• Title/Summary/Keyword: X-ray generation

Search Result 273, Processing Time 0.033 seconds

BREEDING EXPERIMENT ON MUTATION INDUCTION BY IRRADIATION (2) Effects of X-ray and Thermal Neutron Irradiation on Dry Seeds of Chinese Cabbage and Radish.

  • Kim, Dawng Woo;Kim, Yang Choon;Cho, Mi Kyung
    • Journal of Plant Biology
    • /
    • v.5 no.1
    • /
    • pp.1-6
    • /
    • 1962
  • 1) Germination rate was rather irregular than decreasing as increasing dose of radiation and there were no differences between Kyong-Sam and Chuong-Bang of Chinese cabbage. 2) In R1 generation, abnormal leaves from seedling of irradiated seeds were observed. These were more apparent in X-ray irradiation than in thermal neutron. 3) Seedling height was inhibited with increasing dose of X-ray and thermal neutrons. Growth inhibition was more remarkable in X-ray than in thermal neutron. Kyong-Sam demonstrated more sensitivity than Chyong-Bang in both X-ray and thermal neutron. 4) Seedling height produced from seeds subjected to thermal neutrons showed small variation around its mean value, while in X-irradiation there was a greater deviaton from the mean value. 5) Fertility was decreased as increasing with dose, while the frequency of abortive pollen was increased. There were variability of the fertility and frequency of abortive pollen among plants or branches of a plant. 6) The mutants were obtained more in thermal neutron irradiation than in X-ray. The types of mutations obtained in Chinese radish of R2 generation were abnormal leaf, densely glowing leaf, degeneration in growing point and dwarf. The maximum frequency of phenotypic mutations was abnormal leaf mutation.

  • PDF

Simmyung Laser System and Study on the X-ray Generation (신명 레이저와 X-선 발생 연구)

  • Kong, Hong-Jin;Han, Ki-Gwan;Kim, Nam-Seong;Kim, Hyun-Soo;Um, Ki-Young;Park, Jong-Rak;Lee, Jae-Youg;Shin, Yun-Sup;Han, Ki-Ho
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1995.06a
    • /
    • pp.185-189
    • /
    • 1995
  • A high-power Nb:glass laser system(Simmyung I) has been contructed and tested. In this system, we used a Nb:YLF laser as a master oscillator, a 4-pass amplifier for pre-amplification, 5 stages of rod amplifiers, and spatial filtering and image reaying usits. The system has demonstrated in excess of 80J(2TW) with 40 psec(FWHM) pulse duration. Output energy, gain and spatial were measured at each amplification stage. With this laser system a preliminary X-ray generation experiment was performed. Pinhole images, X-ray diode signals and X-ray speriment were obtained for the irradiated target of copper. Detailed descriptions of the system performance and the X-tay generation experiment are presented.

  • PDF

Generation of soft X-ray using laser-induced plasma (레이저 플라즈마를 이용한 soft X-선 발생)

  • Kim, G.H.;Seo, G.S.;Lee, H.S.;Rim, G.H.;Jin, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2095-2097
    • /
    • 2000
  • Applications of soft X-ray which corresponds to the wavelength of the order of 1 nm and to the photon energy of the order of 1 key respectively, requires intense sources. Only synchrotron sources were available recently. The development of a new laboratory-sized source of soft X-ray radiation is required for wide applications. This paper introduces the generation of soft X-ray using laser-induced plasma.

  • PDF

Efficient keV X-ray Generation from Irradiation of in-situ Produced Silver Clusters by Ti:sapphire Laser Pulses

  • Chakravarty, U.;Naik, P.A.;Kumbhare, S.R.;Gupta, P.D.
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.80-85
    • /
    • 2009
  • An experimental study of energy absorption and x-ray emission from ultrashort laser pulse irradiation of in-situ produced solid clusters has been performed. Silver clusters produced by a 30 mJ, 300 ps laser pulse were irradiated up to an intensity of $3{\times}10^{17}\;W/cm^2$ by a 70 mJ, 45 fs compressed laser pulse from the same Ti:sapphire laser. Absorption of the laser light exceeding 70% was observed, resulting in an x-ray yield (>1 keV) of ${\sim}60{\mu}J$ pulse. This may constitute a much simpler means of intense x-ray generation using ultrashort laser pulses as compared to the irradiation of structured / pre-deposited cluster targets, and it offers higher x-ray conversion efficiency than that from gas clusters and planar solid targets.

Determination of Tungsten Target Parameters for Transmission X-ray Tube: A Simulation Study Using Geant4

  • Nasseri, Mohammad M.
    • Nuclear Engineering and Technology
    • /
    • v.48 no.3
    • /
    • pp.795-798
    • /
    • 2016
  • Transmission X-ray tubes based on carbon nanotube have attracted significant attention recently. In most of these tubes, tungsten is used as the target material. In this article, the well-known simulator Geant4 was used to obtain some of the tungsten target parameters. The optimal thickness for maximum production of usable X-rays when the target is exposed to electron beams of different energies was obtained. The linear variation of optimal thickness of the target for different electron energies was also obtained. The data obtained in this study can be used to design X-ray tubes. A beryllium window was considered for the X-ray tube. The X-ray energy spectra at the moment of production and after passing through the target and window for different electron energies in the 30-110 keV range were also obtained. The results obtained show that with a specific thickness, the target material itself can act as filter, which enables generation of X-rays with a limited energy.

CUDA-based Fast DRR Generation for Analysis of Medical Images (의료영상 분석을 위한 CUDA 기반의 고속 DRR 생성 기법)

  • Yang, Sang-Wook;Choi, Young;Koo, Seung-Bum
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.4
    • /
    • pp.285-291
    • /
    • 2011
  • A pose estimation process from medical images is calculating locations and orientations of objects obtained from Computed Tomography (CT) volume data utilizing X-ray images from two directions. In this process, digitally reconstructed radiograph (DRR) images of spatially transformed objects are generated and compared to X-ray images repeatedly until reasonable transformation matrices of the objects are found. The DRR generation and image comparison take majority of the total time for this pose estimation. In this paper, a fast DRR generation technique based on GPU parallel computing is introduced. A volume ray-casting algorithm is explained with brief vector operations and a parallelization technique of the algorithm using Compute Unified Device Architecture (CUDA) is discussed. This paper also presents the implementation results and time measurements comparing to those from pure-CPU implementation and open source toolkit.

4th Generation Light Source: X-ray Free Electron Laser (4세대 방사광: 엑스선 자유전자레이저)

  • Han, Jang-Hui
    • Vacuum Magazine
    • /
    • v.3 no.4
    • /
    • pp.4-7
    • /
    • 2016
  • An X-ray Free Electron laser facility (PAL-XFEL) has been built in Pohang Accelerator Laboratory to provide X-ray FEL radiations for photon users. The machine consists of a 10 GeV normalconducting S-band linear accelerator and two undulator beamlines. The hard and soft X-ray beamlines will provide FEL radiations with wavelengths of 0.6 to 0.1 nm and 4.5 to 1 nm, respectively. Beam commissioning of PAL-XFEL is ongoing and user service will start in 2017. In this report, the PAL-XFEL layout and the working principle are discussed.

Exploring Fine Structures of Photoactive Yellow Protein in Solution Using Wide-Angle X-ray Scattering

  • Kim, Tae-Kyu;Zuo, Xiaobing;Tiede, David M.;Ihee, Hyot-Cherl
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.11
    • /
    • pp.1676-1680
    • /
    • 2004
  • We demonstrate that wide-angle X-ray scattering pattern from photoactive yellow protein (PYP) in solution using a high flux third generation synchrotron X-ray source reflects not only the overall structure, but also fine structures of the protein. X-ray scattering data from PYP in solution have been collected in q ranges from 0.02 ${\AA}^{-1}$ to 2.8 ${\AA}^{-1}$. These data are sensitive to the protein structure and consistent with the calculation based on known crystallographic atomic coordinates. Theoretical scattering patterns were also calculated for the intermediates during the photocycle of PYP to estimate the feasibility of time-resolved wide-angle X-ray scattering experiments on such proteins. These results demonstrate the possibility of using the wide-angle solution X-ray scattering as a quantitative monitor of photo-induced structural changes in PYP.

Determination of Thin Film Thickness by EDS Analysis and its Modeling (EDS 분석과 모델링에 의한 박막두께 측정 방법에 관한 연구)

  • Yun, Jae-Jin;Lee, Won-Jong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.8
    • /
    • pp.647-653
    • /
    • 2011
  • In this study, a method to measure the thickness of thin film by EDS (energy dispersive spectroscopy) is suggested. We have developed a model which calculates the thickness of thin film from the characteristic x-ray intensity ratio of the elements in thin film and substrate by considering incident electron beam energy, x-ray generation curve, backscattering and absorption of x-ray, take-off angle of x-ray and tilt angle of the sample. We obtained the relation curve between the film thickness measured experimentally and the x-ray intensity ratio of elements. The film thicknesses calculated from the model agrees quite well with those measured experimentally. Therefore, the thin film thickness can be measured rapidly and accurately by using the model developed in this study and the x-ray intensity ratio obtained in EDS analysis.

Doses of Electron Beam and X-ray Irradiation for Inhibition of Development and Reproduction in Four Insect Pests (4종 해충의 발육과 생식에 대한 전자빔과 X-ray의 억제선량)

  • Yun, Seung-Hwan;Kim, Minjun;Kim, Hyunah;Lee, Seon-Woo;Yoo, Dae Hyun;Kim, Hyun Kyung;Koo, Hyun-Na;Kim, Gil-Hah
    • Korean journal of applied entomology
    • /
    • v.53 no.4
    • /
    • pp.391-398
    • /
    • 2014
  • This study investigated inhibitory doses of electron beam and X-ray irradiation by comparing their effects on the development and reproduction of four insect pests (Myzus persicae, Tetranychus urticae, Liriomyza trifolii, and Frankliniella intonsa). When M. persicae nymphs were irradiated with 100 Gy of electron beam and 30 Gy of X-ray beam, offspring production by adults that developed from the treated nymphs was completely inhibited. When M. persicae adults were irradiated with 200 Gy of electron beam and 50 Gy of X-ray beam, emergence of the $F_1$ generation was inhibited. However, these two ionizing radiations did not affect adult longevity. When T. urticae eggs were irradiated with 150 Gy of electron beam and 50 Gy of X-ray beam, egg hatching was completely inhibited. When L. trifolii pupae were irradiated, the emergence rate decreased with increasing doses of X-ray irradiation. After F. intonsa adults were irradiated with 250 Gy of electron beam and 200 Gy of X-ray beam, egg hatching of the $F_1$ generation was completely suppressed.