• Title/Summary/Keyword: X-ray method

Search Result 4,422, Processing Time 0.049 seconds

Individualized Determination of Lower Margin in Pelvic Radiation Field after Low Anterior Resection for Rectal Cancer Resulted in Equivalent Local Control and Radiation Volume Reduction Compared with Traditional Method (하전방 절제술을 시행한 직장암 환자에서 방사선조사 영역 하연의 개별화)

  • Park Suk Won;Ahn Yong Chan;Huh Seung Jae;Chun Ho Kyung;Kang Won Ki;Kim Dae Yong;Lim Do Hoon;Noh Young Ju;Lee Jung Eun
    • Radiation Oncology Journal
    • /
    • v.18 no.3
    • /
    • pp.194-199
    • /
    • 2000
  • Purpose : Then determining the lower margin of post-operative pelvic radiation therapy field according to the traditional method (recommended by Gunderson), the organs located in the low pelvic cavity and the perineum are vulnerable to unnecessary radiation. This study evaluated the effect of individualized determination of the lower margin at 2 cm to 3 cm below the anastomotic site on the failure patterns. Materials and Methods . Authors included ぉ patients with modified Astler-Coiler (MAC) stages from B2 through C3, who received low anterior resection and post-operative pelvic radiation therapy from Sept. 1994 to May 1998 at Samsung Medical Center, Sungkyunkwan University. The numbers of male and female patients were 44 and 44, and the median age was 57 years (range: 32-81 years). Three field technique (posterior-anterior and bilateral portals) by 6, 10, 15 MV X-rays was used to deliver 4,500 cGy to the whole pelvis followed by Sn cGy's small field boost to the tumor bed over 5.5 weeks. Sixteen patients received radiation therapy by traditional field margin determination, and the lower margin was set either at the low margin of the obturator foramen or at 2 cm to 3 cm below the anastomotic site, whichever is lower. In 72 patients, the lower margin was set at 2 cm to 3 cm below the anastomotic site, irrespectively of the obturator foramen, by which the reduction of radiation volume was possible in 55 patients ($76\%$). Authors evaluated and compared survival, local control, and disease-free survival rates of these two groups. Results : The median follow-up period was 27 months (range : 7-58 months). MAC stages B2 in 32($36\%$), B3 in 2 ($2\%$), Cl in 2 ($2\%$), C2 in 50 ($57\%$), and C3 in 2 ($2\%$) Patients, respectively. The entire patients' overall survival rates at 2 and 4 years were $94\%$ and $68\%$, respectively, and disease-free survival rates at 2 and 4 years were $86\%$ and $58\%$, respectively. The first failure sites were local only in 4, distant only in 14, and combined local and distant in 1 patient, respectively. There was no significant difference with respect to local control and disease-free survival rates ( p=0.42, p=0.68) between two groups of different lower margin determination policies. Conclusion : The new concept in the individualized determination of the lower margin depending on the anastomotic site has led to the equivalent local control and disease-free survival rates, and is expected to contribute to the reduction of unnecessary radiation-related morbidity by reduction of radiation volume, compared with the traditional method of lower margin determination.

  • PDF

A Study on the Identification of Animal Hair in Food (식품 중 동물 털 이물의 판별법 연구)

  • Lee, Jae-Hwang;Park, Young-Eun;Lim, Byung-Chul;Kim, Ju-Shin;Choi, Jong-Hyun;Kang, Tae Sun;Lee, Jin-Ha;Kwon, Kisung
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.1
    • /
    • pp.57-63
    • /
    • 2017
  • Foreign materials with a variety of types and sizes are found in food; thus, extraordinary efforts and various analytical methods are required to identify the types of foreign materials and to find out accurate causes of how they unintentionally enter food. In this study, human, cow, pig, mouse, duck, goose, dog, and cat were chosen as various types of animal hairs because they can be frequently incorporated into food during its production or consumption step. We morphologically analyzed them using stereoscopic, optical, SUMP method, and scanning electron microscopes, showing differences in each type. In addition, X-ray fluorescence spectrometer (XRF) was used to analysis chemical compositions ($^{11}Na{\sim}^{92}U$, Mass%) of samples. As a result, we observed that mammalian hairs were mainly composed of sulfur. Organic compounds of samples were further analyzed by fourier transform infrared spectroscopy (FT-IR) that can compare spectra of given materials; however, this method did not show significant differences in each sample. In this study, we suggest a rapid method for the identification of the causes and types of foreign materials in food.

THE REACTION OF BONE REGENERATE TO THE VARIOUS FORCE RATIO AND PERIODS ON DISTRACTION OSTEOGENESIS WITH COMBINED DISTRACTION FORCE AND COMPRESSION FORCE (수축력과 신장력을 병용한 골신장술에서의 다양한 힘의 비와 부여시기에 따른 신연골 반응)

  • Kim, Uk-Kyu;Shin, Sang-Hun;Chung, In-Kyo;Kim, Cheol-Hun;Huo, Jun;Yun, Il
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.5
    • /
    • pp.403-414
    • /
    • 2005
  • The purpose of this study was to identify the effectiveness of the modified distraction osteogenesis (DO) method with the concept of overdistraction and compression stimulation which have been previously suggested by the authors in 2002 and to explore the optimal distraction-compression ratio and appropriate latency period for the compression force application during consolidation. The experimental specimens were assessed with radiography, histologic findings, and dual energy x-ray absorptiometry (DEXA) after the conventional DO method and the modified DO technique had been applied on rat mandibles. Total 60 rats were used for the study. In experimental group of 54 adult rats, mandibular osteotomies between the first and second molar areas were performed and customized external distractors were applied. The surgeries on 6 rats of control group also were done with same osteotomy technique and DO device application. Final amount of distraction was set-up as 2 mm on both groups. But, in a experimental group of 54 rats, distraction osteogenesis with a compression force were performed with the different distraction-compression ratio and variant latency periods for compression. The three ratio-subgroups were made as distraction 4 mm group with compression 2 mm, distraction 3 mm group with compression 1 mm, and distraction 2.5 mm group with compression 0.5 mm. In addition, The three subgroups with 3, 7, 11 days latency period prior compression were allocated on each ratio-subgroups. Total 9 subgroups consisted of 6 rats on each subgroup. In control group of 6 rats, conventional distraction technique were routinely performed. The rats of control groups were sacrificed on postoperative 3, 6 weeks after 2 mm distraction. The rats in the experimental groups also were sacrificed on the same euthanasia days of control groups to compare the wound healing. Final available specimens were 55 rats except 5 due to osteomyelitis, device dislodgement. Distraction-compression combined group on 6 weeks generally had showed increased bone mineral density than the same period group of conventional distraction technique on the DEXA study. More matured lamellar bone state and extended trabecular pattern in the combined group than those of control group were also observed in the histologic findings on 6 weeks. In the distraction-compression combined groups, the bone density of 2.5 mm distraction subgroups with 0.5 mm compression showed the highest value on the DEXA study among various force ratio groups. In the distraction-compression combined groups, the bone density of 3 day latency period subgroups showed the highest value on the DEXA study among various latency period groups for the compression application. From this study, we could deduce that 1/5 force ratio for the compression versus distraction, 3 day latency period prior compression application would be the most effective condition if modified distraction osteogenesis technique might be applicable. The modified DO method with a compression force may improve the quality of bone regenerate and shorten total treatment period in comparison with conventional DO technique clinically.

Re-conservation of the Iron Sword with Ring Pommel with Three-Pointed Leaf Decoration Excavated from Tomb No. 55 at the Dalseong Ancient Tomb Complex in Daegu and a Study of Its Production Method (대구 달성 55호분 출토 삼엽문이자태도의 재보존처리와 제작 기법 연구)

  • Lee, Huisung;Huh, Ilkwon;Ro, Jihyun;Park, Seungwon
    • Conservation Science in Museum
    • /
    • v.24
    • /
    • pp.1-16
    • /
    • 2020
  • This paper presents the process of re-conservation and the results of research on the production method of the Iron Sword with Ring Pommel with Three-Pointed Leaf Decoration, one of the excavation findings from Tomb No. 55 in the Dalseong Ancient Tomb Complex in Daegu. This iron sword is a double weapon with two large swords housed within a single sheath. Four smaller swords are attached to the surface of the sheath, two on the upper portion and the other two below. It is the only such two-in-one weapon excavated intact thus far from an ancient Korean tomb. The records show that it underwent conservation treatment twice in the past. In this study, it was subjected to conservation treatment again to replace the stiffener in some cracking areas, and its material, composition, and production method were analyzed by CT, XRF analysis, and stereoscopic microscopy. The sword is mainly made of copper, but the golden component contains both gold and mercury, which suggests that the copper was plated in gold using mercury amalgamation. The examination of the production methods indicates that it was intended more to demonstrate the authority of its owner rather than to serve any practical use. The two upper small swords on the sheath were made in the same manner as the main swords, and the two small lower swords were cut from a single metal sheet. The sheath was made by cutting two metal sheets. Supports were used to attach the two small swords to the upper portion of the sheath, while the lower portion of the sheath was slit to allow the other two small swords to be inserted into it. The ring pommels of the main swords have a three-pointed leaf decoration. As for the other designs, the handle of the main sword features a series of semicircles, the decorative bands on the sheath have waves in dots, and the fish tail of the sheath shows diagonal lines of dots.

Lung Biopsy after Localization of Pulmonary Nodules with Hook Wire (Hook Wire를 이용한 폐결절의 위치선정 및 생검)

  • Kim, Jin-Sik;Hwang, Jae-Joon;Lee, Song-Am;Lee, Woo-Surng;Kim, Yo-Han;Kim, Jun-Seok;Chee, Hyun-Keun;Yi, Jeong-Geun
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.681-686
    • /
    • 2010
  • Background: A chest computed-tomography has become more prevalent so that it is more common to detect small sized pulmonary nodules that have not been found in previous simple chest x-ray. If those detected nodules are undersized or located in pulmonary parenchyma, it is difficult to accomplish a biopsy since it is vulnerable to explore them either grossly or digitally. Thus, in our hospital, a thoracoscopic pulmonary wedge resection was performed after locating a lesion by means of hook wire with CT-guided. Material and Method: 31 patients (17 males and 14 female patients) from December in 2006 to June in 2010 became our subjects; their 34 pulmonary nodules were subjected to the thoracoscopic pulmonary wedge resection after locating a lesion by means of hook wire with CT-guided. Also we analyzed a possibility of hook wire dislocation, a frequency of conversion to open thoracotomy, time consumed to operation after location of a lesion, operation time, post operation complication, and histological diagnosis of the lesion. Result: 12 of 34 cases were ground glass lesion, whereas 22 cases of them were solitary pulmonary lesion. The median value of the lesion was 8mm in size (range: 3 to 23 mm), while the median value was 12.5 mm in depth (range: 1 to 34 mm). The median value of time consumed from location of the lesion to anesthetic induction was 86.5 minutes (41~473 minutes); furthermore the mean value of operation time was 103 minutes (25~345 minutes). Intrathoracic wire dislocation was found in one case, but a target lesion was successfully excised. Open thoracotomy was performed in four cases due to pleural adhesion. However, there was no case of conversion to open thoracotomy due to failure to detect a target lesion. In histological diagnosis, metastatic cancer were found in 15 cases, which were the most common, primary lung cancer were in 9 cases, non-specific inflammation were in 3 cases, tuberculosis inflammation were in 2 cases, lymph nodes were in 2 cases, active tuberculosis were in 1 case, atypical adenomatous hyperplasia was in 1 case and normal lung parenchymal finding was in 1 case, respectively. Conclusion: In our hospital, in order to accomplish a precise histological diagnosis of ground-glass lesion and pulmonary nodules in lung parenchyma, location of pulmonary nodules were exactly located with hook wire under chest computed-tomography, which was followed by lung biopsy. We concluded that this was an accurate, minimally invasive and valuable method to minimize the complications and increase of cost of medical service provided.

The Comparative Analysis of Exposure Conditions between F/S and C/R System for an Ideal Image in Simple Abdomen (복부 단순촬영의 이상적 영상구현을 위한 F. S system과 C.R system의 촬영조건 비교분석)

  • Son, Sang-Hyuk;Song, Young-Geun;Kim, Je-Bong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.37-43
    • /
    • 2007
  • 1. Purpose : This study is to present effective exposure conditions to acquire the best image of simple abdomen in Film Screen (F.S) system and Computed Radiography (C.R) system. 2. Method : In the F.S system, while an exposure condition was fixed as 70kVp, images of a patients simple abdomen were taken under the different mAs exposure conditions. Among these images, the best one was chosen by radiologists and radiological technologists. In the C.R system, the best image of the same patient was acquired with the same method from the F.S system. Both characteristic curves from F.S system and C.R system were analyzed. 3. Results : In the F.S system, the best exposure condition of simple abdomen was 70kVp and 20mAs. In the CR system, with the fixed condition at 70kVp, the image densities of human organs, such as liver, kidney, spleen, psoas muscle, lumbar spine body and iliac crest, were almost same despite different environments (3.2mAs, 8mAs, 12mAs, 16mAs and 20mAs). However, when the exposure conditions were over or under (below) 12mAs, the images between the abdominal wall and the directly exposed part became blurred because the gap of density was decreased. In the C.R system, while the volume of mAs was decreased, an artifact of quantum mottle was increased. 4. Conclusion : This study shows that the exposure condition in the C.R system can be reduced 40% than in the F.S system. This paper concluded that when the exposure conditions are set in CR environment, after the analysis of equipment character, such as image processing system(EDR : Exposure Data Recognition processing), PACS and so on, the high quality of image with maximum information can be acquired with a minimum exposure dose.

  • PDF

The effect of Nutrient Intake and Past Dairy Products Consumption on Bone Mineral Density of Postmenopausal of Korean Women (과거의 우유 및 유제품의 섭취가 한국노인의 골밀도에 미치는 영향)

  • 강은주
    • The Korean Journal of Food And Nutrition
    • /
    • v.11 no.1
    • /
    • pp.87-98
    • /
    • 1998
  • This study was conducted to investigate Osteoporosis on the effect of dietary factors and past young age period's dairy products consumption on BMD in 170 postmenopausal Korean women without diagnosed disease. Bone mineral density(BMD) of lumbar spine was investigated by dual energy X-ray absorptiometry. Dietary assesment of the subjects were measured by Cognitive Food Frequency Recall method. The measurements of group average were 57.9kg of body weight, 36.73 of BMI(Body Mass Index), 2103.3㎉ of energy, 638.7mg of dietary calcium, 70.3g of protein, and 10.58mg of iron. Nutrient intake levels were similar to or more than the level of Korean Recommended Dietary Allowances. Bone Mineral Density(BMD) of Lumbar spine(L2-L4) of group average was 0.912g/$\textrm{cm}^2$, and under 50 yr's 1,02g/$\textrm{cm}^2$, 50~54 yr's 0.92g/$\textrm{cm}^2$, 55~59 yr's 0.85g/$\textrm{cm}^2$, over 60 yr's 0.85g/$\textrm{cm}^2$, had been getting low degree on aging. BMD of the Lumbar spine was positively correlated with calorie, body weight, dietary calcium, protein, phosphorus and serum albumin. Past dairy products consumption experiment was highly significant on BMD in teenage period(R square = 26, p-value 0.0031). Particularly in over 60 yr group, the correlations between BMD and past dairy products consumption in teenage period had shown highly significance(r=0.48, p<0.02). 55~59 yr age group had also positive correlation(R squae = 0.29, p<0.05). This results confirm that the most effective way of preventing osteoporosis and the fractures is to maximize peak bone mass in early life and to minimize bone loss through the balanced intake of Ca and other nutrients and regular physical activity.

  • PDF

CT Measurement of Diameter and Dimension of the Trachea in Normal Korean Adults (흥부 전산화단층촬영을 이용한 한국성인의 기관내경과 단면적의 측정)

  • Han, Jae-Youl;Kim, Kwang-Ho;Lee, Gun;Kim, Hyung-Jin;Cho, Soon-Koo;Sun, Kyung
    • Journal of Chest Surgery
    • /
    • v.34 no.7
    • /
    • pp.534-538
    • /
    • 2001
  • Background: Knowledge of size and morphology of the normal trachea is important for airway management and tracheal reconstruction. Conventional radiography is a simple method used to measure the tracheal diameter, but it is not accurate because of the artifacts related to image magnification and overlapping by the shoulder. The purpose of this study was to provide the normal values of the tracheal size and anatomy in Korean adults using Computerized Topography. Material and Method: There were 43 men and 34 women included in this study. They were divided into three age groups(group 1, 20-39 years ; group 2, 40-59 yeas , groups 3, $\geq$60 years). The anteroposterior and transverse diameters and cross - sectional areas of the trachea were measured at the level of the thoracic inlet(Level 1) and the aortic arch(Level 2). These values obtained at each level were compared between age groups and sexes. Result: In 43 men, the anteroposterior / transverse diameters(mean SD in millimeters) of the trachea at levels 1 and 2 were 19.95$\pm$2.99 / 17.72$\pm$2.13 and 19.77$\pm$2.57 / 18.02$\pm$2.19, respectively. In 34 women, those values at levels 1 and 2 were 15.56$\pm$2.12 / 14.18$\pm$2.07 and 15.35$\pm$1.82 / 15.00$\pm$1.60, respectively. At both levels, the anteroposterior and transverse diameters were significantly greater in men than in women (p<0.05). The cross-sectional area of the trachea at levels 1 and 2 were 279.14$\pm$61.37 / 281.93$\pm$63.97 $\textrm{mm}^2$ in men and 173.29$\pm$35.81 / 181.88$\pm$34.74 in women, respectively. They also showed significantly greater values in men than in women(P<0.05). There was no significant difference in diameters and cross-sectional areas of the trachea between age groups. Conclusion: There are significant differences in the internal diameter and cross- sectional area of the trachea between men and women in normal Korean adults, while the age difference was insignificant. We believed CT is a relatively accurate and safe way to measure the internal diameter and cross-sectional areas of the trachea.

  • PDF

SURFACE CHARACTERISTICS AND BIOACTIVITY OF ANODICALLY OXIDIZED TITANIUM SURFACES (양극산화에 의한 티타늄 산화막의 표면 특성 및 생체 활성에 관한 연구)

  • Lee, Sang-Han;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.85-97
    • /
    • 2007
  • Statement of problem: Recently, anodic oxidation of cp-titanium is a popular method for treatment of titanium implant surfaces. It is a relatively easy process, and the thickness, structure, composition, and the microstructure of the oxide layer can be variably modified. Moreover the biological properties of the oxide layer can be controlled. Purpose: In this study, the roughness, microstructure, crystal structure of the variously treated groups (current, voltage, frequency, electrolyte, thermal treatment) were evaluated. And the specimens were soaked in simulated body fluid (SBF) to evaluate the effects of the surface characteristics and the oxide layers on the bioactivity of the specimens which were directly related to bone formation and integration. Materials and methods: Surface treatments consisted of either anodization or anodization followed thermal treatment. Specimens were divided into seven groups, depending on their anodizing treatment conditions: constant current mode (350V for group 2), constant voltage mode (155V for group 3), 60 Hz pulse series (230V for group 4, 300V for group 5), and 1000 Hz pulse series (400V for group 6, 460V for group 7). Non-treated native surfaces were used as controls (group 1). In addition, for the purpose of evaluating the effects of thermal treatment, each group was heat treated by elevating the temperature by $5^{\circ}C$ per minute until $600^{\circ}C$ for 1 hour, and then bench cured. Using scanning electron microscope (SEM), porous oxide layers were observed on treated surfaces. The crystal structures and phases of titania were identified by thin-film x-ray diffractmeter (TF-XRD). Atomic force microscope (AFM) was used for roughness measurement (Sa, Sq). To evaluate bioactivity of modified titanium surfaces, each group was soaked in SBF for 168 hours (1 week), and then changed surface characteristics were analyzed by SEM and TF-XRD. Results: On basis of our findings, we concluded the following results. 1. Most groups showed morphologically porous structures. Except group 2, all groups showed fine to coarse convex structures, and the groups with superior quantity of oxide products showed superior morphology. 2. As a result of combined anodization and thermal treatment, there were no effects on composition of crystalline structure. But, heat treatment influenced the quantity of formation of the oxide products (rutile / anatase). 3. Roughness decreased in the order of groups 7,5,2,3,6,4,1 and there was statistical difference between group 7 and the others (p<0.05), but group 7 did not show any bioactivity within a week. 4. In groups that implanted ions (Ca/P) on the oxide layer through current and voltage control, showed superior morphology, and oxide products, but did not express any bioactivity within a week. 5. In group 3, the oxide layer was uniformly organized with rutile, with almost no titanium peak. And there were abnormally more [101] orientations of rutile crystalline structure, and bonelike apatite formation could be seen around these crystalline structures. Conclusion: As a result of control of various factors in anodization (current, voltage, frequency, electrolytes, thermal treatment), the surface morphology, micro-porosity, the 2nd phase formation, crystalline structure, thickness of the oxide layer could be modified. And even more, the bioactivity of the specimens in vitro could be induced. Thus anodic oxidation can be considered as an excellent surface treatment method that will able to not only control the physical properties but enhance the biological characteristics of the oxide layer. Furthermore, it is recommended in near future animal research to prove these results.

Development of Quality Assurance Program for the On-board Imager Isocenter Accuracy with Gantry Rotation (갠트리 회전에 의한 온-보드 영상장치 회전중심점의 정도관리 프로그램 개발)

  • Cheong, Kwang-Ho;Cho, Byung-Chul;Kang, Sei-Kwon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.212-223
    • /
    • 2006
  • Positional accuracy of the on-board imager (OBI) isocenter with gantry rotation was presented in this paper. Three different type of automatic evaluation methods of discrepancies between therapeutic and OBI isocenter using digital image processing techniques as well as a procedure stated in the customer acceptance procedure (CAP) were applied to check OBI isocenter migration trends. Two kinds of kV x-ray image set obtained at OBI source angle of $0^{\circ},\;90^{\circ},\;180^{\circ},\;270^{\circ}$ and every $10^{\circ}$ and raw projection data for cone-beam CT reconstruction were used for each evaluation method. Efficiencies of the methods were also estimated. If a user needs to obtain an isocenter variation map with full gantry rotation, a method taking OBI image for every $10^{\circ}$ and fitting with 5th order polynomial was appropriate. However for a mere quality assurance (QA) purpose of OBI isocenter accuracy, it was adequate to use only four OBI Images taken at the OBI source angle of $0^{\circ},\;90^{\circ},\;180^{\circ}\;and\;270^{\circ}$. Maximal discrepancy was 0.44 mm which was observed between the OBI source angle of $90^{\circ}\;and\;180^{\circ}$ OBI isocenter accuracy was maintained below 0.5 mm for a year. Proposed QA program may be helpful to Implement a reasonable routine QA of the OBI isocenter accuracy without great efforts.

  • PDF