• 제목/요약/키워드: X-ray micro-computed tomography

검색결과 73건 처리시간 0.025초

Root canal volume change and transportation by Vortex Blue, ProTaper Next, and ProTaper Universal in curved root canals

  • Park, Hyun-Jin;Seo, Min-Seock;Moon, Young-Mi
    • Restorative Dentistry and Endodontics
    • /
    • 제43권1호
    • /
    • pp.3.1-3.10
    • /
    • 2018
  • Objectives: The aim of this study was to compare root canal volume change and canal transportation by Vortex Blue (VB; Dentsply Tulsa Dental Specialties), ProTaper Next (PTN; Dentsply Maillefer), and ProTaper Universal (PTU; Dentsply Maillefer) nickel-titanium rotary files in curved root canals. Materials and Methods: Thirty canals with $20^{\circ}-45^{\circ}$ of curvature from extracted human molars were used. Root canal instrumentation was performed with VB, PTN, and PTU files up to #30.06, X3, and F3, respectively. Changes in root canal volume before and after the instrumentation, and the amount and direction of canal transportation at 1, 3, and 5 mm from the root apex were measured by using micro-computed tomography. Data of canal volume change were statistically analyzed using one-way analysis of variance and Tukey test, while data of amount and direction of transportation were analyzed using Kruskal-Wallis and Mann-Whitney U test. Results: There were no significant differences among 3 groups in terms of canal volume change (p > 0.05). For the amount of transportation, PTN showed significantly less transportation than PTU at 3 mm level (p = 0.005). VB files showed no significant difference in canal transportation at all 3 levels with either PTN or PTU files. Also, VB files showed unique inward transportation tendency in the apical area. Conclusions: Other than PTN produced less amount of transportation than PTU at 3 mm level, all 3 file systems showed similar level of canal volume change and transportation, and VB file system could prepare the curved canals without significant shaping errors.

평판 디텍터 기반 마이크로 CT시스템을 위한 Ring Artifact 보정 방법 (A Ring Artifact Correction Method for a Flat-panel Detector Based Micro-CT System)

  • 김규원;이수열;조민형
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권6호
    • /
    • pp.476-481
    • /
    • 2009
  • The most troublesome artifacts in micro computed tomography (micro-CT) are ring artifacts. The ring artifacts are caused by non-uniform sensitivity and defective pixels of the x-ray detector. These ring artifacts seriously degrade the quality of CT images. In flat-panel detector based micro-CT systems, the ring artifacts are hardly removed by conventional correction methods of digital radiography, because very small difference of detector pixel signals may make severe ring artifacts. This paper presents a novel method to remove ring artifacts in flat-panel detector based micro-CT systems. First, the bad lines of a sinogram which are caused by defective pixels of the detector are identified, and then, they are corrected using a cubic spline interpolation technique. Finally, a ring artifacts free image is reconstructed from the corrected projections. We applied the method to various kinds of objects and found that the image qualities were much improved.

Micro-CT 시스템에서 제한된 조건의 Total Variation (TV) Minimization을 이용한 영상화질 평가 (Evaluation of Image Quality in Micro-CT System Using Constrained Total Variation (TV) Minimization)

  • 조병두;최종화;김윤환;이경호;김대홍;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제23권4호
    • /
    • pp.252-260
    • /
    • 2012
  • 최근 Computed tomography (CT) 조사선량의 인체에 대한 부정적 영향이 부각됨에 따라 선량을 줄이는 연구가 활발히 진행되고 있고, 이로 인하여 소 동물에 관한 연구는 점점 임상전의 연구로서 필수적으로 여겨지고 있다. 최근에는 피폭 선량을 줄일 수 있는 방법으로서 이론적으로 투영 데이터가 충분하지 않을 때 정확하게 영상을 재구성 하는 것이 가능한 Total Variation (TV) minimization 알고리즘이 각광받고 있다. 이에 본 연구에서는 micro-CT (DRGem, Harmony80H series, Korea) 시스템에서 획득한 적은 수의 투영 데이터를 가지고 TV minimization에 기초한 반복적 영상 재구성 알고리즘과 기존의 Feldkamp-Davis-Kress (FDK) 알고리즘을 사용하여 영상을 재구성하고 두 알고리즘의 영상 화질을 비교 및 평가하였다. TV minimization 알고리즘의 효과를 평가하기 위해서, 먼저 서로 다른 농도의 조영제, 물, 공기가 들어있는 원통형 팬톰을 제작하였고, micro-CT를 사용하여 영상을 획득하였다. Tube와 검출기 일회전 당 최대 400개의 투영 데이터를 획득할 수 있으며, TV minimization 알고리즘의 영상 복원의 정도를 평가하기 위해서 20, 50, 90, 180장의 적은 투영 데이터를 추출하였다. 영상 비교평가를 위한 참고 영상(FDK-reference 영상)은 마찬가지로 400개의 투영데이터를 이용하여 FDK 알고리즘으로 재구성하였고, 20, 50, 90, 180장의 투영데이터를 가지고 TV minimization 알고리즘, FDK 알고리즘을 이용하여 재구성한 영상과 FDK-reference 영상의 프로파일, Contrast-to-noise ratio (CNR), Universal quality index(UQI)를 각각 비교평가 하였다. 또한, 소 동물에 관한 연구를 위하여 mouse 영상에 관하여 프로파일과 UQI를 분석하여 비교평가 하였다. 결과적으로 90개의 투영데이터를 사용하여 재구성한 원통형 팬톰 영상을 분석하였을 때, TV minimization 영상(TV-90) 및 FDK 영상(FDK-90)의 CNR과 UQI를 비교하였을 때 FDK-90보다 TV-90에서 CNR이 0.21, UQI가 0.18 증가하였다. 원통형 팬톰 영상과 같은 조건에서 mouse 영상을 사용하였을 때, UQI는 FDK-90보다 TV-90에서 0.08 증가하였다. 결론적으로 본 연구결과는 기존의 micro-CT의 투영 데이터의 사분의 일이 되는 투영데이터를 사용하여 영상을 재구성하여 비교평가 한 결과 투영영상 데이터의 수가 제한되는 경우에 FDK 알고리즘보다 TV minimization 알고리즘이 X-ray 조사시간을 줄임으로서 피폭선량을 줄이는데 효과적으로 기여할 것으로 기대된다. 특히, 조사시간의 단축은 물체의 움직임으로 인한 영상 화질의 저하를 감소시키는데 기여할 것으로 사려된다.

돼지 하악골의 micro-CT영상에서 추출한 3차원 골미세구조와 골강도 사이의 상관관계 (Relationship between trabecular strength and three-dimensional architecture in the pig mandible using microcomputed tomography)

  • 허경회;박무순;이원진;허민석;이삼선;최순철
    • Imaging Science in Dentistry
    • /
    • 제35권3호
    • /
    • pp.167-173
    • /
    • 2005
  • Purpose : To investigate the relationship between three-dimensional (3D) bone imaging parameters and trabecular strength in the mandible. Materials and Methods : Bone specimens were obtained from the mandibles of five male pigs weighing around 110 kg each. Of those, 43 samples were selected for 3D analysis and measured by micro-computed tomography. The five morphometric parameters were trabecular thickness (Tb.Th), bone specific surface (BS/BV), percent bone volume (BV/TV), structure model index (SMI) and degree of anisotropy (DA). Through destructive mechanical testing, strength parameters were obtained. Results : BV/TV, SMI, BS/BV, and Tb.Th showed significant correlations with strength parameters. DA did not show any correlation with the other parameters. In multiple linear regression analysis, BV/TV alone explained $43\%$ of the variance in Young's modulus. By stepwise inclusion of SMI, the variance in the Young's modulus was better explained up to $52\%$. Conclusions : Predicting trabecular strength in the mandible through architectural analysis would be possible. Further study is needed to establish the tendency and variety of trabecular architecture and strength according to the locations within the mandible.

  • PDF

Micro-computed tomographic evaluation of single-cone obturation with three sealers

  • Sahar Zare;Ivy Shen;Qiang Zhu;Chul Ahn;Carolyn Primus;Takashi Komabayashi
    • Restorative Dentistry and Endodontics
    • /
    • 제46권2호
    • /
    • pp.25.1-25.12
    • /
    • 2021
  • Objectives: This study used micro-computed tomography (µCT) to compare voids and interfaces in single-cone obturation among AH Plus, EndoSequence BC, and prototype surface pre-reacted glass ionomer (S-PRG) sealers and to determine the percentage of sealer contact at the dentin and gutta-percha (GP) interfaces. Materials and Methods: Fifteen single-rooted human teeth were shaped using ProTaper NEXT size X5 rotary files using 2.5% NaOCl irrigation. Roots were obturated with a single-cone ProTaper NEXT GP point X5 with AH Plus, EndoSequence BC, or prototype S-PRG sealer (n = 5/group). Results: The volumes of GP, sealer, and voids were measured in the region of 0-2, 2-4, 4-6, and 6-8 mm from the apex, using image analysis of sagittal µCT scans. GP volume percentages were: AH Plus (75.5%), EndoSequence BC (87.3%), and prototype S-PRG (94.4%). Sealer volume percentages were less: AH Plus (14.3%), EndoSequence BC (6.8%), and prototype S-PRG (4.6%). Void percentages were AH Plus (10.1%), EndoSequence BC (5.9%), and prototype S-PRG (1.0%). Dentin-sealer contact ratios of AH Plus, EndoSequence BC, and prototype S-PRG groups were 82.4% ± 6.8%, 71.6% ± 25.3%, and 70.2% ± 9.4%, respectively. GP-sealer contact ratios of AH Plus, EndoSequence BC, and prototype S-PRG groups were 65.6% ± 29.1%, 80.7% ± 25.8%, and 87.0% ± 8.6%, respectively. Conclusions: Prototype S-PRG sealer created a low-void obturation, similar to EndoSequence BC sealer with similar dentin-sealer contact (> 70%) and GP-sealer contact (> 80%). Prototype S-PRG sealer presented comparable filling quality to EndoSequence BC sealer.

미세단층촬영기(Micro-CT)를 이용한 전자 근관장 측정기의 정확성에 관한 연구 (A Study on the accuracy of the elecronic apex locator using a micro-computed tomography)

  • 전경진;김양수;이호중;남태계
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.647-648
    • /
    • 2006
  • The length of root canal has to be measured to cure root canal. Several apex locators were developed to measure the length of root canal. And they were verified by X-ray or micrometer method. But these methods do not consider the non-linear bends of pulp and have ${\pm}0.5mm$ error which is large to measure the length of root canal. The purpose of this study is the research of new method to measure the length of root canal and verifying the apex locator using Micro-CT. The length of root canal of 6 teeth were measured with the apex locator. When the apex locator reads 0.5, 0.6, 0.7, 0.5, 0.9, 1.0mm, the teeth with the file fixed were photographed. The average lengths of root canal of 6 teeth measured by Micro-CT were 0.488, 0.589, 0.680, 0.775, 0.897, 0.992mm.

  • PDF

미세구조 분석방법을 활용한 서로 다른 밀도를 가진 기포콘크리트 특성 분석 (Investigation of Microstructural Characteristics of Foamed Concrete with Different Densities)

  • 정상엽;조수성;오서은
    • 대한토목학회논문집
    • /
    • 제43권1호
    • /
    • pp.1-7
    • /
    • 2023
  • 서로 다른 밀도를 가진 기포콘크리트 시편을 생성하고, 각 시편의 특성을 SEM, micro-CT 등의 미세구조 분석 방법을 활용하여 분석하였다. 서로 다른 재령 일자에 대한 기포콘크리트 시편의 공극과 고체 구조를 분석함으로써, 재령 기간이 재료 특성 변화에 미치는 영향을 살펴보았다. 각 기포콘크리트 시편의 압축강도와 열전도도를 측정하여, 재료 물성과 미세구조적 특성 간의 상관관계에 대하여 분석하였으며, 결과를 통해 밀도와 재령 기간이 재료 강도에 미치는 영향을 확인하였다.

Effect of different voxel sizes on the accuracy of CBCT measurements of trabecular bone microstructure: A comparative micro-CT study

  • Tayman, Mahmure Ayse;Kamburoglu, Kivanc;Ocak, Mert;Ozen, Dogukan
    • Imaging Science in Dentistry
    • /
    • 제52권2호
    • /
    • pp.171-179
    • /
    • 2022
  • Purpose: The aim of this study was to assess the accuracy of cone-beam computed tomographic (CBCT) images obtained using different voxel sizes in measuring trabecular bone microstructure in comparison to micro-CT. Materials and Methods: Twelve human skull bones containing posterior-mandibular alveolar bone regions were analyzed. CBCT images were obtained at voxel sizes of 0.075mm(high: HI) and 0.2mm(standard: Std), while microCT imaging used voxel sizes of 0.06 mm (HI) and 0.12 mm (Std). Analyses were performed using CTAn software with the standardized automatic global threshold method. Intraclass correlation coefficients were used to evaluate the consistency and agreement of paired measurements for bone volume (BV), percent bone volume (BV/TV), bone surface (BS), trabecular thickness (TbTh), trabecular separation (TbSp), trabecular number (TbN), trabecular pattern factor(TbPf), and structure model index (SMI). Results: When compared to micro-CT, CBCT images had higher BV, BV/TV, and TbTh values, while micro-CT images had lower BS, TbSp, TbN, TbPf, and SMI values (P<0.05). The BV, BV/BT, TbTh, and TbSp variables were higher with Std voxels, whereas the BS, TbPf, and SMI variables were higher with HI voxels for both imaging methods. For each imaging modality and voxel size evaluated, BV, BS, and TbTh were significantly different(P<0.05). TbN, TbPf, and SMI showed statistically significant differences between imaging methods(P<0.05). The consistency and absolute agreement between micro-CT and CBCT were excellent for all variables. Conclusion: This study demonstrated the potential of high-resolution CBCT imaging for quantitative bone morphometry assessment.

골절 유발 Rat에 대한 혈부축어탕(血府逐瘀湯)의 전임상 연구 (The Preclinical Study of Hyeolbuchugeo-tang (Xuefuzhuyu-tang) on Bone Healing in Rats with Rib Fracture)

  • 허건;오민석
    • 한방재활의학과학회지
    • /
    • 제30권3호
    • /
    • pp.23-44
    • /
    • 2020
  • Objectives The purpose of this study is to evaluate the healing effect of Hyeolbuchugeo-tang (HC) in rats with rib fracture. Methods Rats were randomly divided into 5 groups (naive, control, positive control, HC-L and HC-H). All groups except naive group were subjected to bone fracture of rib. Naive group received no treatment at all. Control group was fed with phosphate buffered saline. Positive control group was orally medicated with tramadol. Experimental group was orally medicated with HC extract (50 mg/kg for low concentration [HC-L], 100 mg/kg for high concentration [HC-H]). X-ray and micro-computed tomography (micro-CT) were conducted to assess the effect of HC. We analysed the level of 2) transforming growth factor-β1 (TGF-β1), Ki67, alkaline phosphatase (ALP), receptor activator of nuclear factor kappa-β, runt-related transcription factor 2 (Runx2) and tartrate resistant acid phosphatase (TRAP) on 7 and 14 days after fracture. ALP, alanine aminotransferase, aspartate aminotransferase, blood urea nitrogen, creatinine was measured for safety assessment. Results X-ray and micro-CT, showed HC enhance bone repair process. Callus formation was increased in experimental group at 7 days after fracture, but decreased at 14 days after fracture. 7 days after fracture, the level of TGF-β1 in experimental group was decreased. The level of Ki67, Runx2 in HC-H, TRAP in HC-L was increased. 14 days after fracture, the level of Ki67 in HC-L and HC-H was decreased. The level of ALP, Runx2, BUN in HC-L, TRAP in HC-L and HC-H was increased. Conclusions Taken together the results, HC promoted healing of bone fracture. In conclusion, HC has a potential to promote healing of bone fracture.

Characterization of electron beam (EB) welds for SUS310S

  • Kim, Hyun-Suk;Castro, Edward Joseph D.;Lee, Choong-Hun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.360-360
    • /
    • 2011
  • In this work, SUS310S used for valve plate assembly was electron beam (EB) welded to determine the influence of the parametric conditions on the characteristics of the weld and to minimize porosity and micro-fissures among others. The evolution in the weld geometry and microstructure was examined as a function of the process conditions such as beam current and focusing current under a constant welding speed and accelerating voltage. The integrity of the EB welds in SUS310S was examined for defects (e.g. cracking, porosity, etc.), adequate penetration depth, and tolerable weld width deviation for the various welding conditions. Optical microscopy (OM), x-ray photoelectron spectroscopy analysis (XPS), scanning electron microscopy (SEM) and 3D micro-computed tomography (Micro-CT) for the cross section analysis of the electron beam welded SUS310S were utilized. The tensile strength and hardness were analyzed for the mechanical properties of the EB weld. At the 6 kV accelerating voltage, it was determined that a satisfactory penetration depth and desirable weld width deviation requires a beam current of 30 mA and a focusing current of 0.687 A at the welding speed of 25 mm/sec.

  • PDF