• Title/Summary/Keyword: X-ray radiography

Search Result 519, Processing Time 0.031 seconds

Effect of Field Size on the Clinical Exposure Index for Lumbar Spine X-ray Examination (노출지수를 이용한 요추 X선 촬영의 조사야 유효성 평가)

  • Park, Hyemin;Yoon, Yongsu;Kim, Jungsu;Jeong, Hoiwoun
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.183-187
    • /
    • 2021
  • The field size of the lumbar spine X-ray examination, which belongs to the most frequent examination in general radiography, is 5 times wider than the width of the lumbar spine. Exposure index (EI) as per International Electrotechnical Commission has a proportional relationship with the dose incident on the image receptor for clinical protocols in addition to RQA5, which is a calibration beam quality. In this study, the effectiveness of the set field size was evaluated through the change of EI according to the size of field during lumbar spine X-ray examinations. Lumbar anterior-posterior and lateral examinations was performed using a whole-body phantom, and the national average exposure conditions of Korea investigated in 2017 were introduced for the X-ray exposure. As a result of comparing the EI displayed on the console of digital radiography system for the three field size in ① 18 × 36 cm2 ② 25 × 36 cm2 ③ 36 × 36 cm2, the EI values showed a tendency to increase as the field size increased. Since the patient dose, such as organ dose around the lumbar spine, increases as the field size becomes larger, thus, if the EI obtained from the field size at a level that does not interfere with diagnosis is set as a reference, the effectiveness of the field size can be evaluated through the EI displayed on the console when the lumbar spine X-ray examination is conducted.

Comparison of the Modulation Transfer Function of Several Image Plate (Image Plate(IP) 영상의 MTF 비교)

  • Kim, Chang-Bok;Lee, Yang-Sup;Kim, Young-Keun;Lee, Seong-Kil;Lee, Kyung-Sup
    • Journal of radiological science and technology
    • /
    • v.27 no.3
    • /
    • pp.25-29
    • /
    • 2004
  • Among the digital radiography systems, the computed radiography Image Plate Detector System is most frequently being used for the general radiography and also this system commonly diffracts the x-ray images since it is the system that is influenced by the light diffusion from the fluorescent substances. In this study, by using the X-ray Generator, a comparative analysis has been made between 2 different models of computer radiography image plate investigate each model's resolution and sharpness through the modulation transfer function(MTF) measurement. For the analysis, two image plates for general radiography one Fuji ST-VN model(more than 3years old) and one Fuji ST-VL model(less than 2years old) that are currently being used in "Hospital A" were sampled for the MTF measurement here. As the experimental method for this study, the resolution chart method has been carried out by using X-ray generator. Also all the experimental data were printed out by laser printer and measured by microdensitometer. As the results of the experiment carried out in this study, some differences have been found between the two different IP models and Fuji ST-VL has shown its excellence in both of the resolution and the sharpness fields.

  • PDF

A Study on Radiographical Conditions and Exposure Doses During Chest Radiography at Medical Facilities in Pusan (부산지역 의료기관의 흉부촬영 조건과 피폭선량에 관한 조사연구)

  • Jeon, Sung-Oh;Cho, Young-Ha
    • Journal of radiological science and technology
    • /
    • v.20 no.2
    • /
    • pp.49-55
    • /
    • 1997
  • This study was carried out to investigate radiographical and operating conditions of X-ray units and exposure doses to patients during chest radiography, so that the results could provide basic data used for reducing the exposure dose and for providing the diagnostic information with better quality. The conditions and exposure doses of 100 X-ray units mainly used for chest radiography were examined and also 100 radiological technologists mainly handling those apparatus at 76 medical facilities in Pusan were surveyed using a questionnaire from October 1 to December 31 in 1995. The following results were obtained from the study : 1. It was found that most units were capable of taking a high tube voltage radiography by showing 67% of the units equipped with the maximum tube voltage of 150 kV, 94% with more than 500 mA for the rating capacity and 85% with the full wave type of a signal phase. 2. For actual chest radiographical conditions, however, 80% of the units were operated at $60{\sim}100\;kVp$ and only 14% at 100 kVp and over for the high tube voltage. 3. The average exposure time was less than 0.1 second, and eighty four percent of the units adapted the X-ray tube currents ranging from 200 to 300 mA, 80% the focus-film distances between 180 and 210 cm, and 63% the focus sizes of more than 2.0 mm. 4. Most units(98%) employed additional filters made of aluminum, 75% the thickness of filters less than 2.0 mm, and only 2 units the compound filters. 5. Ortho chromatic system was only adopted in 13% of screen film system for the units, and 73% used the grid ratio at 8 : 1 for the low tube voltage during chest radiography. 6. The average exposure dose of all X-ray units during chest radiography was $371\;{\mu}Sv$ with a difference of about 16 times between the minimum to the maximum, and $386\;{\mu}Sv$ both at hospitals and at health centers, followed by $380\;{\mu}Sv$ at general hospitals and $263\;{\mu}Sv$ at university hospitals without showing any statistically significant differences. In conclusion, since patients during chest radiography at medical facilities in Pusan exposed to high levels of radiation, it is recommended that appropriate added filters and grids necessary for the high tube voltage radiography and high-speed screen systems should be adopted and used as soon as possible in order to reduce exposure dose to the patients.

  • PDF

A Comparative Study on Output of Four Type Diagnostic X-ray Equipments (정류방식에 따른 진단용 X-선 장치의 출력비교)

  • Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.20 no.2
    • /
    • pp.34-43
    • /
    • 1997
  • There are 4 types of equipment in diagnostic radiography. These are single phase, three phase, inverter type and condenser type X-ray generators. It is very confusing to make an adequate exposure factor and to know the usage of different type of X-ray generators. In this experiment, I explored a comparative study of outputs in 4 different type of X-ray units. I expect that this experiment could be helpful for manufacturer to make both the X-ray equipment better, In terms of Ideal exposure factors, thereby reducing the patient dose. Experimental results are as follow : 1) X-ray output The ratio of X-ray output of single, three phase and inverter type of X-ray generator was 1 : 1.6 : 2 without absorber and 1 : 2 : 2.6 with 20 mm aluminium absorber. 2) Beam quality The X-ray beam quality of single phase generator was proved to be softer than three phase and inverter type of generators by 0.4 mmAL and 0.55 mmAl HVL respectively. 3) Reproducibility Linearity of X-ray output Retroducibility of X-ray output met the regulation below CV 0.05 and linearity also met the regulation below 0.1 in 4 types of diagnostic X-ray generators. 4) The comparison of incident dose Three phase X-ray generator was 20% higher than two other X-ray generators in radiation dose to make same film density.

  • PDF

The study for electric readout of X-ray signal using MOSFET (MOSFET를 이용한 X선 신호의 전기적 획득에 관한 연구)

  • Park, S.K.;Kang, Y.S.;Seo, J.H.;Park, J.K.;Nam, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.295-296
    • /
    • 1998
  • With xeroradiography appearance, DR (Digital Radiography) system have been studying for X-ray detection using photoreceptor. Also detection method for receptor charge change have been developing variably. We use photoreceptor material of a-Se(Amorphous Selenium) with high DQE, high SNR(Signal to Noise Ratio) and high transformation efficiency of X-ray signals into electrical signals. After a-Se receptor is uniformly charged by using Arc discharge, X-ray is exposed. Then a-Se receptor produce subtle charge variation and MOSFET detect charge variations. The detected signal pass A/D converter and signal processing by PC. As results, the initial voltage is 8V. It has wide dynamic range needed digital radiography system. In this study, we obtained data with changing kVp(tube potential voltage) and fixed 8mAs(tube current by exposure time) in X-ray system. However MOSFET detector for X-ray signal is not tested X-ray mAs variations. But if MOSFET detector is tested X-ray mAs variation and exactly calibrated multichannel is made and noise-reduction is done, suitable DR system readout method will be done.

  • PDF

A Study on the Test of Efficiency of the Diagnostic X-ray Equipment according to Their Rectifications (진단용 X선장치의 성능 실태 조사연구)

  • Seon, Jong-Ryul
    • Journal of radiological science and technology
    • /
    • v.20 no.2
    • /
    • pp.44-48
    • /
    • 1997
  • For the efficient management of the diagnostic x-ray equipment, a nation-wide inspection of hospitals was performed by an inspection institute in Taejon in the first half of 1997. Among those hospitals inspected, 28 equipments(machines) which were over 500 mA were randomly selected according to their characteristics : 7 condenser type x-ray equipments, 7 three control phase of full wave rectification of type remote control x-ray equipments, 7 single phase of full wave rectification type for general radiography equipments, and 7 single phase of full wave rectification type of R/F equipments. We obtained the following results by conducting the experiment based on the efficiency of the equipments mentioned above. 1) When the equipments are analyzed, 2 out of 7 single phase of full wave rectification type of general radiography equipments(28.6%), 3 out of 7 single phase of full wave rectification type of R/F equipments(42.9%), 5 out of 7 three phase of full wave rectification type remote of control x-ray equipments(71.4%), and 4 out of 7 condenser type of x-ray equipments(57.1%) showed suitability. It proves the superiority of the three phase of full wave rectification type of remote control x-ray equipments. 2) From the overall analysis, only about 50% of the equipments(suitability of 14 out of 28) maintain the efficient management. Therefore, maintenance management of equipments is more necessary. If the efficiency of the x-ray equipment is uniformly maintained and managed to prevent the breakdown(trouble) beforehand especially through the continuous inspection of tube voltage, tube current, exposure time, and collimator, the financial loss and exposure dose to the patient, as well as the workers engaged in radiation, can be reduced for better medical service.

  • PDF

Development of Inspection System for Aluminum Castings with X-Ray TDI Camera (X-Ray TDI Camera를 이용한 알루미늄 주강품 검사장치 개발)

  • Nam, Mun-Ho;Park, Seong-Wook;Kim, Chang-Ho;Chung, Chan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1734-1735
    • /
    • 2011
  • In case of inspection on aluminum castings, traditional RT (Radiographic Testing) method have been utilized for its advantages in interpretation, cost and perpetual storage. But it has disadvantages like time consumption in film processing, low efficiency in storage and environmental pollution. In this thesis, a DRS (Digital Radiography System) utilizing X-Ray TDI Camera (Time Delay and Integration Camera) is developed. Inspections on aluminum castings are performed using the developed Digital Radiography System, DRS and reviewed if newly developed system can substitute for the traditional method.

  • PDF

Grid Angle Optimization and Grid Artifact Reduction in Digital Radiography Images Based on the Modulation Model (디지털 방사선 영상에서 그리드 각도의 최적화와 변조 모델에 기초한 그리드 왜곡의 제거)

  • Kim, Dong-Sik
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.3
    • /
    • pp.30-41
    • /
    • 2011
  • In order to obtain more clear x-ray images, an antiscatter grid, which can absorb the scattered rays, is employed. In the high-resolution direct digital radiography, however, the artifacts due to the grid are visible. In this paper, within the methods of obtaining x-ray digital images by employing the rotated grids for the facility of grid artifact reduction, the previous work, where the frequencies of the artifact components on the boundary, is further analyzed and extended, and a min-max optimization for a given grid density is proposed. For practical grid densities, appropriate grid angles are provided and a grid artifact reduction algorithm is proposed for the appropriate grid angles. The proposed algorithm is tested for real x-ray digital images with a comparison, and can remove the grid artifacts while maintaining the resolution of the original image.

The Comparison of X-ray Response Characteristics of Vacuum Evaporated $Cd_{1-x}Zn_{x}Te$ Detector (진공증착된 $Cd_{1-x}Zn_{x}Te$ 검출기의 X선 반응 특성 비교)

  • Kang, S.S.;Choi, J.Y.;Lee, D.G.;Cha, B.Y.;Kim, J.H.;Nam, S.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.39-42
    • /
    • 2002
  • There is a renewed interest in the application of photoconductors especially Cd(Zn)Te to x-ray imaging. In this paper, We investigate effects on x-ray detection characteristic of Zn dopped CdTe detector. Cd(Zn)Te film was fabricated by vacuum thermal evaporation method and then investigate physical analysis using EPMA and XRD. We investigated the leakage current and X-ray photosensitivity as applied voltage about fabricated Cd(Zn)Te film. Experimental results showed that the increase of Zn dopped concentration in $Cd_{1-x}Zn_{x}Te$ detector reduced a leakage current and improved a signal to noise ratio significantly.

  • PDF

Automated Detection of Pulmonary Nodules in Chest X-ray Radiography Using Genetic Algorithm (흉부 X-ray 영상에서 유전자 알고리즘을 이용한 폐 결절 자동 추출)

  • 류지연;이경일;장정란;오명진;이배호
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.10d
    • /
    • pp.553-555
    • /
    • 2002
  • 컴퓨터지원진단(Computer Aided Diagnosis; CAD) 시스템은 방사선 의사들이 흉부 X-ray 영상에서 결절을 탐지하는데 있어 실제적으로 발생할 수 있는 오진율을 줄이고, 폐 결절이 존재하는 폐야에서 결절의 존재 유무를 판단하여 검출을 표시함으로써 진단율을 개선시킬 수 있도록 하였다. 본 논문은 흉부 X-ray 영상에서의 폐 결절을 추출하는데 유전자 알고리즘(Genetic Algorithm)을 이용한 템플릿 매칭(Template Matching) 방법을 제안한다. 제안한 방법은 흉부 X-ray 영상에 존재하는 결절과 레퍼런스 이미지를 매칭시켜 적합도를 계산한 후, 그 값을 통하여 수치가 낮은 개체를 선택하여 높은 개체와 교차시킨다. 그리고 레퍼런스 이미지는 결절이 존재하는 환자 X-ray 영상에서 샘플 노듈을 추출한 후 가우시안 분포를 갖는 512개의 레퍼런스 이미지를 생성하였다. 본 논문에서 사용된 영상은 결절 50개, 비결절 30개와 흉부 X-ray 영상에서 육안으로 판별이 가능한 결절 영상을 20개를 포함하여 총 100개 영상을 사용하였다. 실험 결과 83%의 결절을 자동 추출 하였으며, 가장 적절한 레퍼런스 이미지를 발견하고 이를 흉부영상에 매칭시켜 정확한 결절의 위치를 확인하였다.

  • PDF