• Title/Summary/Keyword: X-ray methods

Search Result 2,175, Processing Time 0.029 seconds

The Characteristics of Residual Stresses in the Welded Joint of P92 Steel for Fossil Power Plant by the X-ray Diffraction (X-ray 회절을 이용한 화력발전소용 P92 강 용접부의 잔류응력 특성)

  • Hyun, Jung-Seob;Yoo, Keun-Bong;Choi, Hyun-Sun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.7
    • /
    • pp.116-123
    • /
    • 2008
  • In the fossil power plant, the reliability of the components which consist of the many welded parts depends on the quality of welding. The residual stress is occurred by the heat flux of high temperature during weld process. This decreases the mechanical properties as the strength of fatigue and fracture or causes the stress corrosion cracking and fatigue fracture. Especially, the accidents due to the residual stress occurred at the weld parts of high-temperature and high-pressure pipes and steam headers. Also, the residual stress of the welded part in the recently constructed power plants has been brought into relief as the cause of various accidents. The aim of this study is the measurement of the residual stress using the x-ray diffraction method. The merits of this are more accurate and applicable than other methods. The materials used for the study is P92 steel for the use of high temperature pipe on super critical condition. The variables of tests are the post-weld heat treatment, the surface roughness and the depth from the original surface. The test results were analyzed by the distributed characteristics of the full width at half maximum intensity (FWHM) in x-ray diffraction intensity curve and by the relation of hardness with FWHM.

A Clinical Case Report on the Malalignment Treated by Chuna Manual Therapy - Based on the Full Spine AP X-ray and VAS - (추나치료를 이용한 골반, 척추 및 견갑대 부정렬의 치험 3례 - Full spine AP X-ray, VAS 분석에 따른 -)

  • Park, Ji-Hyun;Jeong, Hyun-A;Hong, Seo-Young
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.5 no.2
    • /
    • pp.135-149
    • /
    • 2010
  • Objectives : This study was designed to observe the effect of Chuna manual therapy on the asymmetrical alignment. Methods : To analyze static structural alignment, posterior inferior ilium deviation(PI), inflare change of pelvis were checked from full spine AP X-ray. And Cobb's angle of spine and height of shoulder girdle were analyzed. To evaluate the pain visual analogue score(VAS) was scored. Chuna therapy treated 8-10 times for 1 month. Results and Conclusions : In 3 cases, VAS was improved significantly. Full spine AP X-ray shows improvement of structural imbalace. Shoulder height difference, cobb's angle, pelvic insufficiency improved considerably. These results suggest that Chuna therapy might be effective for malalignment patients.

  • PDF

Development of a truncation artifact reduction method in stationary inverse-geometry X-ray laminography for non-destructive testing

  • Kim, Burnyoung;Yim, Dobin;Lee, Seungwan
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1626-1633
    • /
    • 2021
  • In an industrial field, non-destructive testing (NDT) is commonly used to inspect industrial products. Among NDT methods using radiation sources, X-ray laminography has several advantages, such as high depth resolution and low computational costs. Moreover, an X-ray laminography system with stationary source array and compact detector is able to reduce mechanical motion artifacts and improve inspection efficiency. However, this system, called stationary inverse-geometry X-ray laminography (s-IGXL), causes truncation artifacts in reconstructed images due to limited fields-of-view (FOVs). In this study, we proposed a projection data correction (PDC) method to reduce the truncation artifacts arisen in s-IGXL images, and the performance of the proposed method was evaluated with the different number of focal spots in terms of quantitative accuracy. Comparing with conventional techniques, the PDC method showed superior performance in reducing truncation artifacts and improved the quantitative accuracy of s-IGXL images for all the number of focal spots. In conclusion, the PDC method can improve the accuracy of s-IGXL images and allow precise NDT measurements.

Performance analysis of improved hybrid median filter applied to X-ray computed tomography images obtained with high-resolution photon-counting CZT detector: A pilot study

  • Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3380-3389
    • /
    • 2022
  • We evaluated the performance of an improved hybrid median filter (IHMF) applied to X-ray computed tomography (CT) images obtained using a high-resolution photon-counting cadmium zinc telluride (CZT) detector. To study how the proposed approach improves the image quality, we measured the noise levels and the overall CT-image quality. We established a CZT imaging system with a detector length of 5.12 cm and thickness of 0.3 cm and acquired phantom images. To evaluate the efficacy of the proposed filter, we first modeled two conventional median filters. Subsequently, we were able to achieve a normalized noise power spectrum result of ~10-8 mm2, and furthermore, the proposed method improved the contrast-to-noise ratio by a factor of ~1.51 and the coefficient of variation by 1.55 relative to the counterpart values of the no-filter image. In addition, the IHMF exhibited the best performance among the three filters considered as regards the peak signal-to-noise ratio and no-reference-based image-quality evaluation parameters. Thus, our results demonstrate that the IHMF approach provides a superior image performance over conventional median filtering methods when applied to actual CZT X-ray CT images.

Factors Associated with Radiologic Tests in Patients with Radial Head Subluxation (요골두아탈구 환자에서 방사선 검사 시행과 연관된 인자 분석)

  • Chang, Ikwan;Kim, Do Kyun;Park, So Young;Suh, Dongbum;Jung, Jae Yun;Kwak, Young Ho
    • Journal of Trauma and Injury
    • /
    • v.27 no.2
    • /
    • pp.13-19
    • /
    • 2014
  • Purpose: In general, X-ray examinations are not recommended for radial head subluxation (pulled elbow) patients. The purpose of this study was to determine the frequency of X-ray examinations and to investigate the factors associated with the decision to perform an X-ray examination on a patient with a pulled elbow. Methods: Patients who visited the pediatric emergency department (ED) of one tertiary hospital from January 1, 2011, to December 31, 2012, with a diagnosis of radial head subluxation at discharge were enrolled in this study. Through retrospective chart reviews, factors that could have influenced the decision to perform an X-ray examination and their statistical relevance were analyzed. Results: A total 308 patients were enrolled, and 101 patients (32.8%) underwent X-ray examinations. Among the 252 patients with a typical pulled elbow, 65 underwent X-ray examination. This result showed statistical significance compared to atypical pull-elbow group (25.8% vs. 64.3%, p<0.001). Factors associated with the decision to perform an X-ray examination were analyzed using the Chi-square test and the Fisher's exact test. The mechanism of injury and consultation with an orthopedic surgeon (p=0.001) showed statistical significance. In the multivariable logistic regression, the odds ratio (OR) for the injury mechanism was 4.7 (95% CI: 1.8~8.8, p<0.001) and that for consultation with an orthopedic surgeon was 8.0 (95% CI: 1.6~40.7, p=0.004). Conclusion: One third of patients with a pulled elbow underwent X-ray examination, and patients with an atypical mechanism of injury underwent more frequent X-ray examinations than did patients with a typical mechanism of injury. The factors that could have influenced the decision to perform an X-ray examination were mechanism of injury and consultation with an orthopedic surgeon.

Unleashing the Potential of Vision Transformer for Automated Bone Age Assessment in Hand X-rays (자동 뼈 연령 평가를 위한 비전 트랜스포머와 손 X 선 영상 분석)

  • Kyunghee Jung;Sammy Yap Xiang Bang;Nguyen Duc Toan;Hyunseung Choo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2023.05a
    • /
    • pp.687-688
    • /
    • 2023
  • Bone age assessment is a crucial task in pediatric radiology for assessing growth and development in children. In this paper, we explore the potential of Vision Transformer, a state-of-the-art deep learning model, for bone age assessment using X-ray images. We generate heatmap outputs using a pre-trained Vision Transformer model on a publicly available dataset of hand X-ray images and show that the model tends to focus on the overall hand and only the bone part of the image, indicating its potential for accurately identifying the regions of interest for bone age assessment without the need for pre-processing to remove background noise. We also suggest two methods for extracting the region of interest from the heatmap output. Our study suggests that Vision Transformer holds great potential for bone age assessment using X-ray images, as it can provide accurate and interpretable output that may assist radiologists in identifying potential abnormalities or areas of interest in the X-ray image.

Development of the Imaging Optical System for the 545 nm Fluorescent Plate of X-ray (X선용 545 nm 형광판 결상광학계 개발)

  • Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.17-22
    • /
    • 2008
  • To develop an imaging optical system for the 545 nm fluorescent plate of X-ray. Methods: We designed and manufactured a new imaging optical system for the 545 nm fluorescent plate of X-ray by Sigma 2000 program after deciding the design comparison standards referred to Canon CX2-70 model. Results: The characteristics of the new imaging optical system for the 545 nm fluorescent plate of X-ray have the magnification of -0.225x, the image field size of $90mm{\times}90mm$, and the 0.033 mm resolution line width at the 30% MTF value criterion. These mean that the new model has a capability of deciphering for the more large screen and the resolution of deciphering is superior to that of Canon CX2-70 model. Also the image side NA (-0.196) of the new model is about $\sqrt{2}$ times than that (-0.139) of CX2-70 and the object side NA (0.044) of the new model is about 2 times than that (0.022) of CX2-70. These mean that the sensitivity of the film in the new design model is able to be increased to about 4 times and there is the possibility of reducing the bombed time of X-ray to 1/4 times. Conclusions: We could design and manufacture the imaging optical system for the 545 nm fluorescent plate of X-ray having the possibility of reducing the bombed time of X-ray to 1/4 times in comparision to Canon CX2-70 model, the characteristics of which have the image field size of $90mm{\times}90mm$ and the MTF of 30% or more at 15 lines/mm criterion.

  • PDF

Simulation of an X-ray Fresnel Zone Plate with Nonideal Factors

  • Chen, Jie;Fan, Quanping;Wang, Junhua;Yuan, Dengpeng;Wei, Lai;Zhang, Qiangqiang;Liao, Junsheng;Xu, Min
    • Current Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.9-15
    • /
    • 2020
  • Fresnel zone plates have been widely used in many applications, such as x-ray telescopes, microfluorescence, and microimaging. To obtain an x-ray Fresnel zone plate, many fabrication methods, such as electron-beam etching, ion-beam etching and chemical etching, have been developed. Fresnel zone plates fabricated by these methods will inevitably lead to some nonideal factors, which have an impact on the focusing characteristics of the zone plate. In this paper, the influences of these nonideal factors on the focusing characteristics of the zone plate are studied systematically, by numerical simulations based on scalar diffraction theory. The influence of the thickness of a Fresnel zone plate on the absolute focusing efficiency is calculated for a given incident x-ray's wavelength. The diffraction efficiency and size of the focal spot are calculated for different incline angles of the groove. The simulations of zone plates without struts, with regular struts, and with random struts are carried out, to study the effects of struts on the focusing characteristics of a zone plate. When a Fresnel zone plate is used to focus an ultrashort x-ray pulse, the effect of zone-plate structure on the final pulse duration is also discussed.

An Effective Extraction Algorithm of Pulmonary Regions Using Intensity-level Maps in Chest X-ray Images (흉부 X-ray 영상에서의 명암 레벨지도를 이용한 효과적인 폐 영역 추출 알고리즘)

  • Jang, Geun-Ho;Park, Ho-Hyun;Lee, Seok-Lyong;Kim, Deok-Hwan;Lim, Myung-Kwan
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.7
    • /
    • pp.1062-1075
    • /
    • 2010
  • In the medical image application the difference of intensity is widely used for the image segmentation and feature extraction, and a well known method is the threshold technique that determines a threshold value and generates a binary image based on the threshold. A frequently-used threshold technique is the Otsu algorithm that provides efficient processing and effective selection criterion for choosing the threshold value. However, we cannot get good segmentation results by applying the Otsu algorithm to chest X-ray images. It is because there are various organic structures around lung regions such as ribs and blood vessels, causing unclear distribution of intensity levels. To overcome the ambiguity, we propose in this paper an effective algorithm to extract pulmonary regions that utilizes the Otsu algorithm after removing the background of an X-ray image, constructs intensity-level maps, and uses them for segmenting the X-ray image. To verify the effectiveness of our method, we compared it with the existing 1-dimensional and 2-dimensional Otsu algorithms, and also the results by expert's naked eyes. The experimental result showed that our method achieved the more accurate extraction of pulmonary regions compared to the Otsu methods and showed the similar result as the naked eye's one.

Correlation Study between Cervical X-ray Sagittal Parameters and Chuna Posture Analysis Results (경추 X-ray 시상면 지표와 추나체형분석 결과와의 상관성 연구)

  • Park, Joo-Sung;Lim, Hyung-Ho;Song, Yun-Kyung
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.30 no.2
    • /
    • pp.125-137
    • /
    • 2020
  • Objectives The purpose of this study was to examine how changes in the cervical spine correlate with body posture changes in the whole body, and to find out the significance of complementary clinical application X-ray and Chuna posture analysis. Methods From January 1, 2019 to October 31, 2019, the results of 27 patients with pain in the vertebral region were analysed in accordance with the results of cervical X-ray and Chuna posture analysis. In order to confirm the significance of Chuna posture analysis results, the survey of 187 Chuna standard curriculum instruction qualification certifiers was conducted and the responses of 47 of them were analyzed. Results The occiput-atlas cline angle increases in both hypolordosis/hyperlordosis groups based on cervical lordosis angle, and increases further than in the hyperlordosis group. There were significant correlations between the changes in the cervical spine and the body posture changes in the whole body. There were no significant differences between cervical X-ray sagittal parameters and the body posture analysis parameters based on the patient's major disease codes. Conclusions As a result of conducting a survey on the clinical importance of the body posture analysis parameters, the importance of cervical parameters was verified. Changes in the cervical spine may not only cause other changes in the cervical region, but also affect the body posture changes in the whole body. The complementary application of X-ray and Chuna posture analysis results is helpful in clinical diagnosis and treatment of musculoskeletal disorders.