilities in Korea. Industry-specific occupational health services for lead workers in Korea during the last 22 years can be categorized into three phases. During the first phase (1988-1993), efforts were directed at increasing awareness among workers about the hazards of lead exposure, biological monitoring of blood zinc protoporphyrin began, and a respiratory protection program was introduced. During the second phase (1994-1997), a computerized health management system for lead workers was developed, blood-lead measurement was added to biologic monitoring, and engineering controls were introduced in the workplace to lower air-lead levels to comply with air-lead regulations. Finally, during the third phase (1998-present), a new biomarker, bone-lead measurement by X-ray fluorescence, was introduced. Bone-lead measurement proved to be useful for assessing body burden and to demonstrate past lead exposure in retired workers. Occupational health service practice for lead workers, including the industry-specific group occupational health system, has brought considerable success in the prevention of lead poisoning and in reducing the lead burden in Korean lead workers during the last several decades. The successful achievement of prevention of lead poisoning in Korea was a result of the combined efforts of lead workers, employers, relevant government agencies, and academic institutes.

Multilevel Percutaneous Vertebroplasty (More than Three Levels) in the Management of Osteoporotic Fractures

  • Zidan, Ihab;Fayed, Ahmed Abdelaziz;Elwany, Amr
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.6
    • /
    • pp.700-706
    • /
    • 2018
  • Objective : Percutaneous vertebroplasty (PV) is a minimally invasive procedure designed to treat various spinal pathologies. The maximum number of levels to be injected at one setting is still debatable. This study was done to evaluate the usefulness and safety of multilevel PV (more than three vertebrae) in management of osteoporotic fractures. Methods : This prospective study was carried out on consecutive 40 patients with osteoporotic fractures who had been operated for multilevel PV (more than three levels). There were 28 females and 12 males and their ages ranged from 60 to 85 years with mean age of 72.5 years. We had injected 194 vertebrae in those 40 patients (four levels in 16 patients, five levels in 14 patients, and six levels in 10 patients). Visual analogue scale (VAS) was used for pain intensity measurement and plain X-ray films and computed tomography scan were used for radiological assessment. The mean follow-up period was 21.7 months (range, 12-40). Results : Asymptomatic bone cement leakage has occurred in 12 patients (30%) in the present study. Symptomatic pulmonary embolism was observed in one patient. Significant improvement of pain was recorded immediate postoperative in 36 patients (90%). Conclusion : Multilevel PV for the treatment of osteoporotic fractures is a safe and successful procedure that can significantly reduce pain and improve patient's condition without a significant morbidity. It is considered a cost effective procedure allowing a rapid restoration of patient mobility.

The Effects of Aronia Extract on Body Weight and Body Fat: A Randomized, Double-Blind, Placebo-Controlled Clinical Trial (체지방에 대한 아로니아 추출물의 효과: 무작위배정, 이중눈가림, 위약-대조 임상연구)

  • Ha, Ki Chan;Park, Yu Kyung;Baek, Hyang Im;Kim, Hye Mi;Kim, Young Mi;Jeong, Da Young;Shin, Sang Wook;Bae, Jung Shik;An, Ji Hye;Jeon, Yeon Jeong;Park, Ji Eun;Kwon, Young Dal
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.30 no.1
    • /
    • pp.105-113
    • /
    • 2020
  • Objectives Excess weight and obesity are a crucial public health problem worldwide and are considered as the main cause of many chronic diseases. The present study evaluated the effects of Aronia melanocarpa extract (AMEX) supplementation on body compositions in overweight or obese people. Methods This randomized, double-blind, placebo-controlled clinical trial was carried out on 66 healthy overweight or obese peoples. The eligible subjects were divided into AMEX and placebo supplement treatment for 12 weeks. Anthropometrics, body composition (dual-energy X-ray absorptiometry), and blood analysis were performed preand post intervention. Results We observed significant reductions in the body weight and body mass index in both groups; however, the decrease was higher in the AMEX group. Body fat mass and percent body fat showed a tendency to decreases after AMEX supplementation. No clinically significant changes were observed for any safety parameter. Conclusions In conclusion, the data of this trial indicate that AMEX were not effective in reducing body compositions, but as a safe supplement, it may help weight loss in overweight or obese people.