• 제목/요약/키워드: X-ray fluorescence spectrometry

검색결과 56건 처리시간 0.025초

Fundamental Parameter 법에 의한 만장굴용암 쌍자석주의 형광X선분포

  • 택훈;고문옥;김경식
    • 동굴
    • /
    • 제19권20호
    • /
    • pp.29-62
    • /
    • 1989
  • Cheju Island, which was formed by volcanic activity, is an oval in its shape with the major axis 80km and the minor axis of 40km. The island holds in its heart Mt. Hanala rising 1,950m above the sea. Petrological study of this volcanic island has been made actively by Sang-Man Lee, Chong-Kwang Won and Moon-Won Li. The chronological measurements of the island by Chong-Kwan Won and Moon-Won Lee showed that it is composed of Sanbangsan trachytes and Backlokdam trachytes(25,000 year ago). These reports are based on the chemical analysis and the rediometric chronological measurements on the ground. However, there has been no reports about the inside of caves. We made an (composition) analysis of the inside of Manjang Cave by the fundamental parameter method in X-ray fluorescence spectrometry. The fundamental parameter method in X-ray fluorescence spectrometry is nondestructive analysis. and it enables us to make the values processed by a computer. The results obtained by this methods are as follows: SiO$_2$(49%), $Al_2$O$_3$(17%), Fe$_2$O$_3$(13%), CaO(8.1%), MgO(5.5%), Na2O(3.6%), TiO$_2$(2.1%), $K_2$O(0.86%), P$_2$O$_{5}$(0.28%), and MnO(0.20%) respectively. The data obtained by the fundamental parameter method in X-ray fluorescene was compared with the data provided by Chong-Kwan Won and Moon-Won Lee. Our measurement was made by K-Ar-method in cooperation with T. ITAYA. The samples are of 30,000-420,000 years ago. The composition of the values of our underground analysis with the existing values obtained by the analyses on the ground produced new data about Cehju volcanic island.d.

  • PDF

용액법을 이용한 황화광석의 X-선 형광분석에 관한 연구 (제2보). 철, 구리 및 코발트의 분석 (Studies on X-Ray Fluorescence Analysis of Sulfide Ores by Solution Technique (II). Analysis of Iron, Copper and Cobalt)

  • 김영상;박기채
    • 대한화학회지
    • /
    • 제26권5호
    • /
    • pp.320-325
    • /
    • 1982
  • 황을 분석하기 위하여 준비한 용액을 이용하여 황화광석중 철, 구리, 코발트를 X-선 형광법으로 정량하였다. 시료를 $Br_2$$HNO_3$의 혼합용액으로 녹인 다음 HF로 처리하여 주성분인 $SiO_2$를 제거한 다음 용액으로 만들었다. 분석결과는 철함량이 20 ~ 50%에서 ${\pm}$1.5%, 구리 함량이 10 ~ 15%에서 ${\pm}$1.0%, 코발트함량이 1 ~ 5% 범위에서 ${\pm}$0.4% 이내로 다른 습식분석법의 data와 일치하고 있으며 재현성에 있어서도 좋은 결과를 얻었다.

  • PDF

매트릭스 보정법을 이용한 규산질 광물 중 화학성분의 X-선 형광분광법 분석 (The Simultaneous Determination of Chemical Ingredients in Silica Minerals by X-ray Fluorescence Spectrometry using Matrix Correction Method)

  • 김영만;최범석;이경미;김선태;이종욱
    • 대한화학회지
    • /
    • 제34권1호
    • /
    • pp.63-68
    • /
    • 1990
  • 규산질 광물 중 화학성분 원소인 $SiO_2,\;Al_2O_3,\;MgO,\;Fe_2O_3,\;CaO$$TiO_2$를 매트릭스 보정법을 이용한 X-선 형광분광법으로 분석하였다. 순수한 금속산화물을 혼합하여 만든 합성표준시료와 분석시료를 $Li_2B_4O_7$로 16배 희석, 용융하여 glass bead로 만들고 Lucas-Tooth와 Pyne 보정식을 사용한 실험계수법으로 성분간의 매트릭스 효과를 보정하였다. 각각 다른 세트의 매트릭스 계수를 사용하여 분석한 결과를 비교적 잘 일치하였으며 표준시료의 수가 많은 세트를 사용할 때 좋은 분석결과를 얻었다. 또한 NIST의 표준시료를 사용하여 이 방법에 의한 정확도를 검토하였다.

  • PDF

근적외선분광분석기 및 에너지 분산형 X선 형광분석기를 이용한 청국장 원산지 판별 (Identification of the geographical origin of cheonggukjang by using fourier transform near-infrared spectroscopy and energy dispersive X-ray fluorescence spectrometry)

  • 강동진;문지영;이동길;이성훈
    • 한국식품과학회지
    • /
    • 제48권5호
    • /
    • pp.418-423
    • /
    • 2016
  • 근적외선분광분석기와 에너지 분산형 X선 형광분석기를 이용한 분석방법을 개발하여 각각 97.5, 98.0%의 높은 정확도의 판별식을 확립하였고, 시중 유통 시료를 분석하여 검증한 결과 각각 96.3, 95.0%의 판별 정확도를 확인하였다. 이상의 연구 결과를 통하여 근적외선분광분석기와 에너지 분산형 X선 형광분석기를 이용하여 청국장 원산지 판별이 가능함을 확인하였고 이는 유기성분 함량에 따른 근적외선 흡광도와 무기성분 함량에 따른 X선 형광에너지 강도가 국내산과 수입산 간에 차이가 있기 때문으로 사료된다.

용액법을 이용한 황화광석의 X-선 형광분석에 관한 연구 (제1보). 황의 분석 (Studies on X-Ray Fluorescence Analysis of Sulfide Ores by Solution Technique (I). Analysis of Sulfur)

  • 김영상;박기채
    • 대한화학회지
    • /
    • 제26권4호
    • /
    • pp.229-234
    • /
    • 1982
  • 용액법을 이용하여 황화광석중 황을 X-선 형광분광법에 의하여 간접적으로 정량하였다. 시료를 B$r_2$와 HN$O_3$의 혼합용액으로 녹여서 황을 S$O^4_{2-}$상태로 산화시켰고 주성분인 Si$O_2$는 HF로 처리하여 날려 보냈다. 이 용액에 여분의 일정량 B$a^{2+}$용액을 가하여 BaS$O_4$로 침전시키고 거른 다음 거른액과 씻은액중의 Ba의 형광 X-선세기를 측정하여 역계산으로 황을 정량하였다. 무게분석법에 의한 결과와 비교하여 보면 함량 $20{\sim}40%$ 범위에서 ${\pm}1.7%$의 평균차이를 나타낸다. 정광시료의 표준편차는 0.69로서 좋은 재현성을 나타냈다.

  • PDF

희석 파라미터법에 의한 주석슬랙중 Ta$_2O_5,\;Nb_2O_5,\;SnO_2$ 및 ZrO$_2$의 X-선형광분석에 관한 연구 (A Study on X-Ray Fluorescence Analysis of Ta$_2O_5,\;Nb_2O_5,\;SnO_2$ and ZrO$_2$ in Tin-slag Samples)

  • 김영상
    • 대한화학회지
    • /
    • 제29권3호
    • /
    • pp.265-270
    • /
    • 1985
  • 희석 파라미터법을 이용한 X-선 형광분광법으로 주석슬랙중 Ta$_2$O$_5$, Nb$_2$O$_5$, SnO$_2$ 및 ZrO$_2$를 정량하였으며 그들의 분석결과를 표준검정곡선법으로 얻은 결과들과 비교하였다. 주석슬랙 시료와 주석슬랙과 비슷한 조성을 갖는 한개의 표준시료를 적당한 희석제(La$_2$O$_3$)로 1 : 1, 1 : 2, 1 : 3, 1 : 4로 각각 희석하였다. 원시료와 희석된 시료의 X-선 세기를 측정하여 희석 파라미터항이 포함된 계산식을 이용하여 함량을 계산하였다. 그 결과 분석값은 표준검정곡선법에 의한 기준값들과 잘 일치하고 있음을 확인하였다.

  • PDF

Setup and Atomic Calibration of Particle Induced X-ray Emission System

  • 송진호;송재봉;존일리야스;김준곤
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.206.2-206.2
    • /
    • 2014
  • Recently, particle induced X-ray emission (PIXE) analysis system was installed at the 2MV ion acceleration system in Korea institute science and technology (KIST). This installation is for complement to low atomic resolution of heavy atoms at Rutherford backscattering spectrometry (RBS) system. For quantitative analysis, a mass calibration of the PIXE set-up has been done with thin film standards and. The GUPIX software package has been used to process the PIXE spectra and the results are compared with the values from RBS system. Therefore, the instrumental constant H (solid angle and correction factor) is determined relying completely on the GUPIX data base (cross-sections, fluorescence and Coster-Kronig probabilities, stopping powers and attenuation coefficients) for a large set of elements. These H values can be used in future analysis.

  • PDF

토양 및 고체시료 중 불소함량 측정기법 (A Review on the Analytical Techniques for the Determination of Fluorine Contents in Soil and Solid Phase Samples)

  • 안진성;김주애;윤혜온
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제18권1호
    • /
    • pp.112-122
    • /
    • 2013
  • Current status of soil contamination with fluorine and its source were investigated. The basic principles and procedures of various techniques for the analysis of fluorine contents in soil and solid phase samples were summarized in this review. Analysis of fluorine in solid matrices can be achieved by two types of techniques: (i) UV/Vis spectrophotometer or ion selective electrode (ISE) analysis after performing appropriate extraction steps and (ii) direct solid analysis. As the former cases, the standard method of Korean ministry of environment, alkali fusion-ISE method, pyrohydrolysis, oxygen bomb combustion, aqua regia digestion-automatic analysis, and sequential extraction-ISE method were introduced. In addition, direct analysis methods (i.e., X-ray fluorescence spectrometry and proton induced gamma-ray emission spectrometry) and atomic spectrometry combining with the equipment for introducing solid phase sample were also reviewed. Fluorine analysis techniques can be reasonably selected through site-specific information such as matrix condition, contamination level, the amount of samples and the principles of various methods for the analysis of fluorine presented in this review.

ED-XRF (Energy Dispersive X-ray Fluorescence spectrometer)를 이용한 콩 원산지 판별 (Discrimination of geographical origin for soybeans using ED-XRF)

  • 이지혜;강동진;장은희;허설혜;신병곤;한국탁;이성훈
    • 한국식품과학회지
    • /
    • 제52권2호
    • /
    • pp.125-129
    • /
    • 2020
  • 본 연구는 무기성분을 활용하여 국산 콩과 외국산 콩의 원산지 판별법을 개발하기 위해 수행하였다. 2018년도에 수집한 국산 100점, 미국, 중국, 베트남, 태국으로 구성된 외국산 97점에 대하여 ED-XRF를 이용하여 총 26종 무기성분의 농도를 산출하였다. T-test, ANOVA, CDA 분석을 통해 원산지판별에 영향을 주는 주요 변수로 5종(P, Ni, Br, Zn, Mn)의 무기성분을 선발하였다. 원산지 판별식을 설정한 결과 감응도 91.0%, 선택성 95.9%, 효율성 93.4%를 나타냈다. 2019년도에 수집한 국산 30점, 외국산 30점으로 원산지 판별식을 검증한 결과 국산 예측률 93.3%, 외국산 예측률 100.0%를 나타냈다. 복잡한 전처리 없이 ED-XRF와 통계처리를 통해 국산 콩과 외국산 콩을 판별할 수 있는 실용적인 판별 체계를 구축하였으며 부정유통 단속을 위한 과학적인 근거자료로서 활용이 가능할 것으로 판단된다.

실리카광물의 산침출 정제와 불순물 분석법 연구 (Impurity analysis and acid leaching purification of silica minerals)

  • 이길용;윤윤열;조수영;채영배
    • 분석과학
    • /
    • 제20권6호
    • /
    • pp.516-523
    • /
    • 2007
  • 2N급(99 %)의 실리카를 3N급(99.9 %)으로 향상시키기 위해서 널리 이용되고 있는 산 침출법(acid leaching)들의 정제효과와 실리카광물에 존재하는 불순물의 분석법에 대한 연구를 수행하였다. 산 침출법에 이용한 용액은 0.2M-oxalic acid (pH1.5, 2.5), conc-Aqua regia, 2.5 %-HCl/HF, 1 %-$HNO_3/HF$의 다섯 종류이었으며, 각 방법의 불순물 정제특성과 침출시간에 따른 침출효율을 조사하였다. 실리카광물과 침출용액중의 불순물 분석은 중성자방사화분석법(neutron activation analysis; NAA), 유도결합 플라즈마 원자방출 분석법(inductively coupled plasma atomic emission spectrometry; ICP-AES), 원자흡광 분광분석법(atomic absorption spectrometry; AAS), x-선 형광분석법(x-ray fluorescence; XRF), 그리고 습식분석법(wet analysis; WA)의 여섯 가지 방법을 이용하였으며, 불순물의 농도와 종류에 따른 분석법들의 장단점을 조사하였다. 실험에 사용한 실리카광물은 습식 비중선별 및 자력선별과 같은 물리적 정제를 거친 순도 99 %급의 실리카로서 $100-150{\mu}m$ 범위의 입도분포를 가지는 분말들이었다. 실리카중 주요 불순물은 Al, Fe, Na, Ca 및 Ti 이었으며 수백에서 수천 mg/kg의 농도로 존재하고 있었다. 산 침출방법과 불순물의 종류에 따른 정제효과를 비교한 결과 2.5 %-HCl/HF 침출방법이 가장 효과적이었으며 이 방법으로 99.1 % 실리카 분말을 99.8 %까지 순도를 향상시킬 수 있었다. 또한 실리카광물과 침출용액의 불순물의 종류와 함량에 따른 최적의 분석기술을 결정할 수 있었다.