• Title/Summary/Keyword: X-ray Test

Search Result 1,510, Processing Time 0.033 seconds

Assessment of the Fertilizing Capacity of Domestic Animal Spermatozoa by Hamster Test II. Effects of incubation medium and X-ray irradiation on hamster test for boar spermatozoa (Hamster test를 이용한 가축정자의 수정능력 검정 II. 정액배지 및 X-선조사가 돼지정자의 Hamster test에 미치는 영향)

  • Kim Yong-Jun;Ji Dong-Boum
    • Journal of Veterinary Clinics
    • /
    • v.9 no.2
    • /
    • pp.373-390
    • /
    • 1992
  • To assay the fertilizing capacity of domestic animal spermatozoa by hamster test, semen were collected from 13 boars(Duroc. Landrace and Yorkshire) which had been proved to be fertile in the past. then, were preserved in BWW medium or in raw state at 18$^{\circ}C$ or at room temperature. The preserved semen were given each different treatment according to the experimental design and coincubated with zona-free hamster ova for 5 hours. The ova were stained by lacmoid and examined under phase contrast microscope to investigate the rates of ova bound with sperm(sperm binding). ova penetrated by sperm(penetration) and formation of a male pronucleus(pronucleus formation) and also numbers of both bound and penetrated sperm per ovum. Between BWW and TBM medium for boar sperm. no difference in the results of hamster test was obtained. The boar spermatozoa in BWW medium, BWW with caffeine, BWW with heparin, and BWW with both caffeine and heparin showed no difference in the results of hamster test. The boar spermatozoa in BWW medium containing both calcium and RSA showed considerably higher rates of sperm binding, penetration and pronucleus formation as well as higher numbers of both bound and penetrated sperm than those not containing calcium with or without BSA( p<0.01) and also the same results higher than that containing calcium without BSA( p< 0.05). The boar spermatozoa irradiated by X-ray(70 KVP, 20mA) for 3 seconds. then, maintained at 18$^{\circ}C$ for 18 hours showed considerably lower rate of sperm binding than all the other groups including the control and X-ray groups irradiated by smaller dose or maintained for shorter period(p<0.01), and also showed lower number of bound sperm than the other groups(p<0.01, p<0.05). All the control groups of both raw and diluted sperm in BWM medium showed higher rates of sperm binding, penetration and pronucleus formation as well as higher number of penetrated sperm than all the X-ray groups irradiated for 3 seconds(70KVP, 20mA) and maintained for either 3 or 18 hours (p<0.01, p<0.05). At the same time the control groups of diluted sperm showed considerably higher rates of sperm penetration and pronucleus formation than the control group of raw sperm( p<0.01). These results indicates that fertile boar sperm showed considerably lower rates In the results of hamster test, when incubated in the medium without calcium and irradiated by X-ray than when incubated in the medium with calcium and not irradiated by X-ray, respectively, to prove consequently that hamster test would be of great value in assaying the fertilizing capacity of boar spermatozoa.

  • PDF

Analysis on the Fatigue Fracture Surface of Gas Piping Material using the X-Ray Fractography (X-선 프랙토그라피에 의한 가스배관재의 피로파면해석)

  • Lim, Man-Bae
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.1
    • /
    • pp.18-24
    • /
    • 2002
  • This study verified the relationship between fracture mechanics parameters(${\Delta}K,\;K_{max}$) and X-ray parameters ($(\sigma}_r,;B$) for G365 steel at elevated temperature up to $300{\circ}C$. The fatigue crack propagation test were carried out and X-ray diffraction technique according to crack length direction was applied to fatigue fractured surface. The residual stress on the fracture surface was found to increase in low ${\Delta}K$ region, reach to a maximum value at a certain value of $K_{max}$ or ${\Delta}K$ and then decrease. Residual stress was independent on stress ratio by arrangement of ${\Delta}K$ and half value breadth was independent by the arrangement of $K_{max}$. The equation of ${\sigma}_r-{\Delta}K$ was established by the experimental data. Therefore, fracture mechanics parameters could be estimated by the measurement of X-ray parameters.

Effect of the amount of battery charge on tube voltage in different hand-held dental x-ray systems

  • Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.42 no.1
    • /
    • pp.1-4
    • /
    • 2012
  • Purpose : Hand-held dental x-ray system is a self contained x-ray machine designed to perform intraoral radiography with one or two hands. The issue about its usage as general dental radiography is still in dispute. The aim of the present study was to assess the relationship between the amount of battery charge and the tube voltage in different handheld dental x-ray systems. Materials and Methods : Seven hand-held dental x-ray units were used for the study. Tube voltage was measured with Unfors ThinX RAD (Unfors Instruments AB, Billdal, Sweden) for 3 consecutive exposures at the different amount of battery charge of each unit. The average and the deviation percentage of measured kV from indicated kV of each unit were calculated. Results : Tube voltage of only 1 unit was 70 kV (indicated by manufacturer) and those of the others were 60 kV. Tube voltage deviation percentage from the indicated kV at the fully charged battery was from 2.5% to -5.5% and from -0.8% to -10.0% at the lowest charged battery. Conclusion : Tube voltages of all units decreased as the residual amount of the battery charge decreased. It is suggested that the performance test for hand-held x-ray system should be performed for the minimum residual charged battery as well as the full charged one. Persistent battery charging is suggested to maintain the proper tube voltage of the hand-held portable x-ray system.

The Radiation Safety Management in the Animal Hospital Using Inspection Standard of Diagnosis Radiation System (진단용 방사선발생장치의 검사기준을 적용한 동물병원의 방사선 안전관리)

  • Kim, Sang-Woo;Rhim, Jea-Dong;Han, Dong-Kyoon;Seoung, Youl-Hun
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.73-80
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using inspection standard of X-ray generator for diagnosis. The surveys for inspection standard system, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The inspection standard included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. The surveys of equipment condition and safety supervision used one-on-one interview with 5 points measurement. As a result, 44.44% of reproducibility of dose exposure was proper, 81.25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test. The 100mA electric capacity of X-ray generator for diagnosis was popular with 44.44%, and its 55.56% was purchased used equipment. Monthly average of less than 50 times (61.11%) was top frequency in use, and no animal clinic had a thermo-luminescence dosimeter(TLD). The 16 animal clinics with radiation safety zone and 2 without radiation safety zone were appeared.

Development of Radiation Free Soft X-Ray Ionizer with Ion Control (완전차폐 및 이온조절형 연X선식 정전기제거장치의 개발)

  • Jeong, Phil Hoon;Lee, Dong Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.22-27
    • /
    • 2016
  • The Electrostatic Charge Prevention Technology is a core factor that highly influences the yield of Ultra High Resolution Flat Panel Display and high-integrated semiconductor manufacturing processes. The corona or x-ray ionizations are commonly used in order to eliminate static charges during manufacturing processes. To develop such a revolutionary x-ray ionizer that is free of x-ray radiation and has function to control the volume of ion formation simultaneously is a goal of this research and it absolutely overcomes the current risks of x-ray ionization. Under the International Commission on Radiological Protection, it must have a leakage radiation level that should be lower than a recommended level that is $1{\mu}Sv/hour$. In this research, the new generation of x-ray ionizer can easily control both the volume of ion formation and the leakage radiation level at the same time. In the research, the test constraints were set and the descriptions are as below; First, In order not to leak x-ray radiation while testing, the shielding box was fully installed around the test equipment area. Second, Implement the metallic Ring Electrode along a tube window and applied zero to ${\pm}8kV$ with respect to manage the positive and negative ions formation. Lastly, the ion duty ratio was able to be controlled in different test set-ups along with a free x-ray leakage through the metallic Ring Electrode. In the result of experiment, the maximum x-ray radiation leakage was $0.2{\mu}Sv/h$. These outcome is lower than the ICRP 103 recommended value, which is $1{\mu}Sv/h$. When applying voltage to the metallic ring electrode, the positive decay time was 2.18s at the distance of 300 mm and its slope was 0.272. In addition, the negative decay time was 2.1s at the distance of 300 mm and its slope was 0.262. At the distance of 200 mm, the positive decay time was 2.29s and its slope was 0.286. The negative decay time was 2.35s and its slope was 0.293. At the distance of 100 mm, the positive decay time was 2.71s and its slope was 0.338. The negative decay time was 3.07s and its slope was 0.383. According to these research, the observation was shown that these new concept of ionizer is able to minimize the leakage radiation level and to control the positive and negative ion duty ratio while ionization.

Factors Associated with Radiologic Tests in Patients with Radial Head Subluxation (요골두아탈구 환자에서 방사선 검사 시행과 연관된 인자 분석)

  • Chang, Ikwan;Kim, Do Kyun;Park, So Young;Suh, Dongbum;Jung, Jae Yun;Kwak, Young Ho
    • Journal of Trauma and Injury
    • /
    • v.27 no.2
    • /
    • pp.13-19
    • /
    • 2014
  • Purpose: In general, X-ray examinations are not recommended for radial head subluxation (pulled elbow) patients. The purpose of this study was to determine the frequency of X-ray examinations and to investigate the factors associated with the decision to perform an X-ray examination on a patient with a pulled elbow. Methods: Patients who visited the pediatric emergency department (ED) of one tertiary hospital from January 1, 2011, to December 31, 2012, with a diagnosis of radial head subluxation at discharge were enrolled in this study. Through retrospective chart reviews, factors that could have influenced the decision to perform an X-ray examination and their statistical relevance were analyzed. Results: A total 308 patients were enrolled, and 101 patients (32.8%) underwent X-ray examinations. Among the 252 patients with a typical pulled elbow, 65 underwent X-ray examination. This result showed statistical significance compared to atypical pull-elbow group (25.8% vs. 64.3%, p<0.001). Factors associated with the decision to perform an X-ray examination were analyzed using the Chi-square test and the Fisher's exact test. The mechanism of injury and consultation with an orthopedic surgeon (p=0.001) showed statistical significance. In the multivariable logistic regression, the odds ratio (OR) for the injury mechanism was 4.7 (95% CI: 1.8~8.8, p<0.001) and that for consultation with an orthopedic surgeon was 8.0 (95% CI: 1.6~40.7, p=0.004). Conclusion: One third of patients with a pulled elbow underwent X-ray examination, and patients with an atypical mechanism of injury underwent more frequent X-ray examinations than did patients with a typical mechanism of injury. The factors that could have influenced the decision to perform an X-ray examination were mechanism of injury and consultation with an orthopedic surgeon.

Evaluation of X-ray System for Nondestructive Testing on Radioactive Waste Drums (방사성폐기물 드럼 비파괴 검사를 위한 X-ray 장비 평가)

  • Park, Jong-Kil;Maeng, Seong-Jun;Lee, Yeon-Ee;Hwang, Tae-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.3
    • /
    • pp.189-203
    • /
    • 2008
  • The physical and chemical properties of radioactive waste drums, which have been temporarily stored on site, should be characterized before their shipment to a disposal facility in order to prove that the properties meet the acceptance guideline. The investigation of NDT(Nondestructive Test) method was figured out that the contents in drum, the quantitative analysis of free standing water and void fraction can be examined with X-ray NDT techniques. This paper describes the characteristics of X-ray NDT such as its principles, the considerations for selection of X-ray system, etc. And then, the waste drum characteristics such as drum type and dimension, contents in drum, etc. were examined, which are necessary to estimate the optimal X-ray energy for NDT of a drum. The estimation results were that: $(R)\acute{A}$ the proper X-ray energy is under 3 MeV to test the drums of 320 ${\beta}\S$ and less; $(R)\ddot{E}$ both X-ray systems of 450 keV and/or 3 MeV might be needed considering the economical efficiency and the realization. The number of drums that can be tested with 450 keV and 3 MeV X-ray system was figured out as 42,327 and 18,105 drums (based on storage of 2006. 12), respectively. Four testing scenarios were derived considering equipment procurement method, outsourcing or not, etc. The economical and feasibility assessment for the scenarios was resulted in that an optimal scenario is dependent on the acceptance guide line, the waste generator's policy on the waste treatment and the delivery to a disposal facility, etc. For example, it might be desirable that a waste generator purchases two 450 keV mobile system to examine the drums containing low density waste, and that outsourcing examination for the high density drums, if all NDT items such as quantitative analysis for 'free standing water' and 'void fraction', and confirmation of contents in drum have to be characterized. However, one 450 keV mobile system seems to be required to test only the contents in 13,000 drums per year.

  • PDF

A Study on the On-site Flame Resistant Inspection Method by X-ray Fluorescence Spectrometer (X-선 형광분석기를 이용한 현장방염검사방법에 관한 연구)

  • Kim, Hwang-Jin;Lee, Sung-Eun
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.124-129
    • /
    • 2016
  • According to the current law, on-site flame resistant-treated interior decorations should pass the flame resistant performance test through a 45 degree combustion test from the district fire department. Although a 45 degree combustion test is the most accurate method for determining the flame resistant performance, it can be unreliable when tested on unauthorized samples. To avoid unauthorized sampling, this study suggests on-site flame resistant inspection by X-ray fluorescence spectrometer. Ten types of flame resistant paint were spread on plywoods and MDFs and the components were analyzed by X-ray fluorescence spectrometer. As a result, due to a difference amounts of substances in each paint, each flame resistant paints showed its own characteristic spectrum and the contents of each substance could be determined. On-site flame resistant inspections can be used efficiently when institutional procedures are created.

Mechanical properties and radiation shielding performance in concrete with electric arc furnace oxidizing slag aggregate

  • Lim, Hee Seob;Lee, Han Seung;Kwon, Seung Jun
    • Journal of Ceramic Processing Research
    • /
    • v.20 no.4
    • /
    • pp.363-371
    • /
    • 2019
  • In this study, physical properties of normal concrete, magnetite concrete, EAF concrete, and EAF concrete with added iron powder were evaluated and a feasibility of radiation shielding is also evaluated through irradiation tests against X-rays and gamma-rays. While the unit weight of EAF concrete (3.21 t/㎥) appeared lower than that of magnetite concrete (3.50 t/㎥), the results in compressive strength of EAF concrete were greater than those in magnetite and normal concrete. While the radiation transmission rate of normal concrete reaches 26.0% in the X-ray irradiation test, only 6.0% and 9.0% of transmission rate were observed in magnetite concrete and linear relationship with unit volume weight and radiation shielding. In the gamma-ray irradiation test, the performance of EAF and magnetite concretes appeared to be similar. Through the results on the excellent physical properties and radiation shielding performance a potential applicability of EAF concrete to radiation shielding was verified.