• 제목/요약/키워드: X-ray inspection

검색결과 214건 처리시간 0.023초

조선강재의 최적 용접조건에 관한 연구 (Study on Optimal Welding Condition for Shipbuilding Steel Materials)

  • 김옥환
    • 한국기계가공학회지
    • /
    • 제10권6호
    • /
    • pp.128-133
    • /
    • 2011
  • In this study, the steel material for shipbuilding(LR-A class) was used, and FCAW was taken advantage of 3G attitude and they are welded by different welding ways. As a result of analyzing wave with welding monitoring system, the stable values are obtained which are the first floor(electronic current 164~182 A, voltage 24 V), the second floor(electronic current 174~190 A, voltage 22~25 V), the third floor(electronic current 158~188 A, voltage 22~25 V), and fourth floor(electronic current 172~184 A, voltage 22~25 V), at this time, the stable wave standard deviation and changing coefficient could be obtained. When the welding testing through nondestructive inspection was analyzed know defect of welding, there was no defect of welding in A, D, E, but some porosities in B, and slag conclusion near the surface in C, because the length of arc was not accurate, and the electronic current and voltage was not stable. After observing the change of heat affect zone through micro testing, each organization of floor formed as Grain Refinement, so welding part was fine, the distance of heat affect zone is getting wider up to change the values of the electronic current and voltage. As a result of degree of hardness testing, the hardness orders were the heat affect zone(HAZ), Welding Zone(WZ), and Base Metal(BM). When the distribution of degree of hardness is observed. B is the highest degree of hardness The reason why heat effect zone is higher than welding zone and base metal, welding zone is boiled over melting point($1539^{\circ}C$) and it starts to melt after the result of analysis through metal microscope, so we can know that delicate tissue is created at the welding zone. Therefore, in order to get the optimal conditions of the welding, the proper current of the welding and voltage is needed. Furthermore the precise work of welding is required.

Radiography with Low Energy Protons Generated from Ultraintense Laser-plasma Interactions

  • Choi, Chang-Il;Lee, Dong-Hoon;Kang, Byoung-Hwi;Kim, Yong-Kyun;Choi, Il-Woo;Sung, Jae-Hee;Kim, Chul-Min;Kim, I-Jong;Yu, Tae-Jun;Lee, Seong-Ku;Pae, Ki-Hong;Hafz, Nasr;Jeong, Tae-Moon;Ko, Do-Kyeong;Lee, Jong-Min
    • Journal of the Optical Society of Korea
    • /
    • 제13권1호
    • /
    • pp.28-32
    • /
    • 2009
  • In order to obtain high quality images of thin objects, we performed an experiment of proton radiography by using low energy protons generated from the interaction of an ultrashort ultraintense laser with solid targets. The protons were produced from a thin polyimide target irradiated by the laser pulse, and their maximum energy was estimated at up to 1.8 MeV. A CR-39 nuclear track detector was used as a proton radiography screen. The proton images were obtained by using an optical microscope and the spatial resolution was evaluated by a Modulation Transfer Function (MTF). We have achieved about $10\;{\mu}m$ spatial resolution of images. The obtained spatial resolution shows about $4{\sim}5$ times better value than the conventional X-ray radiography for inspection or non-destructive test (NDT) purpose.

3 wt% NaCl 수용액에서 알루미늄과 스테인리스강의 부식에 따른 광 반사 거동 (Corrosion and Photo-Reflection Behavior of Aluminum and Stainless Steel During Immersion Test in Salt Solution)

  • 조수연;나현규;조혜리;문종주;안태정;장희진
    • Corrosion Science and Technology
    • /
    • 제19권3호
    • /
    • pp.109-114
    • /
    • 2020
  • The photo-reflectance of aluminum and AISI 304 stainless steel during cyclic immersion test in 3 wt% NaCl solution was examined in this study. Overall, corrosion was not recognized by a visual inspection or weight measurement up to 310 h. When evaluated, it was noted that the roughness of the specimens did not change significantly. However, localized corrosion, which is located at the vicinity of intermetallic precipitation of aluminum or at the grain boundary of stainless steel, was confirmed by the use of an optical microscope and scanning electron microscopy after tens of hours of utilizing the corrosion test. In this respect, an increase of the peak intensity for metallic Al after 90 h of test, and for metallic Fe after 153 h was detected from the X-ray photoelectron spectra. In this context, it was shown that from the photo-reflectance spectra, the reflection of the visible light from the tested samples was changed noticeably over the test duration. As a result, the intensity of reflected light was decreased up to 90 h ~ 153 h, and thereafter was shown to increase higher than the initial intensity before the corrosion test.

The Survey about the Degree of Damage of Radiation-Protective Shields in Operation Room

  • Ryu, Jae Sung;Baek, Seung Woo;Jung, Cheol Hee;Cho, Suk Ju;Jung, Eu Gene;Kim, Hae Kyoung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • 제26권2호
    • /
    • pp.142-147
    • /
    • 2013
  • Background: Medical doctors who perform C-arm fluoroscopy-guided procedures are exposed to X-ray radiation. Therefore, radiation-protective shields are recommended to protect these doctors from radiation. For the past several years, these protective shields have sometimes been used without regular inspection. The aim of this study was to investigate the degree of damage to radiation-protective shields in the operating room. Methods: This study investigated 98 radiation-protective shields in the operation rooms of Konkuk University Medical Center and Jeju National University Hospital. We examined whether these shields were damaged or not with the unaided eye and by fluoroscopy. Results: There were seventy-one aprons and twenty-seven thyroid protectors in the two university hospitals. Fourteen aprons (19.7%) were damaged, whereas no thyroid protectors (0%) were. Of the twenty-six aprons, which have been used since 2005, eleven (42.3%) were damaged. Of the ten aprons, which have been used since 2008, none (0%) was damaged. Of the twenty-three aprons that have been used since 2009, two (8.7%) of them were damaged. Of the eight aprons used since 2010, one (12.3%) was damaged. Of the four aprons used since 2011, none (0%) of them were damaged. The most common site of damage to the radiation-protective shields was at the waist of the aprons (51%). Conclusions: As a result, aprons that have been used for a long period of time can have a higher risk of damage. Radiation-protective shields should be inspected regularly and exchanged for new products for the safety of medical workers.

재생 냉각용 연소기의 최적 브레이징 조건 (Optimized Brazing Conditions of Regenerative Cooling Thrust Chambers)

  • 남대근;홍석호;한규석
    • 한국항공우주학회지
    • /
    • 제31권7호
    • /
    • pp.112-117
    • /
    • 2003
  • 본 연구에서는 재생 냉각용 연소기에 적용되고 있는 동합금과 2상 스테인리스강의 최적 브레이징 조건을 구하였다. 모재는 C18200 동합금과 S31803 2상 스테인레스강을, 삽입금속으로 두께가 각각 50${\mu}m$, 80${\mu}m$인 AMS4764를 사용하였다. 브레이징한 시제에 대하여 X선 검사, 강도/기밀 및 파괴시험, 파단면 관찰을 한 결과 두께 50${\mu}m$인 삽입금속을 사용한 경우 강도특성과 접합면이 양호함을 확인하였다. 반면 두께 80${\mu}m$인 삽입금속을 사용한 경우는 강도특성은 양호하였으나 냉각유로의 막힘 현상과 유로 확대를 확인하였다.

Solderable 이방성 도전성 접착제를 이용한 마이크로 접합 프로세스 (Micro Joining Process Using Solderable Anisotropic Conductive Adhesive)

  • 임병승;전성호;송용;김연희;김주헌;김종민
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2009년 추계학술발표대회
    • /
    • pp.73-73
    • /
    • 2009
  • In this sutdy, a new class ACA(Anisotropic Conductive Adhesive) with low-melting-point alloy(LMPA) and self-organized interconnection method were developed. This developed self-organized interconnection method are achieved by the flow, melting, coalescence and wetting characteristics of the LMPA fillers in ACA. In order to observe self-interconnection characteristic, the QFP($14{\times}14{\times}2.7mm$ size and 1mm lead pitch) was used. Thermal characteristic of the ACA and temperature-dependant viscosity characteristics of the polymer were observed by differential scanning calorimetry(DSC) and torsional parallel rheometer, respectively. A electrical and mechanical characteristics of QFP bonding were measured using multimeter and pull tester, respectively. Wetting and coalescence characteristics of LMPA filler particles and morphology of conduction path were observed by microfocus X-ray inspection systems and cross-sectional optical microscope. As a result, the developed self-organized interconnection method has a good electrical characteristic($2.41m{\Omega}$) and bonding strength(17.19N) by metallurgical interconnection of molten solder particles in ACA.

  • PDF

거푸집 종류에 따른 콘크리트 표면 특성 (Surface Characteristics of Concrete According to Types of Formworks)

  • 박세언;최정일;이봉기;이방연
    • 한국건설순환자원학회논문집
    • /
    • 제9권4호
    • /
    • pp.499-505
    • /
    • 2021
  • 이 연구의 목적은 거푸집 종류별로 콘크리트 표면의 물리/화학적 특성을 실험적으로 조사하는 것이다. 이를 위하여 건설공사에 일반적으로 사용되는 합판 거푸집과 코팅된 합판 거푸집을 준비하였고, 추가로 콘크리트 표면 열화나 거친 표면을 모사하기 위해 사포를 부착한 합판 거푸집을 준비하였다. 콘크리트는 일반 콘크리트를 사용하였다. 콘크리트 표면 특성은 육안관찰, 주사전자현미경 관찰, 성분 이미지 맵핑, 화학성분 분석, 2차원과 3차원 표면 형상 분석, 그리고 제타 전위 측정을 통해 조사하였다. 실험결과 코팅된 거푸집과 접한 콘크리트 표면이 가장 매끄럽고, 사포를 부착한 거푸집과 접한 콘크리트 표면이 가장 거친 것으로 나타났다. 이외에도 거푸집 종류별로 표면 특성에 뚜렷한 차이가 나타났다. 다만 표면 거칠기가 화학 성분이나 제타 전위에 비하여 차이가 크게 나타났다.

A comparative biomechanical study of original and compatible titanium bases: evaluation of screw loosening and 3D-crown displacement following cyclic loading analysis

  • Oziunas, Rimantas;Sakalauskiene, Jurgina;Jegelevicius, Darius;Januzis, Gintaras
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권2호
    • /
    • pp.70-77
    • /
    • 2022
  • PURPOSE. This study evaluated screw loosening and 3D crown displacement after cyclic loading of implant-supported incisor crowns cemented with original titanium bases or with three compatible, nonoriginal components. MATERIALS AND METHODS. A total of 32 dental implants were divided into four groups (n = 8 each): Group 1 used original titanium bases, while Groups 2-4 used compatible components. The reverse torque value (RTV) was evaluated prior to and after cyclic loading (1,200,000 cycles). Samples (prior to and after cyclic loading) were scanned with a microcomputed tomography (micro-CT). Preload and postload files were superimposed by 3D inspection software, and 3D crown displacement analysis was performed using root-mean-square (RMS) values. All datasets were analyzed using one-way ANOVA and Tukey's post hoc analysis. RESULTS. Significant variations were observed in the postload RTV, depending on the titanium base brand (P < .001). The mean postload RTVs were significantly higher in Groups 1 and 2 than in the other study groups. While evaluating 3D crown displacement, the lowest mean RMS value was shown in the original Group 1, with the highest RMS value occurring in Group 4. CONCLUSION. Within the limitations of this in vitro study and under the implemented conditions, it was concluded that the manufacturer brand of the titanium base significantly influenced screw loosening following the fatigue test and influenced 3D crown displacement after cyclic loading.

Efficacy of plasma treatment for surface cleansing and osseointegration of sandblasted and acid-etched titanium implants

  • Gang-Ho Bae;Won-Tak Cho;Jong-Ho Lee;Jung-Bo Huh
    • The Journal of Advanced Prosthodontics
    • /
    • 제16권3호
    • /
    • pp.189-199
    • /
    • 2024
  • PURPOSE. This study was conducted to evaluate the effects of plasma treatment of sandblasted and acid-etched (SLA) titanium implants on surface cleansing and osseointegration in a beagle model. MATERIALS AND METHODS. For morphological analysis and XPS analysis, scanning electron microscope and x-ray photoelectron spectroscopy were used to analyze the surface topography and chemical compositions of implant before and after plasma treatment. For this animal experiment, twelve SLA titanium implants were divided into two groups: a control group (untreated implants) and a plasma group (implants treated with plasma). Each group was randomly located in the mandibular bone of the beagle dog (n = 6). After 8 weeks, the beagle dogs were sacrificed, and volumetric analysis and histometric analysis were performed within the region of interest. RESULTS. In morphological analysis, plasma treatment did not alter the implant surface topography or cause any physical damage. In XPS analysis, the atomic percentage of carbon at the inspection point before the plasma treatment was 34.09%. After the plasma treatment, it was reduced to 18.74%, indicating a 45% reduction in carbon. In volumetric analysis and histometric analysis, the plasma group exhibited relatively higher mean values for new bone volume (NBV), bone to implant contact (BIC), and inter-thread bone density (ITBD) compared to the control group. However, there was no significant difference between the two groups (P > .05). CONCLUSION. Within the limits of this study, plasma treatment effectively eliminated hydrocarbons without changing the implant surface.

태양광 접속함 정션박스 모듈 적용을 위한 Sn-3.0Ag-0.5Cu 및 Sn-1.0Ag-0.7Cu-1.6Bi-0.2In 솔더링의 공정최적화 (Optimization of Soldering Process of Sn-3.0Ag-0.5Cu and Sn-1.0Ag-0.7Cu-1.6Bi-0.2In Alloys for Solar Combiner Junction Box Module)

  • 이병석;오철민;곽현;김태우;윤희복;윤정원
    • 마이크로전자및패키징학회지
    • /
    • 제25권3호
    • /
    • pp.13-19
    • /
    • 2018
  • 본 연구에서는 태양광 접속함 모듈 적용을 위한 유연 솔더(Sn-Pb) 및 무연 솔더(Sn-3.0Ag-0.5Cu 및 Sn-1.0Ag-0.7Cu-1.6Bi-0.2In)의 특성을 비교 평가하였다. 접속함 내에는 전압 및 전류 검출용 모듈, 고내압용 다이오드가 실장된 정류모듈 등 다양한 모듈이 내장되어있다. 본 연구에서는 솔더링특성, 인쇄성, 솔더형상 검사, X-ray를 이용한 솔더 내 void 검사 및 접합강도를 측정하였고, 무연 솔더 합금의 공정최적화는 step 1과 step 2로 구분하여 검토를 실시하였다. Step 1은 유연 솔더와 무연 솔더 페이스트 인쇄 검사 시험을 1차와 2차로 나누어 실험을 진행하였고 printability는 void 함량 및 접합강도의 상관관계로 검토하였다. 전체적으로 유연 솔더의 특성은 무연 솔더에 비하여 상대적으로 우수하였다. Step 2는 리플로우 공정의 최고점 온도 변화에 따른 접합부 특성 변화를 관찰하였다. 리플로우 최고 온도가 증가할수록 접합부 내의 void 함량이 2~4% 정도 감소하였고, 접합강도는 약 0.5 kgf 범위내에서 큰 차이 없이 나타났다. 기판 표면처리종류에 있어서는 ENIG 표면처리가 OSP 및 Pb-free 솔더 표면처리보다 우수한 접합강도를 나타내었다. 1종류의 무연솔더와 OSP 표면처리로 접합된 태양광 접속함 모듈의 500 싸이클 열충격 신뢰성시험 전후에 전기적 특성변화는 0.3% 내의 범위에서 안정적으로 작동함을 확인하였다.