• 제목/요약/키워드: X-ray emission

검색결과 1,313건 처리시간 0.033초

IMAGING NON-THERMAL X-RAY EMISSION FROM GALAXY CLUSTERS: RESULTS AND IMPLICATIONS

  • HENRIKSEN MARK;HUDSON DANNY
    • 천문학회지
    • /
    • 제37권5호
    • /
    • pp.299-305
    • /
    • 2004
  • We find evidence of a hard X-ray excess above the thermal emission in two cool clusters (Abell 1750 and IC 1262) and a soft excess in two hot clusters (Abell 754 and Abell 2163). Our modeling shows that the excess components in Abell 1750, IC 1262, and Abell 2163 are best fit by a steep power law indicative of a significant non-thermal component. In the case of Abell 754, the excess emission is thermal, 1 ke V emission. We analyze the dynamical state of each cluster and find evidence of an ongoing or recent merger in all four clusters. In the case of Abell 2163, the detected, steep spectrum, non-thermal X-ray emission is shown to be associated with the weak merger shock seen in the temperature map. However, this shock is not able to produce the flatter spectrum radio halo which we attribute to post-shock turbulence. In Abell 1750 and IC 1262, the shocked gas appears to be spatially correlated with non-thermal emission suggesting cosmic-ray acceleration at the shock front.

LASER-PRODUED PLASMA AS AN X-RAY SOURCE

  • 김효근
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1991년도 제6회 파동 및 레이저 학술발표회 Prodeedings of 6th Conference on Waves and Lasers
    • /
    • pp.64-64
    • /
    • 1991
  • The interaction of high-intensity, focused, nanosecond laser light with matter results in the production of high-temperature plasma, which in turn emits an intense pulse of x rays. The x-ray spectrum consists of strong line components of several keV photon energy and broad continuum. Such an x-ray source provides many advantages over conventional ones for many applications. Pulse nature of the x-ray emission is well-suited for studying transient phenomena and for imaging living biological specimen. Recent experiments have also shown that the laser plasma x ray may be used for x ray lithography. These studies and other applications will be discussed in detail.

  • PDF

Exploring the Diffuse X-ray Emission of Supernova Remnant Kesteven 69 with XMM-Newton

  • Seo, Kyoung-Ae;Hui, Chung Yue
    • Journal of Astronomy and Space Sciences
    • /
    • 제30권2호
    • /
    • pp.87-90
    • /
    • 2013
  • We have investigated the X-ray emission from the shock-heated plasma of the Galactic supernova remnant Kesteven 69 with XMM-Newton. Assuming the plasma is at collisional ionization equilibrium, a plasma temperature and a column absorption are found to be kT ~ 0.62 keV and $N_H{\sim}2.85{\times}10^{22}\;cm^{-2}$ respectively by imaging spectroscopy. Together with the deduced emission measure, we place constraints on its Sedov parameters.

MCV 자기구에서의 선방출 (LINE EMISSION FROM THE MAGNETOSPHERE OF MAGNETIC CATACLYSMIC VARIABLES)

  • 김용기
    • 천문학논총
    • /
    • 제15권spc1호
    • /
    • pp.113-118
    • /
    • 2000
  • A magnetic cataclysmic variable has a rotating magnetic white dwarf which accretes matter from its late type companion. Kim & Beuermann (1995) presented a phenomenological model of the accretion from its surrounding structure e.g., a disk into the magnetosphere of the white dwarf, and presented results for the spin modulated X-ray spectrum and light curves. Using this model, we calculate the optical continuum and line emission which result from reprocessing of X-rays in the accretion stream within the magnetosphere. Penning (1985) suggested the observed spin-modulated radial-velocity variations might result from reprocession of X-rays in the disk. We, however, find the radiation can be originated from the magnetosphere accretion stream. We use the same geometrical model to calculate the optical and the X-ray behaviour. The results from the two wavelength bands are internally consistent. We conclude that this approach will increase the diagnostic accuracies of the results.

  • PDF

경북 지역 의원급의 X선 발생장치 정도관리 실태 (Medical Clinics' quality Management of X-ray Units in Gyeongbuk Area)

  • 박정규
    • 한국콘텐츠학회논문지
    • /
    • 제10권9호
    • /
    • pp.267-275
    • /
    • 2010
  • X선 발생장치의 정도관리는 의료기관의 설립형태에 따라 가장 큰 차이가 있으며, 장치의 보유율은 1차 의료기관에서 가장 많이 보유한 반면 정도관리에 대한 인식과 관리는 소홀하다 할 수 있다. 본 연구에서는 2010년 1월 4일부터 2010년 9월 3일까지 경북 지역을 4개의 권역으로 나누고, 각 시별로 4곳을 임으로 선정하였다. 전체 16곳에 있는 의원급 의료기관 중 10년 이상 된 X선 발생장치를 보유한 8곳과 10년 이하의 X선 발생장치를 보유한 8곳를 그 대상으로 하였으며, 정도관리의 필수 항목 5가지를 시험하였다. 접지 설비 확인시험에서는 10년 이상 된 X선 장치를 보유한 한 곳이 별도의 접지선을 구비하지 않았으며(6.25%), 외장 누설전류시험에서는 모두 적합 하였다. 조사선량 재현성 시험에서는 10년 이상 된 X선 발생장치를 보유한 4곳(25%)과 10년 이하의 X선 발생장치를 보유한 1(6.25%)곳이 부적합 하였다. 관전압의 정확도 시험에서는 10년 이상 된 X선 발생장치를 보유한 5곳(31.25%)과 10년 이하의 X선 장치를 보유한 2곳(12.5%)이 부적합 하였다. 관전류와 관전류량 시험에서는 10년 이상 된 X선 장치를 보유한 3곳(18.75%)과 10년 이하의 X선 장치를 보유한 1곳(6.25%)이 부적합 하였다. 본 연구 결과 10년 이하의 X선 발생장치를 보유한 의원급 의료기관 보다 10년 이상 된 의원급 의료기관의 X선 발생장치의 정도 관리 실태는 심각한 수준 이였다. 검사 결과를 바탕으로 행정적, 기술적인 조치들이 신속하게 이루어져야 할 것이다. 또한 의원급의 사업주나 장치 담당자들의 의식 전환이 필요 하며 그러기 위해서는 오래된 장비이거나 자주 사용하지 않는 장비일수록 정기검사주기를 1~2년 단위로 개정하여야 하고, 정기적인 정도 관리 교육 프로그램을 실시하여야 할 것으로 사료된다.

X-선 천문 분야의 분광관측 연구 (SPECTROSCOPIC STUDIES IN X-RAY ASTRONOMY)

  • 최철성
    • 천문학논총
    • /
    • 제15권spc1호
    • /
    • pp.73-83
    • /
    • 2000
  • X-ray astronomy deals with measurements of the electromagnetic radiation in the energy range of $E\~0.1-100 keV (\lambda\~0.12-120{\AA})$. The wavelength of X-ray is comparable to the size of atoms, so that the photons in the X-ray range are usually produced and absorbed by the atomic processes. Since the launch of the first X-ray astronomy satellite 'Uhuru' in 1970, technological advances in a launch capability and a detection capability make X-ray astronomy one of the most rapidly evolving fields of astronomical research. Particularly, a spectral resolving power $E/{\Delta}E$ has been increased by an order of 2 - 3 (in the energy range of 0.1 - 10 keV) during the past 30years. In this paper, I briefly review a developing process of the resolving power and spectroscopic techniques. Then I describe important emission/absorption lines in X-ray astronomy, as well as diagnostics of gas property with line parameters.

  • PDF

이차전지 양극활물질의 chemical state 측정을 위한 X0ray Induced Electron Emission Spectroscopy (XIEES)의 활용

  • 이재철;송세안;임창빈
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2000년도 제18회 학술발표회 논문개요집
    • /
    • pp.167-167
    • /
    • 2000
  • 전지 재료의 충방전 과정 연구에는 X-선 분말회절(x-ray powder diffraction techniques)과 중성자회절을 많이 사용하였다. 하지만 이러한 분석기술은 long-range order의 구조에 관한 정보를 제공하는데 유용하지만 atomic scale의 구조에 관한 정보를 얻기에는 한계가 있다. Li 전지에서의 전기화학적 반응에서는 cathode 물질에 포함된 전이금속의 산화, 환원 반응에 의한 Li 이온의 intercalation (charge process)과 deintercalation (discharge process) 현상이 일어난다. 이러한 충방전 과정은 알려지지 않은 다양한 형태의 위상 변화를 동반하게 되는데 x-선 이나 중성자를 이용한 powder diffraction techniques 로는 단지 정성적인 결정학적 정보를 얻을 수 있다. 따라서 최근에 원자 단위의 local structure에 관한 정보와 electrochemical state에 관한 정보를 동시에 얻을 수 있는 X-ray Absorption Fine Structure (XAFS) 분석기술을 Li 전지분석에 활용하기 시작하였다. XAFS는 하나의 x-ray 흡수원자에 대해서 주변원자들의 원자구조에 관한 정보와 구성 원소의 electrochemical state에 관한 정보를 얻을 수 있는 분석방법이다. X-ray Induced Electron Emission Spectroscopy (XIEES)는 x-ray에 의해서 방출된 전자를 검출하여 스펙트럼을 얻는 기능을 함축적으로 나타낸 것으로, x-ray를 물질 표면에 조사하여 발생하는 광전자, Auger 전자, 이차전자 등을 전자검출기(Channel Electron Multiplier: CEM)로 검출하는 기능과, 시료를 투과한 x-ray와 시료에서 발생하는 형광 x-ray를 비례계수기로 검출하는 기능을 가지고 있다. 이러한 검출 능력을 바탕으로 EXAFS, XANES, Standing Wave Technique, Elemental Composition Analysis, DXRD, Total Reflection Technique 등을 이용하여 물질을 구성하고 있는 원소의 성분, 미세원자구조, 전자구조에 관한 정보를 얻을 수 있는 새로운 spectrometer이다. 본 연구에서는 자체 개발한 XIEES의 XAFS 기능을 이용하여 여러 가지 방법으로 제조한 LiMn2-xO4와 LiMnO2, MnO2에서 Mn K-absorption edge에 대한 chemical state 변화를 측정하였다. Absorption edge에서 chemical shift를 측정하기 위해서는 방사광 가속기 수준의 에너지 분해능(~0.3eV)이 필요하다. 이번 연구에서는 SiO2(3140) monochromator를 사용하고 여기에 맞는 적절한 parameter를 적용하여 x-ray 에너지 분해능을 포항방사광가속기 수준으로 개선하였다. XIEES에서 얻은 스펙트럼과 포항방사광가속기에서 얻은 스펙트럼을 비교하였다. Chemical shift가 일어나는 경향은 두 실험 결과가 잘 일치하였다.

  • PDF

DETECTION OF X-RAY EMISSION FROM GALAXIES INSIDE AND TOWARDS THE NEARBY VOIDS

  • KIM CHULHEE;BOLLER TH.;GHOSH KAJAL K.
    • 천문학회지
    • /
    • 제38권1호
    • /
    • pp.1-6
    • /
    • 2005
  • We searched for X-ray emission from the 665 galaxies inside and towards the nearby voids by analyzing the ROSAT All-Sky Survey (RASS) data as well as the ROSAT pointed observations (PSPC). As a result we have detected six X-ray emitting galaxies. Two (UGC 10205 and NGC 7509) are in the high density region in the local void, three (UGC 749, MCG +11-10-073, and Mrk 464) are towards the nearby voids, and UGC 32 is located in the low density region. We carried out a timing analysis for both Mrk 464 and UGC 32, and a spectral analysis for Mrk 464. The light curve of Mrk 464 shows the possibility of periodic X-ray flux variation and UGC 32 shows weak, but rapid variation.

Basic Physical Principles and Clinical Applications of Computed Tomography

  • Jung, Haijo
    • 한국의학물리학회지:의학물리
    • /
    • 제32권1호
    • /
    • pp.1-17
    • /
    • 2021
  • The evolution of X-ray computed tomography (CT) has been based on the discovery of X-rays, the inception of the Radon transform, and the development of X-ray digital data acquisition systems and computer technology. Unlike conventional X-ray imaging (general radiography), CT reconstructs cross-sectional anatomical images of the internal structures according to X-ray attenuation coefficients (approximate tissue density) for almost every region in the body. This article reviews the essential physical principles and technical aspects of the CT scanner, including several notable evolutions in CT technology that resulted in the emergence of helical, multidetector, cone beam, portable, dual-energy, and phase-contrast CT, in integrated imaging modalities, such as positron-emission-tomography-CT and single-photon-emission-computed-tomography-CT, and in clinical applications, including image acquisition parameters, CT angiography, image adjustment, versatile image visualizations, volumetric/surface rendering on a computer workstation, radiation treatment planning, and target localization in radiotherapy. The understanding of CT characteristics will provide more effective and accurate patient care in the fields of diagnostics and radiotherapy, and can lead to the improvement of image quality and the optimization of exposure doses.