• 제목/요약/키워드: X-ray imaging technique

검색결과 151건 처리시간 0.03초

전기임피던스 단층촬영법을 위한 단순화된 매모그래피 구조의 모델 (A Model of a Simplified Mammography Geometry for Breast Cancer Imaging with EIT)

  • 최명환
    • 산업기술연구
    • /
    • 제26권B호
    • /
    • pp.221-226
    • /
    • 2006
  • Electrical impedance tomography (EIT) is a technique for determining the electrical conductivity and permittivity distribution within the interior of a body from measurements made on its surface. One recent application area of the EIT is the detection of breast cancer by imaging the conductivity and permittivity distribution inside the breast. The present "gold standard" for breast cancer detection is X-ray mammography, and it is desirable that EIT and X-ray mammography use the same geometry. This paper presents a forward model of a simplified mammography geometry for EIT imaging. The mammography geometry is modeled as a rectangular box with electrode arrays on the top and bottom planes. A forward model for the electrical impedance imaging problem is derived for a homogeneous conductivity distribution and Validated by experiment using a phantom tank.

  • PDF

Transport property of a Se:As films for digital x ray imaging

  • 김재형;김재형
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 학술대회 및 기술세미나 논문집 디스플레이 광소자
    • /
    • pp.85-88
    • /
    • 2006
  • The transport properties of amorphous selenium typical of the material used in direct conversion x-ray imaging devices are reported. The effects of As addition on the carrier mobility and recombination lifetime in amorphous selenium (a-Se) films have been studied using the moving photocarrier grating (MPG) technique. We have found an increase in hole drift mobility and recombination lifetime, especially when 0.3% As is added into a-Se film, whereas electron mobility decreases with As addition due to the defect density. The transport properties for As doped a-Se films obtained by using MPG technique have been compared with the drift mobilities of holes and electrons obtained by time of flight (TOF) measurement.

  • PDF

평판형 디지털 엑스레이 가스 검출기의 엑스선 특성 측정기술에 관한 연구 (X-ray properties measurement of Flat panel Digital X-ray gas detector)

  • 윤민석;조성호;오경민;정숙희;남상희;박지군
    • 한국방사선학회논문지
    • /
    • 제3권1호
    • /
    • pp.17-21
    • /
    • 2009
  • 최근 의료진단 분야와 다른 적용분야를 위해 대면적 매트릭스 구조의 엑스선 영상이 활발하게 연구되어 오고 있다. 본 연구에서는, 의료진단을 위한 새로운 평판형 디지털 엑스선 가스 검출기를 제안하고 그에 따른 특성을 검증하고자 한다. 대기압에 반해 가스를 주입하는 어려움 때문에 챔버 형태의 구조로 만들어 질 뿐, 평판형 디지털 엑스선 가스 검출기는 아직 어디에서도 연구된 바 없다. 이에 본 연구에서는 디스플레이 패널 제작 기술을 이용하여 샘플제작을 성공하였다. 실험적인 측정을 위해 만들어진 샘플은 상판에는 유리기판위에 전극, 절연층, 산화마그네슘 보호막을 형성하였으며, 하판에는 엑스선 형광층과 전극을 형성하였다. 누설전류와 엑스선 민감도를 측정하였으며, 전기장에 대한 민감도의 선형성 측정 등의 전기적 특성평가를 실시하였다. 이에 대한 결과로 안정된 누설전류와 엑스선 민감도를 얻었다. 그리고 조사 선량에 따라 좋은 선형성을 보이는 등 넓은 진단 동적영역을 확인할 수 있었다. 이러한 결과로 평판형 엑스선 가스 검출기의 디지털 엑스선 영상 검출기로의 적용 가능성을 확인 할 수 있었다.

  • PDF

moving-photocarrier-grating 기술을 이용한 디지털 X-선 변환물질 a-Se:As의 수송변수 (Transport parameters in a-Se:As films for digital X-ray conversion material using the moving-photocarrier-grating technique)

  • 박창희;남상희;김재형
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제28권4호
    • /
    • pp.267-272
    • /
    • 2005
  • moving photocarrier grating 기술을 이용하여 디지털 X-선 변환물질 a-Se:As 필름에서 As 첨가효과에 관하여 연구하였다. 이 방법은 시료를 조사하기 위하여 주파수를 변화시킨 2개 레이저 빔의 중첩으로 얻어진 움직이는 간섭패턴을 이용한다. 시료의 수송변수는 시료에서 변조 방향으로 유도되는 grating-속도에 의존하는 전류밀도로부터 얻어진다. As 첨가에 따른 a-Se 필름의 전자와 정공 이동도 그리고 재결합 수명을 구하였다. 전자의 이동도는 결함 상태 때문에 As 첨가에 따라 감소하는 반면, 특히 a-Se 필름에 0.3% As 첨가할 때 정공 이동도와 재결합 수명이 증가하였다. MPG 기술로 얻은 As가 첨가된 a-Se 필름의 수송성질을 a-Se:As로 제작한 X-선 디텍터의 X-선 감도와 비교하였다. 실험결과 0.3% As가 첨가된 a-Se으로 제작한 X-선 디텍터가 가장 우수한 X-선 감도를 나타내었다.

  • PDF

공학적방벽재로서 벤토나이트 거동의 X선 단층촬영 기반 비파괴 특성화 현황 (Current Status of X-ray CT Based Non Destructive Characterization of Bentonite as an Engineered Barrier Material)

  • 멜빈;김주연;김광염;이창수;김진섭
    • 터널과지하공간
    • /
    • 제31권6호
    • /
    • pp.400-414
    • /
    • 2021
  • 고준위방사성폐기물 처분장에서 벤토나이트는 공학적방벽재로서 주로 사용되어지는 재료로서 열-수리-역학-화학적 복합적 거동을 겪게 된다. 본 보고에서는 이러한 벤토나이트에 대한 X선 단층촬영 기반의 분석 및 특성화와 관련된 최근 연구 및 기술동향을 고찰하였다. X선 단층촬영 기반 벤토나이트의 평가는 분말형태와 펠렛형태에 대해 적용된 내용을 다루었다. X선 이미징을 통해 마이크로스케일에서 입자의 정보를 추출할 수 있으며 벤토나이트의 불균질성을 야기할 수 있는 펠렛 내부의 균열을 검출할 수 있다. 수화조건하에서 분말과 펠렛이 혼합된 벤토나이트에 대한 X선 분석을 통해 실험과정에서 발생하는 불균질 영역을 특정하고 모니터링이 가능하다. 펠렛으로만 구성된 벤토나이트가 펠렛과 파우더의 혼합으로 이루어진 벤토나이트보다 더 빨리 팽윤되는 특성이 보고되기도 하였다. 벤토나이트의 입자와 블록에 존재하는 작은 균열들이 건조-수화 조건하에서 각각 균열의 닫힘과 열림이 발생하는 것도 확인되었다. 전문 소프트웨어를 이용하여 시공간 단층 이미지로부터 변형률분포를 추출한 경우도 있었다. 최근의 연구들에서는 X선 단층촬영 기술을 이용하여 시간경과에 따른 벤토나이트의 건조밀도, 함수비, 입자의 이동 등을 평가하기도 하였다. 또한, 수화과정에 온도 조건을 고려하여 시간에 따른 재료의 전체 밀도 및 국부적 밀도 변화를 관찰하는 연구도 진행되고 있다.

가속 방사광을 활용한 Fe함유 Al-Si-Cu 주조용 합금의 응고과정 실시간 관찰 및 분석 (Real-time Observation and Analysis of Solidification Sequence of Fe-Rich Al-Si-Cu Casting Alloy by Synchrotron X-ray Radiography)

  • 김봉환;이상환;야스다 히데유키;이상목
    • 한국주조공학회지
    • /
    • 제30권3호
    • /
    • pp.100-110
    • /
    • 2010
  • The solidification sequence and formation of intermetallic phase of Fe-rich Al-Si-Cu alloy were investigated by using real-time imaging of synchrotron X-ray radiation. Effects of cooling rate during uni-directional solidification on the resultant solidification behavior was also studied in a specially constructed vacuum chamber in the SPring-8 facility. The series of radiographic images were complementarily analyzed with conventional analysis of OM and SEM/EDX for phase identification. Detailed solidification sequence and formation mechanisms of various phases were discussed based on real-time image analysis. The growth rates of $\alpha$-AlFeMnSi and ${\beta}-Al_5FeSi$ were measured in order to understand the growth behavior of each phase. It is suggested that real-time imaging technique can be a powerful tool for the precise understanding of solidification behavior of various industrial materials.

X선 위상차 가시화 기법을 이용한 GDI 인젝터 노즐 근방의 분무 간 상호간섭 해석 (Analyzing the Spray-to-spray Interaction of GDI Injector Nozzle in the Near-field Using X-ray Phase-Contrast Imaging)

  • 배규한;문석수
    • 한국분무공학회지
    • /
    • 제25권2호
    • /
    • pp.60-67
    • /
    • 2020
  • Despite its benefit in engine thermal efficiency, gasoline-direct-injection (GDI) engines generate substantial particulate matter (PM) emissions compared to conventional port-fuel-injection (PFI) engines. One of the reasons for this is that the spray collapse caused by the spray-to-spray interaction forms the locally rich fuel-air mixture and increases the fuel wall film. Previous studies have investigated the spray collapse phenomenon through the macroscopic observation of spray behavior using laser optical techniques, but it is somewhat difficult to understand the interaction between sprays that is initiated in the near-nozzle region within 10 mm from the nozzle exit. In this study, the spray structure, droplet size and velocity data were obtained using an X-ray imaging technique from the near-nozzle to the downstream of the spray to investigate the spray-to-spray interaction and discuss the effects of spray collapse on local droplet size and velocity distribution. It was found that as the ambient density increases, the spray collapse was promoted due to the intensified spray-to-spray interaction, thereby increasing the local droplet size and velocity from the near-nozzle region as a result of droplet collision/coalescence.

Metal Area Segmentation in X-ray CT Images Using the RNA (Relevant Neighbor Ar ea) Principle

  • Kim, Youngshin;Kwon, Hyukjoon;Kim, Joongkyu;Yi, Juneho
    • 한국멀티미디어학회논문지
    • /
    • 제15권12호
    • /
    • pp.1442-1448
    • /
    • 2012
  • The problem of Metal Area Segmentation (MAS) in X-ray CT images is a very hard task because of metal artifacts. This research features a practical yet effective method for MAS in X-ray CT images that exploits both projection image and reconstructed image spaces. We employ the Relevant Neighbor Area (RNA) idea [1] originally developed for projection image inpainting in order to create a novel feature in the projection image space that distinctively represents metal and near-metal pixels with opposite signs. In the reconstructed result of the feature image, application of a simple thresholding technique provides accurate segmentation of metal areas due to nice separation of near-metal areas from metal areas in its histogram.

X-ray 영상에서 그리드 아티팩트 개선을 위한 동적 분할 기반 DCT 기법 (A Dynamically Segmented DCT Technique for Grid Artifact Suppression in X-ray Images)

  • 김형규;정중은;이지현;박준혁;서지수;김호준
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제8권4호
    • /
    • pp.171-178
    • /
    • 2019
  • 방사선 진단에서 산란선 보정 그리드의 사용은 굴절되는 신호에 의한 영상의 왜곡을 방지할 수 있는 장점이 있는 반면, X-ray 영상에서 그리드 아티팩트를 발생시키는 부작용을 수반한다. 본 논문에서는 이산코사인변환(DCT: discrete cosine transform)을 사용하여, 그리드 라인을 개선하는 기법을 제안한다. X-ray 영상에서 그리드 라인은 피사체의 형태와 영상의 영역에 따라 서로 다른 특성을 보인다. 이러한 점을 해결하기 위하여 동적 분할 구조를 기반으로 DCT 변환을 적용하고, 개별 분할별로 적합한 필터전달함수를 설계하였다. 세부적으로 주파수 영역 데이터에 대하여 그리드 라인의 대역을 검출하는 알고리즘을 제안하였으며, 필터전달함수로 Kaiser 윈도우와 Butterworth 필터를 조합한 형태의 밴드스톱필터(BSF: band stop filter)를 구현하였다. 또한 블로킹 현상을 개선하기 위하여 다중구조의 영상으로부터 픽셀값을 결정하는 방법론을 제시하였다. 총 140개의 실제 X-ray 영상을 사용한 실험결과로부터 제안된 이론의 타당성을 실험적으로 평가하였다.

1.0Tesla 자기공명 영상장치에서의 혈관조영기법에 관한 연구 (MR Angiography at 1.0Tesla MR Unit)

  • 이윤;류택현;오창현;안창범;이흥규;김종효
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.528-532
    • /
    • 1997
  • X-Ray Angiography has been gold standard or imaging of blood flow. However, patients have to take many risks such as catheterization procedure, iodine contrast agent and ionizing X-rays. MR Angiography has been suggested as a substitute for its non-hazard to patient. But the resolution and contrast was inferior to that of X-ray Angiography. Recently the resolution and the contrast have been much improved due to the development of fast imaging technique.

  • PDF