Comparison of Parallel and Fan-Beam Monochromatic X-Ray CT Using Synchrotron Radiation

  • Toyofuku, Fukai;Tokumori, Kenji;Kanda, Shigenobu;Ohki, Masafumi;Higashida, Yoshiharu;Hyodo, Kazuyuki;Ando, Masami;Uyama, Chikao
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.407-410
    • /
    • 2002
  • Monochromatic x-ray CT has several advantages over conventional CT, which utilizes bremsstrahlung white x-rays from an x-ray tube. There are several methods to produce such monochromatic x-rays. The most popular one is crystal diffraction monochromatization, which has been commonly used because of the fact that the energy spread is very narrow and the energy can be changed continuously. The alternative method is the use of fluorescent x-ray, which has several advantages such as large beam size and fast energy change. We have developed a parallel-beam and a fan-beam monochromatic x-ray CT, and compared some characteristics such as accuracy of CT numbers between those systems. The fan beam monochromatic x-rays were generated by irradiating target materials by incident white x-rays from a bending magnet beam line NE5 in 6.5 GeV Accumulation Ring at Tukuba. The parallel beam monochromatic x-rays were generated by using a silicon double crystal monochromator at the bending magnet beam line BL-20BM in Spring-8. A Cadmium telluride (CdTe) 256 channel array detector with 512mm sensitive width capable of operating at room temperature was used in the photon counting mode. A cylindrical phantom containing eight concentrations of gadolinium was used for the fan beam monochromatic x-ray CT system, while a phantom containing acetone, ethanol, acrylic and water was used for the parallel monochromatic x-ray CT system. The linear attenuation coefficients obtained from CT numbers of those monochromatic x-ray CT images were compared with theoretical values. They showed a good agreement within 3%. It was found that the quantitative measurement can be possible by using the fan beam monochromatic x-ray CT system as well as a parallel beam monochromatic X-ray CT system.

  • PDF

A Clinical Study on Growth and Development of Children Based on Their Bone Age Measured by Hand's X-ray Image and Calcaneus's Ultrasonic Image (수완부골의 X-ray 영상 및 종골의 초음파 영상에서 측정한 골연령을 통한 소아성장에 관한 임상연구)

  • Yun, Hye-Jin;Seo, Jung-Min;Kang, Mi-Sun;Baek, Jung-Han
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.22 no.2
    • /
    • pp.155-170
    • /
    • 2008
  • Objectives : The purpose of this study was to have better data and to make efficient clinical reviews about children's growth based on two methods; X-ray of hand, and ultrasound of calcaneus. Methods : The study was composed of 100 patients(50 of boys and 50 of girls) who visited in department of pediatrics, O O university oriental hospital considering growth and their development. Bone age was measured by the TW3 method's RUS score in simple X-ray image of hand and bone density through ultrasonic image of calcaneus. To predict children's estimated height, their parent's height, bone age, and present height's percentile was measured. Results and Conclusions : 1. The bone age results from X-ray image of hand and ultrasonic image of calcaneus were correlated. Younger children have older bone age from hand's X-ray than the one from calcaneus's ultrasound. Older children have older bone age from calcaneus's ultrasound than one from hand's X-ray. 2. Predicted adult height by bone age(BH) of hand's X-ray and BH of calcaneus's ultrasound were correlated, but predicted adult height by inheritance(IH) was not correlated with others. 3. Bone age and predicted adult height were correlated with age, height, weight, BMI, and especially with age and height. 4. Measuring bone age by X-ray image of hand and ultrasonic image of calcaneus was simple and effective way of estimating children's growth and development.

  • PDF

Wear and Implantation Tilt Measurements using X-ray and CAD (X-ray영상과 CAD를 이용한 인공고관절의 마모 및 식립각 측정법)

  • Lee, Jong Min;Lee, Yeon Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.107-114
    • /
    • 2018
  • Long-term complications such as loosening, wear, osteolytic lesion and granulomatous reaction by foreign bodies can occur, after total hip arthroplasty. The implantation alignment effects dislocation and wear, according to its amount and direction. Wear particles in total hip arthroplasty brings about biochemical complications such as osteolysis or send wear. In this sense, it is important to regularly check wear and alignment of total hip replacement. Because the wear in followup of 10 years may remain in a small amount, like a 1 or 2 mm generally, somewhat precise measurement tool has to be established. The wear and alignment measurement softwares commercially available currently lack in project saving or reproducibility. This study suggests a reliable method for the measurement using an X-ray image and a CAD software. The proposed method can be executed only if having a CAD software under most of current general clinical radiographical environment. The proposed was revealed through tests for the method to have accuracy of 0.06 mm with precision of 0.05 mm for wear measurement, and precision of 0.27 degrees for tilt measurement.

The MTF Measurement of the Conventional X-ray System by using the Computed Radiography (CR을 이용한 일반촬영장치의 MTF 측정)

  • Kim, Chang-Bok
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.111-115
    • /
    • 2005
  • The quality of image from the system that creates medical images by using X-ray depends on the various different reasons such as the X-ray generator, the subject and the image transmission medium. In other words, thereare various factors existing that can influence on the quality of image from the moment when the X-ray is generated and until the final image is created. Therefore, the operator who creates images at the clinical site should make continuous evaluation and observation from the final image. There are various methods of evaluating the medical images, but it is assumed that the MTF measurement method can be suitable for measuring actual or effective resolution. So in this study, the MTF measurement method by using X-ray film has been avoided and the MTF features according to the deterioration of the X-ray system have been measured by using the software (the program used Borland C++ builder software and LEAD tools software) that can measure the MTF of the digital medical images. As the result of this measurement, it has been found out through the MTF graph that the resolution and sharpness from the old x-ray generator with a many years of using and many numbers of times of using were deteriorated for the quality of image comparing to those from the new system. Also a simple and easy measurement method for the MTF from the digital medical images can be obtained in this study.

  • PDF

CORRELATION FUNCTIONS OF THE ABELL, APM, AND X-RAY CLUSTERS OF GALAXIES

  • LEE SUNGHO;PARK CHANGBOM
    • Journal of The Korean Astronomical Society
    • /
    • v.35 no.3
    • /
    • pp.111-121
    • /
    • 2002
  • We have measured the correlation functions of the optically selected clusters of galaxies in the Abell and the APM catalogs, and of the X-ray clusters in the X-ray-Brightest Abell-type Clusters of galaxies (XBACs) catalog and the Brightest Clusters Sample (BCS). The same analysis method and the same method of characterizing the resulting correlation functions are applied to all observational samples. We have found that the amplitude of the correlation function of the APM clusters is much higher than what has been previously claimed, in particular for richer subsamples. The correlation length of the APM clusters with the richness R $\ge$ 70 (as defined by the APM team) is found to be $r_0 = 25.4_{-3.0}^{+3.1}\;h^{-1}$ Mpc. The amplitude of correlation function is about 2.4 times higher than that of Croft et al. (1997). The correlation lengths of the Abell clusters with the richness class RC $\ge$ 0 and 1 are measured to be $r_0 = 17.4_{-1.1}^{+1.2}$ and $21.0_{-2.8}^{+2.8}\;h^{-1}$ Mpc, respectively, which is consistent with our results for the APM sample at the similar level of richness. The richness dependence of cluster correlations is found to be $r_0= 0.40d_c + 3.2$ where $d_c$ is the mean intercluster separation. This is identical in slope with the Bahcall & West (1992)'s estimate, but is inconsistent with the weak dependence of Croft et al. (1997). The X-ray bright Abell clusters in the XBACs catalog and the X-ray selected clusters in the BCS catalog show strong clustering. The correlation length of the XBACs clusters with $L_x {\ge}0.65{\times} 10^{44}\;h^{-2}erg\;s^{-1}$ is $30.3_{-6.5}^{+8.2}\;h^{-1}$ Mpc, and that of the BCS clusters with $L_x {\ge}0.70{\times} 10^{44}\;h^{-2}erg\;s^{-1}$ is $30.2_{-8.9}^{+9.8}\;h^{-1}$ Mpc. The clustering strength of the X-ray clusters is much weaker than what is expected from the optical clusters.

Analysis of Heat Generation Induced by Electron Impact in X-Ray Tube Using FEM and Monte Carlo Method (유한요소법과 몬테카를로법을 이용한 X선 튜브에서 전자빔 충격에 의한 열 발생 해석)

  • Kim, Heungbae;Yoo, Tae Jae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.4
    • /
    • pp.387-394
    • /
    • 2015
  • We analyze heat generation as well as temperature distribution induced by accelerated electron impact on a target in a closed x-ray tube. For the sake of accuracy, we use Monte carlo analysis. This method gives accurate energy deposit in a medium with additional information such as secondary and backscattered electron as well as their paths. A Tungsten coated layer is divided by small rectangular cell which accumulate energy loss of primary electron beam. The cells and their accumulated energy datum are used for the input of finite element analysis. The Maximum temperature rising and temperature distribution were analyzed by transient heat analysis. Some temperature parameters such as target size and coating thickness were varied to investigate temperature sensitivity. Temperatures were compared each other to find primary variable that affect temperature rising on the x-ray target. The results will be helpful in development highresolution x-ray tube and related industries.

The Relationship of Overdensity to Overexposure Each Film/screen Systems in Chest Radiography (흉부 X선사진 농도로부터 표면선량을 산출하는 방법)

  • Kim, Jung-Min;Joon, Huo;Hayashi, Taro;Ishida, Yuji;Sakurai, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.22 no.1
    • /
    • pp.13-20
    • /
    • 1999
  • This study is to calculate the exposed radiation dose using Bit method, NDD calculation method and monogram method without dosimeter. In addition, we can calculate the radiation dose from x-ray film density as a film badge. The authors examined the entrance skin dose from $2{\sim}3$ intercostal chest x-ray film density. We also studied the relationship between film density and equivalent dose in the each screen film system under the different radiation quality and the poor geometry condition of grid ratio. As results, we established the deductive method to define the entrance skindose from chest x-ray film density. The error range was found in the range $-13%{\sim}+l7%$ for between deductive entrance skindose and the $2{\sim}3$ intercostal chest x-ray film density to actual detective radiation dose with dosimeter.

  • PDF

Image Recognition and Its Application to Radiograph (화상인식과 X선 영상에의 응용에 관한 연구)

  • Song, Chae-Uk;Yea, Byeong-Deok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.4
    • /
    • pp.829-840
    • /
    • 2001
  • In this study, we propose a method for quantifying the degree of advance of pulmonary emphysema by using chest X-ray images. With this method, we devise two schemes for this purpose. One is for detecting blood vessels by using a deformable model with the tree-like structure and using an evaluation function specialized by knowledge about blood vessels appeared in chest X-ray images, and the other is for quantifying the degree of advance by using several features, which were extracted from blood vessels, and the equation of quantitative evaluation. In order to evaluate the performance, we applied the proposed method to 189 ROIs(Regions of Interest) of ten chest X-ray images and compared the values by the proposed method with those by a medical doctor.

  • PDF

Calculations of ISO Narrow and ANSI X-Ray Spectra, Their Average Energies and Conversion Coefficients (ISO Narrow Series및 ANSI의 X선 스펙트럼, 평균에너지 및 선량환산인자의 이론적 계산)

  • Kim, Jang-Lyul;Kim, Bong-Whan;Chang, Si-Young;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.129-136
    • /
    • 1995
  • In spite of the prescriptions on the reference X-ray fields given by the International Organization of Strandard(ISO) and American National Standard Institute(ANSI), the measurement of X-ray spectrum is not only time consuming but very difficult, paticularly when significant corrections have to be applied to the measured pulse-height distributions of the observed spectra. This paper describes the calculation method of ISO Narrow Series and ANSI X-ray filtered radiations by theoretical model which is modified framer's theory by target attenuation and backscatter correction. The X-ray spectra, average energies and conversion coefficients are calculated and compared with those obtained using the spectra prescribed by ISO and AMSI to assure good agreement.

  • PDF

Determination of Air-dry Density of Wood with Polychromatic X-ray and Digital Detector

  • Kim, Chul-Ki;Kim, Kwang-Mo;Lee, Sang-Joon;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.6
    • /
    • pp.836-845
    • /
    • 2017
  • Gravimetric method is usually used to evaluate air-dry density, which is governing physical or mechanical properties of wood. Although it had high evaluation accuracy, the method is time consuming process. Thus, this study was conducted to estimate air-dry density of wood with high accuracy by using polychromatic X-ray and digital detector as alternative of gravimetric method. To quantify polychromatic X-ray projection for evaluating air-dry density, Lambert-Beer's law with the integral value of probability function was used. The integral value was used as weighting factor in the law, and it was determined by conducting simple test at various penetration depths and tube voltage. Mass attenuation coefficient (MAC) of wood also calculated by investigating polychromatic X-ray projection according to species, penetration depth and tube voltage. The species had not an effect on change of MAC. Finally, an air-dry density of wood was estimated by applying the integral value, MAC and Lambert-Beer's law to polychromatic X-ray projection. As an example, the relation of the integral value (${\alpha}$) according to penetration depth (t, cm) at tube voltage of 35 kV was ${\alpha}=-0.00091t{\times}0.0184$ while the regression of the MAC (${\mu}$, $cm^2/g$) was ${\mu}=0.5414{\exp}(-0.0734t)$. When calculation of root mean squared error (RMSE) was performed to check the estimation accuracy, RMSE at 35, 45 and 55 kV was 0.010, 0.013 and $0.009g/cm^3$, respectively. However, partial RMSE in relation to air-dry density was varied according to tube voltage. The partial RMSE below air-dry density of $0.41g/cm^3$ was $0.008g/cm^3$ when tube voltage of 35 kV was used. Meanwhile, the partial RMSE above air-dry density of $0.41g/cm^3$ decreased as tube voltage increased. It was conclude that the accuracy of estimation with polychromatic X-ray and digital detector was quite high if the integral value and MAC of wood were determined precisely or a condition of examination was chosen properly. It was seemed that the estimation of air-dry density by using polychromatic X-ray system can supplant the gravimetric method.