• Title/Summary/Keyword: X-ray field

Search Result 1,737, Processing Time 0.029 seconds

Mineralogical and Physical Properties of Lime Plaster used in Wall Repair in Temple of Bagan, Myanmar (미얀마 바간지역 사원 벽체 보수에 사용되는 석회 플라스터의 광물학적 및 물리적 특성)

  • Ahn, Sunah;Kim, Eunkyung;Nam, Byeongjik;Hlaing, Chaw Su Su;Kang, Soyeong
    • Journal of the Mineralogical Society of Korea
    • /
    • v.31 no.4
    • /
    • pp.267-275
    • /
    • 2018
  • The purposes of this study were to analyze the mineralogical characteristics of slaked lime used for wall repair of traditional buildings in Bagan, Myanmar and to evaluate the physical properties of lime plaster produced by the same method as Bagan region. In the X-ray diffraction and thermal analysis of the Myanmar slaked lime, portlandite ($Ca(OH)_2$) and brucite ($Mg(OH)_2$) were detected as main constituent minerals, and a carbonate rock mainly composed of dolomite ($CaMg(CO_3)_2$) minerals may be used as a raw material to make slaked lime. The field-emission scanning electron microscope analysis showed that the Myanmar slaked lime was composed of irregularly shaped crystals of $0.5{\mu}m$ or larger and a small amount of $0.1{\mu}m$ of plate - like crystals. The size and uniformity of crystals in Myanmar lime is different from that of Korea slaked lime. This may be attributed to the effect of the mineral composition and the lime hydration method of Myanmar, which produces slurry by immersing the burnt lime in excess water for a long period of time. The compressive strength of the lime plaster in Myanmar resulted in a mean value of $1.13N/mm^2$ for the specimens cured for 28 days. The strength of the specimens with Bale juice was $1.03N/mm^2$, respectively. The lime is an air setting material that exhibits strength through long carbonation process. Therefore, it is necessary to evaluate physical properties according to curing period through long-term curing over 28 days in the future.

Study on Development in Professional Work of Radiological Technologists (방사선사 업무의 발전에 관한 조사 연구)

  • Choi, Jong-Hak;Kim, Chang-Kyun;Kim, Won-Chul;Kim, Seung-Chul
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.197-210
    • /
    • 2006
  • This study explored several agenda related to license system, education, professional work of radiological technologists(RTs) and a transition process of law for them to investigate a developmental strategy of RTs as a professional career. The results are as followings : 1. The national license system for RTs was started from 1965, 1965-1972 x-ray technicians(medical assistance), 1973-present(2006) radiotechnologist(medical technologist) since then. 2. The average pass ratio of national license examination(1965-2006) for RTs was 46.6%. The method, subjects and level of the examination should be improved. 3. The education term for RTs has been changed since 1963 ; 1963-1990 two year college, 1991-1999 three year college, 2000-2006 four year and three year college depending on universities and colleges. As of 2006, there are twelve 4-year universities and eighteen 3-year colleges. The total number of new students were 1,956. 4. The new developmental paradigm should be made for technology education of RTs corresponding to the development of medicine and science. 5. The qualification system of clinical specialists in radio-technology field needs to be operated not by the non-governmental body(The Korean Radiological Technologists Association) but by the governmental body. 6. The vertical relationship among RTs, doctors and other medical workers should be rebuilt through the revision of law. Especially, doctors and dentists 'guidance authority' for RTs should be changed to 'request authority'. 7. The service extent of RTs should be extended in medical fields corresponding to professional work of RTs and a revision of the law needed for this situation.

  • PDF

CO2 Sequestration and Utilization of Calcium-extracted Slag Using Air-cooled Blast Furnace Slag and Convert Slag (괴재 및 전로슬래그를 이용한 CO2 저감 및 칼슘 추출 후 슬래그 활용)

  • Yoo, Yeongsuk;Choi, Hongbeom;Bang, Jun-Hwan;Chae, Soochun;Kim, Ji-Whan;Kim, Jin-Man;Lee, Seung-Woo
    • Applied Chemistry for Engineering
    • /
    • v.28 no.1
    • /
    • pp.101-111
    • /
    • 2017
  • Mineral carbonation is a technology in which carbonates are synthesized from minerals including serpentine and olivine, and industrial wastes such as slag and cement, of which all contain calcium or magnesium when reacted with carbon dioxide. This study aims to develop the mineral carbonation technology for commercialization, which can reduce environmental burden and process cost through the reduction of carbon dioxide using steel slag and the slag reuse after calcium extraction. Calcium extraction was conducted using NH4Cl solution for air-cooled slag and convert slag, and ${\geq}98%$ purity calcium carbonate was synthesized by reaction with calcium-extracted solution and carbon dioxide. And we conducted experimentally to minimize the quantity of by-product, the slag residue after calcium extraction, which has occupied large amount of weight ratio (about 80-90%) at the point of mineral carbonation process using slag. The slag residue was used to replace silica sand in the manufacture of cement panel, and physical properties including compressive strength and flexible strength of panel using the slag residue and normal cement panel, respectively, were analyzed. The calcium concentration in extraction solution was analyzed by inductively coupled plasma optical emission spectrometer (ICP-OES). Field-emission scanning electron microscope (FE-SEM) was also used to identify the surface morphology of calcium carbonate, and XRD was used to analyze the crystallinity and the quantitative analysis of calcium carbonate. In addition, the cement panel evaluation was carried out according to KS L ISO 679, and the compressive strength and flexural strength of the panels were measured.

Effective Dose Evaluation using Clinical PET/CT Acquisition Protocols (전신 PET/CT 영상 획득 프로토콜을 이용한 유효선량 평가)

  • Nam, So-Ra;Son, Hye-Kyung;Lee, Sang-Hoon;Lee, Chang-Lae;Cho, Hyo-Min;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.173-178
    • /
    • 2006
  • The purpose of this study was to evaluate the radiation dose for clinical PET/CT protocols in clinical environments using Alderson phantom and TLDs. Radiation doses were evaluated for both Philips GEMINI 16 slice PET/CT system and GE DSTe 16 slice PET/CT system. Specific organ doses with $^{137}Cs$ transmission scan, high quality CT scan and topogram in philips GEMINI PET/CT system were measured. Specific organ doses with CT scan for attenuation map, CT scan for diagnosis and topogram in GE DSTe PET/CT system were also measured. The organs were selected based on ICRP60 recommendation. The TLDs used for measurements were selected for within an accuracy of ${\pm}5%$ and calibrated in 10 MV X-ray radiation field. The effective doses for $^{137}Cs$ transmission scan, high qualify scan, and topogram in Philips GEMINI PET/CT system were $0.14{\pm}0.950,\;29.49{\pm}1.508\;and\;0.72{\pm}0.032mSv$ respectively. The effective doses for CT scan to make attenuation map, CT scan to diagnose and topogram in GE DSTe PET/CT system were $20.06{\pm}1.003,\;24.83{\pm}0.805\;and\;0.27{\pm}0.008mSv$ respectively. We evaluated the total effective dose by adding effective dose for PET Image. The total PET/CT doses for Philips GEMINI PET/CT (Topogram+$^{137}Cs$ transmission scan+PET, Topogram+high qualify CT+PET) and GE DSTe PET/CT (Topogram +CT for attenuation map+ PET, Topogram+diagnostic CT+ PET) are $7.65{\pm}0.951,\;37.00{\pm}1.508,\;27.12{\pm}1.003\;and\;31.89{\pm}0.805mSv$ respectively. Further study may be needed to be peformed to find optimal PET/CT acquisition protocols for reducing the patient exposure with good image qualify.

  • PDF

Corrosion Characteristics by CCPP Control in Simulated Distribution System (CCPP 조절에 따른 모의 상수관로의 부식특성에 관한 연구)

  • Kim, Do-Hwan;Lee, Jae-In;Lee, Ji-Hyung;Han, Dong-Yueb;Kim, Dong-Youn;Hong, Soon-Heon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.12
    • /
    • pp.1249-1256
    • /
    • 2005
  • This study was performed to investigate the efficiency of the corrosion prevention in the simulated distribution system using CCPP(Calcium Carbonate Precipitation Potential) as the anti-corrosive index by adjusting pH, total dissolved solids, alkalinity and calcium hardness in the water treatment pilot process. The materials of the simulated distribution system(SDS) were equiped with same materials of real field water distribution system. CCPP concentrations controlled by $Ca(OH)_2$, $CO_2$ gas and $Na_2CO_3$ in the simulated distribution system and uncontrolled by the chemicals in the general water distribution system were average 0.61 mg/L and -7.77 mg/L. The concentrations of heavy metals like Fe, Zn, Cu ions in effluent water of the simulated distribution system controlled with water quality were decreased rather than the general water distribution system uncontrolled with water quality. In simulated distribution system(SDS), corrosion prevention film formed by CCPP control was observed that scale was come into forming six months later and it was formed into density as time goes on. We were analyzed XRD(X-ray diffraction) for investigating component of crystal compounds and structure for galvanized steel pipe(15 mm). Finding on analysis, scale was compounded to $Zn_4CO_3(OH)_6{\cdot}H_2O$ (Zinc Carbonate Hydroxide Hydrate) after ten months late, and it was compounded on $CaCO_3$(Calcium Carbonate) and $ZnCO_3$(Smithsonite) after nineteen months later.

Analysis of Set-up Errors during CT-scan, Simulation, and Treatment Process in Breast Cancer Patients (유방암 환자의 모의치료, CT 스캔 및 치료 과정에서 발생되는 준비 오차 분석)

  • Lee, Re-Na
    • Radiation Oncology Journal
    • /
    • v.23 no.3
    • /
    • pp.169-175
    • /
    • 2005
  • Purpose: Although computed tomography (CT) simulators are commonly used in radiation therapy department, many Institution still use conventional CT for treatments. In this study the setup errors that occur during simulation, CT scan (diagnostic CT scanner), and treatment were evaluated for the twenty one breast cancer patients. Materials and Methods: Errors were determined by calculating the differences in isocenter location, SSD, CLD, and locations of surgical clips implanted during surgery. The anatomic structures on simulation film and DRR image were compared to determine the movement of isocenter between simulation and CT scan. The isocetner point determined from the radio-opaque wires placed on patient's surface during CT scan was moved to new position if there was anatomic mismatch between the two images Results: In 7/21 patients, anatomic structures on DRR Image were different from the simulation Image thus new isocenter points were placed for treatment planning. The standard deviations of the diagnostic CT setup errors relative to the simulator setup in lateral, longitudinal, and anterior-posterior directions were 2.3, 1.6, and 1.6 mm, respectively. The average variation and standard deviation of SSD from AP field were 1.9 mm and 2.3 mm and from tangential fields were 2.8 mm and 3.7 mm. The variation of the CLD for the 21 patients ranged from 0 to 6 mm between simulation and DRR and 0 to 5 mm between simulation and treatment. The group systematic errors analyzed based on clip locations were 1.7 mm in lateral direction, 2.1 mm in AP direction, and 1.7 mm in SI direction. Conclusion: These results represent that there was no significant differences when SSD, CLD, clips' locations and isocenter locations were considered. Therefore, it is concluded that when a diagnostic CT scanner is used to acquire an image, the set-up variation is acceptable compared to using CT simulator for the treatment of breast cancer. However, the patient has to be positioned with care during CT scan in order to reduce the setup error between simulation and CT scan.

Semi-Longitudinal Study on Growth Development of Children Aged 6 to 16 (한국인 정상아동 6세~16세의 악안면 성장에 관한 준종단적 연구)

  • Jeong, Mi;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.29 no.1 s.72
    • /
    • pp.51-72
    • /
    • 1999
  • In orthodontic field, it is very important to understand the normal growth. Such an understanding can be derived from observation of normal growth in various samples from childhood to adulthood, and this builds a foundation from which growth abnormality or variation can be defined. Thus, a broad data collection of normal children, as well as basic study reviewing such data become necessary. The relationship between the mean values of cephalometric measurements in Growth and Development was studied among the groups(boys and girls) of Korean chidren from the ages 6-years to 16-years. 220 boys 170 girls were chosen as subjects : Cephalometric X-ray were taken for 3 years and hard tissue analysis on McNamara and Ricketts Analysis which was divided into measurements of 5 parts(Cranial base, Cranial base and Maxilla & Mandible, Maxilla and Mandible, Mandible, Dental measurements). The relationship of craniofacial growth was studied. The following conclusions were obtained: 1. There were statistically significant differences in anterior cranial base between the two sexes of 14 and 15-year grouips. 2. In comparison of growth amounts among different age groups, statistically singnificant difference in Posterior facial height exhisted among $10\~11,\;12\~13\;and\;14\~15$ year-old interval groups. This pattern increased with aging. 3. Na perpendicular to A showed earlier growth peak in females(11-12years) than males(12-13years). When horizontal measurements of point A and Pogonion are compared, mandibular growth appeared to be greater. 4. Maximum growth peak of cranial base and mandible was earlier in females (11-12years) than males(13-14 years). 5. Upper central incisor flared out with aging, and there were increases in lower incisor to A-Pg, and lower incisor inclination There was significant difference between the two sexes in 10-year-old group.

  • PDF

Development of Phantom and Comparison Analysis for Performance Characteristics of MOSFET Dosimeter (MOSFET 선량계 특성분석을 위한 팬톰 개발 및 특성 비교)

  • Chung, Jin-Beom;Lee, Jeong-Woo;Kim, Yon-Lae;Lee, Doo-Hyun;Choi, Kyoung-Sik;Kim, Jae-Sung;Kim, In-Ah;Hong, Se-Mie;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.48-54
    • /
    • 2007
  • This study is to develope a phantom for MOSFET (Metal Oxide Semiconductors Field Effect Transistors) dosimetry and compare the dosimetric properties of standard MOSFET and microMOSFET with the phantom. In this study, the developed phantom have two shape: one is the shape of semi-sphere with 10cm diameters and the other one is the flat slab of $30{\times}30cm$with 1 cm thickness. The slab phantom was used for calibration and characterization measurements of reproducibility, linearity and dose rate dependency. The semi-sphere phantom was used for angular and directional dependence on the types of MOSFETs. The measurements were conducted under $10{\times}10cm^2$ fields at 100cm SSD with 6MV photon of Clinac (21EX, Varian, USA). For calibration and reproducibility, five standard MOSFETS and microMOSFETs were repeatedly Irradiated by 200cGy five times. The average calibration factor was a range of $1.09{\pm}0.01{\sim}1.12{\pm}0.02mV/cGy$ for standard MOSFETS and $2.81{\pm}0.03{\sim}2.85{\pm}0.04 mV/cGy$ for microMOSFETs. The response of reproducibility in the two types of MOSFETS was found to be maximum 2% variation. Dose linearity was evaluated In the range of 5 to 600 cGy and showed good linear response with $R^2$ value of 0.997 and 0.999. The dose rate dependence of standard MOSFET and microMOSFET was within 1% for 200 cGy from 100 to 500MU/min. For linearity, reproducibility and calibration factor, two types of MOSFETS showed similar results. On the other hand, the standard MOSFET and microMOSFET were found to be remarkable difference in angular and directional dependence. The measured angular dependence of standard MOSFET and microMOSFET was also found to be the variation of 13%, 10% and standard deviation of ${\pm}4.4%,\;{\pm}2.1%$. The directional dependence was found to be the variation of 5%, 2% and standard deviation of ${\pm}2.1%,\;{\pm}1.5%$. Therefore, dose verification of radiation therapy used multidirectional X-ray beam treatments allows for better the use of microMOSFET which has a reduced angular and directional dependence than that of standard MOSFET.

  • PDF

A Study on the Environment for Lowbirth Weight Infants in Neonatal Intensive Care Unit in the United States (신생아집중간호단위 환경과 저체중출생아의 반응에 대한 연구)

  • Han Kyung Ja
    • Child Health Nursing Research
    • /
    • v.4 no.2
    • /
    • pp.159-176
    • /
    • 1998
  • In effort to conduct comparative study on the caregiving environment of Neonatal Intensive Care Unit(NICU) in both U. S and Korea, this study was been conducted first in the U.S. Purpose : The purpose of this study is to identify the physical environment and direct caregiving practices to lowbirth weight infants in NICU in the US. It also aims to examine the NICU outcome status and behavioral reponses of lowbirth weight infants. Methods : A study design using descriptive and inferential statistics was been conducted through an observational, field method. A sample of 15 preform infants admitted to NICU were recruited for the study. The subjects were those with birth weight between 1,000 gm to 1,500 gm, born at the gestation period of 27 to 33 weeks, and without any chromosomal or other genetic anomalies, major congenital infections, or maternal illness. Thirty minutes observation(three times of ten minutes of continuous observation)of the infant's behavior and physiological status, and an four-hour observation of the physical environment and direct care giving procedures were been conducted on the 3rd and 10th day after birth, and on the day of discharge from the NICU or at 34weeks postconception. The data to be collected were in four areas : the demograghic characteristics of the infants, the physical environment and care giving procedures, the frequency of the infant's designated behavior and physiological response, and NICU outcome variables. A descriptive analysis and Kruskal-Wallis, Pearson r were been applied according to variable characteristics. Results : 1. Mother's mean age was 29.47. The sample consisted of 6 males and 9 females. Mean gestational ages were 29.17 weeks. Mean birth weight was 1236.33g. Mean Apgar scores at one minute were 6.6, and 7.8 at five minutes. 2. The location for the incubator was in the distance from the light, X-ray screens and nursing station, in proximity to side-lamp, telephone and faucet on the third day after birth. The location for the incubator was in the distance from the light and radio on the tenth day and in proximity to nursing station on the day of dischage from the NICU or at 34weeks postconception. 3. Nesting was the most applying aids to the infants. And foot roll, shielding and plastic frame were frequently using by nurses for facilitating well modulated restful posture. 4. There were statistically significant changes in the patterns of physical environment included locating the infant's incubator and bedding, specific aids to self regulation on the 3rd and 10th day after birth, and on the day of discharge from the NICU or at 34weeks postconception. 5. Statistically significant changes were not appeared in the patterns of direct caregiving procedure to the infants included stress inducing or reducing manipulations on the 3rd and 10th day after birth, and on the day of discharge from the NICU or at 34weeks postconception. 6. The stress response of the infants in NICU were significantly reduced as the infants grow older. 7. There were not statistically significant correlation between the physical envronment and the stress responses of the infants in NICU. 8. There were statistically significant correlation between the direct caregiving procedure to the infants and the stress response of the infants in NICU in the second and third observation on the day three. 9. Average weight gain per day from birth to discharge was 38.73g, number of days in the hospital was 42.60, number of days before bottle feeding was 3.6. Postconception age starting bottle feed ing was 31/sup +5/ weeks. Number of days on mechanical ventilator was average 7.64, 11.42 was an average number of days of oxygen need. Conclusion : It, thus, appears that to minimize the sensorymotor stimulation for the low birthweight preterm infant in NICU, manipulation of care giving practices to the babies whatever the stress inducing or reducing procedures, have to be limited in the immediate early stage after birth. And it needed to be reexamine to identify the appropriate and specific physical environment and the patterns of direct caregiving to the low birthweight preform infant as the infants grow older in NICU.

  • PDF

Taxonomic Characteristics of Korean-native Anacardiaceae (한국산(韓國産) 옻나무과(科)의 분류학적(分類學的) 연구(硏究))

  • Kim, Sam Sik;Chung, Jae Min
    • Journal of Korean Society of Forest Science
    • /
    • v.84 no.2
    • /
    • pp.151-165
    • /
    • 1995
  • This study was conducted to establish a systematized taxonomic problems of through the leaf morphological characters and leaf venation patterns, and stomatal cell patterns and cell characteristics of abaxial and adaxial surface of the leaflets by SEM, of 6 native species in Korea and 2 foreign species of the Genus Rhus in the Family Anacardiaceae. The results obtained from this study are summarized as followings: 1. Morphological study measured 32 characters of leaves from herbarium specimen and field-collected samples for each species. The results of cluster analysis based on the Euclidean distance showed that the species could be classified into 3 groups: R. sylvestris. R. typhina, R. succedanea: R. trichocarpa. R. chinensis. R. verniciflua: and R. ambigua. R. radicans subsp. orientale, Analysis of principal components showed 5 groups: The major factors in the first principal component group was length of petiole of the terminal leaflets, that in the second group angle of left side in the terminal leaflet bash, that in the third group area ratio between first and terminal leaflets, that in the forth group angle ratio between right and left side in the terminal leaflet base, and that in the fifth group was angle of main and secondary vein at midrib of terminal leaflet. Cumulative contribution by the first, second and third principal component group was explained with 82.6%, a large percent of all information. 2. The leaf venation pattern investigated using soft X-ray photography revealed clado-and reticulo-camptodromous types according to branching angle of the secondary vein. And three groups by the developing degree of secondary vein were R. trichocarpa, R. ambigua. R. chinensis, R. typhina; R. radicans subsp. onentale, R. succedanea, R. verniciflua: and R. sylvestris. Classification key for the Rhus of Korean-native Anacardiaceae was made by the venation pattern and devevoping degree of the secondary vein. 3. The stomatal cell patterns were greatly classified into paracytic and anomocytic types, specific among species according to stomatal and subsidiary cell patterns, and various differences among the species was determined. Microstructure of the adaxial and abaxial surfaces could be divided into synclinal and anticlinal cell wall patterns, and were specific-species. Stomatal cells of R. chinensis were surrounded with characterized villus-like cells.

  • PDF