• 제목/요약/키워드: X-ray safety management

검색결과 55건 처리시간 0.027초

사업장 단체검진 시 흉부촬영의 방사선피폭 최적화 및 안전에 대한 고찰 (- A Study on Safety of the Radiation Exposure Dose Optimization at Chest B-ray Examinations -)

  • 임재동;강경식
    • 대한안전경영과학회지
    • /
    • 제6권3호
    • /
    • pp.87-97
    • /
    • 2004
  • The National Health Insurance Act, the Industrial Health Act and the School Health Act require chest radiography at least once a year. In chest radiographic examination, most group examinations use indirect X-ray primarily aiming at diagnosing diseases and enhancing people's health. This study purposed to minimize radiation exposure dose by comparing it between direct and indirect chest X-ray studies. According to the result of comparing and analyzing radiation exposure dose, the average incident dose and penetrating dose were 0.929μGy and 0.179μGy respectively in direct chest X-ray and 6.807μGy and 1.337μGy in indirect chest X-ray In order to minimize radiation exposure dose at direct and indirect chest X-ray, indirect X-ray should be excluded from group examination if possible. Moreover, it is necessary to control the quality of equipment (Q/A & Q/C) systematically and to avoid using unqualified equipment in order to reduce radiation exposure dose.

환자의 안전을 위한 입식 X선 촬영 보조기구 개발 및 유용성 평가 (The Development of Assistant Device for the Standing X-ray Views and Its Usability for the Patient Safety)

  • 길종원;김용권
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.223-229
    • /
    • 2015
  • In this study, We designed and implemented a assistant device for the standing X-ray views which is the one of the clinical X-ray imaging position. To evaluate the usability of the proposed assistant device, We choose 11 clinical patient postures that are used frequently and applied the postures to 5 volunteers. 11 images was taken from a volunteer for the patient postures. And we conducted a survey on safety and clinical usefulness, the 5 volunteers responded to the safety and 5 experts responded to the clinical usefulness. The survey results show that the volunteers feel more safe and the obtained images are very clear and clinically useful. The result for the image quality is 4.69 of 5(best) and safety is 2.84 of 3(best). It will be very profitable to both patients and hospitals by using the proposed assistant device.

이동형 X선 장치 차폐도구 제작을 통한 표면선량 분포 측정 (Measurement of Skin Dose Distribution for the Mobile X-ray Unit Collimator Shielding Device)

  • 홍선숙;김득용
    • 대한디지털의료영상학회논문지
    • /
    • 제12권1호
    • /
    • pp.5-8
    • /
    • 2010
  • Opened a court in February 10, 2006, a rule of safety management of the diagnosis radiation system was promulgated for safety of the radiation worker, patients and patients' family members. The purpose of this rule is to minimize the risk of being exposed to radiation during the process of handling X-ray. For this reason, we manufactured shielding device of mobile X-ray unit collimator for diminution of skin dose. Shielding device is made to a thickness of Pb 0.375mm. For portable chest radiography, we measured skin dose 50cm from center ray to 200cm at intervals of 20cm by Unfors Xi detector. As a result, a rule of safety management of the diagnosis radiation system has been strengthened. But there are exceptions, such as ER, OR, ICU to this rule. So shielding device could contribute to protect unnecessary radiation exposure and improve nation's health.

  • PDF

동물병원의 방사선발생장치 정도관리에 대한 연구 (Quality Control of Diagnostic X-ray Units for Animal Hospital)

  • 김상우;이지훈;박예슬;임재동;성열훈
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2010년도 춘계학술대회
    • /
    • pp.231-237
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using quality assurance (QA) and quality control (QC) of diagnostic X-ray units. The surveys for QA/QC, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The QA/QC included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. As a result, 44.44% of reproducibility of dose exposure was proper, 81. 25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test.

  • PDF

교육용 치과 엑스선 발생장치에 대한 방사선 안전 관리 실태 조사 (Research on the Actual Condition of the radiation Safety Management(RSM) for the Educated Training of the Dental Diagnostics X-ray Generators)

  • 이미현;유윤식;이재승;임인철
    • 한국방사선학회논문지
    • /
    • 제8권7호
    • /
    • pp.467-477
    • /
    • 2014
  • 본 연구의 목적은 교육용 치과 엑스선 발생장치를 설치 및 가동 중인 전국 치위생(학)과를 대상으로 방사선 작업종사자의 방사선 안전 관리 실태를 설문 조사하고 이를 체계적으로 추이 분석하여 교육용 치과 엑스선 발생장치의 안전한 이용 기반을 확립하기 위한 기초 자료로 제공하고자 하였다. 이를 위하여 교육용 치과 엑스선 발생장치의 방사선 안전 관리와 관계되는 원자력 관계 법령 및 국내 방사선 안전성 평가 및 규제 기술 개발 현황에 대한 용역 보고서를 참고하여 포괄적인 문헌 조사를 하였으며 이를 토대로 응답자의 일반적 특성, 방사선안전관리자의 위상, 방사선 안전관리 현황과 지식 및 의식 수준에 대한 설문지를 작성하였다. 본 연구는 국내 교육기관 내 방사선안전관리자와 교육용 치과 엑스선 발생장치를 운전 가능한 학사 및 실습 조교, 전임 교원 224명을 대상으로 설문 조사를 시행하여 설문 응답 누락 및 불충분한 응답을 제외한 95부를 회수하여 분석 자료로 이용하였다. 분석 방법은 일반적 특성 및 방사선안전관리자의 위상은 빈도와 백분율을 구하였으며 방사선 안전 관리 현황과 지식 및 의식 수준은 빈도 분석과 설문 문항별 연관성 분석을 위한 ${\chi}^2$ 검정(chi-square test)과 수준간 연관성을 구하기 위한 피어슨 상관분석(Pearson correlation analysis)을 하였다. 결과적으로 교육용 치과 엑스선 발생장치의 운영은 대부분 대학 이상의 사회적 교육 수준이 높고 치위생학을 전공한 20대에서 40대의 여성이 담당하고 있었으며 남성과 비교하여 방사선 안전 관리에 대한 의식 수준이 높게 나타났으며 통계적으로 유의한 선형적 관계를 보였다(${\chi}^2$ >5, 0.1${\chi}^2$ >5, 0.3${\chi}^2$ >5, 0.3

임산부 흉부촬영 시 복부차폐의 적정성 평가 (Adequacy Assessment to Abdomen Shield of Pregnant X-ray Chest PA)

  • 김기진;김가중
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.207-212
    • /
    • 2015
  • When performing Chest x-ray examination to pregnant woman, normally we shield back side of abdomen. In this situation, scattered rays made by equipment and surrounding structure can enter front side of abdomen. Therefore, in this study, we evaluate suitability of abdomen shield especially to pregnant woman. In case of One shielding material placed back of abdomen, the measured value is $0.676{\pm}0.19uSv/hr$. Two shielding material is $0.764{\pm}0.04uSv/hr$. Three is $0.685{\pm}0.16uSv/hr$. The exposure dose inferred in this study does not excess annual effective dose limit. But It is not mean absolute safety. So we have to minimize occurrence of stochastic effect of radiosensitivity by shielding front side of abdomen of pregnant woman in clinic.

진단용 방사선발생장치의 검사기준을 적용한 동물병원의 방사선 안전관리 (The Radiation Safety Management in the Animal Hospital Using Inspection Standard of Diagnosis Radiation System)

  • 김상우;임재동;한동균;성열훈
    • 대한안전경영과학회지
    • /
    • 제12권4호
    • /
    • pp.73-80
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using inspection standard of X-ray generator for diagnosis. The surveys for inspection standard system, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The inspection standard included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. The surveys of equipment condition and safety supervision used one-on-one interview with 5 points measurement. As a result, 44.44% of reproducibility of dose exposure was proper, 81.25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test. The 100mA electric capacity of X-ray generator for diagnosis was popular with 44.44%, and its 55.56% was purchased used equipment. Monthly average of less than 50 times (61.11%) was top frequency in use, and no animal clinic had a thermo-luminescence dosimeter(TLD). The 16 animal clinics with radiation safety zone and 2 without radiation safety zone were appeared.

진단용 방사선안전관리 현황에 관한 연구 (A Study on Enforcement Effects of Radiation Safety Control Regulations for Diagnostic X-ray Equipments)

  • 성모일;박명환;권덕문;이준일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제22권1호
    • /
    • pp.73-78
    • /
    • 1999
  • The purposes of this study are to analyze the realities after enforcements of safety control regulations for diagnostic X-ray equipments and to suggest means for an improvement of low radiation safety control. A questionnaire survey for medical radiologic technologists was carried out to determine enforcement effects of the safety control regulations. The results of analysis from the survey are as follows. That is, most of the respondents realized the importance of the radiation safety control system, but about a half of them revealed that the regulations were not well observed in accordance with their purposes. Only 43.9% of the respondents took an active part in quality control and safety control of radiation. And respondents responsibility, sex, age, and knowledge for safety control were important indicators for observations of the regulations. Trainings for the safety control regulations are needed to ensure safety control and proper usage of diagnostic X-ray equipments. And management of organizations using diagnostic X-ray equipments have to understand and stress the importance of radiation safety control system.

  • PDF

환자 안전을 위한 비 계측 선량측정의 활용 : NDD-M (Non Dosimetry Measurements Use for Patients Safety : NDD-M)

  • 길종원;선종률;송월수
    • 대한안전경영과학회지
    • /
    • 제18권1호
    • /
    • pp.141-145
    • /
    • 2016
  • This study was to improve to utilization of non dosimetry measurements for X-ray radiography. Experiments was passed off varying the X-ray tube voltage and the thickness of the aluminum filter by actual dose. Calculated results was set to the first beam quality factors, calculated first correction coefficient by the Microsoft Excel program was set as the second beam quality factors. To make the non dosimetry measurements simply, the Excel program apply to the new beam quality factors, the error was compared to the previous studies, and the results verify the calculated value of smaller errors.

국내 동물병원의 진단용 방사선 발생장치 및 방사선 관계종사자 안전관리에 관한 융복합적 분석 (Convergence analysis of safety management for radiation workers and diagnostic radiation-generator devices of animal hospital in Korea)

  • 강경묵;서태영;김용상;윤선종
    • 한국융합학회논문지
    • /
    • 제11권4호
    • /
    • pp.55-61
    • /
    • 2020
  • 다양한 종류의 방사선 발생장치가 동물병원에서 사용되면서 방사선 관계종사자들의 안전이 중요해지고 있으나 방사선 발생장치 및 방사선 관계종사자들에 대한 안전관리 정보가 없는 실정이다. 이에 본 연구에서는 방사선 검사기관 및 측정기관, 시·군·구에서 조사되어진 방사선 발생장치 및 관계종사자, 피폭선량 등을 조사, 분석하였다. 최근 6년간 동물병원에서의 방사선 발생장치와 관계종사자 수는 각각 2,138대에서 2,972대, 2,644명에서 5,733명으로 증가하였다. 2019년 방사선 발생장치의 수는 일반 X-ray, CT, C-arm, 이동형 X-ray, 치과용 X-ray는 각각 2,204대, 58대, 67대, 770대, 14대인 것으로 조사되었다. 2019년 방사선 관계종사자 수는 수의사 4,236명, 수의간호사 1,080명, 업무보조원 404명, 기타 13명인 것으로 조사되었다. 2018년 방사선 관계종사자 연간평균피폭선량은 표층선량 0.21mSv, 심부선량 0.18mSv인 것으로 나타났다. 본 연구는 동물병원에서 사용하고 있는 방사선 발생장치 및 방사선 관계종사자의 안전관리에 대한 기초 자료가 될 것으로 기대한다.